| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work:Repair/Maintenance of LT infrastructure and connected services at Tawi Water Supply installations under GE (Utilities) Udhampur Contract No: GE/U-61/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays, locating fault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Material and labour sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and directed by Engineer-in-Charge. |
| 4 | Supply and lay PCC cable cover class LV type 2 flat size 300 mm x 180 mm x 40 mm complete all as specified and directed by Engineer-in-Charge. |
| 5 | Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed by Engineer-in-Charge. |
| 6 | Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc, complete all as specified and directed by Engineer-in-Charge.Note: (i) Earth work, sand, bricks , removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost. |
| 8 | Description all as per item ser No 6.00 here- in- before, but for 3.5 core 35 Sqmm |
| 9 | Description all as per item ser No 6.00 here- in- before, but for 3.5 core 95 Sqmm |
| 10 | Description all as per item ser No 6.00 here- in- before, but for 3.5 core150 Sqmm |
| 11 | Description all as per item ser No 6.00 here- in- before, but for 3.5 core185 Sqmm |
| 12 | Description all as per item ser No 6.00 here- in- before, but for 3.5 core 240 Sqmm |
| 13 | Description all as per item ser No 6.00 here- in- before, but for 3.5 core 400 Sqmm |
| 14 | Description all as per item ser No 6.00 here- in- before, but for 3.5 core 630 Sqmm |
| 15 | Supplying and fixing in replacement of light grade galvanised mild steel pipe 150mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge.Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule. |
| 16 | Supplying and fixing in replacement of light grade galvanised mild steel pipe 100mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge.Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule. |
| 17 | Supplying and fixing in replacement of light grade galvanised mild steel pipe 50mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge.Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule. |
| 18 | Material and lobour in replacement of cross arms,bracings, supports, clamps and back plates fabricated from structural steel section incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape of size as indicated or directed and inclusive of one primercoat, one under coat and one finishing coat of paint incl dismantling and taking down old complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply and fixing in replacement MCCB 630 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply and fixing in replacement MCCB 400 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply and fixing in replacement MCCB 250 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 22 | Supply and fixing in replacement MCCB 200 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 23 | Supply and fixing in replacement MCCB 160 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 24 | Supply and fixing in replacement MCCB 100 Amps, 415 Volts, 16KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 25 | M&L for replecement Air Circuit Breaker 415V Microprocessor based SR18G release of capacity 1600A 4P 50K MDO rated current at 50°C conformance to IS/IEC 60947-2 & IEC 60947-2. ACB should have High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity and Having Electromechanical operation not less than 2000. ACB Should have overload phase protection, overload Neutral, short circuit, instantaneous, earth fault & individual fault LED indication complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for replecement Air Circuit Breaker 415V Microprocessor based SR18G release of capacity 1000A 4P 50K MDO rated current at 50°C conformance to IS/IEC 60947-2 & IEC 60947-2. ACB should have High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity and Having Electromechanical operation not less than 2000. ACB Should have overload phase protection, overload Neutral, short circuit, instantaneous, earth fault & individual fault LED indication complete all as specified and directed by Engineer-in-Charge. |
| 27 | M&L for replecement Air Circuit Breaker 415V Microprocessor based SR18G release of capacity 800A 4P 50K MDO rated current at 50°C conformance to IS/IEC 60947-2 & IEC 60947-2. ACB should have High short time withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity and Having Electromechanical operation not less than 2000. ACB Should have overload phase protection, overload Neutral, short circuit, instantaneous, earth fault & individual fault LED indication complete all as specified and directed by Engineer-in-Charge. |
| 28 | M&L for servicing/callibration /Repair to Air circuit breaker, 1600 Amp by OEM OF ACB only for EDO ( Electrically Draw out type/MDO type ( Mannually Draw out type).Taking out ACB for servicing/repair and checking/callibration of microprosser release ,Earth fault protection of 4 pole,50 KA breakingt capacity 415 volts with all draw out type mechanism,advanced self powered electronic protection units,neutral overload protection.automatic earth fault relay/over current relay,automatic safety shutter,inbuild temperature protection.icu=ics=icw(1s)=50 Ka fixed in panel complete including relay wiring checking,LT UG cable connection for its healthy functioning complete all as specified and directed by Engr-in-Charge. Note- Certificate of Servicing /callibration will be providded by the contractor free of cost |
| 29 | M&L for servicing/callibration /Repair to Air circuit breaker, 1000 Amp by OEM OF ACB only for EDO ( Electrically Draw out type/MDO type ( Mannually Draw out type).Taking out ACB for servicing/repair and checking/callibration of microprosser release ,Earth fault protection of 4 pole,50 KA breakingt capacity 415 volts with all draw out type mechanism,advanced self powered electronic protection units,neutral overload protection.automatic earth fault relay/over current relay,automatic safety shutter,inbuild temperature protection.icu=ics=icw(1s)=50 Ka fixed in panel complete including relay wiring checking,LT UG cable connection for its healthy functioning complete all as specified and directed by Engr-in-Charge. Note- Certificate of Servicing /callibration will be providded by the contractor free of cost. |
| 30 | M&L for servicing/callibration /Repair to Air circuit breaker, 800 Amp by OEM OF ACB only for EDO ( Electrically Draw out type/MDO type ( Mannually Draw out type).Taking out ACB for servicing/repair and checking/callibration of microprosser release ,Earth fault protection of 4 pole,50 KA breakingt capacity 415 volts with all draw out type mechanism,advanced self powered electronic protection units,neutral overload protection.automatic earth fault relay/over current relay,automatic safety shutter,inbuild temperature protection.icu=ics=icw(1s)=50 Ka fixed in panel complete including relay wiring checking,LT UG cable connection for its healthy functioning complete all as specified and directed by Engr-in-Charge. Note- Certificate of Servicing /callibration will be providded by the contractor free of cost. |
| 31 | S&F in replacement closing coil for air circuit breakers microprosser based type suitable for existing breakers as per site make/requirement including taking out breakers after taking shutdown of electric supply complete all as specified and as directed by Engr-in-Charge. |
| 32 | S&F in replacement spring charging motor for air circuit breakers microprocessor based type suitable for existing breakers as per site/requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F in replacement Shunt trip coil for air circuit breakers microprocessor based type suitable for existing breakers as per site/requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed by Engr-in-Charge. |
| 34 | S&F in replacement main contact set for air circuit breakers microprocessor based type suitable for existing breakers as per site/requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed by Engr-in-Charge. |
| 35 | S&F in replacement Arc chute set for air circuit breakers microprocessor based type suitable for existing breakers as per site/requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed by Engr-in-Charge. |
| 36 | S&F in replacement jaw contact set for air circuit breakers microprocessor based type suitable for existing breakers as per site/requirement including taking out breakers after taking shutdown of electric supply complete all as specified and directed by Engr-in-Charge. |
| 37 | Servicing and repair/maintenance of APFC 100 to 300 KVR Panel board & checking connections between load dives and sensing devices else where located in separate panel to check sequence of supply and set in proper condition including removal of defective device such as CT sencing cable and power cable,repair replacement of fuses,fuse link,control fuses,push button,LED indicator,auto manual selector switch,current transformer,and checking/replacing cable lugs,patch work welding,replacement of defective door hinges and testing of capacitor panel obtaining in board power factor to 0.95 to 0.98 of following capacities capacitor panel complete all as specified and directed by Engr-in-Charge.Note: Replacement of major items will be measured and paid seperatly. |
| 38 | S&F in replacement MCCB 100 Amps, 415 Volts, Ui-690V, Uimp-8kV, Ir-100 Amp, Im-800A IEC 60947-2 overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 39 | S&F in replacement MCCB 630 Amps, 415 Volts, Ui-690V, Uimp-8kV, Ir-630 Amp, Im-2000A IEC 60947-2 overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge. |
| 40 | S& F in replacement Capacitor cylindrical type suitable for 3 phase Un-440 volt 50hz,12.5 kvar, IS 13340 ,IEC 60531-2 complete all as specified and directed by Engr-in-Charge |
| 41 | S& F in replacement heavy duty plus capacitors suitable for 3 phase Un-440 volt 50hz,10 kvar, IS 13340 ,IEC 60531-2 complete all as specified and directed by Engr-in-Charge |
| 42 | S& F in replacement heavy duty plus capacitors suitable for 3 phase Un-440 volt 50hz,15 kvar, IS 13340 ,IEC 60531-2 complete all as specified and directed by Engr-in-Charge |
| 43 | S& F in replacement heavy duty plus capacitors suitable for 3 phase Un-440 volt 50hz,20 kvar, IS 13340 ,IEC 60531-2 complete all as specified and directed by Engr-in-Charge |
| 44 | S& F in replacement heavy duty plus capacitors suitable for 3 phase Un-440 volt 50hz,25 kvar, IS 13340 ,IEC 60531-2 complete all as specified and directed by Engr-in-Charge |
| 45 | S&F APFC relay of existing size and capacity upto 300kVAr suitable from 6 to 12 steps complete all as specified and directed by Engr-in-Charge. |
| 46 | S&F APFC multifuction meter of existing size and capacity upto 300kVAr suitable from 6 to 12 steps complete all as specified and directed by Engr-in-Charge. |
| 47 | S&F APFC Contector 3 pole with AC coil 415 V as per existing size and capacity suitable 10 Kvar complete all as specified and directed by Engr-in-Charge. |
| 48 | S&F APFC Contector 3 pole with AC coil 415 V as per existing size and capacity suitable 12.5 Kvar complete all as specified and directed by Engr-in-Charge. |
| 49 | S&F APFC Contector 3 pole with AC coil 415 V as per existing size and capacity suitable 15 Kvar complete all as specified and directed by Engr-in-Charge. |
| 50 | S&F APFC Contector 3 pole with AC coil 415 V as per existing size and capacity suitable 20 Kvar complete all as specified and directed by Engr-in-Charge. |
| 51 | S&F APFC Contector 3 pole with AC coil 415 V as per existing size and capacity suitable 25 Kvar complete all as specified and directed by Engr-in-Charge. |
| 52 | S&F MCB TPN 3 pole,25 to 63 Amp 10 KA, 'D' curve iniature circuit breakar complete connection testing and commisissiong complete all as specified and directed by Engr-in-Charge. |
| 53 | S&F MCB SP ,6 to 32 Amp 10 KA, 'D' curve iniature circuit breakar complete connection testing and commisissiong complete all as specified and directed by Engr-in-Charge. |
| 54 | M&L for replacement on/off load change over switch 250 Amps 4 pole 415 Volt AC 50 Hz conforming to IS:13947, open execution as per existing panel board size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 55 | M&L for replacement on/off load change over switch 630 Amps 4 pole 415 Volt AC 50 Hz conforming to IS:13947, open execution as per existing panel board size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 56 | M&L for replacement on/off load change over switch 800 Amps 4 pole 415 Volt AC 50 Hz conforming to IS:13947, open execution as per existing panel board size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 57 | M&L for replacement on/off load change over switch 1250Amps 4 pole 415 Volt AC 50 Hz conforming to IS:13947, open execution as per existing panel board size including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 58 | S&F in replacement copper tube (Thimbles) terminal heavy duty of size 185 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 59 | S&F in replacement copper tube (Thimbles) terminal heavy duty of size 150 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 60 | S&F in replacement copper tube (Thimbles) terminal heavy duty of size 120 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 61 | S&F in replacement copper tube (Thimbles) terminal heavy duty of size 95 Sqmm complete all as specified and directed by Engr-in-Charge. |
| 62 | M&L in replacement of aluminium lugs suitable for 630 Sqmm aluminium cable including taking down the existing unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 63 | M&L in replacement of aluminium lugs suitable for 400 Sqmm aluminium cable including taking down the existing unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 64 | M&L in replacement of aluminium lugs suitable for 240 Sqmm aluminium cable including taking down the existing unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 65 | M&L in replacement of aluminium lugs suitable for 150 Sqmm aluminium cable including taking down the existing unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 66 | M&L in replacement of aluminium lugs suitable for 95 Sqmm aluminium cable including taking down the existing unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 67 | Supply, fabricate, erect , connect, test and commissoning of factory made, CPRI approved, cubical type, indoor type LT panal board of size 1500x1200x500mm, totally enclosed , dust, weather and vermin proof 1100 Volt grade , 50Hz, AC supply made out by 3.15mm thick CRCA sheet steel for load bearing and 2 mm thick for non load bearing, fully compartmentalised, with IP 65 protection all as per conferming to IS 2417 of 1962 complete including the following accessories housed complete all as specified and directed by Engr-in-Charge. (a) ACB 800Amp 25 KA four pole 415 volt -01 (b) MCCB 630 Amp 25 KA four pole 415 volt -02 (c) Voltmeter and Ammeter-01 Set (d) Indicator (RYB) I set. (e) Bus bar 1200 Amp with CT&PT. |
| 68 | Servicing of crane capacity 3 Ton deems to be including the following process:- (a) Dismantling the main driving shaft of forward/reverse drive of cranes after unscrewing nuts, bolts, washers including other connected accessories with shaft such as breaking assembly, coupling, bearings, gear box lowering down the smaller portion of shaft from 20ft approximate height for removing and threading, repairing manufacturing drilling teeth keys, cleaning, greasing and oiling of all the bearing, bearing housing, gear box etc for smooth functioning, complete including re-assembly with connected accessories after repair including carrying out necessary alignment of all the parts connected with shaft all as specified and directed by Engr-in-Charge. |
| 69 | (b) Servicing / strip opening of up/down micro electric braking arrangement after un-screwing nuts, bolts washers, re-adjustment of braking springs, brake leathers, gun metal bushes of shaft housing in brake box making oiling/greasing arrangement complete re-assembling and testing complete all as specified and directed by Engineer -in-charge. (c) Servicing /strip opening of limit switches after unscrewing nuts/bolts washers for readjustment of limit switch, replacement of burnt contacts, wires, lugs/thimbles etc. Re-assembling and testing complete all as specified and directed by Engr-in- Charge. |
| 70 | S&F chain rope 12 mm of existing size 6X 19IWRC complete with fixing arrengment system including nut bolts and washers etc. for the smooth functioning of crane complete all as specified and directed by Engr-in-Charge. |
| 71 | Servicing of crane capacity 5 Ton, Servicing deems to be including the following process:- (a) Dismantling the manually operated main driving shaft of forward/reverse drive of cranes after unscrewing nuts, bolts, washers including other connected accessories with shaft such as breaking assembly, coupling, bearings, gear box lowering down the smaller portion of shaft from 20ft approximate height for removing and threading, repairing manufacturing drilling teeth keys, cleaning, greasing and oiling of all the bearing, bearing housing, gear box etc for smooth functioning, complete including re-assembly with connected accessories after repair including carrying out necessary alignment of all the parts connected with shaft all as specified and directed by Engineer-in-charge. |
| 72 | (b) Servicing / strip opening of up/down micro electric braking arrangement after un-screwing nuts, bolts washers, re-adjustment of braking springs, brake leathers, gun metal bushes of shaft housing in brake box making oiling/greasing arrangement complete re-assembling and testing complete all as specified and directed by Engineer -in-charge. (c) Servicing /strip opening of limit switches after unscrewing nuts/bolts washers for readjustment of limit switch, replacement of burnt contacts, wires, lugs/thimbles etc. Re-assembling and testing complete all as specified and directed by Engr-in Charge. |
| 73 | S&F chain rope 16 mm of existing size 6X37 galvanized 5 T rated complete with fixing arrengment system including nut bolts and washers etc. for the smooth functioning of crane complete all as specified and directed by Engr-in-Charge. |
| 74 | M&L for changing of Gear oil ISO VG-320 of EOT Crane of capacity 3/5 Ton after draining out old oil cleaning of Gear oil complete all as specified and directed by Engr-in-Charge. |
| 75 | S&F in repair lower block hook assembly fixed to EOT Crane & connecting complete all as specified and directed by Engr-in-Charge. |
| 76 | S&F single phase preventer for EOT Crane and connecting complete all as specified and directed by Engr-in-Charge. |
| 77 | S&F in repair limit switch to controll the movement of wheels of EOT Crane of capacity 3/5 Ton fixed in position and connecting complete all as specified and directed by Engr-in-Charge. |
| 78 | S&F in repair flame proof pendent of EOT Crane with capacity 3/5 Ton including(forward & Reverse,left & right,Start &stop,up and down,Emergency Stop) all connecting function complete all as specified and directed by Engr-in-Charge. |
| 79 | S&F contactor 16 Amp for EOT Crane and connecting complete all as specified and directed by Engr-in-Charge. |
| 80 | S&F in repair rope drum for chain rope of EOT Crane of capacity 3/5 Ton fixed in position and connecting complete all as specified and directed by Engr-in-Charge. |
| 81 | S&F in repair GI bus bar of 3 Nos with different colour mounting sleeve existing size and make on existing frame to controll the movement of EOT Crane of capacity 3/5 Ton fixed in position and connecting, complete all as specified and directed by Engr-in-Charge. |
| 82 | S&F in repair rail clips for fixing of bus bar existing size and make on existing frame to controll the movement of EOT Crane of capacity 3/5 Ton fixed in position and connecting, complete all as specified and directed by Engr-in-Charge. |
| 83 | Taking down motor from crane removing burnt-out winding from rotor and stator, cleaning of slots thoroughly, repairing and refilling of damaged slots wherever required with approved insulating/slot repair material, providing and inserting high quality Class ‘B’ insulation paper inside the slots, rewinding of electric motor of any capacity/make with super enamelled copper winding wire of same size and gauge as per existing, wrapping with high quality cotton tape, varnishing with superior quality insulating varnish, including baking/drying at required temperature and for required duration,and refixing motor, testing ans commisissiong complete all as specified and directed by Engr-in-Charge.Note: The quoted rate shall be deemed to include the cost of all labour, slot repairing/refilling material, insulation, winding, varnishing, baking/drying and routine testing. |
| 84 | Supply only spraying herbicide (Round up) on area to remove unwanted vegitation/grass at various locations complete all as specified and directed by Engr-in-Charge. |
| 85 | M&L Chemical spray (DC 2.26 contact cleaner) in container of 415 ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricants, displaces and seals out moisture release rusted mechanism etc complete all as specified and directed by Engr-in-Charge. |
| 86 | M&L in repair Indicator set R-Y-B complete all as specified and directed by Engr-in-Charge. |
| 87 | S&F combined voltmeter and Ammeter complete all as specified and directed by Engr-in-Charge. |
| 88 | S&F Vol seletor switch complete all as specified and directed by Engr-in-Charge. |
| 89 | S&F Electronic timer complete all as specified and directed by Engr-in-Charge. |
| 90 | S&F CT of different sizes upto 200 Amp complete all as specified and directed by Engr-in-Charge. |
| 91 | S&F Insulation tap multicolor (Blue, Red , Yellow , Green) 17 mm x 6 m, weather proof , moisture & fire resistant, excellent elascity, durable , good grip and strong adhesion complete all as specified and directed by Engr-in-Charge. |
| 92 | Material & Labour for in replacement of steel nuts, bolts, washers of any size required at site complete all as specified and directed by Engr-in-Charge. |
| 93 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25X4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :-(a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1.(c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. |
| 94 | (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal.(g) Testing of earthing.Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. |
| 95 | Supply, installation, testing, and commissioning of heavy-duty hot-dip galvanized wire mesh cable tray system, minimum 80-micron zinc coating, suitable for XLPE power cables of size 50 sq.mm to 400 sq.mm, including trays of minimum 105mm depth and 600mm width, 3 meter length each as per EN 12329 and IEC 61537 with wire mesh diameter of 3.9 to 5.9 mm having SST of 550 hrs tested having E30/E90 certificate and all necessary accessories like horizontal/vertical bends, tees, crosses, end caps, jointing couplers, and supporting hardware. Installation shall be on wall, ceiling, or structural frames using GI brackets, threaded rods, anchor bolts, beam clamps,console and other hardware as per site requirement. The system shall be aligned and secured for heavy-duty cable routing, with edges filed for smoothness to avoid cable damage and electrical specifications, complete all as specified and directed by Engr-in-Charge. |
| 96 | Disconnecting electrical connection carefully existing voltage stabilizer of 1000 kva capacity, draining out and refilling of existing transformer oil after filteration dehydration and measuring the dielectric strength which should not less than 50 KV including reinstallation of transformer satisfactory on its original position connecting testing and commissioning complete including all lighting arrangement with cable and other items for dehydration machine complete all as specified and directed by Engr-in-Charge. |
| 97 | Opening, maintenance and general servicing of 200 KVA Servo voltage stablizers of different makes drain out the transformer oil and taking out the core assembly out of the body. dehydrate and filtration of transformer oil (800 ltrs) for attaining the dielectric strength minimum 40KV. Cleaning the core of voltage stabilizer, Servicing and replacement the following unserviceable major parts and reassemble the core, refill the filtered and dehydrated transformer oil including connection making and testing on connected load to confirm the requisite satisfactory results complete all as specified and directed by Engr-in-Charge. Note:- Rate quoted by contractor is inclusive of following items:- (i) Wiring control panel incuding replacement of all indicators (ii) Servo motor with RC net work having torque of 10 kg/cm (iii) Microcontroller PCB card (iv) Checking and servicing of servo mechanism , gear synchronising system, automatic voltage regulator circuits and other allied electrical components complete. (iii) Unit rate is inclusive of replacement of all the minor parts ie. CT, PT, limit switch, temetarure sensor, HRC fusecarbon brushes gasket kit , indicator switch(iv) Service of Voltage stablizer done by company /authorized rep(v) Contractor shall make arrangement for required T&P.(Tro/Fro) |
| 98 | Opening, maintenance and general servicing of 1000 KVA Servo voltage stablizers of different makes drain out the transformer oil and taking out the core assembly out of the body. dehydrate and filtration of transformer oil (4200 ltrs) for attaining the dielectric strength minimum 40KV. Cleaning the core of voltage stabilizer, Servicing and replacement the following unserviceable major parts and reassemble the core, refill the filtered and dehydrated transformer oil including connection making and testing on connected load to confirm the requisite satisfactory results complete all as specified and directed by Engr-in-Charge.Note:- Rate quoted by contractor is inclusive of following items:- (i) Wiring control panel incuding replacement of all indicators (ii) Checking and servicing of servo mechanism , gear synchronising system, automatic voltage regulator circuits and other allied electrical components complete. (iii) Unit rate is inclusive of replacement of all the minor parts. (iv) Service of Voltage stablizer done by company /authorized rep(v) Contractor shall make arrangement for required T&P.(Tro/Fro) |
| 99 | S&F Servo motor sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 100 | S&F carbon brush set sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 101 | S&F microcontroller PCB meter sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 102 | S&F digital display meter sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 103 | S&F CT 400/5A sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 104 | S&F PT 415/110 Volt sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 105 | S&F limit swtch sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 106 | S&F control relay sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 107 | S&F temperture sensor sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 108 | S&F HRC fuse sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 109 | S&F Bypass switch sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 110 | S&F bushings sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 111 | S&F gasket set sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 112 | S&F cooling fan sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 113 | S&F contactor sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. |
| 114 | S&F dimmer sutable for 1000 KVA servo voltage stabilizer complete all as specified and directed by Engr-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail