| 1 | Supply and fix window type air conditioner electric driven single phase cooling capacity 4500 K Cal per hour 1.5 TON BEE 3 star | Supply and fix window type air conditioner electric driven single phase cooling capacity 4500 K Cal per hour 1.5 TON BEE 3 star |
| 2 | Material and labour for sub-main wiring surface type with two run of PVC insulated, unsheathed, FRLS single core and one run of 4.0 Sqmm copper conductor | Material and labour for sub-main wiring surface type with two run of PVC insulated, unsheathed, FRLS single core and one run of 4.0 Sqmm copper conductor |
| 3 | Supply and fix Single pole and neutral enclosure 240 volt, 20 Amps with a two pin and earth plug and socket complete with one single pole MCB | Supply and fix Single pole and neutral enclosure 240 volt, 20 Amps with a two pin and earth plug and socket complete with one single pole MCB |
| 4 | supply and fix automatic voltage stablizer single phase 220 volt 50 hz of capacity 5 KVA all as specified and as directed | supply and fix automatic voltage stablizer single phase 220 volt 50 hz of capacity 5 KVA all as specified and as directed |
| 5 | M and L cutting chases, pinning in making good to facing where required and pointing in cement mortar 1-3 to ends or edges of landings, steps, cils, sunshades sheleves, lintels, etc | M and L cutting chases, pinning in making good to facing where required and pointing in cement mortar 1-3 to ends or edges of landings, steps, cils, sunshades sheleves, lintels, etc |
| 6 | Material and labour for sub-main wiring surface type with two run of PVC insulated.unsheathed, FRLS single core and one run of 6.0 Sqmm copper conductor | Material and labour for sub-main wiring surface type with two run of PVC insulated.unsheathed, FRLS single core and one run of 6.0 Sqmm copper conductor |
| 7 | M and L for stand bracket fabricated from structural steel section suitable for 3 Ton AC outdoor unit including nut, bolt, washer, welding. Bedding cold or hot | M and L for stand bracket fabricated from structural steel section suitable for 3 Ton AC outdoor unit including nut, bolt, washer, welding. Bedding cold or hot |
| 8 | Supply and fix Single pole and neutral enclosure 240 volt, 40 Amps with a two pin and earth plug and socket complete with one single pole MCB | Supply and fix Single pole and neutral enclosure 240 volt, 40 Amps with a two pin and earth plug and socket complete with one single pole MCB |
| 9 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and 90 V to 300 V with output voltage stabilized at 230 V | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and 90 V to 300 V with output voltage stabilized at 230 V |
| 10 | Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and d 170-270 volt with output voltage stabilizer at 230 volt | Supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and d 170-270 volt with output voltage stabilizer at 230 volt |
| 11 | S and F Motor starter 25 amp with on off Push type switch, modular type two module Make Make Legrand-GM-Havells | S and F Motor starter 25 amp with on off Push type switch, modular type two module Make Make Legrand-GM-Havells |
| 12 | S and F Socket 25 amp modular type two module Make Legrand-GM-Havells | S and F Socket 25 amp modular type two module Make Legrand-GM-Havells |
| 13 | S and F Metal flush box, modular type Four module Make Legrand-GM-Havells | S and F Metal flush box, modular type Four module Make Legrand-GM-Havells |
| 14 | S and F Cover plate with metal frames, modular type four module Make Legrand-GM-avells | S and F Cover plate with metal frames, modular type four module Make Legrand-GM-avells |
| 15 | M and L for stand-bracket fabricated from structural steel section suitable for 1.5 Ton-2 Ton AC outdoor unit including nut, bolt, washer, welding. Bedding cold or hof, drilling holes for bolts | M and L for stand-bracket fabricated from structural steel section suitable for 1.5 Ton-2 Ton AC outdoor unit including nut, bolt, washer, welding. Bedding cold or hof, drilling holes for bolts |
| 16 | Supply and fix power socket 240 volt AC 25 A 2 module all as specified and directed | Supply and fix power socket 240 volt AC 25 A 2 module all as specified and directed |
| 17 | Supply and fix 25 A motor starter 2 module all as specified and directed | Supply and fix 25 A motor starter 2 module all as specified and directed |
| 18 | Supply and fix modular white cover plate metallic frame 2 module all as specified and directed | Supply and fix modular white cover plate metallic frame 2 module all as specified and directed |
| 19 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 90 V to 300 V 230 V | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 90 V to 300 V 230 V |