| 1 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 2 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 3 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 4 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. Up to 35 sqmm |
| 5 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm |
| 6 | Supply, installation, testing and commissioning of 25 mm Outer dia CPVC PIPE with end caps including making air sampling opening of appropriate dia on appropriate interval and all accessories as required,(rate for area protected in sqm). |
| 7 | S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ). |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 9 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 10 | SITC of 50mmx50mmx6mm angle iron mounting stand for ACP sign board and painting with primer and finshied paint. |
| 11 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete |
| 12 | P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd. |
| 13 | Supply installation Testing and Commisioning of 9W/12W LED bush/spike light (with mounting pipe) with dia cast aluminium housing with toughened glass suitable for ground mounting enclosed with glass cover in frame, mounting bracket provided for ground aiming the object, high ingress protection against dust & moisture, corrosion resistant coated and IP- 65/66 protection as required. (a) Lumen efficacy >90 LM/watt. (b) PF>.95 (C) Rated Voltage 220-240 VAC 50Hz. |
| 14 | Supply of XLPE insulated PVC sheathed Al. Conductor unarmoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*4 sqmm |
| 15 | Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size 25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd. |
| 16 | SITC of 3mm (Min.) ACP Sheet based, acrylic Raised letters LED board with 1\\"x1\\" M.S. square pipe box type frame, pipe frame all open sides covered by G.I. sheet properly |
| 17 | Fabrication, supplying, installation, testing and commissioning of openable Signage made of electrocut computerised automated individual letters in hindi & English, total Covering Area and design as per direction of Engineer in charge, Letters to be made from powder coated sheet with 100-150 mm bottom profiles bended along 4-5mm thick sheet of unbreakable Acrylic Sheet to be used in front which will be pinned to the profile. Approved Color, Vinyl (UV) to be used for Colorful look on the front of Acrylic sheet, Letters back should be duly powder coated/painted with Primer & two coats of approved Color Enamel or Duco paint. The signage shall have a system for easy graphic changes and easy access for maintenance. The illumination source shall be of LEDs or approved equivalent modules with individual current regulator/power supply driver module for every signage complete with all internal wiring etc along with connectors for connections to achieve required and uniform illuminations, specifications and design as per the directions of Engineer in charge. LED specification :Lumen output : 2500 lumens/sq mtr (minimum) radiance angle : 120 degree and above Illumination should be uniform and suitable arrangement should be made for installation of the whole structure using Gi pipes, angles etc but excluding foundation work. Please Enable Macros to View BoQ information |