| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur Name of Work: CERTAIN REAPAIR TO SECURITY WALL, GATES, CONCERTINA COIL FENCING AND OTHER RELATED WORKS, SEPTIC TANK, MANHOLES AND SEWAGE LINE TECH AREA AT AF STN GORAKHPUR. Contract No.: GE(AF)/GKP/E-09 OF 2026-27 File No. 9447/E8 Serial Page No.15 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of item Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and roof and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 3 | Ditto here in above but in RCC ( reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 4 | M&L for PCC (1:4:8) type D-2, (using 40mm graded stone aggregate) as in foundation, mass fillings,sub base etc complete all as specified and directed. |
| 5 | M&L providing pre-cast reinforced cement concrete with RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab of drains, manhole covers set in cement mortar 1:4 etc with necessary use and waste of form work complete all as specified and directed. |
| 6 | M&L plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate in surface channels and drains complete all as specified and directed. |
| 7 | M&L plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping complete all as specified and directed. |
| 8 | M&L mild steel TMT bars 10 mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 9 | M&L mild steel TMT bars 6 to 8 mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 10 | Extra for forming fair finished drain or channel up to 30 cm inner girth in cement concrete using extra cement incl forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 11 | Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed. |
| 12 | M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed. |
| 13 | All as per Item Noa above here in above but except bricks complete all as specified and directed. |
| 14 | M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed. |
| 15 | Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed |
| 16 | M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed |
| 17 | M&L for preparing newly plastered surfaces of wall and applying two coat of exterior emulsion paint camouflage pattern over one coat of primer and 2mm wall care putty complete all as specified and directed. |
| 18 | M&L Non skid joint less colour Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick cement mortar 1:6 bedding including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 19 | S&F Glazed ceramic coloured tiles 300x450x7mm thick laid on vertical surfaces such as skirting dados risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 10mm thick rcement plaster in cm (1:4) including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed |
| 20 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern, with EWC including p or s trap ,seat cover , including connection to trap /drain and to flushing pipe anti syphonage pipe etc complete including making good floor complete all as specified as directed. |
| 21 | S&F in repair vitreous chaina squating pan orissa pattern size 580X 440mm white with intregal foot rest complete including lime concrete(excl flushing cistern and flush pipe) but connecting to flushing pipe, anti-symphonage pipe etc complete all as specified and directed. |
| 22 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 23 | S&F in repairs 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed. |
| 24 | S&F in repairs 15 mm bore PVC connection 60cm long with brass nuts and washers on both ends all as in repairs specified and directed. |
| 25 | S&F in repairs bib taps 15 mm bore brass, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 26 | S&F in repairs 15 mm dia brass angle cock fancy type, with capstan head chromium plated screwed down high pressure with or without lettered with long screwed shank and fly nut screwed complete all as specified and directed. |
| 27 | S&F in repairs 15mm bore pillar tap fancy type cast copper alloy chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screw shanks screwed for iron pipe or union complete all as specified and as directed. |
| 28 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed. |
| 29 | S&F for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches as in floors, all as specified & directed. |
| 30 | S&F for 110mm bore PVC (SWR) bends provided with access door all as specified & directed . |
| 31 | S&F for 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches as in floors, all as specified & directed . |
| 32 | S&F for 75mm bore PVC (SWR) bends provided with access door all as specified & directed . |
| 33 | S&Fin repair PVC (SWR) P or S trap 125/110 mm,setting and jointing with solventcement complete all specified and directed. |
| 34 | M&L in repair 75mm dia PVC (SWR) floor trap, plane with grating including jointing with solvent cement complete all specified and directed. |
| 35 | Excavation in trenches n.exc 1.5M wide and n.exc 1.5M depth and n.exc 10 Sqm on plan and getting out in any type of soil (for manholes and sewage lines, drain etc.) complete all as specified and directed at site. |
| 36 | Returning filling in including spreading watering and well raming in layer . Exc 25 cm each in loose/soft soil complete all as specified and directed. |
| 37 | Removing excavated material to a distance not exc 50 m and depositing where directed, complete all as specified and directed |
| 38 | Demolition and breaking up 150mm dia drain pipes ( salt glazed ware, AC or reinforced Concrete ) set in cement mortar complete all as specified. |
| 39 | M&L for 150mm bore pipe concrete bed to drain pipes in PCC 1:4:8 type D2 using 40mm grade stone aggregate including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 40 | S&F Reinforced conctrete 150mm bore of pipes class NP2, laid and jointed complete with collars all as specified and directed. |
| 41 | M&L for cutting into existing manholes for connecting new drains and making good to pipe and rendering cutting out existing bending for and forming branch channel in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for pipe 150mm bore complete all as specified and directed. |
| 42 | De-silting of sewer line 150/200mm dia with mechanical device like super sucker machine, high pressure jetting machine/gantry machine or any other mechanical device & cleaning site all as specified and directed by Engineer-in-Charge. |
| 43 | Material and labour for Cleaning/removal of blockage from bathroom,EWC/IWC (any type), kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto first manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users,including refixing of oval assess door covers with new nuts & washers and refixing manhole covers, including removing of all wastes, solid or liquid sludge and depositing the sludge in a pit (at empty/open area) of suitable size at a distance exceeding 50 metres from the building where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified andas directed .(a) Contractor must employ Minimum 2 Nos labourers daily deployed in Tech area, complete all as specified and as directed . (b) Contractor or his representative shall report daily at 09.00 AM except on Sunday/ National holidays in the office of Engineer-in-Charge/ Complaint cell to receive complaint slip and necessary directions. Complaints received through telephonic message from JE/ Engineer-in-Charge shall also be attended on the same day and the completion of work shall be reported by 05.00 PM of every working day to JE/ Engineer-in-Charge. (c) In case of non attedence of complaints against Item No 42 by the contractor on the same day, a penalty of Rs 200/- per complaint per day and for complaints against Item No 43, a penalty of Rs 100/- per complaint per day will be recovered from the contractor due complete all as specified and as directed . (d) The cost for all necessary T&P such as green female bamboo strips, iron rods, sewage rodding machine, buckets, rope, ladder, safety mask, bleaching powder etc and all other other materials for execution of the work shall be included in the unit rate complete all as specified and as directed . (e) A complaint register shall be maintained by JE and proper record of complaints received and attended with date and time shall be recorded and shall be signed daily by both the parties. Complaint register shall be kept on record of Engineer-in-Charge after completion of work complete all as specified and as directed . |
| 44 | Cleaning of septic tanks / Manholes including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including site clearance to a distance of 3 Metre around septic tank complete all as specified and directed for the following capacity :- (a) For Manhole n. exc 1.50m deep. |
| 45 | (b) For Manhole exc 1.50m but n.exc 3m deep. |
| 46 | (c) For septic tank of 25 to 50 user capacity. |
| 47 | Dewatering of septic tank, sump wells including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the same including site clearance to a distance of 3 metre around complete all as specified and directed. |
| 48 | S&F in repair CP Grating 125 mm size complete all as specified as directed. |
| 49 | S&F in repair vitreous china urinal half stall type white complete including providing and fixing plugs,etc all fittings including spreader (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed. |
| 50 | S&F in repair PVC waste pipe 32/40mm dia for wash basin/sink/urinal ISI marked |
| 51 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins facia etc upto 3 storie height mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished the surface fair and even (without using extra cement), complete all as specified. Note 1: - Supply only water proofing compound shall be measured and paid for separately. |
| 52 | Supply only integral water proofing compound (ISI marked). |
| 53 | M & L for rendering 15 mm thick in cemnet mortor 1:6 on fiar faces of brick work or concrete surfaces & finish the surface fair and even (without using extra cement), complete all as specified. |
| 54 | M & L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & over a coat of alkali priming coat and 2 mm thick wall care putty, complete all specified and directed |
| 55 | Raking out joints/ pointing to brick work or brick tiles, laid flat, in floors, surface channels, roofs, etc built in cement mortar complete all as directed |
| 56 | M&L for Keyed pointing to brick walls in cement sand mortar in 1:4 compete all as directed |
| 57 | M&L Providing cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate in coping, fixing MS post at top of wall, roof Krebs or mud stops, rounded or chamfered on edge including necessary form work complete all as specified and directed. |
| 58 | Dismantling of structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 59 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 60 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground post embeded in cement concrete complete all as specified and directed. |
| 61 | Taking down chain link fencing fixed to any type of standard rails, straining bolts etc complete all as specified and directed. |
| 62 | M&L PCC 1:3:6 type C2 40mm graded stone aggregate as in fixing of fencing post and mass complete all as specified and directed. |
| 63 | S & F mild steel work as in posts and struts in fencing incl cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets incl all necessary drilling, bolting or rivetting etc and similar work confirming to Fe 290 Gd E-165 complete all as specified and as directed. |
| 64 | Supply only chain link MS galvanised fencing, any size or type of minimum dia 3.15 mm or above as directed.Note:- weight of chian link fence shall be decided through BOO. |
| 65 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standard rails, straining bolts etc.complete all as specified and directed. |
| 66 | M&L for mild steel round bar 10 to 12mm dia confirming Fe-410-W (Gde.E-250) Fe 290 (Gde - E-165) as in stiffeners to chain link fencing etc all as specified and directed. |
| 67 | S&F mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed the other each screwed end to be fitted with washers and one hexagonal nut but length of bolt exc. 5cm and n. exc. 10cm long and bolt one side embedded in concrete posts etc complete to fix fencing wire dia of shank11to15mm complete all as specified and directed. |
| 68 | M&L for two coat synthetic enamel paint over a coat of red oxide primer on new steel surface of any description over 10cm width or girth incl preparation complete all as specified |
| 69 | M&L Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing in repairs to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. as directed (each line of wire to be measured) complete all as specified and directed. |
| 70 | Lobour only for Restraining, resecuring including making good staples of old barbed wire (each line of wire to be measured) complete all as specified and directed. |
| 71 | S&F 610mm dia punched tape concertina coil (effective dia 550mm at strech length of coil 6m) with two handle and spikes at both end of coil with dovetail clips [18 SWG], incl razor wire [7 No], 6m length of each wire medium size, barbed length 20mm width 14mm, incl 51 pins, 128 nos of clips in each coil incl 230gm/ Sqm Zinc coating on core wire complete all as specified. |
| 72 | Dismantling of concertina coil 600mm dia any shape including razor wire of six linc etc all as specified and directed Note :- Concertina coil and six link razor wire shall be measured as one Rm Complete all as specified and dirwected at site. |
| 73 | M&L for doublecharged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles nog exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 including dismantling of tiles, complete all as specified and directed. |
| 74 | M&L 100mm thick PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in hard standing finished even and smooth without using extra cement including spike rolling to surface or making impression of expanded metal whilst the concrete is green complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |