| 1 | Dismantling/uprooting of pre-stressed concrete/steel poles of any size and shape including taking out dismantled portion of poles embeded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal there off complete all as specified and directed. |
| 2 | Dismantling cross arms of MS channel or angle sections etc. and removing unserviceable materials from the site complete all as specified and directed. |
| 3 | Dismantling of ACSR conductors or disturbed span including line spacer and keeping serviceable materials in safe custody for re-use and removing unserviceable materials from the site complete all as specified and directed. |
| 4 | Dismantling insulators of any type and removing unserviceable materials from the site complete all as specified and directed. |
| 5 | Dismantling stay assembly of any size and removing unserviceable materials from the site (s), complete all as specified and directed.a) Unserviceable stay assembly shall be taken off/dismantled at ground Level and making good disturbed ground surface.b) Rate shall be inclusive of necessary earthwork for demolition of cement concrete complete. |
| 6 | Excavation in trenches for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed. |
| 7 | All as per Ser item No 06.00 here in before but depth exceeding 1.5 metre and not exceeding 3.0 metre complete all as specified and directed. |
| 8 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 9 | Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and directed. |
| 10 | Material and labour for sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and directed. |
| 11 | Supply and laying bricks, common burnt clay, sub class \\"B', old size, laid in perpendicular direction to cable as cable protection complete all as specified and directed. |
| 12 | Material & Labour for GI tubing light grade of size 80 mm dia fixed on walls/ laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc including taking down of old unseviceable pipe any type and any size complete all as specified and directed.Note - Excavation to be paid separately in respective items. |
| 13 | All as per Item No 12 herein above but 100 mm dia complete all as specified and directed. |
| 14 | Supply & laying 50 mm bore galvanized steel tubing \\"light grade\\" with GI fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & directed. |
| 15 | Material and labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. |
| 16 | Material and labour for cutting of bituminious road/ hard standing/PCC path/wall up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of protection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm graded crushed stone aggregate upto existing surface level or removing any type of tiles carefully and refixing properly as per existing surface complete all as specified and as directed. |
| 17 | Material and labour for UG cable route indicator made out of 100 mm dia MS plate with 20 mm dia 50cm long MS bar as legs for writing LT and name of feeder fixing with and including necessary PCC 1:2:4 in grouting route complete all as specified and as directed. |
| 18 | Supply and laying of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoued, electric power cable (heavy duty) 1100 volts grade with stranded aluminimum conductor of size 300 sqmm 3.5 core complete all as specified and as directed. |
| 19 | All as per Item No 18 herein above but of size 240 Sqmm 3.5 Core complete all as specified and as directed. |
| 20 | All as per Item No 18 herein above but of size 95 Sqmm 3.5 Core complete all as specified and as directed. |
| 21 | All as per Item No 18 herein above but of size 70 Sqmm 3.5 Core complete all as specified and as directed. |
| 22 | All as per Item No 18 herein above but of size 50 Sqmm 3.5 Core complete all as specified and as directed. |
| 23 | All as per Item No 18 herein above but of size 35 Sqmm 3.5 Core complete all as specified and as directed. |
| 24 | All as per Item No 18 herein above but of size 25 Sqmm 3.5 Core complete all as specified and as directed. |
| 25 | All as per Item No 18 herein above but of size 16 Sqmm 4 Core complete all as specified and as directed. |
| 26 | Supply and erection of steel tubular swaged poles 9.0 mtr long complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31, providing synthetic enamel aluminium paint over one coat of red oxide primer and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr above the coping of pole starting with black strip complete all as specified & directed. Note:- (i) Earth work and PCC shall be measured and paid seperately. (ii) Description as per direction of Engineer-in-Charge shall be printed on each pole without any extra cost. |
| 27 | Material & Labour for GI Bracket fabricated out of light grade GI tubing 40mm dia or as per dia of fitting, 1.5 mtr long and along with 02 sets of suitable size of clamps and nuts and bolts to fix the bracket on Steel tubular pole 410 SP 31 complete all as specified & directed. |
| 28 | Material & Labour for drawing of PVC insulated and FR PVC Round Sheathed 1.5 SQMM, 3 core copper coductor ,industrial cable through steel tubular pole from bottom to Top hole and both side connection in Jn box MCB and Street light fitting complete all as specified and directed by Engr-in-charge. |
| 29 | Supply and fixing of junction box insulated of polycarbonate with glass fiber reinforced, size 205mm X 255mm X 112mm, environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive, rated for degree of ingress protection IP 66/67 in accordance with IEC 60529, gasket material of polyurethane and the gasket shall be internally embedded, compling with requirements of the standards IEC 60998-1, IEC 60998-2-1, IEC 60670-22 & IEC 60670-2-5, including three phase busbar with 6 Amp MCB and mounting clamp complete all as specified and directed and complying the instructions as specified in Notes here under. Notes:- (i) The manufacturer of junction box shall submit a copy of IEC certificate. (ii) For better safety the polycarbonate enclosure shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-11 DIN VDE 0304 Part 3, UL subject 94 for flammability V-2. (iii) It should be tested at glow wire test for 960 deg Cent. (iv) The impact strength of polycarbonate enclosures i.e. the degree of protection against mechanical load shall be in accordance with EN 50296-98 for IK 08. Manufacturer should submit routine test certificate for CJB/PJB. |
| 30 | Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 31 | Material and labour for Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation complete all as specified and directed. |
| 32 | Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for stay and coping for poles including necessary form work to exposed surfaces finished smooth and even complete all as specified and directed. |
| 33 | Material and labour for PCC 1:2:4 Type B-1 using 20 mm graded stone aggregate for coping of poles including necessary form work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed. |
| 34 | Supply, installing, testing & commissioning in replacement of outdoor type cubical panel board of suitable size, outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm grouted with PCC 1:2:4 type B-1, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 2 places with body and hinges should be welded with body and door) with locking arrangements and outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Copper bus bar , 3 ph (RYB) of 300 A and 1 Ph (neutral) of 150 A, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-65 and breaking capacity 65 KA (Panel No 1) also including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size complete all as specified and directed. Please Enable Macros to View BoQ information |
| 35 | Supply, installing, testing & commissioning in replacement of outdoor type cubical panel board of suitable size, outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm grouted with PCC 1:2:4 type B-1, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 2 places with body and hinges should be welded with body and door) with locking arrangements and outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Copper bus bar , 3 ph (RYB) of 300 A and 1 Ph (neutral) of 150 A, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-65 and breaking capacity 65 KA (Panel No 1) also including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size complete all as specified and directed. Please Enable Macros to View BoQ information |