| 1 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : bituminous road |
| 2 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. The Contractor has detect defferent utilities like sewer line, water supply line electric cable, Telephone cable, Gas pipe line etc, using utility detecting machine before start of excavation and shall start excavation only after getting prior permission of E/I. All kinds of soil. |
| 5 | M-150 Brick Work in 1:4 cement & Coarse sand 2.20 F.M. mortar in foundation and plinth including supply of all materials, labour and T&P etc. requried for proper completion of the work. Same as item no. 305 but in 1:4 one cement & four Coarse sand of 2.20 F.M. mortar. |
| 6 | Repairing of Existing PVC water line including bailing out of water by / Manually / Diesel Engine, P/F PVC coupler, CID joint etc. complete work as per direction of E/I (But Excluding cost of Excavation filling and PVC pipe) 300 mm dia |
| 7 | 400 mm dia |
| 8 | 500 mm dia |
| 9 | Repairing of Existing PVC water line including bailing out of water by / Manually / Diesel Engine, P/F PVC coupler, CID joint etc. complete work as per direction of E/I (But Excluding cost of Excavation filling and PVC pipe)-a) 90 mm dia |
| 10 | 110 mm dia |
| 11 | 140 mm dia |
| 12 | 160 mm dia |
| 13 | 200 mm dia |
| 14 | 250 mm dia |
| 15 | P/F M.S. specials such as Tee , Bends , Collars , Tapers, Gap pieces,including Flange Ends as required , Painting ,Cutting, welding as per site requirement of MS pipe thickness etc complete in all respect as per direction of E/I. |
| 16 | Repairing of sluice valve with the change of spendle (i.e.S.S. non megnated) flapper adjusting nut & bolts & rod & welding machining of body for fitting the flapper properly complete as per direction of E/I. A) 150 mm dia |
| 17 | 200 mm dia |
| 18 | 250 mm dia |
| 19 | 300 mm dia |
| 20 | 400 mm dia |
| 21 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 22 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size) |
| 23 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as perdirection of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level. |
| 24 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 100 |
| 25 | Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 100 |
| 26 | Providing & Fixing CID Joints complete with Rubber rings and Nut-Bolts including all taxes & Contractor profit etc. complete as per direction of E/I a) 100 mm dia |
| 27 | 150 mm dia |
| 28 | 200 mm dia |
| 29 | 250 mm dia |
| 30 | 300 mm dia |
| 31 | 400 mm dia |
| 32 | 600 mm dia Please Enable Macros to View BoQ information |