| 1 | M & L for painting carefully (by taking necessary shut down from respective sub-station) on steel tubular poles 9 m hi from (above grnd 7.5RM) upto top of the pole, including cross arms, bracings, clamps, cable protection pipes, street lig clamps & pipe (fix to poles) with two coats of 1st quality aluminium paint after preparation of surface by wire brush a painting with two coats of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing Pole No. of suitable size of letters as directed.Note: Size of lettering and colours of paints will be directed by Engr-in-charge. |
| 2 | M & L for painting carefully (by taking necessary shut down from respective sub-station) on LT PCC Pole 9 m high from (above grnd 7.5 RM) upto top of the pole, applying two coats of cement base paint over a coat of alkalines resista primer to surface of concrete pole with cement based paint after preparation of surfaces of poles including cross arm bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality of synthet enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing Pole N of suitable size of letters as directed.Note: Size of lettering and colours of paints will be directed by Engr-in-charge. |
| 3 | M&L for cutting/trimming the trees branches size n.exc 80 mm dia at height of exc. 3 mtrs but not exc 12 mt crossing/touching/embracing the overhead lines of HT/LT and obstructing the uniform electric power supply inc Removing the same from site to a distance exceeding 50 mtrs. complete all as specified and directed. |
| 4 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe cable etc or n. exc. 10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and gettin out in any type soft/loose of soil complete all as specified and directed. |
| 5 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 6 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point including spreading complete all as specified and directed. |
| 7 | Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cabl for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gentl punned down to 18cm thickness complete all as specified and as directed. |
| 8 | Supply & laying dry bricks over cable as mechanical protection layed flat with width equal to length of brick with sull class 'B' bricks complete all as specifieds and directed. |
| 9 | M & L for Gl pipe crossing hole under road/hard stranding for passing cable through including Gl pipe light grade 32 mm dia with all fittings. |
| 10 | -ditto- as above but of size 40 mm dia complete all as directed. |
| 11 | -ditto- as above but of size 50 mm dia complete all as directed. |
| 12 | -ditto- as above but of size 80 mm dia complete all as directed. |
| 13 | Taking down existing old Existing unserviceable LT UG/service cable of any description and size complete all as specified and directed. |
| 14 | S& F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 1100 volt grade laid in tranches passing through pipes/ducts including testing complete of following cross sectional area and size note-rate is inclusive of cable gland & cable lugs. |
| 15 | 3.5 core x 240 Sqmm |
| 16 | 3.5 core x 240 Sqmm |
| 17 | 3.5 core x 240 Sqmm |
| 18 | 3.5 core x 240 Sqmm |
| 19 | 3.5 core x 240 Sqmm |
| 20 | 3.5 core x 240 Sqmm |
| 21 | 3.5 core x 240 Sqmm |
| 22 | 3.5 core x 240 Sqmm |
| 23 | 3.5 core x 240 Sqmm |
| 24 | 3.5 core x 240 Sqmm |
| 25 | 3.5 core x 240 Sqmm |
| 26 | 3.5 core x 240 Sqmm |
| 27 | 3.5 core x 240 Sqmm |
| 28 | Supply and fixing in replacement of unsv MCCB 63 Amp 4 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed. |
| 29 | Supply and fixing in replacement of unsv MCCB 100 Amp 4 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed. |
| 30 | Supply and fixing in replacement of unsv MCCB 160 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed. |
| 31 | Supply and fixing in replacement of unsv MCCB 200 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed. |
| 32 | Supply and fixing in replacement of unsv MCCB 350 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed. |
| 33 | Supply and fixing in replacement of unsv MCCB 400 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu, conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed. |
| 34 | Supply and fixing in replacement of unsv MCCB 630 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu, conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection outgoing and incoming spreaders should be provided for connecting cable without any extra cost complte all as specified and directed. |
| 35 | Supply & fixing of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box conforming to IP 54.the contactor, MCBs and copper circuit wiring (min. 16sqmm) should enough to take: three-phase load of 12KW;contactor Rating 25Amps; MCB(spn) Rating 32 Amps. |
| 36 | Supply & fixing of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box conforming to IP 54.the contactor, MCBs and copper circuit wiring (min.10sqmm) should enough to take: Single-phase load of 5KW; contactor Rating 25 Amps; MCB(sp) Rating 32 Amps. |
| 37 | Supply and fixing thermoplastic polystyrene/ polycarbonate enclosure shock proof, IP 65 (weather proof) rust proof, dust proof, water proof, internally embedde gasket with provision for all side cable entry throught gland(IP-65) and/or gromments (IP-55) size of enclosure (250x 200 x 105mm) with suitable connectors for/3 phse loop in loop out and branch out vibration proof connections and fixing on PCC/Steel poles with 25 x 3 mm thich 02 Nos of clamp with nuts bolts and washers and proper timbling complete. |
| 38 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics incl brackets for fixing complete with IP 65/66 protection complete and taking down old unsv street light fitting and type and any wattage complete all as specified and directed.all as specified and directed. |
| 39 | Supply and fixing LED street light fitting 60 watt 230V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complet with driver, lamp bracket with impact and corrosion resistant including thermal mangement in multiple optics compete with IP 65/66 protection complete and taking down old unsv street light fitting and type and any wattage complete all as specified and directed. |
| 40 | Material and labour in replacement for LED Street lighting 90W LED IP66 New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium with lens and toughened glass type roadway luminaire with high power LEDs as light source including electronic driver 90W LED 6000K complete all as specified and directed. |
| 41 | Supply and fixing of LED flood light fitting 70 watt 230V AC outdoor type with thermal mangement in multiple optics and equipped with IP66 protection with impact corrosion resistant complete with driver and lamp and taking down old unsv flood light fitting and type and any wattage complete all as specified and directed. |
| 42 | Material and labour in replacement for LED flood light 120W LED IP65 New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium with lens and toughened glass type with high power LEDs as specified and as directed. |
| 43 | M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including Gl earth wire of size 4.0 mm by means of bolts, nuts. check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection of Gl wire to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit iron frame Cl frame, Cl cover with provision of locking arrangement and 20 mm dia light grade Gl pipe from top edge of all as per Electrical plate No 3 of SSR part1 (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete any type of strata and testing complete including fill up the earth pit with soil for best result and removal (for LT panels).Note: Earth protection pipe & earthing wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor. |
| 44 | M & L for earthing complete with galvanized steel earth plate electrode 60cmx60 cmx 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including Gl steel strip of size 32 x 6 mm by means of bolts, nuts. check nuts, and washers of galvanized iron or steel including 40 mm dia medium grade pipe for protection of Gl strip to the extent of 7.5 mtrs as earthing lead including charcoal dust and salt packed all around the earth piate in the earth pit all as per Electrical plate No 3 of SSR par - 1 (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame Cl frame, Cl cover with provision of locking arrangement and 20 mm dia light grade Gl pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil forEacbest result and removal (for LT Panels). Note:- Earth protection pipe & earthing strip upto and including 7.5 m length is deemed included in unit rate quoted by the contractor. |
| 45 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served wth inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart inccluding 4 mm susension wire, one twin core aluminium conductor of size 16 Sqmm flat or circular from junction box to street light fitting complete all as specified and directed by engr in charge. |
| 46 | M&L for boring of holes under road/pavement /hard standing by trenchless technology with neccessary machineries for inserting the Gl pipe of size upto 80 mm working pressuredia all as directed. |
| 47 | Strip open street light/flood light/Garden Light fittings for use with LED lamps of any size/capacity upto 200 Watts, dismantle and taking out unserviceable items by testing, cleaning, reassemble the fittings after replacing the unserviceable items and remounting on pole/original location complete all as directed. (Note: Items required to be replaced measured and paid separately.) |
| 48 | Supply and fixing against Item No. 34 the following Items :- |
| 49 | (a) Electronic driver suitable for LED street light/flood light of capacity upto 90 Watts of any make. |
| 50 | (a) Electronic driver suitable for LED street light/flood light of capacity upto 100 to 200 Watts of any make. |
| 51 | Taking down of Old MCCB of capacity 63 A to 630 A of any type/capacity |
| 52 | Taking down of old street/flood lights of any type/capacapacity all as specified and direceted. |
| 53 | Material and labour in replacement for LIARA Bollard light 10 Watts, 240 Volts, IP 66, die cast aluminium housing powder coated housing with frosted PC diffuser complete inluding fixing using metal sleeve anchor fastners and bolts of suitable size and quantity to be fixed in concrete all as specified. |
| 54 | S&F post top lantern LED type 40 Watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. |
| 55 | S&F multi core round PVC insulated aluminium conductor (flexible) industrial cable PVC sheathed cables, 1100 volts confirming to IS: 694 of size 2.5Sqmm, 3 core from junction box/overhead conductor to street light inside/outside pole complete all as specified and directed |
| 56 | Material and labour for Bus bar chamber of Size 750 x 600 x 500 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete with openable shutter in front and rear having proper locking arrangement, duly powder coated with 350 Amp 430 V 4 pole, 36 KA MCCB as incommer control and including 400 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase with neutral, 415 volts, 50Hz AC supply including control wiring to panel with suitable Size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50 x 50 x 6 mm including necessary PCC foundation work in all respect with phase indicator lamps (R, Y, B) - 1 Set complete all as specified. |
| 57 | Material and labour for Bus bar chamber of Size 700 x 550 x 480 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete with openable shutter in front and rear having proper locking arrangement, duly powder coated with 250 Amp 430 V 4 pole, 36 KA MCCB as incommer control and including 300 Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase with neutral, 415 volts, 50Hz AC supply including control wiring to panel with suitable Size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50 x 50 x 6 mm including necessary PCC foundation work in all respect with phase indicator lamps (R, Y, B) - 1 Set complete all as specified. |
| 58 | M & L for Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc complete all as specified and directed |
| 59 | M & L for Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping of poles etc including necessary form work complete all as specified. |
| 60 | M & L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) in stay assy, filling and mass concrete all as specified and directed. |
| 61 | M & L for cable jointing kit outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 10 to 16 Sqmm 4/3.5 core cables all as directed and specified. |
| 62 | M & L for cable jointing kit outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 25 to 35 Sqmm 4/3.5 core cables all as directed and specified. |
| 63 | M & L for cable jointing kit outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 50 Sqmm 4/3.5 core cables all as directed and specified. |
| 64 | M & L for cable jointing kit outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 70 Sqmm 3.5 core cables all as directed and specified. |
| 65 | M & L for cable jointing kit outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 95Sqmm 3.5 core cables all as directed and specified. |
| 66 | M & L for cable jointing kit outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 120 to 150 Sqmm 3.5 core cables all as directed and specified. |
| 67 | M & L for cable jointing kit outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 185 Sqmm 3.5 core cables all as directed and specified. |
| 68 | M & L for cable jointing kit outdoor type, heat shrinkable type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 240 Sqmm 3.5 core cables all as directed and specified. |
| 69 | M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25X4 mm dia galvanised iron strip. |
| 70 | Supply and fixing in replacement of Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal Red colour and inclusive fixed with MS flat clamps 25x3mm 2 Nos, nuts, bolts for LT 440 volt of size 20x15 cm all as specified and directed. |
| 71 | Supply and fixing in replacement of anti climbing device, spikes type, fabricated out of MS bars (round, square or flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the poles, spike welded to flat iron, including on primer coat, one under coat and two finishing coats of silver aluminium paint including preparation of surfaces. |
| 72 | Supply & fixing in replacement of onload change over switch 63 Amp, 4 pole, 415V AC, front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc of required capacity and of following cap:- (Make C&S/L&T/Havells/Indo-asian) (a). Change over switch |
| 73 | Supply & fixing in replacement of onload change over switch 100 Amp, 4 pole, 415V AC, front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc of required capacity and of following cap:- (Make C&S/L&T/Havells/Indo-asian) (a). Change over switch |
| 74 | Supply & fixing in replacement of onload change over switch 160 Amp, 4 pole, 415V AC, front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc of required capacity complete all as specified and directed. |
| 75 | Supply & fixing in replacement of onload change over switch 250 Amp, 4 pole, 415V AC, front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc of required capacity complete all as specified and directed. |
| 76 | Material and labour for replacement of unserviceable street light bracket made out of Gl pipe 1.2 mtr long 40mm dia medium grade bent to shape as directed including MS clamps made out of 25mmX3mm flat iron for fixing bracket suitable for PCC/ street poles including nuts and bolts of required size including painting with one coat of aluminium paint over a coat of red oxide / primer all as directed incl taking down of old unsv bkt |
| 77 | Schedule of credit amount of Rs 2,42,002.00 to be deducted during AOC Please Enable Macros to View BoQ information |