| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Naintal or similar pattern roof coverings complete all as specified and directed. |
| 2 | Dismantling timber scantlings 40 sq. cm and over in section in framed work, in any positionin any position complete all as specified and directed. |
| 3 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and directed. |
| 4 | Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each but with shutter (without taking off shutter from the frame) and removing to store complete all as specified and directed . |
| 5 | Taking down shutters of any description exceeding 1 Sqm but not exc 2.0 Sqm each complete all as specified and as directed. |
| 6 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) complete all as specified and directed. |
| 7 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed. |
| 8 | Taking down cement plaster any description from roof slab, stone wall, brick wall parapets including raking out joints hacking for key and scrubbing down with water etc (for roof treatment) Complete all as specified . |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr in Charge. |
| 10 | S & F Rolled Mild Steel sections confirming to Fe 410-W (Gde-E-250) quality 'A' as in main and cross beams, hip and jack rafters; purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as specified and directed by engr in charge. |
| 11 | M & L for 0.63 mm galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in lieu of screws etc Complete all as specified and as directed by Engr-in-charge. |
| 12 | M & L for 0.63 mm galvanised, Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 Complete all as specified and as directed by Engr-in-charge. |
| 13 | M & L for precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed. |
| 14 | M&L For RCC 1:2:4 type B-1, ( using 20 mm graded stone aggregate ) as in beams, cantilevers, bed block, bressummers, lintels over 1.5m span , including necessary form work etc Complete al as specified and as directed. |
| 15 | M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, bands, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished flat surface of concrete complete all as specified and directed. |
| 16 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 17 | M & L for mild steel TMT bars 5 mm dia and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 18 | M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish the surface even and smooth without using extra cement all as specified and as directed by Engineer-In-Charge. |
| 19 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement. |
| 20 | M&L preparing newly plastered surfaces of wall and applying complete wall with 1.5 mm Wall putty and making smooth surfaces and applying two coats of Oil bound distemper over a coat of primer all as specified and directed by Engineer-in-Charge. |
| 21 | M & L preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls over one coat of white wash complete all as specified and directed by engr in charge. |
| 22 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing & finished the surface even & fair all as specified. |
| 23 | M & L for PCC 1:2:4 type B-1, 25 mm thick, using 20mm graded stone aggregate as in flooring finishing surface even and smooth without using extra cement all as specified and directed. |
| 24 | M & L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed. |
| 25 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. complete all as specified and directed by Engr in charge. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 26 | M&L for glazed ceramic coloured tiles in verticle surface 300x 450x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engr in charge. Notes : Shade of the tile including colour, design and pattern shall be approved by AGE. |
| 27 | M&L for Chequered cement concrete tiles 25mm thick with grey cement and pigment set and jointed in neat cement slurry and pointed in white or coloured cement incl 15mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed by Engr-in-charge. |
| 28 | M & L for providing cement concrete cas in situ 1:2:4, type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edge including use of formwork complete all as specified and directed by engr in charge. |
| 29 | S&F pressed steel frames 105x60mm for doors with one or more rebates including necessary fixing lugs, lock strike plate, etc.,complete all as specified and directed by engr in charge. |
| 30 | S & F factory made solid PVC moulded door shutter, 30 mm thick 2mm thick 3D wood grain Moulded PVC sheet polyurethane painted on the front face & 2mm plain colour PVC sheet on back face complete all as specified and as directed. |
| 31 | S & F Mild steel butt hinges medium weight , cold rolled, 100mm, ISI marked, complete all as specified and as directed by Engr-in-charge. |
| 32 | M&L Aluminium anodised, barrel tower bolts of extruded section and fixed of size 200 mm complete all as specified and as directed by Engr-in-charge. |
| 33 | S&F 150 mm long aluminium anodised handles or extruded section complete all as specified and directed. |
| 34 | S&F 300mm long Aluninium alloy, anodised , sliding door bolt with hasp , staple,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 35 | S&F for 1000 ltr. Capacity rotational moulded polyethylene water storage tanks cylindrical vertical with closed top) hoisted and fixed in position including all fittings incl dismantling of old unsv tank complete all as specified in SSR Part I complete all as specified and directed. |
| 36 | S&F for 2000 ltr. Capacity rotational moulded polyethylene water storage tanks cylindrical vertical with closed top) hoisted and fixed in position including all fittings incl dismantling of old unsv tank complete all as specified in SSR Part I complete all as specified and directed. |
| 37 | M&L 20mm bore dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 38 | S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by engr in charge. |
| 39 | M & L Preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 40 | S&F For Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel,complete all as specified and directed by Engr in charge. |
| 41 | S&F For 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by engr in charge. |
| 42 | Taking up or down 15mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by engr in charge. |
| 43 | Taking up or down 20m bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed by engr in charge. |
| 44 | S&F 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed by engr in charge. |
| 45 | S&F 20mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed by engr in charge. |
| 46 | S&F in repair vitreous china wash basin , white , flat back, size 550 x 400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets , waste coupling complete all as specified and directed by engr in charge. |
| 47 | S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed by engr in charge. |
| 48 | S&F in repair 15mm fancy type bib tap long body, chromium plated with crutch or butterfly handle, screwed down , screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 49 | S&Fin repairs pillar taps cast copper alloy capstan heads, chromium plated, screwed down high pressure with or without lettered hot or Cold with long screwed shank and fly nuts screwed for iron pipe and fixed bore of pipe 15mm complete all as specified and direrected. |
| 50 | S&F in repair 15mm dia stop valve / Angle valve chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union complete all as specified and directed by engr in charge. |
| 51 | S&F 110mm PVC(SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by Engr in charge. |
| 52 | S&F 75mm PVC(SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by engr in charge. |
| 53 | S&F 110mm PVC(SWR) bend any radius complete all as specified and directed by Engr in charge. |
| 54 | S&F 75mm PVC(SWR) bend any radius complete all as specified and directed by Engr in charge. |
| 55 | M&L 75mm PVC(SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed by engr in charge. |
| 56 | S & F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long all as specified and directed. |
| 57 | S&F in repair aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. |
| 58 | S & F for 600mm x 450mm bevelled edge mirror or selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chroimium plated brass screws and cup washers complete all as specified and directed. |
| 59 | Taking down carefully copper/aluminium point wiring from existing points (light, fan, socket or power) alongwith compete fittings such as switches ,ceiling rose, pendent holder, sketch fitting & regulator etc. including making good to the disturbed surfaces of wall, roof and floor etc. to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge. |
| 60 | M&L for point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through and including non metallic rigid PVC casing capping medium grade ISI Marked and all casing capping accessories fixed on wall/fixed to roof/truss/colums etc and including provision of 1.5 sqmm PVC insulated copper acble FRLSH as earth continuty conductor, febricated branded modular metal flush box duly make embossed, conncealed in walls with suitable modular inner and outer plate for housing modular switches, socket outlet and fan regulator etc. all as specified for one light point/ fan /Bell point controlled by one switch complete all as specified and directed by Engineer-in-Charge. |
| 61 | All as per Srl item No 60 here-in-before but controlled with one 5 pin socket outlet 5 Amp on same board with other switches with cables 1.5 Sqmm complete all as per specified and directed by Engineer-in-Charge. |
| 62 | All as per Srl item No 60 here-in-before but controlled with one 5 pin socket outlet 5 Amp, independent board with cable 1.5 sqmm including provision of 1.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 63 | All as per Srl item No 60 here-in-before but controlled with one 5 pin socket outlet 15 Amp, independent board with cable 2.5 sqmm including provision of 2.5 sqmm single core multistanded PCV insulated copper conductor as earth conducting conductor complete all as per specified and directed by Engineer-in-Charge. |
| 64 | Supply and fix in replacement of switch modular type 15 Amp, 230 Volt, single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 65 | Supply and fix in replacement of socket modular type outlet 5 pin 15 Amp 2-in-one 230 Volt complete all as specified and directed by Engineer -in-Charge. |
| 66 | Supply and fix in replacement of socket modular type outlet 5 pin 5 Amp 2-in-one 230 Volt complete all as specified and directed by Engineer -in-Charge. |
| 67 | Supply and fix in replacement of switch modular type type 5 Amp, 230 Volt, single pole one way complete all as specified and directed by Engineer -in-Charge, |
| 68 | Supply and fix in replacement of Ceiling rose, 3 terminal with ISI mark all as specified and directed by Engr-In-Charge. |
| 69 | Supply and fix in replacement of surface & wall mounted LED 20W tube light fitting 4 feet with high quality material and design, extruded aluminium housing enhances safety. High quality PC diffuser, reliable and robust housing structure, maximize the endurance over the life time slim integrated design, easy to install efficacy 125 limen/ watt all accessories as specified and directed by Engg-in-Charge. |
| 70 | Supply and fix in replacement of lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fittings. |
| 71 | Supply and fix in replacement of LED lamp 12W energy saving upto 80%, BEE rated with all accessories all as specified and directed by Engg-in-Charge. |
| 72 | Supply and fix in replacement of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 73 | Supply and fix in replacement of bulk head light with 10 W LED Lamp complete. |
| 74 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 AC decorativ type with driver jolder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 75 | Supply and fix in replacement of sheet metal enclosure double door for DBs single pole and neutral for 12 way 240 volt complete all as specified and directed by Engineer-in-Charge. |
| 76 | Supply and fix in replacement of MCB SPN 40Amp,10 KA all as specified and directed by Engineer-in-Charge |
| 77 | Supply and fix in replacement of MCB SP 6 to 32 Amp, 10 KA. all as specified and directed by Engineer-in-Charge. |
| 78 | Supplying and fixing 1100 volts grade heavy duty, XLPE aluminium cable, in service connections,twin core 10 Sqmm Circural cabel, complete all as per specified and directed by Engineer-in-Charge. |
| 79 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/jointing kit/repair of cable and erection of poles complete all as specified and directed |
| 80 | Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed. Note- (i)Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning. (ii) Surplus soil if any shall not be removed but left proud over the trench |
| 81 | M & L for sand filling floors or in foundation incl watering and compansation |
| 82 | M & L for old size bricks common burnt clay building bricks sub class B designation 75 |
| 83 | M&L for taking out old unserviceable and supply, laying, fixing Double walled corrugated HDPE duct pipe of 25 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed. |
| 84 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level with top edge of the plate not less than 1.5 mtr below the normal ground level connected to the galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers of galvanization of steel all as shown in electrical plate no 3 connected to earthing testing point all as specified or indicated including testing on completions. |
| 85 | Supply and fixing building LED street light fitting 35w 230 volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver lamp bracket with impact and corrosion resistant incl thermal management in multiple optics complete with IP 65/66 Protection complete, all as specified and directed |
| 86 | Supply & fix exhaust fan made of sturdy engineering plastic complete with louvers shuttter AC, Single Phase 230/240V 300mm sweep 1200 RPM, with louvre complete all as per specified and directed by Engineer-in-Charge Note: Fixing of Exhaust Fan on wall with suitable size anchor bolt , making hole in wall for groutng and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 87 | Supply and fix electric Water heater storage type tank and heating element upto 2 KW capacity 25 litres.BEE 5 star rated complete with all accessories such as safety valve, thermosate NRV connection pieces etc. Note: Fixing of geyser on wall with suitable size anchor bolt with hammer drill and making good the disturbed surface including plaster work shall be part of job at no extra cost. |
| 88 | S & F for fixing of GI Pipe bracket of 40mm dia size of 1.2 mtr long bent to shape for fixing of LED Street light fittings and fixing to pole, walls etc including fixing of clamp, nut bolt etc as specified and directed |
| 89 | Schedule of Credit Please Enable Macros to View BoQ information |