| 1 | Taking down ceiling fan / exhaust fan / wall mounted fans of any type and size and transportation to workshop and examining the rotor, stator, bearings/ bushes, winding etc. subsequently oiling, greasing, assembling, testing and transporting back to existing site from workshop and hanging/ re-fixing the same and connecting the electrical connections, testing for noise free smooth running etc, complete all as specified and directed.Note :- Work for repair/ replacement of spare parts will be measured and paid separately under respective items of this BOQ. |
| 2 | Taking out defective/ burnt out windings of ceiling fans of various makes from site under GE (North) AOR, size 1200/1400mm sweep 220-240 Volts 50Hz and rewinding the same with supper enamelled new copper wire of appropriate gauge including varnishing with good quality varnish, baking up, re-assembling the fan including testing, complete all as specified and directed. |
| 3 | All as per serial item No. 2.00 here-in-above but for exhaust fans / wall fans of size 150mm to 450mm sweep. |
| 4 | S&F in replacement of defective bush of any size and type for exhaust fans, wall fans, pedestral fans, complete all as specified and directed. |
| 5 | S&F in replacement of defective ball bearing for ceiling of any size and any type, complete all as specified and directed. |
| 6 | S&F in replacement of defective capacitor of capacity 2.5 mfd, suitable for any type of fans, 240 volts including making connection, complete all as specified and directed. |
| 7 | All as per serial item No. 6.00 here-in-above but capacity 3.15 mfd. |
| 8 | All as per serial item No. 6.00 here-in-above but capacity 0.75/1.5 mfd, suitable for PVC/ steel exhaust fans of any type and any size. |
| 9 | S&F in repair of PVC insulated twin twisted copper conductor wire, 220-240 Volt grade, complete all as specified and directed. |
| 10 | M&L for cleaning of ceiling fan and painting of ceiling fan along with blades of any make & model of size 1200mm to 1400mm sweep, complete all as specified and directed. |
| 11 | All as per serial item No. 10.00 here-in-above but for exhaust fan of size 300mm - 450mm sweep, complete all as specified and directed. |
| 12 | S&F in replacement of PVC canopy, suitable for 1200mm to 1400mm sweep ceiling fan, complete all as specified and directed. |
| 13 | S&F 'S' type hook, made of 12mm dia MS round bar/ MS flat iron strip of size 40x4mm, complete all as specified and directed. |
| 14 | S&F air circulator toilet/ bathroom fan, PVC body AC single phase 230 Volts of size 150mm sweep with blades, frame and louver, complete all as specified and directed. |
| 15 | S&F air circulator toilet/ bathroom fan, PVC body AC single phase 230 Volts of size 200-250mm sweep with blades, frame and louver, complete all as specified and directed. |
| 16 | S&F exhaust fan heavy duty steel body, industrial type wall mounted, AC single phase 230 volts of size 450mm sweep with 4 blades, four arms, frame and louver, complete all as specified and directed. |
| 17 | S&F wall mounted fan, steel body, AC single phase 230 volts of size 400mm sweep with blades, complete all as specified and directed. |
| 18 | S&F in replacement of defective BLDC ceiling fan control PCB board, AC single phase 230 Volts (as per site requirement), suitable for Bajaj/ Halonix/ Havells/ Orient/ Anchor BLDC ceiling fans of size 1200/1400mm sweep, complete all as specified and directed. |
| 19 | S&F BLDC ceiling fan of 1200mm sweep, AC single phase 230 Volts, BEE 5 star rated, copper winding with complete accessories as per manufacturer, complete all as specified and directed. |
| 20 | S&F BLDC ceiling fan of 1400mm sweep, AC single phase 230 Volts, BEE 5 star rated, copper winding with complete accessories as per manufacturer, complete all as specified and directed. |
| 21 | S&F clamp for down rod of suitable size including gromet/ reel type rubber pad with bolts, nuts and washers and split pin, suitable for housing ceiling fans, complete all as specified and directed. |
| 22 | S&F louver shutter made of GI sheet metal / pressed steel sheet for round base and 0.80mm thick for flaps, comprising of mounting legs, frames, exhust fan of size upto 300/450mm sweep etc. complete all as specified and directed. |
| 23 | S&F in replacement of ceiling fan blade set, suitable for 1200/1400mm sweep ceiling fans of any make and model, aero dyanamically balanced including screws for fixing with fan, complete all as specified and directed. |
| 24 | S&F in replacement of MS down rod, heavy duty, 15mm nominal dia 18\\" long duly painted to match with colour of ceiling fan, complete all as specified and directed. |
| 25 | S&F in replacement of rigid aluminium fan blade for exhaust of capacity 300/450mm sweep, complete all as specified and directed. |
| 26 | Disconnection of electric and water connection and taking down carefully storage type electric water heaters (Geysers) of capacity 25/35/50 Ltrs of any make & model from its existing position and inspection of geysers for it's serviceability / un-serviceability, complete all as specified and directed. |
| 27 | S&F in replacement of geyser heating element of any type, suitable for electric geysers available at site i.e (Make : Clenta, Bajaj, Recold, Crompton, Havells etc.) of capacity 2 KW as required, complete all as specified and directed. |
| 28 | S&F electric water heater storage type steel body with copper inner tank and heating element upto 2 KW of capacity 25 litres, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes etc, complete all as specified and directed. |
| 29 | S&F electric instant water heater, ABS outer with SS inner tank and heating element upto 3 KW of capacity 3 litres, suitable 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes etc, complete all as specified and directed. |
| 30 | S&F in replacement of thermostat, suitable for all type of electric geyser as available at site (Make : Clenta, Bajaj, Recold, Crompton, Havells), 240 Volts AC, temperature adjustable, suitable for 25 to 50 Ltrs capacity electric water heaters and making electrical connections, complete all as specified and directed. |
| 31 | S&F Neon lamp (Red & Green) round / square in shape, suitable for 25/35/50 liters capacity geysers including making electrical connection at it's original position including taking down old lights, complete all as specified and directed. |
| 32 | S&F in replacement of base cover plate steel for mounting of indicator lamp in existing shape and size, suitable for 25 to 50 ltrs capacity of electric water geysers, complete all as specified and directed. |
| 33 | S&F in replacement of stainless steel braided flexible 'Hot' & 'Cold' water connection hoses pipes tubes, suitable for working temp of not less than 90 degree centigrage of side, size 450/600mm long of suitable dia, complete all as specified and directed. |
| 34 | S&F in replacement of inner shell (inner tank), made out of stainless steel sheet 20 guage, suitable for 25 Ltrs capacity electric water heater in existing shape and size, complete all as specified and directed. |
| 35 | All as per serial item No. 34.00 here-in-above but 50 Ltrs capacity electric water heater. |
| 36 | S&F in replacement of outer body cover complete with top and bottom cover, inspection plate of 25 Ltrs capacity electric water heater duly painted with super enamelled paint with two coats over a coat of red oxide zinc chrome steel primer, complete all as specified and directed. |
| 37 | All as per serial item No. 36.00 here-in-above but for 50 Ltrs capacity electric water heater. |
| 38 | Taking down existing glass wool and supply and fixing of new superior quality glass wool in geysers of any capacity i.e. 25/50 Ltrs electric water heaters, complete all as specified and directed. |
| 39 | S&F in replacement of inner base assy chromium plated brass complete of any shape and size with inlet, outlet, thermostate slot, drain plug and clamp or bolts for fixing heating element as existing shape and size complete suitable for 25/50 Ltrs capacity electric water heater, complete all as specified and directed. |
| 40 | Taking down existing unserviceable copper flexible cable and supply and fixing of new copper flexible PVC insulated multistranded cable of size 4.0 Sqmm, complete all as specified and directed. |
| 41 | S&F in replacement of 15 Amp plug top 3 pin including making electrical connection with existing cable, complete all as specified and directed. |
| 42 | S&F in replacement of base assy gasket in 25/35/50 ltrs capacity electric water heater in any shape and size, complete all as specified and directed. |
| 43 | S&F in replacement of safety valve, suitable for 25/50 ltrs capacity gysers/ water heaters, complete all as specified and directed. |
| 44 | S&F in replacement of fastner bolt as per site requirement where is required, complete all as specified and directed. |
| 45 | Taking out defective/ burnt out PVC exhaust fan motor of size 150mm to 300mm sweep (Make of fan : Bajaj, Crompton, Havells) and supply and fixing of new PVC exhaust fan copper motor of existing makes/ shape/ size, 230 volt 50 Hz single phase AC supply, in Offrs/ JCOs/ ORs Married/ OTM Accn under GE (North) Udhampur, complete all as specified and directed. |
| 46 | S&F in replacement of PVC rigid exhaust fan plastic blade for 150-300mm sweep fans including locking nut, complete all as specified and directed. |
| 47 | M&L for sub main wiring with two single core 4.0 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size), concealed in wall for submain connection including single core 4.0 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete including taking down old existing submain wiring, complete all as specified and directed. Note :- Two runs of 4.0 Sqmm FRLS copper conductor for Phase & Neutral and one run of 4.0 Sqmm FRLS copper conductor for earthing shall be measured as one unit length. |
| 48 | M&L for sub main wiring with two single core 10.0 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size), concealed in wall for submain connection including single core 10.0 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete including taking down old existing submain wiring, complete all as specified and directed. Note :- Two runs of 10.0 Sqmm FRLS copper conductor for Phase & Neutral and one run of 10.0 Sqmm FRLS copper conductor for earthing shall be measured as one unit length. |
| 49 | S&F in replacement of MCB distribution board SPN 240 Volts 12 Way with 100 Amps rated bus bar having IP-43 protection and double metal door, concealed in wall including connection with MCBs, complete all as specified and directed. |
| 50 | S&F in replacement of MCB distribution board SPN 240 Volts 8 Way with 100 Amps rated bus bar having IP-43 protection and double metal door, concealed in wall including connection with MCBs, complete all as specified and directed. |
| 51 | S&F in replacement of MCB distribution board SPN 240 Volts 4 Way with 100 Amps rated bus bar having IP-43 protection and double metal door, concealed in wall including connection with MCBs, complete all as specified and directed. |
| 52 | S&F in replacement of MCB SPN 40 to 63 Amps 240 Volts 'C' curve 10 KA, complete all as specified and directed. |
| 53 | S&F in replacement of MCB SPN 32 Amps 240 volt 'C' curve 10 KA complete all as specified and directed. |
| 54 | S&F in replacement of MCB SP 10 to 32 Amps 240 Volt 'C' curve 10 KA, complete all as specified and directed. |
| 55 | S&F in replacement of modular electronic fan regulator, step type, two module, 240 Volts AC and making all necessary connection, complete all as specified and directed. |
| 56 | Taking down copper / aluminium point wiring of any description and in any position (light, fan, socket or power point) complete including fixture and fittings such as switches, sockets, ceiling roses, lamp holders, pendants, brackets and regulators etc. and removing material from site including making good disturbed surface to match with the existing surface, complete all as specified and directed. |
| 57 | M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in and including PVC conduit pipe (concealed) of 25mm dia medium grade with all accessories from terminal box to junction of ceiling and wall and rest of circuit conductor wire drawn into and including surface PVC rigid non metalic conduit for light/ fan point controlled by one switch including PVC sheet metal flush boxes of anyway (as per site requirement) for mounting switches, sockets, regulators etc. for fixing one light/ fan/ bell/ fan/ exhaust fan point controlled by one 5/6 A switch and making good disturbed surfaces with CM 1:4 and to match with the existing surface, complete all as specified and directed. |
| 58 | All as per serial item No. 57.00 here-in-above but for one 5 Pin socket outlet 16 Amps on independent board with using of wire of size 4.0 Sqmm, complete all as specified and directed. |
| 59 | S&F in replacement of ceiling rose of PVC Polycarbonate isolated body three terminal AC 230 volts, complete all as specified and directed. |
| 60 | S&F in replacement of 5 Amp switch piano one way, complete all as specified and directed. |
| 61 | S&F in replacement of metal clad plug & socket DB with MCBs single pole encloser with a three pin earth plug and socket suitable for 20 Amp complete with one single pole MCB 20 Amps, complete all as specified and directed. S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. Please Enable Macros to View BoQ information |