| 1 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 2 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 3 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and excluding necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. As in above item but for slabs (Using 1:1.5:3 Mix concrete) |
| 4 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and excluding necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20 but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. |
| 5 | All Work Up to Plinth Lvl. |
| 6 | Above Plinth Lvl. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 8 | Foundations, footings, bases of columns, etc. for mass concrete |
| 9 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. |
| 10 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 11 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 13 | Cement concrete with 20mm gauge approved stone grit, coarse sand & cement in the proportion of 1:2:4 including supply of all materials, labour, Tools & plants etc required for proper completion of the work. |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level or above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 15 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 16 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 17 | 12 mm cement plaster on fair side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) |
| 18 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 19 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 20 | Making cornice/moulding including labour, material etc. complete as per Design in direction of engineer in charge., Scaffolding works extra. |
| 21 | Providing & fixing of Precaste Chhatri including labour, material etc. complete as per Design in direction of engineer in charge. |
| 22 | Large Chhatri |
| 23 | Small Chhatri |
| 24 | Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCB's (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. SFP (OUTDOOR TYPE) IP 65 ,Incoming : One (1) No 40 Amp. 4P MCCB of 25KA Breaking capacity ,Metering : One (1) No. Sets Multifunction Meter each incoming,One (1) No. of Phase Indication Lamp each incoming, Bus Bar : One (1) No. 60 Amp.TPN aluminimum bus bar of suitable length., Outgoing : Phase indication lamps on each outgoing to be provided.,10 No. 16 Amp DP MCB. (10 KA) , 2 No. SPACE & SPARE,Panel described as above. |
| 25 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each |
| 26 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required |
| 27 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. |
| 28 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 29 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 30 | Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 31 | Laying of one number PVC insulated and PVC sheathed / XLPE power Cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm. |
| 32 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 33 | Supply of following siz of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment |
| 34 | 4 x 10 sq.mm |
| 35 | 3 x 6 sq.mm, |
| 36 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. |
| 37 | 2 X 6 sq. mm (19mm) |
| 38 | 4 X 10 sq. mm (19mm) |
| 39 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 |
| 40 | Supply, Installation, Testing and Commissioning of LED RGB/RGBW floodlighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9 . Fixture shall be suitable to operate at an ambient temperature range of - 10°C to +50°C and shall be IP 65 and IK 06 rated. Lifetime shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 45W /40W |
| 41 | Supply and Fixing of KL-3277 Linear In-Ground Luminare of 20W/Meter withour Driver of (1015X68X80)MM. Supply of linear 3000K/4000K/5700K In-Ground Grazer 24Vdc CRI >90 MacAdam step 3 Input power : 24W Dimension Ø1025 x 68 x 83mm Light Distribution should be Symmetrical Electronic driver ON/OFF (External driver) CE and BIS Approved. LUMINAIRE TYPE: Facade encapsulated 3000K/4000K/5700K In-Ground Graze with IP67. MATERIAL CHARACTERISTICS should be High grade aluminium housing (grade 6063 with test certificate) with End cap, SS fasteners & Clip, Mechanical resistance IK07. LIGHTING PERFORMANCE:: Polyurethane Encapsulation clear diffuser. This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, Surge protection 3KV. Including required accessories There may be changes in fixture selection and quantity as per architect intent Make Klite KL-3277,Unilamp/Ligman |
| 42 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 43 | Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 1 output per phase and suitable for single phase supply |
| 44 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 32 mm dia |
| 45 | Supply of retro refletive high intensity grade sheeting Type-IV orafol make sign board fixed over 8mm thick ACP sheet duly painted with grey enamel color on one side. The entire face of the ACP will be covered with Retro reflective Sheeting with back support MS angle frame 35*35*3 as per sec 800 of MORTH spec. complete in all respect as per direction of E/I. size 8.39m*2.035m including transportation charges. Please Enable Macros to View BoQ information |