| 1 | Supply and laying XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of following size after taking down complete all as specified and directed by Engr-in-charge and directed as follows : |
| 2 | 10 Sqmm x 2 Core |
| 3 | 16 Sqmm x 2 Core |
| 4 | 25 Sqmm x 4 Core |
| 5 | 35 Sqmm x 3.5 Core |
| 6 | 50 sqmm x 3.5 core |
| 7 | 70 Sqmm x 3.5 Core |
| 8 | 95 Sqmm x 3.5 Core |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required above 35 sqmm upto 95 sqmm complete all as specified and as directed by Engr-in-charge. |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required upto 35 sqmm complete all as specified and as directed by Engr-in-charge. |
| 11 | M & L for Heat Shrinkable 1.1 KV XLPE Straight Joints of following size including taking down complete all as specified and directed by Engr-in-charge and directed as follows : |
| 12 | 10 sqmm to 50 sqmm size |
| 13 | 70 sqmm to 95 sqmm size |
| 14 | Arranging fault locating machine to locate the fault in underground electric power cable of any length & any type of 11 KV/1.1 KV grade HT/ LT cables & pin point the fault, it also include testing of the cable after locating fault and cutting the cable at Fault to fix the joint including excavation and earth wotrk in any type of soil complete Note : Cable joint shall be measured and paid separately under respective of Sch 'A' (ii) If fault is not rectifed within 24 hours after receivng message , the contractor shall be charged penalty for Rs 500/- per Hours & the same has been deducred from his account during RAR. |
| 15 | Supply & fixing in repair of moulded case circuit breaker four pole 400 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay incl replacement of lugs & disconnecting and taking out the old unservicable MCCB from panel/DBs/ etc complete all as specified and directed by Engr-in-charge and directed. |
| 16 | All as per item No 06 above but 250 amps 4 pole 36 KA Capacity 415V 50 Hz. |
| 17 | All as per item No 06 above but 200 amps 4 pole 36 KA Capacity 415V 50 Hz. |
| 18 | All as per item No 06 above but 100 amps 3 pole 16 KA Capacity 415V 50 Hz. |
| 19 | All as per item No 06 above but 125 amps 3 pole 16 KA Capacity 415V 50 Hz. |
| 20 | M&L for \\"B\\" Check DG set upto 15 KVA of any make by taking out U/S spares, Cleaning by brushing to remove dust including labour for Changing engine oil, coolant etc to max level, adjustment belt tension,Tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking electric connection, pollution level potentially tappet set desmantling DG for a complete service including turbo charger , injector pin, cylinder head and PT pump sevices For smooth functioning of DG Set ( Note :- Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured and paid separately under respective items) . |
| 21 | M&L for \\"B\\" Check DG set upto 30 KVA of any make DGRE RDC by taking out U/S spares, Cleaning by brushing to remove dust including labour for Changing engine oil, coolant etc to max level, adjustment belt tension,Tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking electric connection, pollution level potentially tappet set desmantling DG for a complete service including turbo charger , injector pin, cylinder head and PT pump sevices For smooth functioning of DG Set ( Note :- Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured and paid separately under respective items) . |
| 22 | M&L for \\"B\\" Check DG set upto 50 KVA of any make DGRE RDC by taking out U/S spares, Cleaning by brushing to remove dust including labour for Changing engine oil, coolant etc to max level, adjustment belt tension,Tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking electric connection, pollution level potentially tappet set desmantling DG for a complete service including turbo charger , injector pin, cylinder head and PT pump sevices For smooth functioning of DG Set ( Note :- Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured and paid separately under respective items) . |
| 23 | Material and Labour for repairing working of any part of following Spare parts ( Item No. 15 to 38). of DG set 15,30,50 KVA :- |
| 24 | V belt for fan/water pump assy |
| 25 | Air filter elements |
| 26 | Fuse base |
| 27 | oil Sump gasket |
| 28 | Air hose set with clamp |
| 29 | water temp switch |
| 30 | water temp gauge |
| 31 | oil filter |
| 32 | piston Assembly (one piston with ring) |
| 33 | fuel filter |
| 34 | Head Gasket |
| 35 | Injector sleeves |
| 36 | Injector sleeves 'O' Ring |
| 37 | cylinder liner |
| 38 | Cylinder head |
| 39 | Ring set |
| 40 | bearings |
| 41 | joint kit complete |
| 42 | starter key switch |
| 43 | Battery Terminal made of brass nut & bolt |
| 44 | fuel injection pump & nozzle |
| 45 | pipe (Fuel line) set |
| 46 | radiator hose pipe set |
| 47 | Supply only distilled water |
| 48 | Supply and filling of genuine coolant in 5 ltrs plastic sealed container for topping up in Radiator of DG set located at different locations as directed by Engr-in-Charge complete all as specified and as directed.(Note:- Coolant shall be supplied in sealed container only ) |
| 49 | Supply & filling of syenthetic Engine oil, multi grade premium Genuine oil in DG sets complete all as specified and as directed. (Note:- Engine oil shall be supplied in sealed container) |
| 50 | Material and labour for cleaning of silencer pipe, replace of exhaust manifold and removing of ropes and re-fixing of new ropes of 15KVA to 50 KVA DG Sets all as specified and directed by Engineer-in-charge. |
| 51 | Supply and fixing in replacement of SMF 12V, 180 AH Battery, QUANTA BATTERY with specifications as under:-Nominal voltage :-12 VoltsMake:- Amaron, Exide, Luminous |
| 52 | S & F in Replacement Battery Stand for Battery of MS fabricated of 2feet with wooden platform for placement of battery all as specified and direceted by engineer in charge. |
| 53 | M&L for taking down and servicing of radiator assembly DG Set 15 to 50 KVA Capacity and replacement of minor parts, de-scaling of tubes with chemical solution, welding/brazing leak testing including transportation to workshop and re-fixing after repairs and testing commissioning complete all as specified and directed by Engr-in-charge. |
| 54 | Cleaning of diesel tank of various capacity DG set inside/ out side of tank complete with drain out DHPP(N) and cleaning tank and applying two coats of synthetic enamel paint (1st grade quality) on out side of tank and refilling the DHPP(N) & testing complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |