| 1 | Taking down carefully copper/aluminium point wiring complete (light, fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets , removing materials to store and offering credit & making good of disturb surfaces of wall/floors etc complete all as specified and directed. |
| 2 | M& L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete as per site requirement and complete all as specified and directed for the following:- (a) One light point or one fan point controlled by one switch with cables 1.5 sq. mm size Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc. |
| 3 | All as per ser item No. 2 above, but for One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire complete all as specified and directed. |
| 4 | All as per ser item No. 2 here in before, but for One 5 Amp 5 pin socket outlet point on independent board complete all as specified and directed. |
| 5 | All as per ser item No. 2 here in before, but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 5 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes complete all as specified and directed. |
| 6 | All as per ser item No. 2 here in before, but one light point controlled by 2 way switches complete all as specified and directed. |
| 7 | All as per ser item No. 2 here in before, but one bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed. |
| 8 | M & L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FR type drawn through and including PVC casing caping/ PVC Conduit (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, columns/ beams alongwith 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metallic bodies of luminaire/ fan at other end including PVC folding boards with sunmica top for mounting switches, sockets, fan Regulators, accessories etc as per site requirement and complete all as specified and directed for the following:- (a) One light point or one fan point controlled by one switch with cables 1.5 sq. mm size. |
| 9 | All as per ser item No. 8 above, but for One 5 Amp 5 pin socket outlet point on same board with other switches including earth wire complete all as specified and directed. |
| 10 | All as per ser item No. 8 here in before, but for One 5 Amp 5 pin socket outlet point on independent board complete all as specified and directed. |
| 11 | All as per ser item No. 8 here in before, but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 5 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes complete all as specified and directed. |
| 12 | All as per ser item No. 8 here in before, but one bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed. |
| 13 | All as per ser item No. 8 here in before, but one light point controlled by 2 way switches complete all as specified and directed. |
| 14 | S&F bell push, flush type, 5 Amp single pole, 230 volts white finish complete all as specified and directed. |
| 15 | S&F switch piano flush button 5 Amp single pole 2 way 230 volts white finish complete all as specified and directed. |
| 16 | S&F in replacement switch piano flush button 5 Amp single pole one way 230 volts white finish complete all as specified and directed. |
| 17 | S&F in replacement of socket outlet flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish complete all as specified and directed. |
| 18 | S&F in replacement switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish complete all as specified and directed. |
| 19 | S&F in replacement of switch socket combination multipurpose flush type 2 in 1 type (3 and 5 pin) 5/15 Amps, 230V, AC complete all as specified and directed. |
| 20 | S&F in replacement ceiling rose surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish complete all as specified and directed. |
| 21 | S&F in replacement surface and wall mounted LED batten 20 watt - 4Ft White with Aluminium housing & integrated electronic driver, high performance batten and efficacy should not less than100 lumen/watt and all as specified and directed complete all as specified and directed. |
| 22 | S&F in replacement surface and wall mounted LED batten 10 watt - 2Ft White with Aluminium housing & integrated electronic driver, high performance batten and efficacy should not less than 100 lumen/watt and complete all as specified and directed. |
| 23 | S&F in replacement LED light fitting 1x9W/ 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size as per site requirement and complete all as specified and directed. |
| 24 | S&F in replacement energy efficient Street/ Roadway/Building Security Luminaire LED fitting upto 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, including brackets and all accessories needed to fixed to the wall or pole all as per site requirement and complete all as specified and directed. |
| 25 | S&F in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed. |
| 26 | S&F in replacement stepped type electronic fan regulator Socket type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed. |
| 27 | S&F in replacement exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete as per site requirement and complete all as specified and directed. |
| 28 | Taking down carefully copper/aluminium sub main wiring complete alongwith all connected accessories etc complete all as specified and directed. |
| 29 | M&L of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one length of sub main with colour code Red Black and Green. (ii) PVC conduit / casing caping and its accessories is deem to be included in this item rates. (iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc. |
| 30 | M&L of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty PVC casing caping upto 32mm or PVC conduit upto 25mm on wall surface/ recessed as required at site including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one lengt of sub main. (ii) PVC conduit / casing caping and its accessories is deem to be included in this item rates. |
| 31 | M&L of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 4 Sqmm drawn through in and including rigid PVC heavy duty PVC casing caping upto 32mm or PVC conduit upto 25mm on wall surface/ recessed as required at site including 4 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables and one run of continuous earthing cable drawn in conduit/ casing and caping will be measured as one length of sub main. (ii) PVC conduit / casing caping and its accessories is deem to be included in this item rates. |
| 32 | Taking down carefully DB/ Sheet Metal Enclosure with existing MCBs complete & making good of disturb surfaces of wall/floors etc complete all as specified and directed. |
| 33 | S&F distribution board sheet metal enclosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 4 ways complete all as specified and directed. |
| 34 | S&F distribution board sheet metal enclosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 8 ways complete all as specified and directed. |
| 35 | S&F in replacement MCB SP 5 to 32 Amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and directed. |
| 36 | S&F in replacement MCB SPN 32 Amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and directed. |
| 37 | S&F in replacement MCB SPN 40 to 63 Amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and directed. |
| 38 | S&F in replacement of MCB TP 25 to 63 Amps, 415 Volts, 50 Hz with 10 KA 'C' curve complete with connection testing and commissioning complete all as specified and directed. |
| 39 | S&F in replacement of MCB TPN 16 to 32 Amps, 415 Volts, 50 Hz with 10 KA 'C' curve complete with connection testing and commissioning complete all as specified and directed. |
| 40 | S&F in replacement of MCB TPN 40 to 100 Amps, 415 Volts, 50 Hz with 10 KA 'C' curve complete with connection testing and commissioning complete all as specified and directed. |
| 41 | M&L in replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thickness buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board complete all as specified and directed and testing on completion. |
| 42 | Taking down for servicing of split type AC 1.5TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner Or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections if required and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and directed. |
| 43 | Taking down for servicing of split type AC 2.0/2.5TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing electrical connections and keeping the AC unit in satisfactory working condition after necessary servicing and refixing the same in existing position complete all specified and directed. |
| 44 | S&F in repair starting relay for 1.5 TR compressor complete all specified and directed. |
| 45 | S&F in repair starting relay for 2 TR compressor complete all specified and directed. |
| 46 | S&F in repair Thermostat switch for 1.5 TR split/window type AC complete all specified and directed. |
| 47 | S&F in repair of Starting capacitor 80-100 Mfd capacity in metal container complete all specified and directed. |
| 48 | S&F in repair of running capacitor 36 Mfd capacity in metal container pin type complete all specified and directed. |
| 49 | S&F in repair of running capacitor 50+4 Mfd capacity in metal container pin type complete all specified and directed. |
| 50 | S&F in repair of running capacitor 50+6 Mfd capacity in metal container pin type complete all specified and directed. |
| 51 | S&F in repair of running capacitor 55 Mfd capacity in metal container pin type complete all specified and directed. |
| 52 | S&F in repair of running capacitor 60 Mfd capacity in metal container pin type complete all specified and directed. |
| 53 | S&F Running capacitor 10 mfd metal body pin type complete all as specified and directed. |
| 54 | S&F Running capacitor 6 mfd metal body pin type complete all as specified and directed. |
| 55 | S&F Running capacitor 4 mfd metal body pin type complete all as specified and directed. |
| 56 | S&F Running capacitor 2.5 mfd metal body pin type complete all as specified and directed. |
| 57 | S&F Running capacitor 1.5 mfd metal body pin type complete all as specified and directed. |
| 58 | S&F Running capacitor 2.0mfd metal body pin type complete all as specified and directed. |
| 59 | S&F in repair suction copper pipe line heavy duty 1/2'' dia and flair nuts from indoor to outdoor unit of split AC 1.5 /2 TR capacity complete all specified and directed. |
| 60 | S&F in repair discharge copper pipe line heavy duty 1/4\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity complete all specified and directed. |
| 61 | S&F in repair discharge copper pipe line heavy duty 5/8\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity complete all specified and directed. |
| 62 | S&F in repair discharge copper pipe line heavy duty 3/8\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity complete all specified and directed. |
| 63 | S&F in repair discharge copper pipe line heavy duty 3/4\\" dia and flair nuts from indoor to outdoor unit of split AC 1.5 TR /2 TR capacity complete all specified and directed. |
| 64 | S&F in repair PVC pipe nylon imbraided 20 mm dia for condenser water drain fitted with clamps/ concealed in wall complete all specified and directed. |
| 65 | S&F Foam insulation for copper tubing of size 1/2'' dia complete all specified and directed. |
| 66 | S&F Foam insulation for copper tubing of size 5/8'' dia complete all specified and directed. |
| 67 | S&F Foam insulation for copper tubing of size 1/4'' dia complete all specified and directed. |
| 68 | S&F Foam insulation for copper tubing of size 3/8'' dia complete all specified and directed. |
| 69 | S&F Foam insulation for copper tubing of size 3/4'' dia complete all specified and directed. |
| 70 | Dismantling of defective condensing unit of split type AC of 1.5 TR capacity and S&F new condensing unit complete with condensing copper coil complete all specified and directed. |
| 71 | Dismantling of defective condensing unit of split type AC of 2 TR capacity and S&F new condensing unit complete with condensing copper coil, complete all specified and directed. |
| 72 | Dismantling of burnt blower motor of 1.5 TR split AC (indoor unit) and S&F blower motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star as per sample complete all specified and directed. |
| 73 | Dismantling of burnt blower motor of 2 TR split AC (indoor unit) and S&F blower motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Lloyd as per sample complete all specified and directed. |
| 74 | Dismantling of burnt condensor motor of 1.5 TR split AC (Outdoor unit) and rewinding & refixing condenser motor at same position including replacement of bearing bushing complete. Make of AC Carrier/Voltas /Blue star as per sample complete all specified and directed. |
| 75 | Dismantling of burnt condensor motor of 2 TR split AC (Outdoor unit) and rewinding & refixing condenser motor at same position including replacement of bearing bushing complete. Make of AC Carrier/Voltas /Blue star/LG/Samsung as per sample complete all specified and directed. |
| 76 | Dismantling of burnt swing motor of 1.5 TR split AC (indoor unit) and S&F swing motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung as per sample complete all specified and directed. |
| 77 | Dismantling of burnt swing motor of 2/2.5 TR split AC (indoor unit) and S&Fing swing motor of same manufacturer of AC. Make of AC Carrier/Voltas /Blue star/LG/Samsung as per sample complete all specified and directed. |
| 78 | Supply and charging (Top up) the AC unit of 1.5 TR /2/2.5 TR split type AC unit with Refrigerant Gas compatible to R-22 type in required quantity complete all specified and directed. |
| 79 | Supply and charging (Top up) the AC unit of 1.5 TR /2/2.5 TR split type AC unit with Refrigerant Gas compatible to R-134 type in required quantity complete all specified and directed. |
| 80 | Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-410 type in required quantity complete all specified and directed. |
| 81 | Supply and charging (Top up) the AC unit of 1.5 TR /2 TR split type AC unit with Refrigerant Gas compatible to R-32 type in required quantity complete all specified and directed. |
| 82 | Supply and charging the AC unit of 1.5/2/2.5/3.5/4.5 TR split type AC unit with Nitrogen Gas for detecting of leakages required as per site quantity complete all as specified and directed. |
| 83 | S&F in repair of suction valve size 1/2\\" complete all specified and directed. |
| 84 | S&F in repair of discharge valve size 1/4\\" complete all as specified and directed. |
| 85 | S&F in repair of suction valve size 5/8\\" complete all as specified and directed. |
| 86 | S&F in repair of discharge valve size 3/8\\" complete all as specified and directed. |
| 87 | Dismantling of un-serviceable cooling coil unit any type any size of indoor unit of split type Air Conditioner of capacity 1.5 TR by cutting the suction line and discharge line, and providing new cooling copper coil unit of indoor unit (of same capacity), including testing on completion complete all specified and directed. |
| 88 | Dismantling of un-serviceable cooling coil any type any size of indoor unit of split type Air Conditioner of capacity 2.0 TR by cutting the suction line and discharge line, and providing new cooling copper coil of indoor unit (of same capacity),including testing on completion complete all specified and directed. |
| 89 | M&L for carrying out pressure leak test of split ACs 1.5 TR capacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule |
| 90 | M&L for carrying out pressure leak test of split ACs 2.0 TR capacities by Nitrogen gas pressure for detecting leak in cooling unit refrigerant pipe and repairing the leak by welding or brazing of cooling unit and refrigerant pipe, putting under pressure for leak checking after repairs of leak pipe including gas charging transporting & carrying out Tools and Plant required at site complete all specified and directed. Note : Cost of Nitrogen gas will be paid under respective schedule |
| 91 | Dismantling of defective worn out wiring of indoor unit and outdoor unit of split AC of capacity 1.5 TR including unserviceable cordless electronic remote control, S&F PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all specified and directed. |
| 92 | S&F AC sensor set indoor and outdoor unit as per site requirement complete all specified and directed. |
| 93 | S&F AC sensor indoor ambient temp sensor and coil sensor as per site requirement complete all specified and directed. |
| 94 | Dismantling of defective worn out wiring of indoor unit of All weather split AC of capacity 2 TR including unserviceable cordless electronic remote control, S&F PCB (Printed circuit Board) & Visual Eye demo plate to suit /match the existing system complete all specified and directed. |
| 95 | M&L PVC insulated and PVC round sheathed copper conductor (flexible) industrial cable, (FRLS) 1100 Volts, conforming to IS 694 of size 2.5 sqmm 3 Core connecting electrical equipments with terminal lugs / clips as per site requirement, complete all specified and directed. |
| 96 | S&F Compressor sealed unit for Split type Air Conditioner of capacity 1.5 ton reciprocating compressor by removing of old burnt compressor and fixing as per manufacturer instruction including providing connections of gas line, fixing of copper tubes of suitable sizes, hand shut off valves, relays, starting and running capacitors etc complete all specified and directed. Note :- Charging of gas refrigerant will be paid and measured separately. |
| 97 | All as per item No 96 above, but 2/3 TR capacity reciprocating compressor complete all specified and directed. |
| 98 | All as per item No 96 here in before, but 1.5 TR capacity rotary type complete all specified and directed. |
| 99 | All as per item No 96 here in before, but 2 TR capacity rotary compressor complete all specified and directed. |
| 100 | S&F Condenser fan blade suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all specified and directed. |
| 101 | S&F Condenser fan blade suitable for 2.0 TR capacity Split type Air Conditioner including taking out old one complete all specified and directed. |
| 102 | S&F Roller runner, suitable for 1.5 TR capacity Split type Air Conditioner including taking out old one complete all specified and directed. |
| 103 | S&F Roller runner, suitable for 2.0/3.0 TR capacity all weather Split type Air Conditioner including taking out old one complete all specified and directed. |
| 104 | Taking down indoor unit of 1.5 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all specified and directed. (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item of this BOQ) |
| 105 | Taking down indoor unit of 2.0/2.5 TR capacity by preserving the existing gas in outdoor unit, checking and overhauling the complete indoor unit part by part and refixing at same position including testing complete all specified and directed. (Note:-The repair of indoor motor, filters and roller runner to be measured and paid separately under relevant item of this BOQ) |
| 106 | S&F in replacement of AC Outdoor metallic stand for fixing out door unit complete all as specified and directed. |
| 107 | Taking down unserviceable blower motor base (2mm thick Mild Steel Sheet) of 1.5 TR/2TR capacity split AC and S&Fing new blower motor base by welding / fixing by nut and bolt refixing the blower motor after completing the base and aligning the motor complete all specified and directed. |
| 108 | S&F remote control hand set for 2.0TR capacity split AC complete all specified and directed. |
| 109 | S&F remote control hand set for 1.5TR capacity split AC complete all specified and directed. |
| 110 | Dismantling of defective refrigerator of any make and capacity including transportation to workshop and back for thorough checking of all accessories and components, repairs and reassembling the same after repair/replacement of defective accessories/components and testing complete all specified and directed. |
| 111 | S&F Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 165/180 ltrs complete all specified and directed. |
| 112 | S&F Cooling chamber including cooling coil of existing size shape suitable for refrigerator of size and of capacity 280/310 ltrs complete all specified and directed. |
| 113 | S&F Thermostat defrost type switch suitable for refrigerator of capacity 165 to 310 ltrs complete all specified and directed. |
| 114 | S&F PTC Relay with overload suitable for refrigerator of capacity 170/210 ltrs complete all specified and directed. |
| 115 | S&F PTC relay with overload suitable for refrigerator of capacity 250/286/310 Ltr complete all specified and directed. |
| 116 | S&F Capillary tube of size 0.36mm dia for any type/size refrigerator complete all specified and directed. |
| 117 | S&F Copper pencil strainers of size 4\\" long double mouth complete all specified and directed. |
| 118 | S&F PCB with Wiring set complete consisting of PVC insulated flexible wire with stranded copper conductor of size 1.5 sqmm and fixing clips for refrigerator all types complete all specified and directed. |
| 119 | S&F Bimetal 2 wire/3wire /4 wire complete all specified and directed. |
| 120 | S&F Forst free fan motor SP 230 volts complete all specified and directed. |
| 121 | S&F PCB timer of refrigerator 170-310ltrs required as per site complete all specified and directed. |
| 122 | S&F Condenser coil for 165 to 210 Ltrs complete all specified and directed. |
| 123 | S&F Condenser coil for 250 to 310 Ltrs complete all specified and directed. |
| 124 | S&F of heating coil including fixing accessories suitable for 250/286/310 ltrs complete all specified and directed. |
| 125 | Taking out burnt compressor after disconnecting suction and discharge line and S&F new compressor as per existing including testing complete all as specified and directed for Refrigerator of Capaicty 210 to 310 Ltrs (Re- Charging of gas will be measured and paid separately) |
| 126 | Dismantling of defective deep freezer including transportation to workshop and back of any capacity, size and type for thorough checking of all accessories and components re-assembling the same after repair/ replacement of defective accessories/components including testing complete all specified and directed. |
| 127 | S&F new deep freedge compressor for storage capacity of 500/320/205ltrs deep freezer including testing complete all specified and directed. (Recharging of gas will be measured and paid separately). |
| 128 | S&F Relay for deep freezer of any size/capacity complete all specified and directed. |
| 129 | S&F Overload for compressor of deep freezer of any size/capacity complete all specified and directed. |
| 130 | S&F Thermostat for deep freezer complete all specified and directed. |
| 131 | S&F 4\\" condenser fan motor 240 volt complete all specified and directed. |
| 132 | S & F microcontroller based programmable AC timers for switching air conditioner at 4 hours or 8 hours interval complete all specified and directed. |
| 133 | S& F 4 KVA auto corrector single phase, sine wave, 240 volts, AC supply, 50 Hz and Conforming to IS;8448 all complete all specified and directed. |
| 134 | S& F 5 KVA auto corrector single phase, sine wave, 240 volts, AC supply, 50 Hz and Conforming to IS;8448 all complete all specified and directed. |
| 135 | NOTES :-1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information |