| 1 | Providing skilled and unskilled staff for operation and routine maintenance of electrical and mechanical installations at Arya Bhatt Polytechnic as per the inventory and as per direction of Engineer-in-charge & as per the terms and conditions for the following works:-a) Operation and routine maintenance of Electrical Installations (Internal & External), Operation of RO plant, Operation of Sub-station and DG Set. Operation of water supply pump set and fire fighting etc. i) Wireman cum Operator - 04 Nos. (One in each shift (6 AM to 2 PM, 2 PM to 10 PM & 10 PM to 6 AM) and 1 No. in General shift (9 AM to 5 PM))ii) Khallasi - 02 Nos. (9 AM to 5 PM & 10 PM to 6 AM) |
| 2 | Comprehensive, running maintenance & day to day servicing of following capacity Window / Split AC and water cooler installed under Sub-Division-I i/c replacement all defective i.e. blower motor, compressor, Gas Charging, PCB, remote, Plug Top, Starting Capacitor, Running Capacitor, Starting Relay, Thermostat, Propeller Fan, Over load Relay i/c condenser unit, evaporative unit charging of refrigerant gas in case of leakage i/c refrigerant gas pipe with insulation, lead wire, plug Top, etc complete as per terms and conditions attached:-a) Window type AC/ Split type AC of 1.5TR/2.0 TR capacity. (43 Nos. for 8 Months- 344 Jobs) |
| 3 | b) Water coolers of capacities 100/150 ltr (10 Nos. for 12 Months-120 Jobs) |
| 4 | Supplying & fixing of following electrical accessories suitable for existing different type fitting/switch box i/c testing etc. as required. (Labour already included in Item No. 1)5/6 A switch (Modular type) |
| 5 | 15/16 A switch (Modular type) |
| 6 | 3 pin 5/6 A socket outlet (Modular type) |
| 7 | 6 pin 15/16 A socket outlet (Modular type) |
| 8 | Stepped type Modular Fan regulator (2 module) |
| 9 | 5/6 A switch (Piano Type) |
| 10 | 15/16 A switch (Piano type) |
| 11 | 3 pin 5/6 A socket outlet (Piano type) |
| 12 | 6 pin 15/16 A socket outlet (Piano type) |
| 13 | 1 or 2 Module Cover plate |
| 14 | 3 Module Cover plate |
| 15 | 6 Module Cover plate |
| 16 | 8 Module Cover plate |
| 17 | 12 Module Cover plate |
| 18 | 1200mm ceiling fan, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 19 | 150 Watt. LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt). |
| 20 | 300 mm sweep 900 rpm heavy duty exhaust fan |
| 21 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 22 | 3 x 4 sq. mm |
| 23 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A, 16 KA,TPMCCB |
| 24 | 150 A, 16 KA,TPMCCB |
| 25 | 250 A,36KA,FPMCCB |
| 26 | Supplying & lowering of 2.2KW/3 HP submersible pump set capable of delivering 175-35 LPM at a head of 39-73 mtrs for operation on 415 volts, 3 phase, 50 Hz, AC supply, in the existing borewell with the help of chain pulley and tripod stand i/c providing gasket, GI nut and bolts in the pipe line complete with testing etc. as required. |
| 27 | Supplying & lowering of 5 HP Open well submersible pump set capable of delivering 258-60 LPM at a head of 20-34 mtrs for operation on 415 volts, 3 phase, 50 Hz, AC supply, in the existing open well with the help of chain pulley and tripod stand i/c providing gasket, GI nut and bolts in the pipe line complete with testing etc. as required. |
| 28 | Supplying and installation of 5 HP DOL starter (with wideband coil) submersible pump controllar in sheet steel enclosure suitable for operation on 415 +/- 10% volts 3 Phase 50 +/- 5% HZ AC supply, overload relay, current rating from 6-10 Amp, single phase preventor, Ampere meter, Voltmeter i/c connections with copper conductor cable glands/lugs etc testing and commissioning as required. |
| 29 | Supplying and installation of 7.5 HP DOL starter (with wideband coil) submersible pump controllar in sheet steel enclosure suitable for operation on 415 +/- 10% volts 3 Phase 50 +/- 5% HZ AC supply, overload relay, current rating from 13-22 Amp, single phase preventor, Ampere meter, Voltmeter i/c connections with copper conductor cable glands/lugs etc testing and commissioning as required. |
| 30 | Lifting of existing submersible bore well / open well 3 HP to 10 HP capacity Pump set from the bore well with the help of chain pulley block & tripod stand i/c cartage charge at site from the work shop. |
| 31 | Lowering of 3 HP to 10 HP capacity bore well/open well pumpset in the bore well with the help of chain pulley block and tripod stand i/c cartage charge pump set from work shop to site. |
| 32 | Servicing and Overhauling of 3/5 HP 3 Phase Motor Pump set i/c varnising ,greasing , oiling and making Coupling alignment i/c replacement of bearing etc and re-installation the same, testing and commissioning etc complete as reqd. |
| 33 | Rewinding of 5HP capacity 3 phase multi-stage submersible / mono-submersible pump-set with suitable size water proof copper conductor wire i/c brazing metalling turning & polishing of shaft, replacement of GM bearing bush, thrust bush, thrust plate, necessary sleeves, pads etc. i/c buy back of dismantled material and making connection, testing and commissioning etc. complete as reqd. |
| 34 | Supply & fixing of 3 Core 6.0 sq.mm. flat water proof copper conductor submersible cable i/c connections etc. as required. |
| 35 | Routine maintenance of Kirloskar make 125 KVA DG set with all accessories, complete electrical system, Alternator. AMF Panel including checking and repairing of faults, cleaning etc as per terms and conditions attached. |
| 36 | Supply of following items for Servicing of 01 No. 125 KVA DG set (Kirloskar make) as and when required. i/c dismantling of old material & credit of old dismantle etc complete as required. Oil Filter spinon 1 liter |
| 37 | Fuel Filter 1 liter |
| 38 | Safety Air Filter Element |
| 39 | Primary Filter Element |
| 40 | Premixed Coolant 5 ltr |
| 41 | Petronas Urania 1000 CH-4 10 L |
| 42 | Petronas Urania 1000 CH-4 20 L |
| 43 | Exide Battery 150 AH |
| 44 | 12 volt static battery charger |
| 45 | Under voltage relay 415 VAC |
| 46 | Less credit for dismantle material recevied from the work.5/6A distorted switch (Modular/Piano type) |
| 47 | 15/16A distorted switch (Modular/Piano type) |
| 48 | 5/6A distorted Socket (Modular/Piano type) |
| 49 | 15/16A distorted socket (Modular/Piano type) |
| 50 | Fan Regulator (Modular/Piano type) |
| 51 | 1/2/3/6/8/12 modular damaged cover plate |
| 52 | 40/63/100 TP/FP MCB disorted/damaged |
| 53 | Assorted size Copper wire |
| 54 | 300 mm damaged exhaust fan |
| 55 | 1200 mm damaged ceiling fan |
| 56 | 3/5 HP submersible Pump |
| 57 | 3/5HP Pump Starter Please Enable Macros to View BoQ information |