| 1 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) not exceeding 1.5 Square Metre each, removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed. |
| 2 | All as per Item No.1 above but exc. 1.5 sqm and not exc. 4 sqm each, complete all as specified and as directed |
| 3 | Taking down shutter from frame exc. 1 sqm but n. Exc. 2 sqm each including iron mongrey & removing from site complete all as specified and directed by Engr-in-charge. |
| 4 | Taking down shutter from frame exc. 1 sqm but n. Exc. 2 sqm each and refixing in same opening after resecuring or easing, and adjusting complete all as specified and directed by Engr-in-charge |
| 5 | S&F 2nd class hard wood plain solid, straight, chowkats and frames wrought framed rebated on the solid , rounded or chamfered or ornamental type put together with glue pinned at joints, complete all as specified and directed. |
| 6 | M&L second class hardwood 30 mm thickness plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and directed by Engr-in-Charge |
| 7 | M&L second class Hardwood 30 mm thickness, glazed and skeleton door shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters complete all as specified and directed |
| 8 | Material and Labour 30mm thick factory made pre laminated flush door shutters, with 0.90 mm Decorative laminate type 1 of surface finishes on both faces in hi-gloss (colour and pattern as approved) fixed with approved adhesive as per manufacturer's instructions and confirming to IS -2046 and solid core construction, with block board core and plywood face panels, suitable for exterior & interior grade door, commercial type on both sides complete all as specified and directed |
| 9 | S& F of Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as per direction of Engineer-In-Charge. Note: stainless steel butt hinges elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer and necessary S S screws shall be paid separately. |
| 10 | S& Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note - M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately. |
| 11 | S& Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm (double rebate) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note:- M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately. |
| 12 | S&F Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete all as specified by the manufacturer and as per directions of Engineer-in-charge. |
| 13 | S&F to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete all as specified by the manufacturer and as per directions of Engineer- in-charge. |
| 14 | S&F in repair 18/19mm thick medium density fibre boards, exterior grade, commercial type, and both faces covered with approved pattern decorative coloured laminate type 1 of 0.9mm thick, and all around side faces is covered with decorative lipping complete prepared as cupboard shutter and fixed with wooden frame-work complete alll as specified and directed |
| 15 | S&F in repair to Cabinet Hinges Soft Close SS 8 Crank complete all as specified and directed |
| 16 | S&F magnetic catcher 55x29 mm size for continuous opening and closing of doors shutter like use for door megnet lock, cupboard magnetic lock, wardrobe, and similar use incl all fitting like screw complete all as directed by Engr-in-Charge. |
| 17 | S&F solid PVC door frame of size 50mmx 47mm made out of 5mm wood grains printed PVC sheet reinforced with ms square tube and edges painted to match with printed sheet complete all as specified and directed |
| 18 | S&F factory made solid panel PVC door shutter 30 mm thick (styled) consisting of frame made out of MS tube for top & bottom rails, MS frame shall be covered with heat moulded wood grain colour PVC ,C\\" channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for styles and plain colour PVC sheet for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitable PVC sheet bedding and jointed together with solvent cement supplying and fixing in the frame at site all as specified and directed. |
| 19 | S&F of aluminium door / window / ventilator / partition, made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame & necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc, including powder coated aluminium fittings such as stainless steel hinges, tower bolts, hooks & eyes, peg stays and handles, concealed star lock for aluminium window, Mortice lock vertical type size 100mm 04 lever for door, rubber beading suitable for fixing 4mm / 5mm thick glass in aluminium window / doors including connected items, with and making good to the disturbed portion with its original specifications incl taking down existing members/frame any position complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L in repair 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on both side with decorative choice laminations fixed between aluminium section with and including snap fitting aluminium clips of polyester powder coated along with the glass with rubber gasket, complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F concealed star lock, powder coated for aluminium window fixed as per manufacturers instructions complete all as specified and directed. |
| 22 | M&L 4 mm thick plain sheet glass ordinary quality in any size, each pane fixed with rubber beading or oil putty for windows / doors / partition etc complete all as specified and directed. |
| 23 | S&F 4 mm thick Sheet glass, ordinary quality, ground or obscured or frosted, on one side and glazing in wooden, Aluminium, steel frame in square of any size complete all as specified and directed. |
| 24 | M&L Hacking out old broken glass ( any thickness, size, quality or description ) from wooden or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. |
| 25 | Supply and Fix 4 mm thick Figured glass, pin head type and glazing with oil putty in squares not exc. 0.5 sq. m in each pane, complete all as specified and directed by the Engr-in-Charge. |
| 26 | S&F for rubber beading suitable for fixing 4mm/ 5mm thick glass in aluminium window / doors etc complete all as specified and as directed. |
| 27 | S&F in repair aluminium anodized grill of design DG 104 pattern made out of 10mm dia rod Fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm &1.4mm thick all as per manufactures instructions complete all as directed by Engr-in-Charge (Make of grill Deco grill or equivalent). |
| 28 | S&F in repair for aluminium (extruded section) body hydraulically regaulted door closer, designation No.3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and as directed. |
| 29 | S&F in repair for Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy Each sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other plart made of mild steel heavy duty and fixed, complete all as specified and directed |
| 30 | S&F in repair aluminium alloy wire cloth, 0.45mm dia of wire and average width of aperture 1.40mm and fixed with aluminium staples as fixed in repairs complete all as specified and as directed |
| 31 | S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed |
| 32 | Supply and Fix in repair stainless steel bright polished Handle, 10mm dia of shoot and 200mm long complete all as specified and directed |
| 33 | S&F extruded aluminium alloy handles fabricated type anodized 150 mm size, complete all as specified and directed. |
| 34 | S&F 125mm size stainless steel Butt hinges medium weight, cold rolled and fixed, complete all as specified and as directed. |
| 35 | S&F 100mm size butt hinges extruded aluminium alloy with galvanised mild steel hinges pin anodised and fixed C-21, complete all as specified and as directed. |
| 36 | S&F 200 mm stainless steel barrel tower bolts of extruded section and fixed to shutter complete all as specified and as directed by Engineer-in-Charge. |
| 37 | S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed to shutter complete all as specified and as directed by Engineer-in-Charge. |
| 38 | S&F in repair 250mm dia Stainless steel sliding door bolts, Clip type with bright bolt not less than 12mm dia with a minimum of 6 bolts and nuts, four on bolt plate and two on stapple plate complete all as specified by Engineer-in -Charge. |
| 39 | S&F in repair 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed |
| 40 | S&F 150 mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed by Engr-in-Charge |
| 41 | S&F Extruded brass handles, fabricated type polished size of handle 150 mm complete all as specified and as directed. |
| 42 | S&F in repair 250 mm Brass sliding door bolt with sand or die-cast brass hasp,staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed, complete all as specified and directed |
| 43 | S&F two legged aluminium floor door stopper with rubber shoe 140mm long complete all as specified and directed. |
| 44 | S&F in repair 12 mm thick vertical toughened glass including frame as in door shutters / partition with including stainless steel SS-304 patch fitting fixed with Anchor fastner, etching, pivot arrangements complete each glass panes shall be exceeding 1.5 sqm, but not exceeding 2 sqm each, all edges of glass shall be diamond polished, accurate designed holes to be installed by means of steel fittings including upper patch, lower patch, lock key plate, provision of locking system, etc. Including providing \\"PUSH\\" & \\"PULL\\" sticker lables of approved design (as per site requirement). complete all as specified and as directed by Engr-in-Charge. |
| 45 | All as per item No 44 hereinbefore but 12mm thick fully/ partily (as per site requirement) frosted high quality toughened glass with unit colour digital logo and other design / pattern like text in hindi / english furnished by Engr-in-Charge, colour of digital logo / pattern and matter will be furnished by Engr-in-Charge. |
| 46 | S&F in repair 25-30 mm dia stainless steel handle of 40-45 cm long and fixed to toughned glass as per manufacturer's instructions complete all as specified and as directed. |
| 47 | S&F in repair stainless steel glass lock of suitable size fixed to toughened glass as per manufacturer's instructions complete all as specified and as directed. |
| 48 | S&F in repair stainless steel cylindrical lock / knob lock, with 3 brass keys, 60 mm backset, complete all as specified and directed |
| 49 | S&F in repair blinds for windows / door / ventilator of any colour and pattern as approved including connected items ie. chain control, rod, hook etc and complete fitting complete all as specified and as directed by Engineer-in-Charge. |
| 50 | M&L in repair fabrication of Aluminium Composite Panel of 5mm thick with 0.5 mm aluminium core/skin as a top and bottom layer, middle layer 3mm thick of polythincore (LDPE) and finally with PVDF coating 28 to 32 micron and joints filed with silicon sealant and including aluminium frame of required section fixed on the wall/ columns as a cladding and on ceiling of steel structure/ RCC celing withscrew complete incl dismantling of old decayed panels completeall as directed and as per manufacture's instruction, coloured / texture pattern as decided by Engr-in-Charge. |
| 51 | M & L for preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 52 | Material and Labour Preparation of old wooden surfaces over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 53 | M&L for Petty repairs to taking down steel / wooden window / ventilator frame with shutters exc. 0.5 sqm but n. exc. 1.50 sqm each shutter, repairing, tightening of hinges or changing the position of hinges adjustment of tower bolts sliding bolt etc, replacement of minors such as screws, clamps, cleats etc and refixing in the same opening (no extra payment will be paid for external window shutters of upto 10th floor) complete all as specified and as directed by Engineer-in-Charge. |
| 54 | M&L for Petty repairs to taking down wooden/PVC door shutters exc. 1.5 sqm but n. exc. 4 Sqm each shutter, repairing, tightening of hinges or changing the position of hinges adjustment of tower bolts sliding bolt etc ,replacement of minor items such as screws, cleats, clamps etc and refixing on the same opening (no extra payment will be paid for welding of new hinges on steel chowkat frame) complete all as specified and as directed by Engineer-in-Charge. |
| 55 | Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar complete all as specified and directed. |
| 56 | M&L Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like laid over and including 15mm thick bedding layer in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed. |
| 57 | Dismantling of wall and ceiling boards or insulation boards, any thickness, any description, including cover fillets complete all as specified and directed |
| 58 | S&F 10 to 12mm thick plaster of paris sheets fix in ceiling with and including grid made out of angles and tees of one mm thick G I sheets fixed at not more than 45cm centre to centre in both directions. GrId secured by vertical tai of GI sheet angle at not more than 1.2m centre to centre in both directions. The veritical tai of GI sheet angle shall be fixed with M S dash through fastners of 8 mm dia. The ceiling is to be provided at different profiles like curved, flat, sunk, tapered edge and or raised mouding, the joints shall be filled with plaster of paries, necessary arrangement / cut outs hole (The area of these cutouts which is less than 0.60 Sqm for one unit will not be deducted while measuring the ceiling area) for ceiling light as required number included for all kinds of profiles and cut outs required for light fixtures, Speakers, Smoke detector, trap doors and AC grill in the ceiling incluidng provision for light fittings, AC grills and diffusers have to be made at supported with tees, Angles, etc. suitably fixed etc. complete all as specified and directed by Engineer-in-Charge. Notes:- (i). The quoted unit rate shall be deemed to include the cost of scaffolding, all necessary arrangements, and safety measures for work at any building height. No additional payment shall be admissible on this account.(ii). The contractor must co-ordinate with electrical & AC contractor for working out various levels for the false ceiling & make the marking on the walls / columns before starting the false ceiling work. |
| 59 | All as per item No. 58 but providing, making and fixing Gypsum cornice cove (inside height 150 - 200 mm and border 75 mm) or charcoal moulding strip to hide strip/cove light in ceiling or to act as pelmet for roller blinds on windows or for projector screen, etc. complete all as specified and directed by Engr-in-Charge. |
| 60 | M&L for preparing of new POP/ false ceiling surfaces and applying two coats royale luxury emulsion interior paint a luxurious smooth finish white or coloured over a coat of approved primer on walls or ceiling complete all as specified and as directed by Engineer-in-Charge. |
| 61 | S&F Decorative Hollow PVC sheet 10 mm thick (fluted panel) having density not less than 4 Kg/Sqm fixed to wall panelling with self drilling screws including necessary frame of aluminium section 51mm x 35mm x 0.55mm and 600 mm c/c 51mm x 32mm x 0.55mm grid work and corner mouldings as required as per manufacturing instruction complete all as specified and directed. |
| 62 | S&F 10-12 mm thick decorative solid charcoal fluted wall panels as per approved design specifications, fixed to wall / ceiling panelling with self drilling screws as per manufacturing instructions. The panels shall consist of durable materials infused with charcoal, exhibiting a fluted profile with uniform grooves for a textured, aesthetic finish. Panels shall be accurately sized and cut prior to installation, with all edges finished smoothly. Installation shall include precise alignment on wall substrates, secure fixing with approved adhesives, screws, channels, or concealed fasteners, and proper sealing at joints to accommodate minor thermal movements and prevent moisture ingress. Surface finish shall be uniform, free of visible defects, and resistant to moisture, termites, and wear, complete all as specified and directed |
| 63 | S&F in repairs back-painted toughened glass in wall panelling as per approved design specifications. It shall consist of 6mm thick toughened (tempered) glass with a factory-applied back-painted finish in the specified color. Panels must be accurately cut and finished before toughening, with all edges polished to safety standards. Installation shall include precise alignment on wall substrates, secure fixing using approved clamps, channels, or adhesive as specified, and proper sealing at joints to allow for thermal expansion and prevent ingress of moisture. All work shall ensure a smooth, glossy, and uniform color surface with no visible defects, complete as per manufacturing instruction and all as specified and directed by Engr-in-Charge. |
| 64 | S&F in repairs decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions, complete all as specified and diretced by Engr-in-Charge |
| 65 | Supply and fixing in repairs, high-quality decorative fabric in wall panelling. Fabric to be free from defects, colorfast, and suitable for interior wall application, including padding or foam backing as specified, ensuring smooth, wrinkle-free finish. Edges shall be neatly folded and secured. Adhesives, pins, or staples to comply with manufacturer's recommendations. All seams to be aligned and invisible, complete all as directed by Engr-in-Charge. |
| 66 | M&L for providing and fixing fluted solid wood veneered wall panels as per approved design specifications. The panels shall consist of a 4mm thick natural or dyed wood veneer bonded over a high-quality MDF or WPC core, machine-processed to form a fluted texture pattern. The installation shall include alignment of flutes, jointing, adhesive application, and securing panels to wall substrates using approved fixtures, ensuring a smooth, tight fit with uniform pattern continuity. All surfaces shall be finished with primer or sealant as specified, ready to receive polish, lacquer, or protective coating. Surface finish shall be uniform, free of visible defects, and resistant to moisture, termites, and wear. The work shall include cutting around openings (doors, windows, electrical points), all necessary surface preparation, and materials required for a complete and functional installation etc complete all as directed by Engr-in-Charge. |
| 67 | M&L in repairs for fixing framework of aluminium section 50x25x1.2 mm or 25x25x1.2 mm at 600 mm c/c grid work and corner mouldings as required as per manufacturing instruction complete all as specified and directed |
| 68 | S&F in repairs 12 mm thick Plywood, grade BWP, type BB, fixed with fevicol or screws to aluminium frame work, complete all as specified and directed |
| 69 | Supply and laying of commercial-grade Carpet, anti-microbial and stain-resistant, minimum 4mm thick, color/pattern as per design, including seam finishing and edge binding, over prepared office floor, including taking down of old existing carpet complete all as directed by Engr-in-Charge. |
| 70 | M&L for providing and fixing factory-finished polyester fiber acoustic panel boards on wall surfaces, made from high-density (2400g/sqm) mineral/wood fiber with NRC (Noise Reduction Coefficient) not less than 0.85, thickness 12-15 mm, edges square/beveled as specified, mounted on suitable framework with concealed fasteners. Panels to be fire-retardant (Class 1/Class A), moisture-resistant, and finished in approved shade/texture, including taking down of old existing panels, complete all as directed by Engr-in-Charge. |
| 71 | Supply and Fix door frame made from seasoned teak or equivalent high-grade hardwood, kiln-dried to maintain dimensional stability and treated for termite and moisture resistance, minimum section 120 × 70 mm, reinforced with concealed steel rods, complete all as specified and directed by the Engr-in-Charge. |
| 72 | Supply and Fix premium handcrafted antique-style heavy-duty door shutter made from seasoned teak or equivalent high-grade hardwood, kiln-dried to maintain dimensional stability and treated for termite and moisture resistance. The shutter thickness shall be 50 mm with double-panel construction and cross-bracing for rigidity. Traditional mortise-and-tenon joinery, dowelled reinforcement, and resin bonding are required to ensure long-term durability. The door surface shall feature deep-relief hand-carvings inspired by temple architecture, including motifs such as lotus, peacock, or geometric latticework, each panel requiring extensive artisan labor. The finish shall be multi-layered antique patina achieved through natural oils, wax polish, and distressing techniques to replicate centuries-old heritage doors, complemented by custom-forged brass hardware in antique finish for hinges, locks, and handles. Protective treatments shall include eco-friendly termite resistance, marine-grade coatings for moisture and UV protection, and integrated weatherstrips for exterior durability. Aesthetic detailing shall include ornamental studs, beveled edges, burnished accents, and rich golden-brown teak tones with darker shading for depth. Installation shall be carried out with stainless steel fasteners and chemical grout, ensuring plumb, level, and square alignment. The contractor shall provide samples of carving and finish for approval, submit shop drawings prior to fabrication, and guarantee a minimum 10-year warranty against termite, warping, and joint failure, complete all as directed by the Engr-in-Charge. |
| 73 | Demolition of brick work built in cement mortar including all qoins, arches, pillars, etc.complete all as specified and directed by Engr-in-Charge. |
| 74 | M&L for Brick work with sub class B bricks straight or curved on plan exc. 6.0m mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge. |
| 75 | All as per srl item No. 74 here in before but except bricks complete all as directed by Engr-in-Charge.Note:- Serviceable bricks obatined from srl item No. 73 shall be re-used after cleaning etc complete all as specified and directed by Engr-in-Charge. |
| 76 | Demolition of pre-cast concrete block masonary built in cement mortar including all quoins, arches, pillars etc. and pre cast concrete articles complete all as specified and directed. |
| 77 | M&L for pre-cast cement concrete block masonry with solid blocks in 10cm in width in type B1 1:2:4 (20mm graded aggregate) and setting in mortar (1:6) complete all as specified and as directed |
| 78 | Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debries directed for a distance max upto 500m complete all as specified and directed |
| 79 | M&L for rendering 15mm thick on fair faces of brick/concrete surfaces of walls in CM (1:4), finished even and smooth without using extra cementmixed with WPC complete all as specified and directed.Note:- WPC shall be measured and paid separetely. |
| 80 | Supply only liquid water proofing liquid compound complete all as specified and directed. |
| 81 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished even and smooth with out using extra cement complete all as specified and directed |
| 82 | M&L for rendering 5 mm thick on ceilings in CM 1:3 and finishing the surface even and smooth without using extra cement complete all as specified and directed |
| 83 | M&L for three coats of white wash on newly plastered surfaces of ceilings including preparation of surface complete all as specified and directed |
| 84 | M & L for preparation of new or previously untreated plastered surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer complete all as specified and as directed |
| 85 | M&L for preparation of new plastered surfaces on walls of any description not otherwise described over 10cm width or girth and applying two coats of oil bound distemper over a coat of alkali resistant primer, complete all as specified and directed |
| 86 | M&L for Complete removal of existing treatment from old decorated plastered surfaces of walls & ceilings by Vacuum based sanding machine, removal of nails etc & filling cracks / hole with putty, applying wall care putty upto 2 mm thick (multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coats of oil emulsion distemper white or coloured over a coat of approved primer by auto roller complete all as specified & directed. |
| 87 | M&L for complete removal of Old Decorated surfaces of walls and applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern on one coat of primer complete all as specified and as directed |
| 88 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and removal of debries outside the MD land complete all as specified and directed by Engr-in-Charge. |
| 89 | M&L for glazed ceramic coloured tile 350x250x7 or 450x350x7mm size as in walls set and jointed in neat cement slurry over 10mm thick cement mortar (1:4) and pointed in coloured cement to match for work on vertical surface etc complete all as specified and as directed by Engr-in-Charge.Note:- Designer concept tiles matching with existing tiles. |
| 90 | M&L for non skid ceramic coloured tile 7 to 8mm thick (square/rectangular area of each tiles exceeding 0.18 sqm but not exceeding 0.38 Sqm in floor laid over and including 15 mm thick screed bed in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the tile complete all as directed by Engr-in-Charge. |
| 91 | M&L for Vitrified ceramic coloured light shade tiles 10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of 15mm thick in CM 1:4 for laying floor finishes complete all as specified and directed by Engineer-in-Charge |
| 92 | M&L for Vitrified ceramic coloured light shade tiles 10mm thick such as skirting, dado, on walls etc jointed in neat cement slurry over 10mm thick in cement mortar (1:3) pointed in white or coloured cement complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |