| 1 | Construction of Tube Well from ground level and upto 100 mtr. Depth to accommodate housing and assembly pipe in all type of alluvium strata, unconsolidated formation such as pebbles, boulders etc. By percussion/ rotary drilling method as per IS: 2800 (part 1;1991 & IS: 2800 Part 2;1979) as amended up to date and technical specification, with gravel as per IS;4097-1967 and its packing as per IS;2800 (part1&ll)1979 as amended upto date( the work included the cost of gravel& its prlmary packing and pcking during development. The work will include cost of lowering of housing& strainer assembly pipes, with supply and wrapping of coir rope, wherever necessary for arresting fine sand particles and development of tube well as per IS specification using suitable Air Compressor but will not include cost of casing & strainer pipe. Work will be completed after obtaining sand free water. |
| 2 | Nominal Bore 200 mm Dia |
| 3 | Construction of tube well after completion of drilling by rotary /percussion method & up to 100 mtr. depth in all type of rocks by DTH system as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work shall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. |
| 4 | Nominal Bore 200 mm Dia |
| 5 | Add 15% extra on above item for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. |
| 6 | Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-I) 1991 with latest amendment. |
| 7 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of grade Fe 410 of following sizes :-200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) |
| 8 | Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. |
| 9 | 200 mm dia nominal bore |
| 10 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5 mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both end in 80mm sizes passing through a hole in the centre of MS sheet. A 25mm socket with end plug shall also be welded over top plate (as per drawillg enclosed). A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall tie provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. |
| 11 | 200 mm dia |
| 12 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. |
| 13 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. |
| 14 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. |
| 15 | 50 mm dia |
| 16 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully utomatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). All these quipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 5x35x5mm) duly olted/screwed with enclosure box having 4 legs, each leg's length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC lateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. |
| 17 | Above 5 HP to 10 HP |
| 18 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. |
| 19 | 10.0 Sq.mm, 4 core |
| 20 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694: 1990 or amended up to date and conductor as per class 5 of IS 8130: 1980 including making connection etc. |
| 21 | 3 core 4 mm square |
| 22 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. |
| 23 | Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia complete in all respect. |
| 24 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. |
| 25 | Pipe Line Work |
| 26 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M.HDPE PE-80 PN-6 |
| 27 | 63 mm dia |
| 28 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil |
| 29 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering |
| 30 | M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). |
| 31 | P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. |
| 32 | 32mm dia nominal bore |
| 33 | 'A' Class |
| 34 | P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : |
| 35 | (-do-) 32mm nominal bore. |
| 36 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. |
| 37 | MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) |
| 38 | Providing, lowering, laying, aligning, fixing in position at all level/ depths CI Class - B specials as per IS : 1538, amended up to date in trenches complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. |
| 39 | Plain ended CI specials including tail piece, spigot end and socket end. |
| 40 | Up to 300 mm dia |
| 41 | Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size. |
| 42 | Welded mesh 50 mmx 50 mm x 2.1 mm Please Enable Macros to View BoQ information |