| 1 | Job Contract for Operation and Maintenance of Electrical and Mechanical installations of 11 KV indoor substation consisting of HT panels, LT panels, Transformers, DG sets etc, Terminal Building, Technical Block, Other Ancillary Buildings, Ground Lighting Facilities (GLF), Water Supply Pumps, Perimeter lights, Flood light masts and AAI Residential colony on round the clock basis and for all days of the month including Sundays and holidays in Two/Three shifts, which involves repairs & maintenance, attending day to day complaints, faults, breakdowns and taking rectification action, ensuring the serviceability & satisfactory working condition of the installations i/c preventive maintenance, maintenance of records & documentations etc., The agency is required to deploy minimum manpower in each shift as detailed in special condition of contract and as per the instruction of Engineer-in-charge complete as required. | Job Contract for Operation and Maintenance of Electrical and Mechanical installations of 11 KV indoor substation consisting of HT panels, LT panels, Transformers, DG sets etc, Terminal Building, Technical Block, Other Ancillary Buildings, Ground Lighting Facilities (GLF), Water Supply Pumps, Perimeter lights, Flood light masts and AAI Residential colony on round the clock basis and for all days of the month including Sundays and holidays in Two/Three shifts, which involves repairs & maintenance, attending day to day complaints, faults, breakdowns and taking rectification action, ensuring the serviceability & satisfactory working condition of the installations i/c preventive maintenance, maintenance of records & documentations etc., The agency is required to deploy minimum manpower in each shift as detailed in special condition of contract and as per the instruction of Engineer-in-charge complete as required. |
| 2 | Execution of items of schedule of rates E&M CPWD DSR-2022 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations at different locations of Mysuru Airport (City Side and Nav-Aids buildings) and residential colony as per direction of E-I-C. The bidder shall quote percentage (%) above / below the DSR 2022 rates in the form of multiplication factor. i.e. (for eg :- If the bidder desries to quote 5% above on DSR 2022 rates, the rate column shall be filled as 1.05 and 5% below, the rate column shall be filled as 0.95). (Note: Since the rate of DSR-2022 is incusive of GST, Payment will be made after deducting GST component from DSR-2022 rates). | Execution of items of schedule of rates E&M CPWD DSR-2022 as and when required for attending breakdowns, repair & maintenance and upkeep of internal and external electrical installations at different locations of Mysuru Airport (City Side and Nav-Aids buildings) and residential colony as per direction of E-I-C. The bidder shall quote percentage (%) above / below the DSR 2022 rates in the form of multiplication factor. i.e. (for eg :- If the bidder desries to quote 5% above on DSR 2022 rates, the rate column shall be filled as 1.05 and 5% below, the rate column shall be filled as 0.95). (Note: Since the rate of DSR-2022 is incusive of GST, Payment will be made after deducting GST component from DSR-2022 rates). |
| 3 | SH III : PAINTING, OVERHAULING & REWINDING WORKS | SH III : PAINTING, OVERHAULING & REWINDING WORKS |
| 4 | Painting of electrical HT/LT panels (Indoor/Outdoor types), Water supply pumpsets , earth pit covers etc installed at various locations of Airport/Residential Colony with one or more coats of spray painting with synthatic Enamel paint of Approved brand and manufacturer to give an even shade, including cleaning of surface etc , of required color as per the instruction of Engineer-in-charge complete as required. | Painting of electrical HT/LT panels (Indoor/Outdoor types), Water supply pumpsets , earth pit covers etc installed at various locations of Airport/Residential Colony with one or more coats of spray painting with synthatic Enamel paint of Approved brand and manufacturer to give an even shade, including cleaning of surface etc , of required color as per the instruction of Engineer-in-charge complete as required. |
| 5 | Rewinding of 5HP submersible borewell pump motor with copper conductor of suitable size i/c dismantling and transportation to work shop and back, re- installation i/c any related repair, servicing, testing, & commissioning. (Note : Dismantled material / wire shall be property of tenderer) | Rewinding of 5HP submersible borewell pump motor with copper conductor of suitable size i/c dismantling and transportation to work shop and back, re- installation i/c any related repair, servicing, testing, & commissioning. (Note : Dismantled material / wire shall be property of tenderer) |
| 6 | Servicing & overhauling of submersible borewell of 5HP capacity i/c replacement of wornout bushes, bearings, impellers and other internal parts etc complete as required.. (Note : Dismantled material shall be property of tenderer) | Servicing & overhauling of submersible borewell of 5HP capacity i/c replacement of wornout bushes, bearings, impellers and other internal parts etc complete as required.. (Note : Dismantled material shall be property of tenderer) |
| 7 | Rewinding of 7.5HP submersible openwell type pump motor with copper conductor of suitable size i/c dismantling and transportation to work shop and back, re- installation i/c any related repair, servicing, testing, & commissioning. (Note : Dismantled material / wire shall be property of tenderer) | Rewinding of 7.5HP submersible openwell type pump motor with copper conductor of suitable size i/c dismantling and transportation to work shop and back, re- installation i/c any related repair, servicing, testing, & commissioning. (Note : Dismantled material / wire shall be property of tenderer) |
| 8 | Servicing & overhauling of submersible pump of 7.5HP replacement of wornout bushes, bearings, impellers, and other internal parts etc complete as required. (Note : Dismantled material / wire shall be property of tenderer) | Servicing & overhauling of submersible pump of 7.5HP replacement of wornout bushes, bearings, impellers, and other internal parts etc complete as required. (Note : Dismantled material / wire shall be property of tenderer) |
| 9 | Lifting and lowering of submersible pumpset of 5 HP from the depth upto 200 feet including dismantling of the column pipe, cable etc and re-installation of pump and motor set in the bore well along with all necessary work like providing and fixing of required gasket & nut bolts, and welding & threading of GI Pipe and Flanges etc as required and making connection to the discharge line after dry revolution test complete as required. | Lifting and lowering of submersible pumpset of 5 HP from the depth upto 200 feet including dismantling of the column pipe, cable etc and re-installation of pump and motor set in the bore well along with all necessary work like providing and fixing of required gasket & nut bolts, and welding & threading of GI Pipe and Flanges etc as required and making connection to the discharge line after dry revolution test complete as required. |
| 10 | Testing/Calibration of following Protection Relays of HT/LT Panel by secondary injection method with testing kit duly calibrated from Govt approved laboratory/test centre including submission of report of calibration to AAI. | Testing/Calibration of following Protection Relays of HT/LT Panel by secondary injection method with testing kit duly calibrated from Govt approved laboratory/test centre including submission of report of calibration to AAI. |
| 11 | Over Current & Earth Fault Relay MCI6A Dual rated relay (Make - L&T 51/50 RYBN - O/C and E/F Relay) | Over Current & Earth Fault Relay MCI6A Dual rated relay (Make - L&T 51/50 RYBN - O/C and E/F Relay) |
| 12 | Under Voltage Relay (Make - EASUN REYROLLE, MDDA - code - 07467, Rating Voltage-24V DC/110V AC) | Under Voltage Relay (Make - EASUN REYROLLE, MDDA - code - 07467, Rating Voltage-24V DC/110V AC) |
| 13 | AUX Relay for Under voltage (Make - EASUN REYROLLE, B33X3 - code - 08083, Rating voltage - 24V DC) | AUX Relay for Under voltage (Make - EASUN REYROLLE, B33X3 - code - 08083, Rating voltage - 24V DC) |
| 14 | Timer Relay for Display start (Make - EASUN REYROLLE, MDDA/B12 - code - 03206, Rating voltage - 24V DC) | Timer Relay for Display start (Make - EASUN REYROLLE, MDDA/B12 - code - 03206, Rating voltage - 24V DC) |
| 15 | AUX Relay : 49X1 49X2 49X3 (Make - EASUN REXROLLE, B33X3, Code - 03677, Rating voltage - 24V DC) | AUX Relay : 49X1 49X2 49X3 (Make - EASUN REXROLLE, B33X3, Code - 03677, Rating voltage - 24V DC) |
| 16 | AUX Relay : 63X1 63X2 63X3 (Make - EASUN REXROLLE, Rating Voltage - 24V DC) | AUX Relay : 63X1 63X2 63X3 (Make - EASUN REXROLLE, Rating Voltage - 24V DC) |
| 17 | Reverse power relay (Make :L&T , Model no.MRP11) | Reverse power relay (Make :L&T , Model no.MRP11) |
| 18 | Tripping Relay (Make :L&T, Model No. LL1410) | Tripping Relay (Make :L&T, Model No. LL1410) |
| 19 | SH V:- FILTRATION OF TRANSFORMER OIL AND ASSOCIATED WORKS | SH V:- FILTRATION OF TRANSFORMER OIL AND ASSOCIATED WORKS |
| 20 | Filtration and determination of electric strength of transformer insulation oil of 11KV/415V transformer with not less than two circulation of oil and testing of oil after filtration so as to achieve a break down value of not less than 60 KV for a minute as per IS:1866/IS:6792-1972 with upto date amendments, including , hiring and transporting charges for filtration equipment, test kit etc. as required. | Filtration and determination of electric strength of transformer insulation oil of 11KV/415V transformer with not less than two circulation of oil and testing of oil after filtration so as to achieve a break down value of not less than 60 KV for a minute as per IS:1866/IS:6792-1972 with upto date amendments, including , hiring and transporting charges for filtration equipment, test kit etc. as required. |
| 21 | Supply of Transformer Oil conforming to IS:335 to be supplied in non-returnable barrel | Supply of Transformer Oil conforming to IS:335 to be supplied in non-returnable barrel |
| 22 | SH VI:- SERVICING OF HT PANELS AND LT ACB'S OF POWER SUPPLY INSTALLATIONS | SH VI:- SERVICING OF HT PANELS AND LT ACB'S OF POWER SUPPLY INSTALLATIONS |
| 23 | Servicing of 800Amps, 11KV, 18.4 kA VCB of Kirloskar make (Type- CM 500, Operating Coil Voltage - 24V, DC) through OEM / Authorized dealer including checking and measurement of IR values of breakers and busbars, contact resistance of breakers , cleaning of CTs, PTs, Busbar, applying lubricants, adjustments etc as per the manufacturers recommendations and submission of calibration/service reports etc., as required (Excluding spare parts) | Servicing of 800Amps, 11KV, 18.4 kA VCB of Kirloskar make (Type- CM 500, Operating Coil Voltage - 24V, DC) through OEM / Authorized dealer including checking and measurement of IR values of breakers and busbars, contact resistance of breakers , cleaning of CTs, PTs, Busbar, applying lubricants, adjustments etc as per the manufacturers recommendations and submission of calibration/service reports etc., as required (Excluding spare parts) |
| 24 | Servicing and Overhauling of ACBs (Make : Siemens/ABB of various capacities) by deploying Authorised Service Personnel of Manufacturer/Service Dealer/Specialised Agencies including cleaning of ACBs, opening the same, inspection, servicing, cleaning of contact surfaces, arc chutes, overhauling of operating mechanism, lubrication of moving parts, checking of UV coils, Trip circuits, checking of control circuits, checking of tripping/control/indication circuits, testing of protection releases by primary/secondary injection, consumables for servicing, replacement of wornout/defective components and spares as and when required, testing and commissioning as per respective OEM recommendations including submission of reports. etc as required. (Excluding spare parts) | Servicing and Overhauling of ACBs (Make : Siemens/ABB of various capacities) by deploying Authorised Service Personnel of Manufacturer/Service Dealer/Specialised Agencies including cleaning of ACBs, opening the same, inspection, servicing, cleaning of contact surfaces, arc chutes, overhauling of operating mechanism, lubrication of moving parts, checking of UV coils, Trip circuits, checking of control circuits, checking of tripping/control/indication circuits, testing of protection releases by primary/secondary injection, consumables for servicing, replacement of wornout/defective components and spares as and when required, testing and commissioning as per respective OEM recommendations including submission of reports. etc as required. (Excluding spare parts) |
| 25 | SH VII:- MISCELLANEOUS WORKS | SH VII:- MISCELLANEOUS WORKS |
| 26 | Hire charges for providing coloured LED serial lighting sets (Minimum 500 nos and each consisting of minimum 50 nos of LED lamps), 50 Nos of MH lights, 50 Nos of RGB LED PAR light etc for decorating Terminal building, Technical building, City side areas etc during events or occasssions like Independence day / Republic Day /other festive occassions as per the direction of AAI including all other related accessories like circuit / sub main wiring along with earth wire from nearest supply point as required and maintaining the same by deploying suitable manpower, tools, tackles, ladders etc on round the clock etc complete as per actual site requirements, removing and taking back the same after completion of occassion period.(One event consists of 3days,which will treated as 1 Job | Hire charges for providing coloured LED serial lighting sets (Minimum 500 nos and each consisting of minimum 50 nos of LED lamps), 50 Nos of MH lights, 50 Nos of RGB LED PAR light etc for decorating Terminal building, Technical building, City side areas etc during events or occasssions like Independence day / Republic Day /other festive occassions as per the direction of AAI including all other related accessories like circuit / sub main wiring along with earth wire from nearest supply point as required and maintaining the same by deploying suitable manpower, tools, tackles, ladders etc on round the clock etc complete as per actual site requirements, removing and taking back the same after completion of occassion period.(One event consists of 3days,which will treated as 1 Job |
| 27 | Calibration charges for Lux Meter from any NABL/Govt approved testing centre for energy management and test systems for electrical apparatus. | Calibration charges for Lux Meter from any NABL/Govt approved testing centre for energy management and test systems for electrical apparatus. |
| 28 | Charges for calibration of Clino meter from OEM i.e, M/s AMA pvt Ltd ,Mumbai including transportation charges. | Charges for calibration of Clino meter from OEM i.e, M/s AMA pvt Ltd ,Mumbai including transportation charges. |
| 29 | Calibration charges for clamp meter from NABL/Govt approved testing centre for energy management and test systems for electrical apparatus. | Calibration charges for clamp meter from NABL/Govt approved testing centre for energy management and test systems for electrical apparatus. |
| 30 | Supply and fixing 2.5 mm (nominal ± 10%) thick and 1 mtr wide synthetic insulation mat suitable for upto 11 KV grade as per IS: 15652:2006 with upto date amendments along with suitable adhesive / sealing material i/c sealing of all joints and corners etc. as required. | Supply and fixing 2.5 mm (nominal ± 10%) thick and 1 mtr wide synthetic insulation mat suitable for upto 11 KV grade as per IS: 15652:2006 with upto date amendments along with suitable adhesive / sealing material i/c sealing of all joints and corners etc. as required. |
| 31 | Providing of scaffolding made of metal pipes of suitable size upto a height of 12 metres with structure & platform with bar for working personnel, stabilizing legs at base for stabilising the scaffolding and provision for levelling according to floor height. The scope involves providing (Including transportation to & from airport, loading, unloading of scaffolding at site – airport), assembling the scaffolding at locations as directed by Engineer in charge, dismantling the same after work etc., as required, complete with all accessories required. | Providing of scaffolding made of metal pipes of suitable size upto a height of 12 metres with structure & platform with bar for working personnel, stabilizing legs at base for stabilising the scaffolding and provision for levelling according to floor height. The scope involves providing (Including transportation to & from airport, loading, unloading of scaffolding at site – airport), assembling the scaffolding at locations as directed by Engineer in charge, dismantling the same after work etc., as required, complete with all accessories required. |
| 32 | Carrying out maintenance of RO plant (Make: Eureka forbs, 250 LPH through OEM/Authorized dealer including supply of the below mentioned consumables as on requirement and submitting the satisfactory reports complete as per manufacturers recommendation | Carrying out maintenance of RO plant (Make: Eureka forbs, 250 LPH through OEM/Authorized dealer including supply of the below mentioned consumables as on requirement and submitting the satisfactory reports complete as per manufacturers recommendation |
| 33 | 1st year | 1st year |
| 34 | 2nd Year | 2nd Year |
| 35 | Supply of following consumables for RO plant as per OEM recommendations. | Supply of following consumables for RO plant as per OEM recommendations. |