| 1 | Cleaning and blocked sewage line of any dia by rodding etc and removing sludge and making functional the sewage line throught manually/ mechanically(Honey sucker machine) complete all as directed by Engr In-Charge. |
| 2 | Cleaning of night soil from manholes of any size and burried the night soil in the ground not exc 50 mtr distance complete all as directed. |
| 3 | Providing and fixing unplasticised rigid PVC pipes Type-A, incl jointing with seal ring, single socketed pipes of 110mm dia, laid in trenches in all complete. |
| 4 | Providing and fixing unplasticised rigid PVC pipes Type-A, incl jointing with seal ring, single socketed pipes of 150mm dia |
| 5 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.Rectangular shape 600x450 mm internal dimension |
| 6 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 7 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps ,100 mm diameter |
| 8 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design,100 mm diameter S.W. pipe |
| 9 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete,For pipes 250 to 300 mm diameter |
| 10 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes 150mm dia 10 feet long jointing with seal ring leaving 10mm gap for thermal expansion single socketed pipes of 150mm dia |
| 11 | Providing and fixing on wall face unplasticised PVC shoe bend 150mm for unplasticised rigid PVC rain water pipes Type-A, incl jointing with seal ring leaving 10mm gap for thermal expansion. |
| 12 | Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coars sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 20 mm dia, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (ISI Marked) |
| 14 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes .-ditto- but External work :25 mm nominal dia Pipes |
| 15 | Providing and fixing CPVC gate valve 20mm dia |
| 16 | Providing and fixing CPVC gate valve 25mm dia |
| 17 | Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 :15 mm nominal bore |
| 18 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931,15mm nominal bore |
| 19 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia |
| 20 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length |
| 21 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 22 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore |
| 23 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore Please Enable Macros to View BoQ information |