| 1 | Dismantling clearing away and carefully stacking materials useful for reuse for any thickness of walls of laterite in cement mortar including disposal of debris within a distance of 1.50meter. |
| 2 | Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 4 | Providing and laying in position cement concrete specified grade excluding the cost of centering, shuttering - All work up to plinth level 1:4: 8 (1cement :4 coarse sand (zone-III)drived from natural sources :8 graded stone aggregate 40mm nominal size derived from natural sources) |
| 5 | Random rubble masonry iusing department rubble,in cement mortar 1:6(1 cemetn:6 coarse sand) with hard stone for foundation and basement up to plinth level. |
| 6 | Random rubble masonry in cement mortar 1:6(1 cemetn:6 coarse sand) with hard stone for foundation and basement up to plinth level. |
| 7 | Centering and shuttering including strutting, etc. and removal of form for:foundation, footings, bases of columns,e tc for mass concrete. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 (1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size derived from natural sources). |
| 9 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size derived from natural sources) |
| 11 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete |
| 12 | Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement:3 coarse sand (zone-III) derived from natural sources:6 graded stone aggregate 20mm nominal size derived from natural sources) |
| 13 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform. |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 15 | 12mm cement plaster of mix 1:4 (1 cement:4 fine sand). |
| 16 | 6mm cement plaster of mix 1:3 (1 cement:3 fine sand). |
| 17 | Finishing walls with Acrylic smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 18 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings , frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. Please Enable Macros to View BoQ information |