| 1 | Steel tubular swaged pole type 410 SP-31 (9 metre long) with 300 mmx300mmx6mm mild steel base plate continuously welded to pole, final taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5m from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5m from ground level/coping and also write the pole No on the surface of pole, complete all as specified and directed. |
| 2 | Taking down old UNSV street lights and supply fixing LED Street light fitting 35 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 66 protection complete all as specified and directed |
| 3 | Taking down old UNSV street lights and supply fixing LED Street light fitting 60 watt 230 V AC outdoor type with high pressure die cast 60 aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 66 protection complete all as specified and directed |
| 4 | Taking down old UNSV street lights and supply fixing LED Street light fitting 90 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 66 protection complete all as specified and directed |
| 5 | Taking down unserviceable LED Street light fitting of capacity 35/60/70 watt from LT Pole and replacement of unsv electronic driver/controller of suitable capacity and making LED light seviceable and refixing on LT Pole complete all as directed. |
| 6 | Taking down old/unsv flood lights from high mast light of any type and Supply and fixing LED flood light of capacity 120 watt IP 66 Luminaries with aluminium die cast housing toughened glass and unique lens system for enhancement illumination with all accessories complete all as specified and directed |
| 7 | Taking down old unsv brackets & Supply and fixing street light bracket for street light fittings made to shape as directed out of G.I. pipe light grade 40mm bore 1.5 mr long including fixing of light fittings and bracket with MS clamps, nuts and bolts of appropriate size complete all as specified and directed. |
| 8 | PVC conduit heavy duty of size 20 mm dia from looping box to Street light connector, holding in MS clamp of size 25X2 mm thick at every one mtr used in each pole 04 Nos of clamps with necessary nut, bolts and washers etc and including PVC sheathed three core multi stranded copper conductor cable of size 1.5 sqmm from looping box to light fitting connector and including taking down of old unserviceable items, complete all as specified and directed. |
| 9 | Flat aluminium cable size 2.5 sqmm x 2 core required for street light connection incl PVC Conduit with & including taking down burnt old unsv cable of any size, complete all as specified and directed. |
| 10 | Taking down old /unsv earthing and Material, Labour for Earthing complete with galvanized steel earth plate electrode 600mm x600mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground leel, connecting to the Galvanised earthing lead strip 32x6mm size, by means of bolts, nuts, heck nuts and washers of galvanized iron and earth lead protected by provision of GI medium grade pipe 40mm bore incl provision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC 1:2:4 reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape Gl medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt & charcoal filling, test point made out of 40mm x 8mm Fl with fixing arrangement, funnel, wire mesh and earth work in soft/loose soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs, all as per electrical plate No 5 of SSR-1991 Part I and connected to earth test point all as specified or indicated incl testing on completion. |
| 11 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 12 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor. 1100 Volt grade, cross sectional area 25 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 13 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor 1100 Volt grade, cross sectional area 35 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. . |
| 14 | Taking down burnt cable and Supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor 1100 Volt grade, cross sectional area 50 sqmm 3.5 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 15 | Replacement of 40mm bore of tubes 'light grade' galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cable complete all as specified and directed. |
| 16 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundation of laying cable including getting out in soft/loose soil complete all as specified and directed. |
| 17 | Ditto all as per item No. 16 above but for additional 1.5 mtr or part there of in depth beyond the first 1.5 mtr |
| 18 | Plain Cement Concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in foundation of electric poles/struts/cables, filling and mass concrete etc including necessary form work and fair finish to exposed surfaces without using extra cement, complete all as specified and directed. |
| 19 | Plain Cement Concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of electric poles/struts/cables, filling and mass concrete etc including necessary form work and fair finish to exposed surfaces without using extra cement, complete all as specified and directed. |
| 20 | Plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in pole coping, roof kerbs including necessary form work, complete all as specified and directed. |
| 21 | Returning filling in including spreading watering and well ramming in layers not exc 25 cm complete all as specifed . |
| 22 | Removing surplus soil to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed . |
| 23 | Supply, Installation, commisissioning and testing CPORI approved of 4 KW Street light control panel board/street light timer DB, 440 v ac 3 Phase 4 wire out door installation \\"KIOSK TYPE\\" with sloping canopy fabricated out of steel sections i.e. CRCA sheet 3,.15 mm thickness, angle/channel and flat iron sections of suitable size with opening on front, fitted with handle and bolts for pad lock. The panel door shutters fixed with stainless steel hinges, heavy duty and with door stoppers. The door opening shall not be less than 150 degree. The construction of panel board shall be dust, vermin proof, IP 65 standard with phosphatised powder coating painting externally and internally to protect against corrosion. The panel shall be mounted on suitable size of channel section having board with necessary PCC work of 1:2:4 type B-1 (using 20mm graded stone aggregate) including provision of opening for incoming/outgoing cables, cable glands, mounting clamp with nut bolts etc. incl taking down old panel complete all as directed with duly incorporated with following accessories:- (i) Main Incomer MCB 40 Amp FP, 10 KA-01 No (ii) Control MCB SP 5 Amp -01 No, (iii) Contractor 3P, 40 Amp with Digital time switch for Auto on/off-01 set (iv) LED Indicator RYB-1 Set (v) Selector switch for bypass arrangement-01 No |
| 24 | Disconnecting all electrical connection of high mast lights 15m high, down all light accessories for repair, incl replacement of non functional mech parts of winch, motor and Re-fixing of same complete all as per site and all as specified and directed. Note- Flood lights replacement shall be paid and measured separately |
| 25 | Supply and fixing in replacement moulding compound street light junction box of size 200mm x 160mm x 98mm complete with shock and rust proof, termite resistant, tamper proof, front openable type and including suitable provision for three phase, four wire cable (size upto 25 Sqmm 4 Core) incoming & outgoing loop -in loop connection and including one no. MCB SP 6 Amp including non metallic clamps and Gl nut bolts and washers of suitable size and fixed on pole / wall complete ail as specified and directed. |
| 26 | Supply and fixing in replacement of LED Bollard light with opal acrylic diffuser and IP 66 Protection having Wattage 15 Watt and CCT 3000 K complete all a specified an directed. Make- \\"BGBOM 1000 15 W LED WW\\" of Bajaj or its equivalent Cat Part of Havells, Surya, HPL as approved by GE. |
| 27 | Supply and fixing in replacement for post top lantern LED type 24 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 28 | Supply, installation and testing of Solar street light fitting of capacity of 24Watt including suitable size galvanised steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed.Cat Part No SOLAR AI024W of Havells or equivalents in Bajaj, Wipro, Surya as approved by GE. Please Enable Macros to View BoQ information |
| 29 | Supply, installation and testing of Solar street light fitting of capacity of 24Watt including suitable size galvanised steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed.Cat Part No SOLAR AI024W of Havells or equivalents in Bajaj, Wipro, Surya as approved by GE. Please Enable Macros to View BoQ information |