| 1 | Dismantling ACSR conductor including jumper from existing overhead service feeder/line, any size and description complete all as specified and directed. |
| 2 | Dismantling earth wire including cradles from existing overhead service feeder/line, of any size and description complete all as specified and directed. |
| 3 | Dismantling insulators any description, type any size complete all as specified and directed. |
| 4 | Dismantling cross arms made of MS section, any size and description complete all as specified and directed. |
| 5 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120Sqmm 3.5 core complete all as specified and directed. |
| 6 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70Sqmm 3.5 core complete all as specified and directed. |
| 7 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50Sqmm 3.5 core complete all as specified and directed. |
| 8 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed. |
| 9 | M&L for supply, laying and testing XLPE cable, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and directed. |
| 10 | Taking down LT UG cable carefully (without damaging, old bricks, cable covers, GI pipe ) for reuse from trenches fixed on wall/floor/poles for reuse including required earth work (Excavation, returning filling and removal of surplus excavated material) complete all as specified and directed.Note : Obtained material( i.e cable, cable covers, protection pipe etc ) shall be kept in safe custody of contractor for re-use of deposited to MES store yard as ordered by the Engg-in-charge. |
| 11 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed. |
| 12 | Returning filling in excavated material including spreading, levelling, watering and well ramming in layer n.exc 25 cm thick complete all as specified and directed. |
| 13 | Removal of excavated material (soils) to a distance n exc 50m where directed complete all as specified and directed. |
| 14 | M&L for supply and laying sand cushioning with local dry and clean sand over and under the cable for protection of cable , 80 mm thick before laying the cable and after laying the cable complete all as specified and directed. Note:- Only punned thickness of 180mm shall be measured for payment. |
| 15 | M&L for supply and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed. |
| 16 | M&L for supply, installation, connecting, commissioning and testing CPRI approved factory fabricated LT distribution panel board , in repair, outdoor type with canopy, both side operable including looking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, free standing/ floor mounting, dust and vermin proof,IP 54 protection, fabricated from 3.15 mm thick CRCA MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated high conductivity alluminium bus bar, prewired with suitable size of copper wiring cable, suitable earth strips conforming to IS, cable glands, lugs etc including required PCC work and Iron work for fixing arrangement at site complete all as specified and as directed. The LT panel shall comprising of the following:- (A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ 320amps 35/36KA electronic /micro processor -01 No. (B) OUTGOING (i) Digital Multifunction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED Type Phase indicator lamps for three phases set of three - 01 set (iii) Bus bar chamber having insulated alluminium bus bars, each suitable for three phases and neutral -01 Set (iv) MCCB, 4 Pole,415V, 50HZ 200 Amps 25KA fixed thermal and fixed magnetic -01 Nos(v) MCCB, 4 Pole,415V, 50HZ 160 Amps 25KA fixed thermal and fixed magnetic -01 Nos(vi) MCCB, 4 Pole,415V, 50HZ 100 Amps 16KA fixed thermal and fixed magnetic -02 Nos(vii) MCCB, 4 Pole,415V, 50HZ 63 Amps 16 KA fixed thermal and fixed magnetic -02 Nos(viii) Spare space for MCCB of same capacity -01 NosNote : (i) PCC work and Iron work shall be measured and paid separately under respective item. (ii) The contractor shall get approved the design of LT panel fromEnng-in-charge before procurment.Contractor shall produce the invoice and MTC to the Engineer-in-charge who shall verify the genuineness of Invoice, recorded in MB and kept in record duly defaced. Production of Invoice and MTC is mandatory along with RAR. |
| 17 | M&L for supply, installation, connecting, commissioning and testing CPRI approved factory fabricated LT distribution panel board , in repair, outdoor type with canopy, both side operable including looking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, free standing/ floor mounting, dust and vermin proof,IP 54 protection, fabricated from 3.15 mm thick CRCA MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated high conductivity alluminium bus bar, prewired with suitable size of copper wiring cable, suitable earth strips conforming to IS, cable glands, lugs etc including required PCC work and Iron work for fixing arrangement at site complete all as specified and as directed. The LT panel shall comprising of the following:- (A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ 200Amps 25KA electronic /micro processor -01 No. (B) OUTGOING (i) Digital Multifunction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED Type Phase indicator lamps for three phases set of three - 01 set (iii) Bus bar chamber having insulated alluminium bus bars, each suitable for three phases and neutral -01 Set (iv) MCCB, 4 Pole,415V, 50HZ 160 Amps 10KA fixed thermal and fixed magnetic -02 Nos(v) MCCB, 4 Pole,415V, 50HZ 100 Amps 10KA fixed thermal and fixed magnetic -02 Nos(vi) MCCB, 4 Pole,415V, 50HZ 63 Amps 10 KA fixed thermal and fixed magnetic -02 Nos(vii) Spare space for MCCB of same capacity -01 NosNote : (i) PCC work and Iron work shall be measured and paid separately under respective item. (ii) The contractor shall get approved the design of LT panel fromEnng-in-charge before procurment.Contractor shall produce the invoice and MTC to the Engineer-in-charge who shall verify the genuineness of Invoice, recorded in MB and kept in record duly defaced. Production of Invoice and MTC is mandatory along with RAR. |
| 18 | M&L for supply, installation, connecting, commissioning and testing CPRI approved factory fabricated LT distribution panel board , in repair, outdoor type with canopy, both side operable including looking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, free standing/ floor mounting, dust and vermin proof,IP 54 protection, fabricated from 3.15 mm thick CRCA MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4Nos insulated high conductivity alluminium bus bar, prewired with suitable size of copper wiring cable, suitable earth strips conforming to IS, cable glands, lugs etc including required PCC work and Iron work for fixing arrangement at site complete all as specified and as directed. The LT panel shall comprising of the following:- (A) INCOMING (i) MCCB, 4 Pole, 415V, 50HZ 250Amps 25KA electronic /micro processor -01 No. (B) OUTGOING (i) Digital Multifunction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED Type Phase indicator lamps for three phases set of three - 01 set (iii) Bus bar chamber having insulated alluminium bus bars, each suitable for three phases and neutral -01 Set (iv) MCCB, 4 Pole,415V, 50HZ 100 Amps 16 KA fixed thermal and fixed magnetic -01 Nos(vi) MCCB, 4 Pole,415V, 50HZ 63 Amps 16 KA fixed thermal and fixed magnetic -05 Nos(vii) Spare space for MCCB of same capacity -01 NosNote : (i) PCC work and Iron work shall be measured and paid separately under respective item. (ii) The contractor shall get approved the design of LT panel fromEnng-in-charge before procurment.Contractor shall produce the invoice and MTC to the Engineer-in-charge who shall verify the genuineness of Invoice, recorded in MB and kept in record duly defaced. Production of Invoice and MTC is mandatory along with RAR. |
| 19 | M&L for supply, installation, connecting, commissioning and testing CPRI approved factory fabricated bus bar panel board , in repair, outdoor type, both side operable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, free standing/ floor mounting, dust and vermin proof, fabricated from 3.15 mm thick CRCA MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade with 4Nos 200 Amps insulated high conductivity copper bus bar, conforming to IS, cable glands, lugs etc including required PCC work and Iron work for fixing arrangement at site complete all as specified and as directed. Note : (i) PCC work and Iron work shall be measured and paid separately under respective item. (ii) The contractor shall get approved the design of LT panel fromEnng-in-charge before procurment.Contractor shall produce the invoice and MTC to the Engineer-in-charge who shall verify the genuineness of Invoice, recorded in MB and kept in record duly defaced. Production of Invoice and MTC is mandatory along with RAR. |
| 20 | S&F in repairs PVC insulated, PVC sheathed copper conductor round flexible industrial cable of size 1.5 sqmm 3 core, 1100 volt grading conforming to iS:694 fixed with suitable copper lugs complete all as specified and directed. |
| 21 | S&F in repair LED street light fitting based 70 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 22 | Supply, & Fixing in repair, weather/ dust, vermin proof factory made junction box of size 250x200x100mm made of 2mm thick CRCA sheet complete with inside, outside powder coated with rubber gasket packing, with suitable size 32Amps TPN/Fore pole aluminium bus bar duly insulated (including self insulated) maintaining proper space for each bus bar, & proper arrangement for passing incoming/ outgoing LT cable and fixed to pole with 02 Nos MS clamps, Nuts bolts and washer etc complete including self closing locking arrangement complete all as specified and directed by engineer in charge. |
| 23 | M&L for boring of holes by trenches less technology using machine suitable for inserting 40mm dia (min) GI pipe so as to cross the road without damaging top surface of road including getting out and disposal of excavated earth, at a lead up to 50m and lift up to 1.5m complete all as specified and directed. |
| 24 | S&F Precast reinforced cement concrete (M35 grade), factory made suitably reinforced blocks as cable route indicator, size 50x20x10cm duly painted with white synthetic enamel paint and writing/ inscribe letters & arrow (indicating direction) with black synthetic enamel paint on both side of block as 'MES LT CABLE' in specified font (not less than 60mm ht) embedded in PCC M15 (Nominal Mix) of size 600mmx200mmx300mm including required earth work complete all as specified and directed.NOTE : The reinforcement in RCC shall not be less than as minimum reinforcement required as per IS. |
| 25 | M&L for supply and fix in repair 40mm dia GI pipe 'Light' grade with all fitting for cable protection passing under road/floor or for fixed to wall complete all as specified and directed. |
| 26 | M&L for supply and fix in repair 50mm dia GI pipe 'Light' grade with all fitting for cable protection passing under road/floor or for fixed to wall complete all as specified and directed. |
| 27 | M&L for supply and fix in repair 80mm dia GI pipe 'Light' grade with all fitting for cable protection passing under road/floor or for fixed to wall complete all as specified and directed. |
| 28 | M&L for Earthing with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized Flat iron of size 25x4mm as earth lead strip by means of bolts, nuts, check nuts & washers, provision of 40mm GI pipe light grade as watering pipe with funnel and wire mess, 40mm GI pipe light grade as earth lead (GI strip) protection pipe, RCC test chamber with cover, filling charcoal and salt in 15mm thick alternative layer starting from charcoal bottom layer to ensure packed thickness not less than 15 Cm on all sides of earth plate complete all as shown in electric plate no 3, connected to earthing test point including required earth work (excavation, returning filling and removal of surplus excavated soil) and testing on completion complete all as specified, shown/indicated on Drg and as directed by Engg-in-charge. |
| 29 | Laying only and testing XLPE cable in trenches, any description, size up to 150Sqmm cross sectional area complete all as specified and directed. Note : (i) Cable obtained from item No 10 Here -in-above shall be used. Required earth work shall be measured and paid separately under respective item |
| 30 | Laying only and cable protection cover in trenches, any description, size and pattern complete all as specified and directed. Note : (i) Cable protection cover obtained from item No 10 Here -in-above shall be used. |
| 31 | Laying only cable protection pipe in any location, any description and size complete all as specified and directed. Note : (i) Pipe obtained from item No 10 Here -in-above shall be used. Required earth work shall be measured and paid separately under respective item |
| 32 | M&L for mild steel framed work such as in grills gratings, sun shed cover fixed with nut bolts incl, cutting drilling holes etc., with ends of bars shouldered and/ or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed baluster, walk ways, railings, framed work or water tanks and similar work conforming to Fe 290 gde E 165, including dismantling of old MS work complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |