| 1 | Supplying, laying and testing XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 4 core, 25 Sqmm complete all as specified and as directed |
| 2 | Supplying, laying and testing XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 4 core, 16 sqmm complete all as specified and as directed |
| 3 | Supplying, laying and testing XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 2 core, 16 sqmm complete all as specified and as directed |
| 4 | Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in hard/dense soil complete all as specified and as directed. |
| 5 | Cutting the tar macadam road / hard standings for laying cable and excavating not exe. 60cm wide and not exc 75cm depth and getting out all as directed including filing back, consolidating etc complete and finishing it with 200mm thick PCC 1:4:8 type D-2 complete all as specified and directed |
| 6 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soil complete all specified and as directed. |
| 7 | Removing excavated materials /soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all specified and as directed. |
| 8 | S&F Double wall corrugated HDPE Pipe IS-16205, 40mm outer dia for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at site complete all as specified and as directed |
| 9 | S&F galvanised iron pipes 40 mm dia,. light grade, with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors complete all as specified and as directed |
| 10 | S&F 25 Watt Street light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resistance of IK08 LED street light complete all as specified and as directed.Make:-Havells/Crompton/Bajaj or any equivalent make as specified in list of makes of particular specification as approved by GE. |
| 11 | S&F 45 Watt Street light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP66 protection and impact resistance of IK08 LED street light of 45 Watt complete all as specified and as directed Make:-Havells/Crompton/Bajaj or any equivalent make as specified in list of makes of particular specification as approved by GE. |
| 12 | S&F LED flood light 100 Watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed .Make :- Havells/Crompton/Bajaj or any equivalent make as specified in list of makes of particular specification as approved by GE. |
| 13 | S&F 200 Watt new generation energy saving and environmental friendly long life made up of pressure die cast aluminium housing Flood Light with PC diffused lens enclosure over LED for glare free light all as specified and as directed.Make :- Havells/Crompton/Bajaj or any equivalent make as specified in list of makes of particular specification as approved by GE. |
| 14 | M&L for earthing complete with galvanised iron strip 32×6mm as earthing lead, buried directly in ground (earth pit not less than 2.25 metre depth below normal ground level) with top edge of plate at a depth not less than 1.5 mtr below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 04 mm dia with and including bolts, nuts, check nuts and washers of galvanised iron or steel and riveted to earth plate and one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 15 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and including flatiron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 03 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including neessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge. Notes:- 1. The rate quoted shall be deemed to include for all the above provisions. 2. PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting maner . |
| 15 | M&L for preparation of old painted steel/PCC/RCC surface of LT poles and applying two coats of aluminium paint approx 6 mtr height on outer surfaces of pole from 1.5 m above the couping/ground level up to the top of steel poles including painting of MS cross arms, clamps, nuts and bolts etc and painting alternative black and white strips of 30 CM height with two coats of synthetic enamel paint up to 1.5 mtr height from the ground/couping level including writing pole No. with letters of size 25 mm height on pole/ plate with Black synthetic enamelled paint complete all as specified and as directed |
| 16 | Supply and fixing steel tubular swaged poles with cast iron base plate, final taper plug bolts, nuts, screws as specified type 410 SP-31 (9.0 Mtr long) incl embossing the manufacturers name and IS No of pole and erecting in position all as specified and directed incl painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat red oxide primer and painting of 30 cm wide red and white strips upto 1.5 mtr from bottom of the errected pole including marking of pole number complete all as specified and directed . Note: Necessary excavation, earth work and PCC shall be measured and paid for separately |
| 17 | Excavation in trenches, not exceeding 1.50m wide andexceeding 1.5m but not exceeding 3.0m in depth for foundations, trenches of cable or pipe lines etc or and getting out in hard/dense soil complete all as specified and as directed. |
| 18 | M&L fpr plain cement concrete 1:4:8, type D2 (using 40mm graded stone aggregates) as in foundation of poles complete all as specified and as directed. . |
| 19 | M&L for plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling for poles complete all as specified & directed |
| 20 | M&L for plain cement concrete 1:2:4, type B1 (using 20mm graded stone aggregates) as in coping, bed block etc including necessary from work complete all as specified and as directed. . |
| 21 | Supplying, fixing, connecting and testing time switch panel box size 400mm x 350mm x 170mm dust and vermin proof made of 16 guage MS sheet factory made duly painted with two coats of synthetic enamel paint recommended colour over a coat of red oxide primer and mounted inside the following:- (a) MCB triple pole 32 Amps 230 Volts-01 No(b) Analog/Digital electro mechanical time switch 24 hours with minimum setting 30 minutes for daily working contact rating 16 Amps, 240 volts, AC with initialcharging battery backup having supply and reserve failure upto 150 Amp hours and coil voltage 415 Volts.(c) AC contractror, 3 pole, ML-2 415 volt, 50 Hz(d) Internal wiring with PVC insulated stranded copper conductor of suitable size and making electric connection - 01 No(e) By pass MCB single pole, 32/40Amp, 230 volts- 01 NoNote: Time switch pannel box shall be fixed on one pole/wallin feeder pillar box with flat iron clamp 40x6 mm or other suitable fixing arrangement Please Enable Macros to View BoQ information |