| 1 | Taking down cement plaster on wall, ceiling, chajjas, roof projections, lintel, etc of any description including raking out joints, hacking for key and scrubbing down with water etc and disposing off the rubbish materials out side MD land complete all as specified and directed. |
| 2 | M&L for 20 mm thick rendering in cement mortar (1:4) on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid seperately under relevant item of schedule 'A'. |
| 3 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and directed. |
| 4 | M&L for 15mm thick rendering in cement mortar 1:6 on fair face/other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified and directed. |
| 5 | M&L for rendering 5mm thick in cement mortar 1:3 on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for preparing newly plastered or unplastered surface of walls and applying two coats of fire retardent paint over one coat of suitable primer as per manufacturer instructions complete all as specified and directed.Note: The work shall be executed through manufarture approved by GE. |
| 7 | M&L for complete removal of existing treatment on old decorated wall surfaces and applying two coats of fire retardent paint over one coat of suitable primer as per manufacturer instructions including preparation of surfaces complete all as specified and directed.Note: The work shall be executed through manufarture approved by GE. |
| 8 | M&L for preparing newly plastered or unplastered surface of walls and applying two coats of fire retardent paint over one coat of suitable primer as per manufacturer instructions in the form of camouflage pattern complete all as specified and directed.Note: The work shall be executed through manufarture approved by GE. |
| 9 | M&L for complete removal of existing treatment on old decorated wall surfaces and applying two coats of fire retardent paint over one coat of suitable primer as per manufacturer instructions including preparation of surfaces in the form of camouflage pattern complete all as specified and directed.Note: The work shall be executed through manufarture approved by GE. |
| 10 | M&L for preparing newly plastered or unplastered surface of ceilings and applying two coats of fire retardent paint over one coat of suitable primer as per manufacturer instructions complete all as specified and directed.Note: The work shall be executed through manufarture approved by GE. |
| 11 | M&L for complete removal of existing treatment on old decorated ceilings surfaces and applying two coats of fire retardent paint over one coat of suitable primer as per manufacturer instructions including preparation of surfaces complete all as specified and directed.Note: The work shall be executed through manufarture approved by GE. |
| 12 | Demolition of brick work built in cement mortar of any description complete all as specified and directed. |
| 13 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 14 | Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete suirface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and directed. |
| 15 | M&L for water proofing treatment to RCC roof slab including parapet comprising of the following course of tretment/specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surface of roof including parpet surfaces. Bitumnious primer shall be 'Tar Mastic' manufactured by M/S STP LTD or 'EMW FLATE; manufactured by M/S Texsa India Ltd. (b) Over the priming coat laying one layer APP based polymeric membrane with non woven polyster fabric weight not less than 160 gms per sqm. Polymeric membrane shall be taken to a height of 60cm (mim) and than inserted th groove of perafit wall and shall be finished a membrance flashing (c) Application of two coats of Bituminous aluminum paints over the polymeric memnrance after necessary preparation and cleaning, Thickness 3mm.Note :- Laying APP based polymeric membranceshall be done by tourch on mathod or as per manufacture insturction. (ii) A minimum overlap of 100 mm shall be maid at the end 75mm shall be maid at the side and sealed overlaped and joint as per manufacture instructions. Make :- \\"SUPER THERMOLAY\\" manufacturer by STP Ltd of MOPLY FP manufacture by Texsa India Ltd. |
| 16 | M&L for 10mm thick screedd bed or bedding layeres in cement mirter (1:4) in order to maintain proper slope over existing roof surface for applying single component acrylic polymner modified, fininshed even and smooth without using extra cement mixed with water proofing compound complete all specified and as directed. Note :- Polymeric membrane and WPC shall be measured and paid spearately under relevant items of this Sch 'A'. |
| 17 | M&L for 25mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) mixed with water proofing compound and laid on RCC slab as base layer for roof tratment rufning the topo surface of concrete by using broom stick while the cocrete is green complete all as specified. Note:- WPC paid separatly under relivant items. |
| 18 | M&L for 80mm thick PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as floors, finishing cement concrete surface even & fair without using extra cement etc complete all as specified and directed. |
| 19 | (a) Surface Preparation:Cleaning of concrete surface to remove all loose gravel, dirt, oil, grease and foreign matter completely by jet of dry air and clean the surface mechanically or by grinding to make it absolutely smooth before application. Ensure that new concrete must be 28 days old. The surface moisture content should be within 5%. Surface defects exposed during preparation such as shrinkage cracks, blow holes, minor honey combs, and minor damages, etc. shall be treated properly by using Repair Mortar.(b) Floor Hardener Application with Epoxy bonding agent with power floated or vacuum dewatered equipmentAfter Cleaning the substrate, apply ShaliFloor LH with a low-pressure sprayer or scrubber. Allow 20 minutes to keep the floor wet after application. Any portion begins to dry should bere-mist with material. Interval between two coats is 24hrs. Allow the material to dry. Broom the surface to remove pudding. After the material dries clean up the excess material with scrubber. Normally a two or three coat application is recommended for complete treatment; however, very dense, well trowelled surfaces such as granolithic toppings, power floated or vacuum dewatered concrete will generally require only a single coat. Allow foot traffic after one hour whereas allow vehicle after 24 hours. Do not allow water to contact with the coated floor for 24hrs. for proper curing. Humidity will delay curing of coating. For the successful application of the product require sahigh degree of skill, special tools and equipment and to be applied by authorized STP applicator. |
| 20 | M&L for cutting and filling of expansion grooves/joints as per manufacturers instruction complete all as specified and directed. |
| 21 | M&L for MS flat iron bent to shape, holes drilled etc complete as in wind ties etc including one coat of red oxide paint incl dismantling old steel complete all as specified. |
| 22 | S&F wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples with mesh size 12mm complete all as specified. |
| 23 | M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 24 | Demolition of cement concrete (Reinforced) of any description in any position not otherwise specifically provided for complete all as specified. |
| 25 | M&L for TMT bar 10 mm dia and over cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 26 | Use and waste of formwork to flat rough finished surface of concrete, as in soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified |
| 27 | Use and waste of formwork edge of concrete flats, treads breaks in floors, window cill, concrete railing openings in concrete walls floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 28 | M&L for RCC nominal mix type A1 1:1.5:3 using 20mm gradded stone aggregate Slabs supported on walls, beams and columns in floors, shelves, platform, lintel, deck slabs and the like complete all as specified and directed. |
| 29 | S&F 0.71mm thick plain, aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip, crumple joint and straight flashing (length and girth as fixed) with brass screws and washers complete all as specified and directed. |
| 30 | Demolition of cement concrete (un-reinforced) any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 31 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, finishing cement concrete surface even & fair without using extra cement including filiing the joints with bitumen & sand in 2:1 proportion etc complete all as specified and directed. |
| 32 | M&L for PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in surface channel or drain including use of necessary from work for fair finished surface complete all as specified and directed. |
| 33 | M&L for cement concrete (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified. |
| 34 | Removing building materials and debris (other than excavated earth) to a distance of 5 KM inside MD Land at locations specified including loading and dumping/ leveling at the destination complete all as specified and directed. |
| 35 | M&L for preparation of old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 36 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed. |
| 37 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed. |
| 38 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated, IS 694 unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding rawn through and including metallic rigid conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes duly painted with anticorrosive paint, concealed in walls with bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sunken for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications all as specified and as directed for (a) One light point controlled by one way switch 5/6 amps. |
| 39 | Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V all as specified and directed. |
| 40 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and directed. |
| 41 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr-in-Charge. |
| 42 | S & F Flameproof weatherproof 4 Way control panel SPN DB in cast alumiunm alloy LM6 construction for group IIA/IIB considering Incoming -01 Nos of 32A MCB SPN, Outgoing- 02 Nos MCB SP 6-32 A, concealed in wall complete all as specified and directed. |
| 43 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified and as directed. |
| 44 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation of poles/stays/cables etc and getting out in any type of soil. |
| 45 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers n.exc 25cm. |
| 46 | Removing excavated material n.exc 50m and depositing were directed at a level n.exc. 1.5m above the starting level. |
| 47 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed by Engr-in-Charge. (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I) |
| 48 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed by Engr-in-Charge. |
| 49 | Supply and fixing 40 mm dia GI tubing light grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified and directed. |
| 50 | M&L for air termination, single pointed aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangement on roof including taking down old one complete all as specified and as directed. |
| 51 | M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed copper/aluminium bi-metal strip including 3 Nos 8 mm dia 25 mm long hex head screw including taking down old one complete all as specified and directed. |
| 52 | M&L Aluminium stip 25 x 3.15 mm fixed on and including saddles, pvc insulators and fixing screws etc. for roof conductors and down conductors including taking down old unsv strip. |
| 53 | S&F galvanised iron strip of size 32 x 6 mm buried in ground or fixed on wall mounted on suitable sized porcelain insulators ( on floor and wall only) including cutting cavities for fixing of porcelain insulators and finishing with cement plaster on wall /floors and connected to test point including bending, jointing at test points with GI nuts, bolts, with lead washers, jointing strips at all joints incl. making good the disturbed surfaces including taking down old one complete |
| 54 | Supply and laid GI Pipe medium grade complete including fttings 40 mm dia including taking down old one complete |
| 55 | Fabrication and instalation of cubical shape enclosure made of MS/CRCA sheet 2.00mm thick with front detachable cover, anodixed fiexing screw cap, washers 4 Nos to be mounted on wall with wooden plugs & screws 4 Nos duly painted inside and outside by two coats of aluminium paints over a coat of redoxide primer overall dimension of enclosure 150mm x 150 mm x 100 mm (depth) for fixing inside test point terminal block including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 56 | Earthing complete with galvanised steel earth plate electrode 60 cm × 60cm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including taking down the old one complete all as specified and directed by Engr-in-Charge. |
| 57 | M&L for Pre-cast cement concrete block masonry in Type B1 ( 1: 2:4 with 20mm stone aggregate ) set in CM 1:4 with solid blocks, exc. 10 cm in width and setting in mortar,complete for fixing Earth Strip insulator complete all as directed Please Enable Macros to View BoQ information |