| 1 | M & L for complete removal of existing treatment on wall/roof projections including facia, cornices etc at any height by scrapping with mechanical sander(having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7\\"/9\\" to make free from dust, loose paint etc by skilled labour complete all as specified and directed. |
| 2 | M & L for water proof cement based putty @1kg (undiluted) per sqm of average thickness 2mm over the plastered /old prepared painted surface of wall and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface :-Step 1: Mix the putty powder by adding water as manufacturer's instruction and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute.Step 2: Apply the first coat of the prepared mixer with the help of fully automatic airless spray machine/manually of putty application finishing the surface even and smooth in level without any undulations.Step 3: Allow 6-8 hrs time to dry the putty surface. |
| 3 | M & L for one coat of acrylic water based exterior grade primer @ 0.9litre(undiluted)/ 10 sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine and allow 6-8 hours to dry the surface for painting of subsequent coats complete all as specified and directed. |
| 4 | M & L for water based premium acrylic smooth exterior emulsion of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50, Antifungal/ Anti Algal properties in two coats not less than 1.79 litre(undiluted)/10 Sqm diluted with water as per manufacturer's instruction applied over primed surface with fully automatic airless spray machine of point application with a flow speed of minimum 1 litre per minute having a pressure of 3300PSI. Allow 6-8 hrs to dry the surface in between subsequent coats of paint complete all as specified and directed.Note :- 25 % of material shall be deposited in MES store at every qtrs before commencement of works and shall be issued to contractor as per requirement. |
| 5 | Notes for Ser item No 1 to 4 above :-The work for periodical services shall include the following and the rates quoted by the bidders shall include the same:-(a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE.(b) The contractor shall upload with the documents under cover I \\"Memoradum of Understanding\\" (MoU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be rejected.(c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective/Safety measures.(d) Removing of Nails, making good holes, cracks etc(e) Work in patches and in narrow/width, bands, cornices, pilasters etc and cutting in edge of line where necessary.(f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes.(g) Washing floors, cleaning glass, joinery, electric fittings, wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-charge.(h) Sample patch of 10 Sqm be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work.(j) The work can be carried out upto any height and rates shall be included in rate quoted by contractor. |
| 6 | M & L for Preparation of old painted wooden surfaces of any description not otherwise described over 10 cms width or girth including preparation of surface and applying one coat of synthetic enamel paint, including cleaning surfaces such as removing all splashes, drops, dirt and leaving premises in a clean state complete all as specified and directed |
| 7 | M & L for Preparation of old painted steel surfaces of any description not otherwise described over 10 cms width or girth including preparation of surface and applying one coat of synthetic enamel paint, including cleaning surfaces such as removing all splashes, drops, dirt and leaving premises in a clean state complete all as specified and directed |
| 8 | M & L for water proofing of exterior walls,including completeremoval of existing plaster including raking out joints and applying two coats of Acrylic polymer modified high performance coating (Smartcare Ultra Block 2K). The treatment shall be done from ground level and providing 15mm thick cement plaster in CM 1:4 finished even and smooth complete all as specified and directed. |
| 9 | M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick or concrete surfaces, as on external surface such as chajja, parapet, finished even and fair, including taking down old plaster complete all as specified and directed. |
| 10 | M&L for 15 mm thick rendering in ready mix plaster external cement mortar on fair faces of brick or concrete surfaces, as on external surface such as chajja, parapet, finished even and fair, including taking down old plaster complete all as specified and directed. |
| 11 | M&L for 15mm thick rendering in cement mortar 1:6 on fair faces of brick or concrete surfaces, as on internal surface finished even and smooth without using extra cement, including taking down old plaster complete all as specified and directed. |
| 12 | M&L for 5mm thick rendering in cement mortar 1:3 on fair faces as in ceiling surfaces finished even and smooth without using extra cement, including taking down old plaster complete all as specified and directed. |
| 13 | M&L for rendering 10mm thick on concrete in CM 1:3 in facia or edging of chajjas, ceiling and roof projection etc incl taking out praled off plaster/concrete and making good to cracked RCC surface in true line/shape by poviding PCC 1:2:4 type B1 using 20mm graded stone aggregate incl necessary formwork to thickness required at ground floor and first floor etc. finish surface even and fair, including taking down old plaster complete all as specified and directed.Note:- This rate will incl of scaffolding for single and double store incl making hole in brick and making good in cement mortar |
| 14 | Supply only Integral liquid waterproofing compound complete all as specified and directed |
| 15 | Taking down eaves gutter and rain water pipe any size any pattern , PVC/ AC pipe including all fittings ,heads shoes, bends etc including removal to store ,Internal dia of pipe in 75MM/110mm complete all as specified and directed. |
| 16 | S & F in repair 75 mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed, incl clamp with fittings fixed to wall, corner complete all as specified and directed. |
| 17 | Supplied and fixed PVC (SWR) bends 75 mm dia complete all as specified and directed. |
| 18 | S & F in repair 110mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed, incl clamp with fittings fixed to walls complete all as specified and directed. |
| 19 | S & F in PVC (SWR) bends 110 mm dia complete all as specified and directed. |
| 20 | M & L for repair of distrubed/ broken brick/stone/roof holes in walls/roof with CM 1:6 including filling of narrow interstices with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) after and including removal / root out of trees, plants, truncks, grasses and creeps etc from roof or wall, finished with 15 mm plaster in CM(1:6) including finishes the surface with same finish complete all as specified and directed. |
| 21 | M & L for one coat of white wash on old decorated surface of walls including preparation of old surface i.e brooming down with steel wire brushes scraping down moulds moss and efflorescent salts and treating oil and greasy spots, removing of nails, making good holes, cracks etc and washing floors, cleaning glass , joinery, electric fitting, etc complete all as specified and directed. |
| 22 | M & L for preparation of old plastered or un-plastered surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots remove complete existing surface up to mother surface approved by GE than applying one coat of cement base paint and making border or patta on Chhajja, roof projection Column projection , beam projection etc as ordered by Engr-in-Charge with teracotta snowcem dark colour,same materials but diffrent tinted on walls complete all as specified and directed.Note :- 25 % of material shall be deposited in MES store at every qtrs before commencement of works and shall be issued to contractor as per requirement. |
| 23 | M & L for preparation of old plastered/unplastered ceiling surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of white washing, complete all as specified and directed by Engineer in Charge. |
| 24 | M & L for Preparation of old plasteres/ unplastered wall surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of distemper oil emulsion, with sponge rollers\spray gun complete all as specified and directed.Note :- 25 % of material shall be deposited in MES store at every qtrs before commencement of works and shall be issued to contractor as per requirement. |
| 25 | M & L for Preparing wood surface for Varnishing incl cleaning and stoping and applying one coat of liquid transparent wood filler and finishing with a varnish coat complete all as specified and directed. |
| 26 | M & L for Preparing surface of tiles for Varnishing incl cleaning and stoping and applying one coat of varnish coat complete all as specified and directed. |
| 27 | Complete removal of existing treatment by mechanical means and preparation old wall surface and applying two coats of distemper oil emulsion, with sponge rollers/spray gun, over one coat of primer,over and including 2mm thick wall care putty complete all as specified and directed.Note :- 25 % of material shall be deposited in MES store at every qtrs before commencement of works and shall be issued to contractor as per requirement. |
| 28 | M & L for Preparation of old painted wood or wood based surfaces of any description not otherwise described and surface not exc 10 cms width or girth including preparation of surface and applying one coat of synthetic enamel paint on wooden surface complete all as specified and directed.Note :- 25 % of material shall be deposited in MES store at every qtrs before commencement of works and shall be issued to contractor as per requirement. |
| 29 | M & L for Preparing of newly plastered wall surface and applying two coat oil bound distemper on newly plastered surfaces incl 2mm thick wall care putty complete all as specified and directed. |
| 30 | M & L Preparing of new plastered ceiling surface and applying two coat white wash on newly plastered surfaces complete all as specified and directed. |
| 31 | M & L for Writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high on walls complete all as specified and directed by Engineer in Charge incl obliterating old writing of any description with paint to match existing work complete all as specified and directed. |
| 32 | S&F PVC(SWR) junction single Tee equal or unequal 110mm bore with access door complete all as specified and directed. |
| 33 | S&F PVC(SWR) junction single Tee equal or unequal 75mm bore with access door complete all as specified and directed. |
| 34 | M&L for 75 mm size PVC floor trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 complete including taking down old unserviceable floor trap complete all as specified and directed. |
| 35 | Demolition of brick or stone/boulder masonry built in CM including all quoins, arches, pillars etc but excluding ashlars facing dressed stones complete all as specified and directed. |
| 36 | M&L for Brick work sub class B brick straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 complete all as specified and directed. |
| 37 | Taking up or down steel tubing 25 or 32mm bore including cleaning for re-fixing or removing to store complete all as specified and directed. |
| 38 | Taking up or down steel tubing 20mm bore including cleaning for re-fixing or removing to store complete all as specified and directed. |
| 39 | S&F GI steel water tubing medium grade 25 mm bore as in any lengths with all fillings & fixed complete to walls or floor complete all as specified and directed. |
| 40 | S&F GI steel water tubing medium grade 20 mm bore as in any lengths with all fillings & fixed complete to walls or floor complete all as specified and directed. |
| 41 | M&L for Providing, cement concrete, in lintels upto 1.5m clear span, sills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed (Type B0 1:2:4 12.5mm graded aggregate) Please Enable Macros to View BoQ information |