| 1 | Supply, Installation, Testing and Commissioning of weatherproof 415V with 25 KA/1s short circuit rating TPN double door cubicle type Power Distribution Boards with canopy, made out of 2mm thick CRCA steel with Aluminum busbars with the following components generally as specified in the specification and IE Rules for mounting outdoors.a. 100 A TPN MCCB with electronic overload, short circuit, earth fault and earth leakage release with adjustible settings - 1 No Incomerb. 32 A TPN MCB before Energy meter- 4 Nosc. Three Phase Smart Energy Meter with GPRS connectivity as per specification - 4 nosd. 32A TPN MCB after Energy meter - 4 Nose. 25A SP MCBs - 1 Nosc. LED type R,Y,B indicating lamps with HRC fuses to be connected on line side - 1 setd. Digital multi function meter with facility to indicate all the 3 line voltages, currents, power, energy to be connected on bus side with necessary CTs, fuses, etc -1setNote: Vendor shall be CPRI approved |
| 2 | Supply |
| 3 | Installation |
| 4 | 8 Way IP 43 SPN DB with following components.a. 25 A DP 30mA compact RCBO incomer - 1 Nob. 10A SP MCB - 6 Nos |
| 5 | Supply |
| 6 | Installation |
| 7 | 4 Way IP 43 VTPN DB with following components.a. 32 A FP 30mA RCBO incomer - 1 Nob. 10A SP MCB - 4 Nosc. 16A SP MCB - 8 No |
| 8 | Supply |
| 9 | Installation |
| 10 | Supply and installation of following light fittings with all accessories like supporting hardware, downrods, junction boxes, required frames etc as required to complete the installation in all respects |
| 11 | Supplying and fixing a 2/3/4-module electronic LED foot lamp (240V AC) with front-loading design along with required GI conceal junction box of appropriate size |
| 12 | Supply |
| 13 | Installation |
| 14 | PVC Angle Holder for bulb including connections |
| 15 | Supply |
| 16 | Installation |
| 17 | LED Inverter bulb (Emergency lamp) with light output >= 1200 lumens under normal AC mains operation and approximately 50% lumen output during DC/battery mode , CCT: 4000- 6500K. The unit shall incorporate a built-in overcharge/deep-discharge protected lithium-ion battery mechanism to automatically switch to DC mode during AC mains failure, providing up to 4 hours of continuous illumination |
| 18 | Supply |
| 19 | Installation |
| 20 | Circular surface mounted LED down light fitting with with lumen output>1200lumens, Luminaire efficacy of >100 lm/W, CCT:4000K-6500K, CRI>=80, IP20, power factor>0.9 , surge protection of minimum 2.5 KV, Protection class IEC safety class-1 |
| 21 | Supply |
| 22 | Installation |
| 23 | LED bulb with light output >=1020 lumens, Luminaire efficacy of around >=100 lm/W , CRI>90, CCT-5700K-6500K suitable for operation on 230V, 50Hz AC supply. |
| 24 | Supply |
| 25 | Installation |
| 26 | LED high efficient 4ft batten type light fitting with CRCA housing, with output >2000 Lumens, Luminaire efficacy of around >= 110 lm/W, IP20, surge protection of minimum 4KV, power factor>0.9, CRI>80, CCT-5700K, voltage range 140-270V AC, Protection class IEC-safety class-1, EMI/EMC compliance. |
| 27 | Supply |
| 28 | Installation |
| 29 | LED Floodlight luminaire with light output >= 3000 lumens, Luminaire efficacy of around >=100 lm/W , CRI>80, CCT-5700K-6500K , wide beam angle of approximately 110°, IP65 rated weatherproof suitable for operation on 220-240V, 50Hz AC supply. |
| 30 | Supply |
| 31 | Installation |
| 32 | Supply and fixing of 230V, 1200mm sweep Energy efficient 5 star rated BLDC ceiling fans with 30W power consumption, with dedicated remote controller with required downrods with all required accessories.[Compatible Remote & Remote Holder shall be supplied with Fan]Warranty: 2 Years |
| 33 | Supply |
| 34 | Installation |
| 35 | Square-shaped 200 mm sweep plastic/polymer domestic exhaust fan made of high-quality, anti-rust PP (Polypropylene) or equivalent sturdy plastic materia with air flow capacity >=500 CMH and automatic dust protection shutters/louvers suitable for operation on 230V, 50Hz AC supply. |
| 36 | Supply |
| 37 | Installation |
| 38 | Supply and installation of modular switch boards along with required face plate, concealed GI back box, frame of following sizes with latest model rugged modular type sparkproof switches and shuttered universal sockets. Colour of the switches and sockets/frame shall be Grey/white colour. |
| 39 | 12 modular switchboard with 9 Nos 6A Switches , 1 No of 16A switch and 1 No of 6A socket |
| 40 | Supply |
| 41 | Installation |
| 42 | 8 modular switchboard with 2 Nos 6A Switches and 2 No of 6A socket and 1 No of 1M Co-axial TV outlet and 1M RJ45 Information Outlet suitable for Cat-6 Cable |
| 43 | Supply |
| 44 | Installation |
| 45 | 8 modular switchboard with 4 No 6A switches and 2 Nos of 6A 2 way switches and 1 No of 6A socket |
| 46 | Supply |
| 47 | Installation |
| 48 | 8 modular switchboard with 2 No 6A 2-way switches, 1 no of 16 A switch, 1 no of 6A socket and 3 Nos of 6A switches |
| 49 | Supply |
| 50 | Installation |
| 51 | 6 modular switch board with 1 No of 6/16 A universal Socket and 1 nos of 16A switches and 1 No of 6 A universal Socket and 1 no of 6A switch |
| 52 | Supply |
| 53 | Installation |
| 54 | 6 modular switch board with 4 No of 6 A switches and 1 no of 6A socket |
| 55 | Supply |
| 56 | Installation |
| 57 | 3 modular switch board with 3 No of 6A switches |
| 58 | Supply |
| 59 | Installation |
| 60 | 3 modular switch board with 1 No of 6/16 A universal Socket and 1 nos of 16A switches |
| 61 | Supply |
| 62 | Installation |
| 63 | 3 modular switch board with 1 No of 6 A universal Socket and 1 nos of 6A switches |
| 64 | Supply |
| 65 | Installation |
| 66 | 2 modular switch board with 1 No of 6/16A universal socket |
| 67 | Supply |
| 68 | Installation |
| 69 | 2 modular Electronic Chime Bell suitable for 230V AC supply |
| 70 | Supply |
| 71 | Installation |
| 72 | 2 modular 6A - Bell Push - Single Pole - 1 Way - with Indicator |
| 73 | Supply |
| 74 | Installation |
| 75 | Supply and pulling of following sizes of flexible HFFR copper wires to be drawn in already concealed PVC conduit/channels/external conduit/ DLP trunking with ferruling on both ends excluding cost of pipes, channels and switch boards. |
| 76 | 1.5 Sq.mm Copper wire |
| 77 | Supply |
| 78 | Installation |
| 79 | 2.5 Sq.mm Copper wire |
| 80 | Supply |
| 81 | Installation |
| 82 | 4 Sq.mm Copper wire |
| 83 | Supply |
| 84 | Installation |
| 85 | Supply and laying of following sizes of 1.1 KV grade XLPE insulated, PVC extruded inner sheathed, armoured, FRLS PVC ST2 outersheathed cable on cable trays/trenches/ground with all accessories |
| 86 | 4c 6 Sq.mm Cu cable |
| 87 | Supply |
| 88 | Installation |
| 89 | Supply and laying of following sizes of 1.1 KV grade XLPE insulated, PVC extruded inner sheathed, flexible FRLS PVC ST2 outersheathed cable on cable trays/trenches/ground with all accessories |
| 90 | 3c 2.5 Sq.mm Cu cable |
| 91 | Supply |
| 92 | Installation |
| 93 | Providing end terminations for following sizes of 1.1 KV grade XLPE insulated and PVC sheathed armoured cables with required hard ware like heavy duty double compressor glands, heavy duty long neck copper lugs etc complete |
| 94 | 4c 6 Sq.mm Cu cable |
| 95 | Supply |
| 96 | Installation |
| 97 | 3c 4 Sq.mm Cu cable |
| 98 | Supply |
| 99 | Installation |
| 100 | Supply and installation of following sizes of 2mm thickness hot dipped GI perforated cable trays along with tray cover |
| 101 | 50 mm width, 50mm height |
| 102 | Supply |
| 103 | Installation |
| 104 | 100 mm width, 50mm height |
| 105 | Supply |
| 106 | Installation |
| 107 | Supply and installation of 19 mm dia 1.8 mm thick PVC conduits and required junction boxes confirming to IS in wall /roof slabs, including cutting the wall/chasing and making good the same to the original finish complete |
| 108 | Supply |
| 109 | Installation |
| 110 | Supply and installation of accessories suitable for 19 mm dia PVC conduit |
| 111 | Coupling Bends |
| 112 | Junction Box |
| 113 | Supply and installation of 25 mm dia 1.8 mm thick PVC conduits and required junction boxes confirming to IS in wall /roof slabs, including cutting the wall/chasing and making good the same to the original finish complete |
| 114 | Supply |
| 115 | Installation |
| 116 | Supply and installation of accessories suitable for 25 mm dia PVC conduit |
| 117 | Coupling Bends |
| 118 | Junction Box |
| 119 | Supply and installation of 25 mm dia corrugated flexible conduit pipes |
| 120 | Supply |
| 121 | Installation |
| 122 | Supply and installation of 32 x 20 mm DLP plastic trunking system with required clamps for fixing, cover, end caps etc complete |
| 123 | Supply |
| 124 | Installation |
| 125 | Supply and installation of following accesories for 32 x 20 mm DLP plastic trunking system |
| 126 | End cap |
| 127 | Flat angle |
| 128 | Flat junction / coupling |
| 129 | Supply and fixing of 50 x 6 mm hot dip galvanised GI strip for earthing at a height on cable trays/walls/ground |
| 130 | Supply and fixing of 8 SWG Hot Dipped GI wire |
| 131 | Supply, Installation, Testing & Commissioning of maintenance free earthing system & associated works, etc. complete as per specifications & instructions of E-I-C. A. Providing an earth station using 25 mm dia 3M long earthing electrode of high tensile low carbon steel rod molecularly bonded 250 micron copper coating on the outer surface, fillingthe bore with suitable environment friendly earth enhancement compound as per manufacturer's standard surrounding the earth electrode complete with all required materials & as per the instructions of EIC. All the components shall comply to IEC-62561, IS 3043, IS 2309 as applicable.Note: The scope includes :- 1) Installation of earth rods including making pit/ drilling suitable size bore holes in normal soil/ hard rock as per manufacturer's recommendations & design. Bore hole shall be made using machine only.2) Interconnection of earth electrodes along with required SS double sided universal clamps with GI strip. 50 x 6 mm & 150 mm long GI equipotential bar also shall be mounted insidechamber as per instructions of EIC. B. Providing & making concrete chamber (1:2:4) of size 600 x 600 x 600 mm (inside dimension) with 10 mm thick MS hinged cover mounted on 40 x 40 x 5 mm thick angle iron frame, 50 x 6 mm & 150 mm long GI equipotential bar mounted inside chamber as per instructions of EIC. Note: The Earth pit marker of 250mmX200mmX4mm MS sheet shall be welded to an 25mmX25mmX3mm angle of 300mm long shall be fixed on a concrete block. The marker shall be painted with black paint base and values written in yellow paint. Suitable test certificates from accredited labs to be submitted for approval |
| 132 | Supply |
| 133 | Installation |
| 134 | Suply and installation of structural steel like channels, angles etc for fabriaction and erection of, cable trays supports, light fitting supports etc and painting of the same with red oxide and 2 coats of grey enamel paint. Rate should also include the required bolts and nuts for fixing of supports |
| 135 | Supply |
| 136 | Installation |
| 137 | Supply and fixing of 100 mm X 25 mm anodised Aluminium cable tags engraved on black back ground with name of the load along with required hardware for fixing the lables on to the cables. |
| 138 | Dismantling brick work or stone work made out of lime or cement mortar including stacking of materials and making good the surface as directed by Engineer-in-charge |
| 139 | Removal of existing Power Distribution boards of approx dimension 2000 X 1000 mm mounted on stand. The removed material should be shifted to an identified location about 500m away. |
| 140 | Removal of existing MCB Distribution boards of approx dimension 600 X 300mm mounted on the wall/concelaed in the walls and making good of the surface. The removed material should be shifted to an identified location about 500m away. |
| 141 | Removal of cables of about 6 Sq.mm to 2.5 sq.mm sizes and making good of the surface. The removed material should be cut to 1m lengths and shifted to an identified location about 500m away. |
| 142 | Removal of MS/PVC lighting Switchboards/ sockets and making good of the surface. The removed material should be shifted to an identified location about 500m away |
| 143 | Removal of light fitting along with their down rods and other accessories and making good of the surface. The removed material should be shifted to an identified location about 500m away. |
| 144 | Removal of ceiling fans / exhaust fans along with their down rods and other accessories and making good of the surface. The removed material should be shifted to an identified location about 500m away. |
| 145 | Removal of flexible wires of sizes 1.5 sqmm to 4 sqmm in concealed conuits/surface conduits/trunking and making good the surface. The removed material should be shifted to an identified location about 500m away as per directions of Engineer-in-charge Please Enable Macros to View BoQ information |