| 1 | Distribution |
| 2 | Providing Strining out PVC pipes 6Kgf Cm2 ISI marked as per ISI-4985-2021 the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications for less than 3 mtr. Street width Complete in all respect. Specifications for Manually Excavation including speicals (6kgf/ cm2) Pressure |
| 3 | PVC pipe 63 mm o/d (6kgf/ cm2) Pressure |
| 4 | PVC pipe 75 mm o/d (6kgf/ cm2) Pressure |
| 5 | PVC pipe 90 mm o/d (6kgf/ cm2) Pressure |
| 6 | Providing Strining out PVC pipes 6Kgf Cm2 ISI marked as per ISI-4985-2021 the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications for More than 3 mtr street width (Mechanically Excavation and Including specials) (6kgf/ cm2) Pressure |
| 7 | PVC pipe 63 mm o/d (6kgf/ cm2) Pressure |
| 8 | PVC pipe 75 mm o/d (6kgf/ cm2) Pressure |
| 9 | PVC pipe 90 mm o/d (6kgf/ cm2) Pressure |
| 10 | PVC pipe 160 mm o/d (6kgf/ cm2) Pressure |
| 11 | Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position |
| 12 | 63 mm o/d |
| 13 | 75 mm o/d |
| 14 | Dismantling and Refixing of Interlocking Tile 80mm thick cement concrete Interlocking paver block and including restoration of roads to orginal Position. |
| 15 | 63 mm o/d PVC Pipe |
| 16 | 75 mm o/d PVC Pipe |
| 17 | Dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects |
| 18 | Dismantling of matalled road with Bithminous course 50 ti 75 mm thick with base course and making good the same to its original condition. |
| 19 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) Class PN-1 as per ISI |
| 20 | 80mm i/d Sluice Valves Flanged |
| 21 | 100 mm i/d Sluice Valves Flanged |
| 22 | Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department |
| 23 | 0.60 x 0.60 m |
| 24 | Development and Stabilizing of the tubewell with air compressor of requried capacity as directed by the Engineer-in Charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in Charge. |
| 25 | ( a) Capacity of Air Compressor 300 cfm at 250 PSI |
| 26 | HOUSE SERVICE CONNECTIONS |
| 27 | Providing proposed water connection to house hold up to wall with providing, laying jointing testing GI pipe lines 15mm i/d B-Class (Above GL), Providing & fixing MDPE pipe 15 mm i/d with specials 2.00 mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow, etc. cutting, threading and testing in trenches in the ground and ISI 15 mm i/d GM ferrule as per IS: 2692 and 3\\" i/d clamp with C.I bib cock, 15 mm i/d as per IS: 210 with stainless steel spindle of approved make |
| 28 | CHLORINATION & DISINFECTION |
| 29 | Prov. & Fixing Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications. |
| 30 | PUMPING MACHINERY, ELECTRIC CONNECTION D.I FITTING INSIDE PUMP CHAMBER |
| 31 | Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 369 LPM against a head of 63 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch, VM, AMpere Meter,ELCB, Shunt capacitor. Single phase,preventer,Indicating lamps,Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 80 mm & length 41 mtr (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 100 mtr length and 4.00mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects |
| 32 | Rate of Motor with Pump 369 lpm, head 63 mtr |
| 33 | Panel Board |
| 34 | Overall size 4.0sq.mm (84/0.3mm), 3Core (CSR 34.09 xiii (d)) |
| 35 | Column Pipe (G.I) 80 mm i/d (CSR 28.36 (h)) |
| 36 | Credit for old Panel Board |
| 37 | Credit for old Motor 10 BHP |
| 38 | DEVELOPMENT OF HEADWORKS |
| 39 | Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing |
| 40 | Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4\\" x 4\\", size top 3\\" x 4\\",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. |
| 41 | Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing Complete in all respect. |
| 42 | Construction of brick masonry corner pillar including cost of cement pointing including cost of material as perDWSS standard Drawing Complete in all respect. |
| 43 | Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing. Please Enable Macros to View BoQ information |