| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. Hard Rock (Blasting Prohibited). |
| 2 | Dismantling steel work manually/by mechanical means in built up sections without dismembering and stacking within 50 meters lead as per direction of Engineer-in-charge. |
| 3 | Dismantling roofing including ridges, hips valleys and gutters etc., and stacking the material within 50 meters lead. (a) G.S. Sheet. |
| 4 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded. |
| 5 | Providing and fixing grouted bar 25mm dia upto 3m long. |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for: Arches, domes, vaults upto 6 m span. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for: Extra for arches, domes, vaults exceeding 6 m span. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for:Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 12 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve orkability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. All works above plinth level upto floor V level. |
| 13 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 14 | Cement variation. |
| 15 | Drilling of holes having Diametre 45mm and length upto 3m. For contact grouting. |
| 16 | Providing and fixing Poly propylene- Random - Co - Polymer (PPR) pipes PN-16 (SDR 7.4) - 50 mm Outer dia. |
| 17 | Providing and fixing Rock anchor / Rockbolts (Resin & cement grouted) 25 mm dia with bearing plate, Nut & washer upto 3.00m long. |
| 18 | Grouting Operations for contact grouting. |
| 19 | Supply , Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,splitter sampers,vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick . |
| 20 | Supply , Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows,splitter sampers,vanes,hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.80 mm thick. |
| 21 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. |
| 22 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 23 | Supply of Materials for support of item number (1 to 4) i.e. Fastner, washer, nut etc |
| 24 | Buyback of old scrap after Dismantaling of duct ( GSS sheet,MS angles, nut , bolt , washer etc.) approx |
| 25 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. size 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 26 | Providing and fixing circular/hexagonal cast iron box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamps shall be made of 12mm dia M.S. bar bent to shape as per standard drawing |
| 27 | Supplying and fixing of 20mmsizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 28 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. size 2X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 29 | Supplying and fixing 6 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) |
| 30 | Supply, Installation, testing and commissioning of pre-wired, 150W, 120lumen/Watt led HIGHBAY LIGHT , complete with all accessories including installation bracket etc. and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required (make: Orient, Bajaj, Havells, Phillips, CG or as directed by EIC) Please Enable Macros to View BoQ information |