| 1 | Material & labour for PCC (1:2:4), type B1 (using 20 mm graded stone aggregate) as in pillar to support the pipe lines including necessary form work and finishing the exposed surfaces of concrete fair and even all as specified and directed |
| 2 | Day to day maintenance of Fire-main system of length of 2610 RM include associated fitting & accessories for the dia of 300mm - 1100 RMtr, 200mm - 320 Rmtrs, 150mm - 520 Rmtrs, 100mm - 550 Rmtrs, 80mm - 120 Rmtrs; Groud Monitoring Valves - 04 Nos, Hydrant Valves - 57 Nos, 300mm Valves - 15 Nos, 250mm Valves - 06 Nos, 200mm Valve - 06 Nos, 150mm Valves - 16 Nos, 100mm Valves - 44 Nos, 80mm Valves - 07 Nos as follows including following:a) Ensure that there is no leak through valve glands & pipe joints in the system, and ensure all hydrants are in working condition includes presssure gauges.b) Check and make all fire-hydrant valves for smooth operation in the systemc) Check and apply greasing for all hydrant & branch valves |
| 3 | d) Ensure proper supporting for enire dock down point and branch lines and main line if not plac the supports by strctural / civil works e) Replace the rubber dsic seal for hydrant valve if leak heavy.f) Inspect and operate the ground monitoring system with foaming ensure working properly with associated valves are works free to operateg) Maintenace of firemain manifold with associated valves and make sure no leakge while operatesh) Inspect the complete internal Main line and related valves are working make open and close fully free operation of valvesi) Clamping & Supports to be verifired and to be repaired if any found damagej) Inspect, Identy and change any dia/ length wornout pipeline as suggested and directed by Engineer In-chargek) Overhauling the firemain manifold with associated valves l) Overhauling the Hydrant valve |
| 4 | Note: Firm to supply and position sufficient lighting, ventilation provision and a 100 TPH submerible pump in the pits/ galleries/ dock points etc. whereas required separetly with all associated panels, discharge pipe to discharge from pump house (minus 20 Mtrs)/ galleries/ dockfloor to sea (Jetty level) so as to ensure that residual water is nill at all points of time. Firm is not to depend on the availability of the pump house equipment and should make its own arrangements for removal of water from galleries/ dockfloor/ pump houses. Any delay in work with regards to presence of leakage of water is attributable to firm. Firm should have its own ararangement of suffiecient tools & jigs, crane and lifting assesories for lift and renewal/ repair/ overhaul of pipelines/ valves and associated parts. If required firm should provide additional capacity pump as standby as suitable to existing fire-main pump pressure. |
| 5 | M & L for painting, clean, chip & paint all the pipes & valves with one coat of anti corrosion primer & two coats of Signal Red paint complete all as specified and as directed. |
| 6 | S & F Ground monitoring manual system with foaming and associated valves of materia Cupro nickle for firefighting range upto 30Mtrs complete all as specified and as directed. |
| 7 | S & F Ductile iron double flanged 90 degree/ 45 degree bends of size 100mm size as per IS9523 complete all as specified and as directed. |
| 8 | S & F Ductile iron double flanged 90 degree/ 45 degree bends of size 150mm size as per IS9523 complete all as specified and as directed. |
| 9 | S & F Gun metal fire hydrant size 80mm (landing valve double point y type ) as per IS 5390 with brass male adaptor.complete all as specified and as directed. |
| 10 | S & F Gun metal fire hydrant size 80mm (landing valve single point ,oblique type) as per IS 5390 with brass male adaptor.complete all as specified and as directed. |
| 11 | S & F Ductile iron T- joint all flanges of 100x100x80mm size as per is:9523 complete all as specified and as directed. |
| 12 | S & F Ductile iron T- joint all flanges of 150x150x100mm size as per is:9523 complete all as specified and as directed. |
| 13 | S & F Rubber gasket 6mm thk, 80mm/100mm dia & 150mm to 300mm dia with shore hardness of BA 70 suitable for pipes/ bends/ tees/reducers/ valves under mentioned dia complete all as specified and as directed. |
| 14 | Supply and fix Staineless steel bolt (SS316) and nut with double washer as follows: |
| 15 | M16X75mm long stainles steel bolts and double washer and nut |
| 16 | M18X90mm long stainles steel bolts and double washer and nut |
| 17 | Supply and fix Ductile iron double flanged K9 distance piece as per IS 8329 |
| 18 | 100mm X1000mm long |
| 19 | 100mm X 500mm long |
| 20 | 100mmX300mm long |
| 21 | Supply and fix Ductile iron double flanged (welded) K9 pipe as per IS 8329 |
| 22 | 100mm x 3000mm long |
| 23 | 100mm x 2000m m long |
| 24 | 150mmx3000mm long |
| 25 | 150mm x 2000mm long |
| 26 | 200mm x 2000mm long |
| 27 | 300mm x 1000mm long |
| 28 | S & F of Ductile iron double flanged Sluice valve of 100mm size as per IS 14846-2000 PN 1.6 with SS-304 grade spindle and SS-304 grade complete all as specified and as directed. |
| 29 | S & F of Ductile iron double flanged Sluice valve of 150mm size as per IS 14846-2000 PN 1.6 with SS-304 grade spindle and SS-304 grade complete all as specified and as directed. |
| 30 | S & F of Duplex steel Grade-4, SS 316, Operating Angle-90 Deg, Design Line Pressure-10kg/cm2, Double flanged raised spindle sluice valve 300mm dia valve, duplex ss complete all as specified and as directed. |
| 31 | S & F of Duplex steel Grade-4, SS 316, Operating Angle-90 Deg, Design Line Pressure-10kg/cm2, Double flanged raised spindle sluice valve 200mm dia valve, duplex ss all as specified and directed. |
| 32 | S & F of 300mm Dismantling joint, DI complete all as specified and as directed. |
| 33 | S & F of 200mm Dismantling joint, DI complete all as specified and as directed. |
| 34 | S & F of 150mm Dismantling joint, DI complete all as specified and as directed. |
| 35 | S & F of Suction SS stainer basket type size of 200mm dia complete all as specified and as directed. |
| 36 | S & F of Expansion below of Stainless Steel (SS316) of 200mm dia complete all as specified and as directed. |
| 37 | S & F of Rubber lined fabric reinforced Fire hose RBL hose pipe type B,100% synthetic yarn, 15Meters length with double end brass coupling working pressure 15Bars complete all as specified and as directed. |
| 38 | M&L for Cross arms,t-joints, F-Rod Tools, SS Stainners, SS Dismantlng joint, expansion bellows, bends, Reducers, distance piece of heavy duty C-Class material of DI, and brasings, supports, clapms and back plates fabricated from structural steel suctions, including nuts and bolts and washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and one under coat and one finishig coat of paint at galleries and under sump pits and pumphouse sumps conncted lines, complete all as specified and directed. Please Enable Macros to View BoQ information |