| 1 | 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell pointwith 1.5 sq.mm FRLS/HFFR PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS/HFFR PVCinsulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | DSR Item No. 1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 4 | 3 x 1.5 sq.mm |
| 5 | 3 x 2.5 sq.mm |
| 6 | 3 x 4 sq.mm |
| 7 | DSR Item no. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 8 | 25 mm |
| 9 | DSR Item no.1.50 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 10 | Upto 450 mm sweep |
| 11 | DSR Item No.2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required |
| 12 | 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 13 | 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 14 | Fabrication supply and erection of 16 Gauge MS sheet frame of suitable size to be fixed on existing MS window for installation of 15’ sweep exhaust fan. The job include the cost of cutting of iron Grill, welding, nut bolt of suitable size etc to accommodate the exhaust fan. The job includes the all-labour petty material to complete the job as per satisfaction of Engineer in- Charge at site. |
| 15 | DSR 8.15 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 16 | 100 WATT |
| 17 | Supply and erection of M.S. Box for Computer Point of size 200 x 250 x 75 mm deep in surface/recess as required and covered with 3mm thick white glazed Bakelite Sheet with provision for 4 Nos. 5/6 Amps switch and 4 Nos. 3 pin 5/6 Amps socket outlet (Piano type). The job includes the cost of making interconnections with suitable copper wires painting of box with approved paint and other petty material required to complete the job as per satisfaction of Engineer in- Charge at site. |
| 18 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole in existing wall suitable size of above fan making in original shape of wall. The size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. The Exhaust fan should be Havells/Orient and Bajaj make only. |
| 19 | Size 12 inches (300mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells make (Turbo Force SP)/ Crompton make ( EXHD300-6-1)/ Bajaj make (Supreme Plus)/ Orient make (Industrial Heavy Duty)/ Usha Make (Turbo HDEF) make only. |
| 20 | S/E of 1’x1’ LED fitting in Recess type with integral/ non integral driver to be installed in the existing false ceiling with suitable arrangement as required at site. The fitting should be Philips/ Wipro / Bajaj / Havells / Crompton / Jaquar / Surya / Panasonic/ Trilux/ LT make only. The job includes the cost of cutting of existing false ceiling of suitable size for erection of fitting with suitable arrangement etc. as required at site. The job includes the cost of testing, commissioning and making connection with 3x1.5 sq. mm. copper wire from adjacent light point, other petty material and labour etc. as required to complete the same to the entire satisfaction of Engineer In Charge. The LED fittings should be as per following design criteria AS PER COMPLETE ITEM NO.12 OF DNIT. |
| 21 | Supply and erection of 16 GMS sheet cubical duct. frame of size 1.5’x1.5’x1.5’ approx. to accommodate of 15” sweep exhaust fan. The duct should be provided with 16GMS sheet on the five side. The front side shall be cut from the centre of the sheet for exhaust fan to exhaust the air and opposite back fifth side shall be fixed with 1”x1”x 6 SWG square wire mesh provided with MS frame 1.5’x1.5’ square fabricated from 1.5” x 2 mm MS square frame to be fixed with MS duct by nut bolts etc. The duct should have prevision to accommodate the exhaust fan properly inside it with the prevision to fix the louver on front side. The duct should be fixed with 4 no. nut bolts on the existing MS window frame towards outside. The job includes all labour & material i.e. cost of material, carriage, fabrication, erection & welding etc. to complete the job to the entire satisfaction of EIC. Please Enable Macros to View BoQ information |