| 1 | Attending day to day complaints lodge in complaint register or ARMAAN/MES app of interrupted/breakdown of external water supply and repair to make the continuity of external water supply after detecting & rectifying the defect such as replacement of nipple, tee, union, socket or blockage in any pipe from 15mm to size 50 mm and other minor items such as required in order to make good the continuity of water supply to the entire satisfaction of Engineer-in-Charge complete, all as specified & directed, |
| 2 | Attending day to day complaints lodge in complaint register or on ARMAAN/MES app of interrupted/breakdown of external water supply and repair to make the continuity of external water supply after detecting & rectifying the defect such as replacement of nipple, tee,union,socket or blockage in any pipe from 60 mm to 80 mm and other minor items such as required in order to make good the continuity of water supply to the entire satisfaction of Engr in Charge complete all as specified & directed, |
| 3 | Attending day to day complaints lodge in complaint register or on ARMAAN/MES app of interrupted/breakdown of external water supply and repair to make the continuity of external water supply after detecting & rectifying the defect such as replacement of nipple, tee,union,socket or blockage in GI/CI/DI/PPR pipe from 100 mm to 150mm and other minor items such as required in order to make good the continuity of water supply to the entire satisfaction of Engr in Charge complete, all as specified & directed, |
| 4 | Attending day to day complaints for repairing to existing CI/DI/MS pipe line leakage by caulking of lead joint or any other means like fixing a clamp with rubber sheet or filling Lead at the place of leaking joints in running water pipe line including necessary material for 150 to 250 mm CI/DI pipe and fitting such as clamps or any other fittings will be provided by the contractor and its cost is included in the quoted item rate complete as specified and directed. Note : Rates of Lead,rubber sheet clamps etc are paid seprately. |
| 5 | Note (Item No 01 to 04) :- (a) This item pertains to attending complaints of external water supply such as T&P and safety tools will be the responsibility of contractor etc as required in order to attend the complaint to the entire satisfaction of user/Engineer-in-Charge. (b) Rs. 200/- per day will be recovered from payment to contractor(c)if fail to rectify complain within 24 hrs. Necessary exacavation /digging wherever required for the rectification of complaint will be done by the contractor and no extra amount will be paid seperately and bidder are advised to quote the rate in respective items (d) Rap of contractor will report to JE E/M in morning for daily water supply complaints of nasirabad area alongwith status of previous day complaints |
| 6 | Supply only in repair of GI specials 15 to 25mm (Union/Elbow/reducer/Tee/Dead Plug etc) to be fixed in existing / relaying GI tubing for making serviceable of the line complete all as specified and directed. |
| 7 | Supply only in repair of GI specials 32 to 50 mm (Union/Elbow/reducer/Tee/Dead Plug etc) to be fixed in existing / relaying GI tubing for making serviceable of the line complete all as specified and directed. |
| 8 | Supply only in repair of GI specials 80 to 100 mm (Union/Elbow/reducer/Tee/Dead Plug etc) to be fixed in existing / relaying GI tubing for making serviceable of the line complete all as specified and directed. |
| 9 | Supply & fixing in repair gun metal gate valves 20 mm bore with iron wheel head screwed both ends for GI pipe complete all as specified and directed. |
| 10 | Supply & fixing in repair gun metal gate valves 25mm bore with iron wheel head screwed both ends for GI pipe complete all as specified and directed. |
| 11 | Supply & fixing in repair gun metal gate valves 40mm bore with iron wheel head screwed both ends for GI pipe complete all as specified and directed. |
| 12 | Supply & fixing in repair gun metal gate valves 50mm bore with iron wheel head screwed both ends for GI pipe complete all as specified and directed. |
| 13 | Excavation in trenches not exc 1.50 metre wide and not exc 1.50 metre deep in soft/ loose soil for laying of pipe line and getting out complete all as specified and directed. |
| 14 | Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cm all as specified and as directed. |
| 15 | Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point. complete, all as specified & directed, |
| 16 | Refixing, connecting, jointing and testing of old serviceble including cleaning of CI/DI/PPR/GI Pipe with all fittings , laid in trenches/fixing to walls retrieved from item of here-in-before complete including taking down all as specified and as directed of the following sizes :- |
| 17 | 100 mm bore |
| 18 | 80 mm bore |
| 19 | 50 mm bore |
| 20 | 40 mm bore |
| 21 | 25 mm bore |
| 22 | 20 mm bore |
| 23 | Supply laying & testing GI pipe of medium grade laying under tranches including taking down old u/s pipe and connected fittings/ accessories complete all as specified and directed of following size |
| 24 | 100 mm bore |
| 25 | 80 mm bore |
| 26 | 50 mm bore |
| 27 | 40 mm bore |
| 28 | 25 mm bore |
| 29 | 20 mm bore |
| 30 | 15 mm bore |
| 31 | Supplying, laying, connecting, jointing and testing in trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed. Note : DI fitting shall be measured and paid separtely |
| 32 | Supplying, laying, connecting, jointing and testing in trenches 100 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed. Note : DI fitting shall be measured and paid separtely |
| 33 | M/L for CI 'D' joint ( Mechenical Joint ) with rubber rings and Nut , bolts , wasshers complete all as specified and directed for the following sizes :- |
| 34 | 150 mm bore |
| 35 | 100 mm bore |
| 36 | 80 mm bore |
| 37 | Supply & fixing in repair PVC float valve 15/20 mm dia high pressure with polythene float and fly nuts complete screwed for GI pipe and fixed complete all as specified and directed. |
| 38 | Taking out sluice valves from any position and repair, refacing, regrinding, check nut, replacing spindle, stuffing box of sluice valve and make serviceable of size 80 to 300mm bore and reassembling and refixing the same place all as specified and directed. |
| 39 | Material and labour brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 including dismantling of existing brick work complete all as specified and directed. |
| 40 | M&L for run lead joint for 80mm to 100mm bore CI spigot & socket pipe and fittings including preparation of ends & jointing materials, coupling & testing complete all as specified & directed. |
| 41 | M&L for run lead joint for 150mm to 200mm bore CI spigot & socket pipe and fittings including preparation of ends & jointing materials, coupling & testing complete all as specified & directed. |
| 42 | M&L for run lead joint for 250 mm bore CI spigot & socket pipe and fittings including preparation of ends & jointing materials, coupling & testing complete all as specified & directed. |
| 43 | Dewatering from trenches and taking out of mude etc with the help of JCB or mud pump at site and taking out of broken/cracked pipe 80 to 450 mm bore including excavation, returning & filling, removing soil and making good disturbed surface on both side complete, all as specified & directed, |
| 44 | Supplying, laying, connecting, jointing and testing in trenches ductile iron fittings (special castings) (class K12 as per IS 9523: 2000) for ductile iron pressure pipe for water mains upto 450 mm nominal dia (spigot and socket and flange ends (for push on joints and flanged joints) with external coatings of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 9523: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 for push on joints and rubber gasket as per IS 638: 1979 for flanged joints complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 45 | Supplying, laying, connecting, jointing and testing in trenches ductile iron fittings (special castings) (class K12 as per IS 9523: 2000) for ductile iron pressure pipe for water mains upto 450 mm nominal dia (spigot and socket and flange ends (for push on joints and flanged joints) with external coatings of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 9523: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 for push on joints and rubber gasket as per IS 638: 1979 for flanged joints complete all as specified and as directed. Please Enable Macros to View BoQ information |