| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 5 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 6 | 1:4:8 (1 Cement : 4 pulverised sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, if nishing and reinforcement- All work up to plinth level : |
| 9 | 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement |
| 11 | 1:1.5:3 (1 cement : 1.5 pulverised sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 pulverised sand (zone-III)derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 14 | Foundations, footings, bases of columns, etc. for mass concrete |
| 15 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 18 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 19 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 20 | G.I. pipes |
| 21 | Cement concrete flooring 1:2:4 (1 cement : 2 pulverised sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 22 | 40 mm thick with 20 mm nominal size stone aggregate |
| 23 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 24 | Providing and laying Hollow cement concrete block walling 200mm thick consisting of hollow block of size 400x200x200mm of mix 1:3:6 (1cement:3 Pulverised sand:6 graded stone aggregates of 10mm nominal size) laid in cement martar 1:6(1cement :6 sand). |
| 25 | 12 mm cement plaster of mix : |
| 26 | 1:4 (1 cement: 4 River sand) |
| 27 | Extra for providing and fixing wind ties of 40x 6 mm flat iron section. |
| 28 | Finishing walls with water proofing cement paint of required shade : |
| 29 | New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 30 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 Pulverised sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick stone aggregate 40mm nominal size well rammed and consolidated and grouted with Pulverised sand including finishing the top smooth. |
| 31 | Providing and fixing in position eave or facia board with 12 mm thick non asbestos plain sheet of HILUX Board and 30 cm wide including nailing etc. Complete as per the direction of Engineer-in-charge. |
| 32 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 33 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 34 | Applying priming coat: |
| 35 | With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 37 | Two or more coats on new work |
| 38 | Providing cement concrete surface drain i/c. earth work excavation, 10 cm thick baseconcrete and 15cm thick side walling with 1:3:6 (1 cement: 3 Pulverized sand: 6 grade stone aggregate 40mm nominal size) finishing with 12mm thick cement plaster. 23x23cm surface drain. |
| 39 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : |
| 40 | Two or more coats on new work |
| 41 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 42 | All kinds of soil. |
| 43 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. Please Enable Macros to View BoQ information |