| 1 | Taking down cement plaster up to 7.5 m height including raking out joints, hacking for key and scrubbing down with water etc to receive plaster complete all as specified and directed. |
| 2 | M&L for rendering 15mm in cement mortar (1:4) on fair faces of brick / concrete surfaces of walls and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 3 | M&L for rendering 10 mm in cement mortar (1:3) on fair faces of brick /concrete surface of ceiling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 4 | M&L for preparing newly plastered wall surfaces and applying two coats of weather proof exterior acrylic emulsion in camouflage pattern over and including one coat of primer of exterior grade complete all as specified and directed by Engineer-in-charge. |
| 5 | M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling of chajja and similar suspended work complete all as specified and directed. |
| 6 | M&L for preparation of old decorated painted surfaces of walls (plastered or unplastered) including all cornices pilasters etc by booming down or steel wire brushing, scraping down smoke, soot, moulds, moss and efflorescence salts, trading oil and greasy spots etc incl washing, rubbing down and stopping and applying one coat of weather proof exterior acrylic emulsion in camouflage pattern as approved upto any height complete all as specified and directed. |
| 7 | M&L for cement based wall care putty of 1mm thickness over plastered/Unplastered surface to prepare the surface even and smooth complete all as specified and directed.Note-Entire splashes in floor shall be cleaned immediately after completion of work |
| 8 | M&L for Writing letter / figure (Block, Roman, Italic or Indian) n exc 30 cm on existing surfaces (incl retouching / repainting with black paint underneath) complete all as specified and directed. |
| 9 | M&L for preparation of old painted steel and iron surfaces of corrugated and plain roof sheeting over 10 cm width or girth and applying one coat of synthetic enamel paint in camouflage pattern up to any height complete all as specified and directed.Note :- All necessary safety arrangements like rope, staging, safety harness etc shall be arranged by the contractor and nothing extra shall be admissible in to this account. The tenderer keep this factor in mind before quoting their rates. |
| 10 | M&L for preparation of old painted steel and iron surfaces n. exc 10 cm width or girth and applying one coat of synthetic enamel paint in complete all as specified and directed. |
| 11 | M&L for preparation of old painted steel and iron surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint in complete all as specified and directed. |
| 12 | M&L for preparation of old painted steel and iron surfaces of chain link fencing over 10 cm width or girth and applying one coat of aluminum paint in complete all as specified and directed. |
| 13 | M&L for complete removal of existing treatment on wall surface and applying two coats of weather proof exterior acrylic emulsion in camouflage pattern over and including one coat of primer of exterior grade complete all as specified and directed by Engineer-in-charge. |
| 14 | M&L for preparation of old painted surface of walls/ kerb stone / concrete of any description not otherwise described over 10 cm. width or girth shall include booming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of synthetic enamel painting complete all as specified and directed. |
| 15 | M & L for repair to RCC Chajjas, roof projection edges ,hanging part of chajjas, edges of chajjas, RCC parapets, under the roof / floor slabs with PCC 1:2:4 (using 12.5mm crushed graded agg) incl necessary reinforcement 8mm to 12mm TMT bars , form work , MS wire mesh for bounding the concrete on ground required and plaster work in CM 1:3 & periodical services to match with the existing surfaces finishing at any height of buildings etc complete all as specified and directed by Engineer-in-Charge. |
| 16 | S&F 3-4mm thick acrylic sheet board of High quality with best quality media printing incl 04 Nos of stainless steel stud for each board fixed to wall using drilling and making good (size of board , design of board , type of print on sheet, samples of letter, pictures, writing will be provided by accepting officer or Engineer-in-Charge) and fixed at any height from GL to 30 Mtr complete all as specified and directed incl dismantling of existing broken sheet. |
| 17 | Hacking out old broken glass (any thickness, size quality or description) from wooden frame or stone concrete or bricks surrounds glazed with putty or fixed with beads complete all as specified and directed. |
| 18 | S&F 3 mm thick sheet glass ordinary quality and glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete all as specified and directed. |
| 19 | S&F 3mm thick figured glass, pin head type and glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete all as specified and as directed M&L for disconnecting from the existing location cutting off worn out aluminium cable end and Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded,galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including taking out existing cable of any size. Please Enable Macros to View BoQ information |