| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK : IMPROVEMENT OF EXTERNAL ILLUMINATION WITH HIGH MAST LIGHTS AT CERTAIN PLACES AND SPECIAL REPAIRS FOR REPLACEMENT OF UNSERVICEABLE BLDG/ PERIPHERY SECURITY LIGHTS WITH CONNECTED ELECTRICAL WORKS FOR OTM/MD ACCN AT CHAFB CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | COMMON ITEMS APPLICABLE FOR 'JOB A' & 'JOB B' |
| 3 | Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable/pipes in loose/soft soil complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed. |
| 5 | Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 6 | M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover complete all as specified and directed. |
| 7 | Supply and laying un-reinforced precast concrete cable cover class LV Type I, flat, size 250mmx150mmx40mm complete all as specified and directed. |
| 8 | M&L for GI tubing light grade laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete for 40 mm bore size complete all as specified and directed. |
| 9 | ITEMS APPLICABLE FOR 'JOB A' |
| 10 | Supply & installation of 20 Mtr High Mast light complete, totally hot dip Galvanised, polygonal, tapered & flange mounted type, suitable for wind speed 180 kmph, double drum winch. The Mast shaft shall be in two sections with no circumferential weld and shall be stress fitted at site along with all accessories which includes lantern carriage for mounting 9 nos lumiinaries with 09 number of arms, symmetrically, provision of 9 sets of LED flood light luminaries 250 watt, stainless steel wire rope 6 mm dia, compensating disc, winch, power trailing cable 5 core 2.5 sqmm (one no of circuit per Mast), integral power tool, input supply 415 Volt, method of operation : Integral Power, control panel housing comprising of suitable timer contactor circuit for automatic ON/OFF of high mast lights, LED aviation obstruction light and lighting arrester spike. This also includes design, casting of suitable open raft shallow RCC foundation suitable for safe soil bearing capacity of 10 T/Sqmtr at the depth of 1.5 mtr below ground level along with supply of foundation bolts manufactured from specials steel with nuts washers, suitable size anchor plate templates along with erection and commissioning of high mast lighting system with modern engineering practices and pipe earthing comprising of the following :-Provision of foundation bolts with nuts, washers, suitable size anchor plate, templates as required as per manufacturer direction – 01 Set(b) Provision for LED flood light luminaries 250 Watt including all accessories - Total 8 Nos .Flood light fitting shall be measured and paid seperately(c) Provision of twin dome Aviation obstruction lights LED type.(d) Provision of control panel housing suitable control circuit for automatic ON/OFF of each high mast light alongwith necessary control for integral power tool.(e) Provn of suitable foundation for the high mast considering the safe soil bearing capacity with all materials as per manufacturer recommendations.(f) Erection of high mast with the help of suitable equipments and wiring of luminaries with all wiring materials as per manufacturer instructions. |
| 11 | g) Supply and installation of control panel complete on suitable foundation as per manufacturer instructions.(h) Testing and commissioning of high mast. Notes :-(i) Make of High Mast : Crompton Greaves/ Philips / Bajaj / Havells / Wipro / Orient Electric / Benlo(ii) High Mast should have identification mark of manufacturer.(iii) High Mast shall be installed by authorized company rep only.(iv) Make of all products & LED flood light fittings of High Mast shall be of same brand / Make or as recommended by the manufacturer. |
| 12 | S&F energy saving LED flood light fitting, 250 watt, environmental friendly, long life, die cast aluminium IP 66 comprising with electronic driver and all accessories, pre-wired, fitting to be mounted on high Mast light structure with necessary fixing arrangement with nut, bolts, washers etc as required/directed at site incl connection complete all as specified and directed. |
| 13 | Supply and lay cable in trenches/through pipes/ducts or on poles, XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed.Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately |
| 14 | M&L for boring of holes under road, pavment, hardstanding by trenchless technology using ultrasounding technique and necessary machine including HDPE pipe of 110mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 15 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of size 32 x 6 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in elecrtical plate No 3 of SSR pt I, connected to DB/earthing test point including PCC chamber , RCC cover 50mm thick with CTD 8 mm dia bars, protection pipe, funnel etc including excavation, earth work, disposal of surplus soil and earth strip protection pipe of GI 40 mm bore light grade earth strip upto 7.5 metre including testing on completion complete all as specified and directed.Note: (i) The unit rate includes 40 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes GI main earthing lead/strip of size 32x6 mm from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthing is recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the Govt till desired result is obtained (iv) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge / JE E/M and proper record shall be maintained duly signed by all concerned. (v) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised company/ lab. |
| 16 | ITEMS APPLICABLE FOR 'JOB B' |
| 17 | S&F energy saving security LED light fitting, Versatile pressure die-cast aluminium IP 65/66 with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 sqmm 3 core, fitting to be fitted on bldg / pole on extg / new mounting bracket incl taking down old/unsv fittings complete of following wattages:-Note : New GI bracket with clamp shall be measured and paid seperately |
| 18 | 60 watt |
| 19 | 70 watt |
| 20 | 90 watt |
| 21 | S&F Security light mounting bracket made out of 40 mm bore light grade GI tube of suitable length, bend to shape and fixed to wall / pole by means of 02 nos of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete all as specified and directed |
| 22 | M&L for point wiring concealed type with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable connected to common earth and earth dolly with suitable copper lugs drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade with PVC conduit accessories, incl metal flush box of 1.60 mm thick suitable for modular switches/ sockets/fan regulators including modular white cover plate and modular metal flush box with frame of required modules at site, blanking plates, brass screws, cup washers etc including all cutting / chases etc in stone/ brick masonary/ walls, pinning in stone walls / brick walls and pointing in cement mortar 1:3 to ends or edges of landing etc for concealed conduit wiring using heavy duty stone drilling/cutter machine incl taking down old/unsv wiring any type with fittings & fixtures and making good to the disturbed surfaces to match the existing complete for One light point controlled by one, one way switch 06 Amps complete all as specified and directed. |
| 23 | S&F Switch piano flush type 5/6 Amps single pole one way complete all as specified and directed |
| 24 | S&F Ceiling rose, 65 x 50 mm surface type with 3 terminals incl connection complete all as specified and directed |
| 25 | S&F Energy saving LED flood light fitting, envioronmental friendly, long life, die cast aluminium IP 66 comprising with electronic driver and all accessories, pre-wired, fitting to be fitted on wall / pole with necessary fixing arrangement with nut, bolts, washers etc as required/directed at site incl connection with PVC insulated copper conductor cable 1.5 Sqmm, 3 core incl taking down old/unsv fittings complete all as specified and directed for following wattages:- |
| 26 | 80 watts |
| 27 | 100 watt |
| 28 | 120 watt |
| 29 | 150 watt |
| 30 | S&F 1100 volt grade, heavy duty cable PVC insulated aluminium conductor, multistranded, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended incl taking down old/unsv cable complete all as specified and directed of following sizes :- |
| 31 | 6 Sqmm, twin core, flat or circular |
| 32 | 10 Sqmm, twin core, flat or circular |
| 33 | Supply and laying or fixing or passing through pipe, 1100 V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed incl taking down old/unsv cable complete all as specified and directed for following sizes :- |
| 34 | 16 sqmm 4 core |
| 35 | 10 sq mm 2 core |
| 36 | 6 sq mm 2 core |
| 37 | S&F PVC cable loop box size not less than 200mm x 140mm x 95mm, outdoor type, duly fitted on wall/pole with suitable clamp, nuts, bolts & washers incl to accommodate & incl one no of MCB SP 6 amp, 'B' series, suitable aluminium with bus bar of 3 phase porcelain insulated connectors incl suitable size of lugs & gland for Incoming and outgoing cables, incl taking down old/ unsv box complete all as specified and directed. |
| 38 | M&L for sub main wiring with 1.5 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 20 mm dia, medium grade with all conduit accessories incl cutting / chases etc in stone/ brick masonary/ walls and making good to the disturbed surfaces to match the existing incl taking down old/unsv submain wiring complete all as specified and directed. |
| 39 | S&F sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 4 way, with 200 Amps rated copper bus bar and double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall incl taking down old/unsv DB complete all as specified and directed. |
| 40 | S&F MCB SPN 32 amps, 240 Volts, AC of breaking capacity 10 KA, 'C' curve and connections by using suitable copper lugs complete all as specified & directed. |
| 41 | S&F MCB SP, AC, 240 volts of 06 to 32 Amps capacity \\"B\\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |