| 1 | Excavation in trenches in soft / loose soil not exceeding 1.5 metre wide and not exc 1.5 metre in depth and getting out for taking out / laying of GI / CI pipe line and making bottom surfaces of excavation leveledand to a gradient complete all as specified and directed . |
| 2 | Returning, filling in trenches with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 3 | Removing surplus soil /spoil to a distance not exceeding 50 metre away and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 4 | Taking down or taking up GI pipe and Supply and laying in trenches GI tubing 'Medium grade' 80 mm bore, with all fittings complete all as specified and as directed. (Note: Excavation, returning filling & removing of earth work shall be measured and paid seperately). |
| 5 | Ditto all as per Item No. 4.00 above but 50mm bore complete all as specified and directed. |
| 6 | Ditto all as per Item No. 4.00 above but 40mm bore complete all as specified and directed. |
| 7 | Ditto all as per Item No. 4.00 above but 25mm bore complete all as specified and directed. |
| 8 | Ditto all as per Item No. 4.00 above but 20mm bore complete all as specified and directed. |
| 9 | Ditto all as per Item No. 4.00 above but 15mm bore complete all as specified and directed. |
| 10 | Taking up or down Cast Iron/ Ductile Iron water mains of size 250 mm bore, any class including all fittings, with spigot and socket ends and rubber gasket joints, complete all as specified and directed. (Note: Excavation, returning, filling and removing of earth works shall be measured and paid seperately) |
| 11 | Supply and laying in trenches of DI pipe K7 of size 250 mm bore, with tighten joint spigot and socket ends complete all as specified and as directed. (Note: Excavation, returning, filling and removing of earth works shall be measured and paid seperately). |
| 12 | Taking up or down Cast Iron/ Ductile Iron water mains of size 100mm bore, any class including all fittings, with spigot and socket ends and rubber gasket joints, complete all as specified and directed. (Note: Excavation, returning, filling and removing of earth works shall be measured and paid seperately) |
| 13 | Supply and laying in trenches of DI pipe K7 of size 100mm bore, with tighten joint spigot and socket ends complete all as specified and as directed. (Note: Excavation, returning, filling and removing of earth works shall be measured and paid seperately). |
| 14 | Taking up or down Cast Iron/ Ductile Iron water mains of size 150mm bore, any class (including all fittings), with spigot and socket ends and rubber gasket joints, complete all as specified and directed. (Note: Excavation, returning, filling and removing of earth works shall be measured and paid seperately) |
| 15 | Supply and laying in trenches of DI pipe K7 of size 150mm bore, with tighten joint spigot and socket ends complete all as specified and as directed. (Note: Excavation, returning, filling and removing of earth works shall be measured and paid seperately). |
| 16 | Cleaning of existing single socketed pipe joints, recovering lead, finding reason for leakage and Material and labour for run lead joints with all jointing materials such as Lead, rope manila etc as required at site.for following size of CI pipes :-(Note: Excavation, returning, filling and removing of earth works shall be measured and paid seperately) |
| 17 | 250mm dia CI pipe |
| 18 | 150mm dia CI pipe |
| 19 | 100mm dia CI pipe |
| 20 | M&L for CI specials any type spigot and socket ends or flanged pipe as required at site (such as bend, taper, Tee, socket etc) Socket end/ flanged as ordered of size up to 150mm.( as per requirement of site to rectify the leakage) including taking down old unserviceable one complete all as specified and directed. |
| 21 | Taking down old unserviceable CI special and supply and laying for DI specials any type spigot and socket ends or flanged pipe as required at site (such as bend, taper, Tee, socket etc) Socket end/ flanged as ordered of size 80mm to 250mm bore( as per requirement of site to rectify the leakage). |
| 22 | Taking down old unserviceable and Material and labour for flanged joints with all accessories such as MS nuts, bolts, washers, gaskets rubber or fiber board complete.for following sizes of CI/DI Pipes :- |
| 23 | 250mm dia CI/DI pipe |
| 24 | 150mm dia CI/DI pipe |
| 25 | 100mm dia CI/DI pipe |
| 26 | 80mm dia CI/DI pipe |
| 27 | S&F of Sluice valve, both end flanged with CI operating wheel, stain less steel spindle etcas per latest IS specification, Class PN - 1.6 including necessory jointing and jointing materials such as gasket, nuts, bolts, washer etc complete including taking out unserviceable sluice valve of following size:- |
| 28 | Sluice valve of size 100mm dia |
| 29 | Sluice valve of size 150mm dia |
| 30 | Sluice valve of size 80mm dia |
| 31 | Taking down old unserviceable sluice valve of dia 250mm and repair of Sluice valve with replacement of spindle, glanpacking , nuts, bolts etc to serviceable of sluice valve complete all as specified and directed. |
| 32 | Taking down old unserviceable sluice valve of dia 150mm and repair of Sluice valve with replacement of spindle, glanpacking , nuts, bolts etc to serviceable of sluice valve complete all as specified and directed. |
| 33 | Taking down old unserviceable sluice valve of dia 100mm and repair of Sluice valve with replacement of spindle, glanpacking , nuts, bolts etc to serviceable of sluice valve complete all as specified and directed. |
| 34 | Taking down old unserviceable gunmetal gate valve and Supply and fixing of GM gate valves with iron wheel head, screwed both ends for iron pipes of following sizes:- |
| 35 | 50mm dia gate valve |
| 36 | 40mm dia gate valve |
| 37 | 25mm dia gate valve |
| 38 | 20mm dia gate valve |
| 39 | 15mm dia gate valve Please Enable Macros to View BoQ information |
| 40 | 15mm dia gate valve Please Enable Macros to View BoQ information |