| 1 | Surface Excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/ Loose soil complete all as specified and directed |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed |
| 3 | Excavating over areas, exc 1.5 m deep and not exc 3.0 m deep and getting out in soft/loose soil complete all as specified and directed |
| 4 | Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortor complete all as specified and directed |
| 5 | M & L for cement concrete 1:4:8 type D2 using 40 mm graded aggregate in foundations / fillings and mass concrete complete all as specified and directed |
| 6 | M&L for RCC Design mix M-25 as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 7 | M&L for reincorced cement concrete (RCC M-25) 20mm graded aggregate in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed |
| 8 | M&L for RCC Design mix M-25 as in floors, roofs, landings, deck slabs and in shelves complete all as specified and directed |
| 9 | M&L for RCC Design mix M-25 as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed |
| 10 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finishes complete all as specified and directed |
| 11 | M&l for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses etc.; vertical or to batter fair finishes complete all as specified and directed |
| 12 | M&l for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed |
| 13 | Formwork to edges of concrete flats treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm width rough finished surface of concrete complete all as specified and directed |
| 14 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splay between floors and beams, etc. and similar works for smooth finished surfaces complete all as specified and directed. |
| 15 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 16 | Ditto all as per item No 15 above, but 6 mm to 8 mm dia complete all as specified and directed. |
| 17 | M&L for Providing precast cement concrete 1:1.5:3, type A1 (20 mm graded aggregate) set in CM 1:6, as in cover slabs (for manhole, drains etc) with plain fair faces complete all as specified and directed |
| 18 | M & L for brick work using red brick conforming to IS-12894:2002, Non Modular, class designation 7.5, straight or curved on plan, exc 6.0 m mean radius, built in CM (1:4) including demolition complete all as specified and directed |
| 19 | M & L for Brickwork with fly ash bricks in one brick thick honey-comb walling, built in CM (1:3) complete all as specified and directed |
| 20 | Cutting into road/black top/PCC pavement of any thickness including excavation in any type of soil upto 0.50 m to 0.80 m width and 0.50m to 1.50m in depth,refilling,compaction of soil after laying of PCC bed,haunching and pipe and packing and compaction with existing soling/GSB/WBM/WMM and top surface prepared with 75mm thick cement conrete 1:2:4 type B-1 ( Using 20 mm graded aggregate) complete all as specified and directed. |
| 21 | M & for Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded granite stone aggregate) in and other similar bands, plinth courses, string courses, copings, kneelers, the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 22 | Providing and laying hard core broken stone/ boulders to gauge n exc 63 mm complete all as specified and directed |
| 23 | M&L for rendering/plaster by using ready mix mixture of thickness 12 mm to 15 mm on newly prepared surface and plastering the wall surface with white cement based polymer modified self curing mortar, complete all as specified and directed |
| 24 | Demoliton/breaking up of drain pipes of 150mm internal dia (salt glazed ware,AC or reinforced concrete) set in cement mortar and taking out off trenches and removing the debris from the site complete all as specified and as directed. |
| 25 | Demoliton/breaking up of drain pipes of 200mm internal dia (salt glazed ware,AC or reinforced concrete) set in cement mortar and taking out off trenches and removing the debris from the site complete all as specified and as directed |
| 26 | Demoliton/breaking up of drain pipes of 300mm internal dia (salt glazed ware,AC or reinforced concrete) set in cement mortar and taking out off trenches and removing the debris from the site complete all as specified and as directed |
| 27 | S&F DWC (Double wall corrugated) 150 mm dia pipes manufactured as per IS-16098(part-2) having internal surface smooth and external corrugated surface of SN 4 stiffness laid and jointed complete all as specified and as directed |
| 28 | S&F DWC (Double wall corrugated) 200 mm dia pipes manufactured as per IS-16098(part-2) having internal surface smooth and external corrugated surface of SN 4 stiffness laid and jointed complete all as specified and as directed |
| 29 | S&F DWC (Double wall corrugated) 300 mm dia pipes manufactured as per IS-16098(part-2) having internal surface smooth and external corrugated surface of SN 4 stiffness laid and jointed complete all as specified and as directed |
| 30 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) incement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 100/150/200 mm internal dia of pipe complete all as specified and as directed |
| 31 | Returning / filling in layers including spreding, leveling, watering and well ramming in layers not exc 25cm each complete all as specified and directed |
| 32 | Removing excavated earth not exc 50 m and depositing whereas directed as a level n, exc 1.5m above the starting point complete all as specified and directed |
| 33 | S&F in repair of PVC (SWR) vent cowls suitable for 110mm bore pipes complete all as specified and directed. |
| 34 | S &F Framed work such as grills, gratings,jallis etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 incl taking down of existing complete all as specified and directed. |
| 35 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed |
| 36 | M&L for Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and directed |
| 37 | M & L for 75mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base etc.including demolition of Cement concrete (unreinforcde) in ground floor and paving n exc 15cm thicknes and below or above ground level complete all as specified and directed |
| 38 | M & L Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in with grey cement & no pigments over Screed bed or bedding layer of mortar 15 mm thick in Cement mortar 1: 4 for laying floor finishes incl demolition of existing stone/tiles etc complete all as specified and directed. |
| 39 | M&L for Providing and laying 60mm thick factorymade chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,ength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern incl demolition of existing stone/tiles etc complete all as specified and directed |
| 40 | Supply and fixing of 25 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc.including Cutting and chaseing in brick wall for concealed GI tubing and making good in CM 1:4 n.exc 10 cm in girth fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing complete all as specified and directed. |
| 41 | M & L for Preparation of new plaster surfaces of wall and applying two coats of cement base paint complete all as specified as directed. |
| 42 | M & L for Preparation of new painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one primer over two of synthetic enamel paint complete all as specified and directed |
| 43 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed |
| 44 | S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed |
| 45 | S & F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified and directed |
| 46 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed |
| 47 | M & L 50mm thick Cement concrete type C1 1:3:6 (using 20mm graded granite stone aggregate) in plinth protection looring/ hard standing finishing the surface even and smooth using extra cement including demolition of cement concrete (unreinforeced) complete all as specified and directed |
| 48 | S&F of cook house stainless steel openable cover top grease trap of grade-304 ,2.0 mm thickness of size 3.0 mtrx1.50 mtrx 0.90 mtr including inlet/oulet of dia 100/150 mm with 03 partition chamber of stainless steel MH cover of size 0.90x0.90 with hinge consists of waste screening chmaber,sludge collection chmaber and waste/sludge removal chamber etc complete including connections and installation at site complete all as specified and directed Please Enable Macros to View BoQ information |