| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Felling trees of girth(measured at a height of 1. m. Above ground level) inluding cutting of trunks and branches removing the roots stacking the serviceable material and disposal of unserviceable material for all leads :Beyond 30 cm and upto 60 cm grith |
| 3 | Felling trees of girth(measured at a height of 1. m. Above ground level) inluding cutting of trunks and branches removing the roots stacking the serviceable material and disposal of unserviceable material for all leads : Beyond 60 cm and upto 120 cm girth |
| 4 | Felling trees of girth(measured at a height of 1. m. Above ground level) inluding cutting of trunks and branches removing the roots stacking the serviceable material and disposal of unserviceable material for all leads : Beyond 120 cm and upto 240 cm girth |
| 5 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan )for all leads & lifts in all types of strata comprising of any type of materials either in full or part as the case may be adopting any method/methods as may be convenient as permitted (excluding blasting) in all conditions such as dry, moist, foul, saturated, submerged etc. including dressing of sides, planking and strutting, timbering, ramming of bottom, pumping and bailing out water, barricading, danger lighting, guarding and carting away excess excavated earth at the site identified by the contractor and obtaining all statuatory approvals, as directed by engineer for all lead and all lifts etc complete. |
| 6 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation/pipeline trenches drains for all leads & lifts in all types of strata comprising of any type of material either in full or part as the case may be adapting any method/methods as may be convenient as permitted (excluding blasting) in all conditions such as dry, moist, foul, saturated, submerged etc. including dressing of sides, planking and strutting, timbering, ramming of bottom, pumping and bailing out water, barricading, danger lighting, guarding and carting away excess excavated earth at the site indentified by the contractor and obtaining all statuatary approvals, as directed by engineer for all lead and all lifts etc complete. |
| 7 | Refilling the pipeline/foundation trenches, plinth sides, foundation, etc. with available excavated earth in layers not exceeding 20cm in depth consolidating each layer by ramming and watering lead upto 50m and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 8 | Supplying and filling in plinth under floors, trenches including watering, ramming, consolidating and dressing complete with moorum |
| 9 | Supplying and filling approved earth / hard soil obtained from contractor's identified source inclusive of obtaining all requisites statuatory approvals & observing all the security measures, with all lead and lifts, transporting to site, spreading, grading the earth/hard soil in layers not exceeding 250 mm loose layers, breaking clods & compacting including watering each layer to bring it upto to optimum moisture content to attain dry field density not less than 95% of maximum dry density (Procter Test). (Refer detailed specifications enclosed. The cost of the tests, determination of settlement of natural ground by approved method and cost towards obtaining statutory approvals for cutting/borrowing the earth shall be borne by the contractor) |
| 10 | Disposal of surplus earth & debris upto all leads including loading, unloading and stacking, The site should be identified by the contractor and obtain all statuatory approval. |
| 11 | Providing and laying autoclaved aerated concrete (AAC) blocks masonry with 100mm/ 115mm/ 125mm thick with Grade-I AAC blocks of density confirming to IS:2185 (Parts-3) in super structure above plinth level up to floor V with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer-in-charge. (The payment of RCC band and reinforcement shall be made for seperately) |
| 12 | Providing and laying autoclaved aerated concrete (AAC) blocks masonry with 150mm/ 200mm/ 230mm/ 300mm thick with Grade-I AAC blocks of density confirming to IS:2185 (Parts-3) in super structure above plinth level up to floor V with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer-in-charge. (The payment of RCC band and reinforcement shall be made for seperately) |
| 13 | Providing & laying rubble packing with hard laterite stone under floors including watering ramming and consolidating etc.in pipeline trenches and other foundations complete. |
| 14 | Laying of available hard laterite stone soling under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 15 | Providing & constructing laterite masonary in neatly dressed stones of size as specified in Cement mortar 1:5 (1cement : 5 coarse sand) in foundation and basement. |
| 16 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 3 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in matching cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment matching the stone shade : Exposed decorative Patradevi laterite stone - Exposed face machine cut and table rubbed with rough backing - 30 mm thick |
| 17 | Providing & constructing laterite masonary in neatly dressed stones for 23 cms masonary walls in cm. 1:5 (1 cement : 5 coarse sand) in foundation upto plinth level. |
| 18 | Providing & constructing laterite masonary in neatly dressed stones for 23 cms masonary walls in c.m 1:4 (1 cement : 4 coarse sand) in super structure from floor I upto floor V level. |
| 19 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering, shuttering and finishing : In retaining walls , return walls(any thk) including attached ilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc, upto floor five level. |
| 20 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in - all works upto plinth level |
| 21 | Providing and laying upto floor V level cement concrete 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded granitic or basaltic stone aggregate 20 mm nominal size) including centering and shuttering etc. - a) Kerbs, Steps and the like at or near ground level |
| 22 | Providing and laying upto floor V level cement concrete 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded granitic or basaltic stone aggregate 20 mm nominal size) including centering and shuttering etb) String Courses, copings, bed plates, anchor blocks, plain window sills and the like |
| 23 | Providing and laying upto floor V level cement concrete 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded granitic or basaltic stone aggregate 20 mm nominal size) including centering and shuttering et c) Small lintels not exceeding 1.5 m clear span including coping and the like requiring formwork to the suspended portions |
| 24 | Centering and shuttering including strutting, propping etc. and removal of forms for a) foundation, footings, bases of columns etc. |
| 25 | Centering and shuttering including strutting, propping etc. and removal of forms for b) Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like |
| 26 | Centering and shuttering including strutting, propping etc. and removal of forms for c) Columns, Piers, Pillars, Abutments, Posts and struts (square, rectangle polygon in plan) at all levels |
| 27 | Centering and shuttering including strutting, propping etc. and removal of forms for d) Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth at all levels |
| 28 | Centering and shuttering including strutting, propping etc. and removal of forms for e) Staircases (Except Spiral Staircases) excluding landings |
| 29 | Centering and shuttering including strutting, propping etc. and removal of forms for f) suspended floors, roofs, landings, shelves and their supports, balconies and chajjas at all levels |
| 30 | Centering and shuttering including strutting, propping etc. and removal of forms for g) Vertical or horizontal fins individually or forming box, louvers or projected bands at all levels |
| 31 | Extra to be added for additional height in centering, shuttering where ever required with centering, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and de-centering at all levels, over a height of 3.5m, for every additional height of 1m or part thereof. (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (plan area to be measured) |
| 32 | Providing TMT steel reinforcement bars of SAIL, TATA. VIZAG, JSW make only (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 33 | Providing and laying in position machine batched concrete (BMC), machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing the strength and durability as per the direction of the Engineer. M35 grade of reinforced cement conrete by using 428 kg of cement per cu.m. of concrete. All works at all floor levels. NOTE:- 1.Use of RMC is permitted at no extra cost. 2.Only digital weigh batcher to be used in case of batching at site. |
| 34 | Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. - Size 60 cm L x45 cm H x 15 cm T |
| 35 | Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. - a) Size 900 x 400 x150 mm with steel reinforcement not less than 7.0 kg per unit - 30T Capacity |
| 36 | Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. - b) Size 750 x 400 x100 mm with steel reinforcement not less than 4.2 kg per unit |
| 37 | Providing and fixing wood work in frames of doors, windows, clerestory windows, trusses & other frames wrought framed and fixed in position - Second class Indian Teak wood as per drawing |
| 38 | Providing and fixing 35 mm thick panelled glazed or panelled and glazed shutters for doors, windows and clerestory window including anodized aluminium butt hinges with necessary screws - Second class Indian teak wood |
| 39 | Extra for providing vision panel not exceeding 0.1 sq.m. in all types of flush doors (cost of glass minimum 3mm thick to be included). Rectangular or square Unit: SQ.M. door area |
| 40 | Providing and fixing second class Indian Teak wood moulded beading to door and window frames with iron screws, plugs etc. - 50 x 12 mm |
| 41 | Providing and fixing MS grill of required pattern in wooden frames of windows, masonry etc with MS flats, square or round bars with round headed bolts and nuts or by screws - Plain grill |
| 42 | Extra for Providing bright finished stainless steel parliamentary hinges 100x100x27mmx5mm with necessary screws etc complete instead of providing Stainless steel Butt Hinges 100x60x2.5 (Only difference in rate to be quoted) |
| 43 | Providing and fixing SS 304 Aldrop/ sliding door bolts with bolts, nuts and screws etc complete - 250 x 16 mm |
| 44 | Providing and fixing SS 304 Tower bolts (Barrel type) with necessary screws etc complete - 250x10 mm |
| 45 | Providing and fixing SS 304 Tower bolts (Barrel type) with necessary screws etc complete - 100x10 mm |
| 46 | Providing and fixing bright finished SS 304 handles with necessary screws etc complete - 125mm |
| 47 | Providing and fixing bright finished SS 304 door latch with necessary screws etc complete - 250 x 16 x 5 mm |
| 48 | Providing & fixing bright finished C. P. Brass/brass 100 mm. rim latch & lock & a pair of knob, with necessary screws etc. complete (Indian make of approved quality). |
| 49 | Providing and fixing 150 mm. SS 304 floor door stopper with rubber cushion screws etc. to suit shutter thickness complete. |
| 50 | Providing and fixing C. P. Brass/brass hydraulic door closer of approved make with necessary screws and fittings complete. |
| 51 | Providing & fixing Stainless Steel Cylindrical lock 60mm dia with pair of knob, keys etc. with necessary screws etc. for doors complete as approved by engineer. Entrance Function: Internal Push Button & External Key Operation |
| 52 | Providing & fixing Stainless Steel tubular lever D-Type mortise handles with round/Square nose, 24mm Mortise/sash lock body & Strike plate (all SS Finish), Pin cylinder 60mm with one side key and other side knob/thumb turn with necessary screws etc. complete |
| 53 | Providing and fixing Stainless steel D type handles with necessary screws etc complete a) L 300mm/325mm x 22 to 25mm dia |
| 54 | Providing and fixing 1.00mm high pressure decorative Laminates (glossy/ matt) on wooden surfaces like doors, windows. The laminate should comprise of layers of specially selected paper, impregnated with melamine and phenolic resins pressed and hardened under heat and high pressure and should ensure strong bonding, resistance to boiling water and chemical and increase dimensional stablilty. Including cost of adhesive, nails during fixing etc. complete |
| 55 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type (BWP), core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. - 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 56 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type (BWP), core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters - 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 57 | Steel work welded (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of red lead paint. - In R. S. Joist |
| 58 | Steel work welded (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of red lead paint. - In Tees, angles, flats and channels |
| 59 | Supplying and fixing rolling shutters of approved make, made of 80 x 1.25 mm G.M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and G.M.S. top cover of 1.25mm thick for folling shutterstop cover and spring. |
| 60 | Providing and fixing Ball bearings for rolling shutters |
| 61 | Extra for providing mechanical device, chain and crank operation for operating rolling shutters. a)Exceeding 16.80 sq.m. in area Chain & overhead operation |
| 62 | Providing and Fixing M. S. round holding down bolts with nuts and washer plates complete. |
| 63 | Providing & fixing bolts with nuts & washer complete. (Hi Tensile black bolts & nuts as per approved make) |
| 64 | Providing & fixing Anodised Aluminium shutters in accordance with the specifications annexed with Goa schedule of rates (2004) Vol I & II including all taxes, transportation, scaffolding and handling etc Complete as per direction of the engineer : Windows with two sliding shutters using 18mm series shutters sections with plain glass including powder coating with pure polyester of required shade and colour. All work between civil work and aluminium frames shall be sealed and made watertight by applying silicone sealant. 4 mm thk clear float glass, EPDM gaskets complete with accessories for locking, handles, stoppers, ball bearing etc. |
| 65 | Providing & fixing Anodised Aluminium shutters in accordance with the specifications annexed with Goa schedule of rates (2004) Vol I & II including all taxes, transportation, scaffolding and handling etc Complete as per direction of the engineer : Windows with three sliding shutters using 18mm series shutters sections with plain glass including powder coating with pure polyester of required shade and colour. All work between civil work and aluminium frames shall be sealed and made watertight by applying silicone sealant. 4 mm thk clear float glass, EPDM gaskets complete with accessories for locking, handles, stopppers, ball bearing etc. |
| 66 | Providing and fixing Anodized Aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer : adjustable louvred windows (louvre blades of thickness 1.20mm) with figured glass including powder coating with pure polyester of required shade and colour. All work between civil work and aluminium frames shall be sealed and made watertight by applying silicone sealant. 4 mm thk figured glass, EPDM gaskets complete with accessories for locking, handles, stopppers etc. |
| 67 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of approved make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 68 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.with hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 69 | Supply and installation of Aluminium Louvers. The frame should be made of Aluminium tubes of size 100x50X1.50 mm thk and 50X25x1.50 mm thk C channels. Aluminium Z shaped louvers of 100mm should be fixed to the supporting frame with aluminium cleats, GI screws, etc complete. The whole assembly is powder coated with pure polyester paint. (MS framing to be paid separately) |
| 70 | Designing, Fabricating, Supplying and fixing of structural glazing (SEMI UNITISED SYSTEM) by using JINDAL or Equivalent Extruded Aluminium Sections as following, 22739 of size 131 X 38.5 X 2 mm as outer, 22843 of size 131 X 67 X 2 mm mullion & transom, 22841 of size 66.8 X 28 x 1.6 mm as sub frame. The Glazing will be SINGLE GLAZED UNIT Comprising 6 mm toughened ST 167 Glass of Saint Gobain / Equivalent make having properties as visible Light transmittance (VLT) of 65 to 69 %, Light reflection internal 15 to 20%, light reflection external 10 to 20%, shading coefficient (0.75- 0.82) and U value of 5.0 to 6.3W/m2 degree K etc. complete with transoms and mullions spaced appropriately to form grids, spacer tapes and Dow/ Wacker brand structural and weather sealants at site stuck to the Aluminium profile Surface using spacer tape, a structural bite of 15 mm is given in between glass panes and aluminium frames which is filled with Structural Silicone and finished with backer rod and weather sealant for water resistance. Aluminium members shall be Powder coated (PVDF) to minimum thickness of 50 microns as in colour as instructed by Engineer in Charge. |
| 71 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer (Door handle, lock and stopper etc.to be paid separately) |
| 72 | Providing and fixing special quality SS 304 Centre patch lock with cylinder for 12mm frameless toughened glass door shutter. The lock should have locking arrangements with keys on both side with necessary screws etc complete |
| 73 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). |
| 74 | Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastner of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 m dia polyamide PA6 grade sleeve, including drilling of hole in frame, concrete/ masonry, etc. as per direction of Engineer. - 10 x 120mm |
| 75 | Ultra-high strength, high-precision, dual shrinkage compensated, free flow cementitious grout for machine , column base platesProviding and Supplying Masterflow 928T of BASF make or equivalent approved which is dual shrinkage-compensated, cementitious grout shall be hydraulic-cement based free-flow, high strength grout that complies with ASTM C1107. The grout shall have compressive strength minimum of 35 MPa at 1 day and 75 MPa at 28 days; flexure strength minimum of 9 MPa at 28 days. The grout must exhibit positive volumetric expansion in plastic stage as well as hardening stage. Grout must be flowable at 0.15 w/c ratio and shall have fresh wet density in excess of 2200 Kg/m3. The grout must be accredited by reputed testing institute for dynamic load resistance test of 2 million cycles with no sign of cracking or strength loss. All scaffolding, ladders, supporting materials etc. complete. Rates shall be inclusive of all labour, materials, tools and plant etc. complete. |
| 76 | Supply & Fixing of Aluminium Plain Exterior Ventilated Facade of approved wood colour consisting of liniar roll formed aluminium panel 84 mm wide x 16 mm deep x 0.6 mm thick with round edges panel length upto 6 meter coil coated on a continuous paint line double baked and roll formed from enameled corrosion Resistance Aluminum Alloy AA3005 / AA5050 (Al.Mn.) for higher strength and good Roll forming characteristics. Panels shall be clipped at a distance of 146mm with a gap of 60mm between two panels to baked enameled Aluminium panel stringer 33mm wide and 48mm deep x 0.95 mm thick in a standard length of 5mtrs made of double baked enameled Aluminium Alloy AA5050 (Al.Mg.) white/black to hold the panel in a module of 146mm centre to centre. The prongs on stringers shall be to accommodate a gap of 60 mm between two panels as per enclosed profile details. Stringers shall be fixed at 150 mm from panel ends and at a distance of maximum 900 mm center to center across the panel span based on the wind load criteria. The Stringer shall be fixed to a suitable structure by means of rigid fixing details. All properties and specifications shall comply with ECCA directives and more specifically EN 1396:1996. Paint Finish: Panel shall be stove enamelled and finished with standard wood color, a special three layered coating system (consisting of first a conversion layer of thickness 800-2000mg/sqmtr, a polyurethane basecoat of 16-20 microns, and a special top coat of polyamide particles of 8-12 microns thick to provide excellent abrasion and damage resistance) in a continuous coil coating process of the approved colour on the exposed side and the reverse side with epoxy. Complete including Wall, corner profiles as per manufacturers’ specifications etc. (including MS Substructure, Rate to include all ridge, eaves, valley & joints flashing, verge & junction trims, facia, etc. of similar finish, making cut-outs for light fittings, diffusers, columns, etc. as required, complete as per approved shop drawings and as directed/ approved by Engineer.) |
| 77 | Providing and driving Mechanical anchor for 12.5 kn pullout load at M25 concrete grade. M12 stud anchor with 80 mm embedment, M12x115 hef2, Steel galvanized, installation per ETA-98/0001 |
| 78 | Providing and driving Mechanical anchor for 10 kn pullout load at M25 concrete grade. M10x90 stud anchor with 68 mm embedment, M10 hef2, Steel galvanized, installation per ETA-98/0001 |
| 79 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 80 | Proving & laying 25mm Cement concrete flooring 1:2:4 (1cement :2coarse sand:4 graded stone aggregate 12.5mm nominal size) finished with a floating coat of neat cement |
| 81 | White glazed tiles 6 mm thick in flooring treads of steps & landings laid on a bed of 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finished with flush pointing in white cement. |
| 82 | Kotah stone slab flooring over 20 mm (average) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) - 20 mm thick. |
| 83 | Proving & laying Kotah stone slab flooring over 25 mm thick in risers of steps, skirtings, dado & pillars laid on12mm (average) thick cement mortor 1:3 (1 cement : 3 coarse sand) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete. |
| 84 | Rounding of edges of marble/ Granite / Kotah slab to semi circular slope |
| 85 | Providing and laying jet black mirror polish granite flooring and dado over 20mm thick base of cement mortar 1:4 laid over and jointed with cement slurry including rubbling complete Granitic slab (jet black with mirror polish) 20 mm thick add 10% wastage 1.00 |
| 86 | Providing and laying 20mm thick cuddapah in shelves over 20 mm thick base of cement mortar 1:3 complete |
| 87 | Providing and laying 20mm thick cuddapah in shelves complete |
| 88 | Providing & laying 25 mm thick cuddapah slabs machine cut and polished on either side in partitions including making necessary grooves in the wall and fixing with cement mortar, complete as directed by the engineer |
| 89 | Providing and fixing Kota stone tread tiles 35mm thick in single piece with rounded of nosing antiskid groove laid on and including 20mm (average) thk bed of cement slurry including pointing with pigmented cement slurry to match the shade of the slab, cleaning etc. complete. |
| 90 | Providing & laying 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados jointing with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477, using 5 kg. adhesive per sq.m of tile area, in average 3 mm thickness, including pointing in white cement mixed with pigment of matching shade complete. - Wall Ceramic Glazed Tiles : 300 x 450 |
| 91 | Providing & laying 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados jointing with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477, using 5 kg. adhesive per sq.m of tile area, in average 3 mm thickness, including pointing in white cement mixed with pigment of matching shade complete. - Wall Ceramic Glazed Tiles : 300 x 600 |
| 92 | Providing and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete - Light Shades |
| 93 | Providing and laying vitrified floor in different sizes of (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete. - 600 x 600 mm light Shades |
| 94 | Providing and fixing Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps and dados, jointing with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477, using 5 kg. adhesive per sq.m of tile area, in average 3 mm thickness, including pointing/grouting in white cement mixed with pigment of matching shade complete. - 600x600 mm - light Shades |
| 95 | Providing and fixing Granite stone slabs (mirror polished) 18mm thick in risers of steps, skirting, dado and pillars laid on cement paste and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete - Cherry Red |
| 96 | Providing and laying vitrified industrial floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete - 300 x 300 mm Light Shades - 10 mm thick |
| 97 | Providing and and laying vitrified unglazed porcelain tactile floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete - 300x300 Design - Liner/ Button |
| 98 | Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35/M40 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. 60 mm thick in all colours except grey (M35 grade) |
| 99 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm - Jet Black |
| 100 | Vaccum dewatering of laid concrete for roads/ areas using Tremix machinery including formwork with MS channel/ angle sections on sides of concrete with proper supporting system, surface/screed & needle vibrating & levelling of concrete. Vaccum dewatering should be done using suction mats (spread on surface) & suction pump, power floating/ troweling using screen floater, manual spreading of hardening compound (if any), smooth/rough/broom finish to the required slope, camber & level, groove cutting (upto 10mm wide x50mm deep) for contraction/expansion, construction & longitudinal hoints, Providing dowel bars with sleeve/tie bars, filling two component polysuphide sealant/joint filler (Bitumen hot sealing compound: Grade A), taping with masking tape etc complete. (Concrete, reinforcement, Dowel Bar with sleeve/tie bar Reinforcement, tarpaulin sheet to be paid separately) |
| 101 | Providing and fixing rubbed stone slab table, edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer in-charge and finished smooth. - Jet black mirror polish 18mm thick. One side polished and joined together with two component epoxy adhesive to make 18+18mm = 36mm thk partition |
| 102 | Providing & applying Polyurathene-cement self smoothing mortar flooring- 4mm thk. Preparing the existing concrete floor grade using suitable mechanical method scarifier / captive shot blasting machine as per CSP 4 to 5. Treating all construction and control joints before application of floor topping. Cleaning the substrate using an industrial vacuum cleaner thoroughly before application of scratch coat. Providing anchor groves to the size of 8 mm x 8mm at all perimeter and terminations including day joint terminations. Providing Additional groove cutting between panels in the span of 2mt from both the side direction. SCRATCH COAT-Providing and applying of flow applied, PU concrete of 1mm thickness as Scratch coat on well prepared and cleaned concrete floor. This application needs a steel flat leveler or metal squeeze. All grooves and joints to be filled by flow applied, PU Concrete material only. SELF LEVELLING TOP COAT - After tacking free curing of scratch coat (6- 8 hours) apply HACCP, CFTRI approved IGBC certified, 4 component PU concrete flooring at 3mm thickness by notch trowel and spike roller as the product designed by manufacture. This product to be applied at 4mm thickness (-15 ⁰C to 80⁰C for 4mm & -25ºC to +90ºC for 6 mm thermal shock resistance) having Flexural strength i≥13.6MPa as per ASTM D790, Tensile strength: ≥ 6.5 N/mm2; as per ASTM D638; Abrasion resistance: ≤43mg as per CS17 wheel with 1000 cycle rotation as per ASTM D 4060 standard; Impact resistance ASTM D 2794(falling weight: 1 kg): 9.81 Nm.; Hardness of the floor > 80 when tested as per Shore D hardness test ASTM D 2240; skid resistant value of the surface is within 45-50 PTV, a very low risk of slip as per as per BS8204. Fire resistance of class Bfl- s1 as per EN ISO 11925-2 with critical flux value of 12 kW /M2. All as per manufactureres specification complete. |
| 103 | Providing water proofing treatment over the new RCC roofs, terrace, sunken slabs, chajjas by spreading cement slurry over the RCC slab and laying of 100 mm average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba should be covered with damp proof, joint less water proofing plaster of mix 1:3 (1 cement : 3 Fine sand), finish smooth with wooden trowel with false marking of 30cm squares. the Vertical surfaces of the adjoining walls are to be treated upto a height of 30cms including rounding of junctions (The rate includes for complete items including labour and materials and including the cost of initial treatment of roof slab as follows. The injection of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb cracks etc. in the RCC slabs) Note: The cement consumption 25 kg /sq.m. |
| 104 | An elastomeric, cementitious, waterproof coating for concrete and masonry. Providing and applying on a well prepared vertical surface Masterseal 550EL of BASF make or equivalent elastomeric flexible, two component polymers modified cementitious composite system that requires no addition of water at the site. The product shall be applied in minimum two coats to achieve total DFT of 1mm. The material shall be mixed and applied fully in accordance with the manufacturer's instructions. The product shall exhibit at least 40% elongation at ambient & 30% elongation in under water condition with tensile strength greater then 20 Kg/cm2. The product shall resist 1.5 bars pressure when tested as per DIN 1048 at 2mm DFT. When applied at 2mm DFT, elastomeric coating shall be able to bridge crack up to 0.5mm width. All scaffolding, ladders, supporting materials etc. complete. Rates shall be inclusive of all labour, materials, tools and plant etc. complete. |
| 105 | Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 106 | Providing & fixing in position Galvalume/Zincalume flashings, cappings, ridges, gutters upto 600mm/610mm girth and min 3.00m in length (cold Rolled Steel 550 MPa yeild Stress ASTM A 446 Grade E) with hot-dip metallic coating of aluminium-zinc alloy(AZ 150 galvalume) (150 gms/sqm total of both sides with Al-Zn Composition= 55% & 43.5% resp. & 1.5% Si conforming to ASTM 792/ AS 1397) 0.45 mm base metal thickness and 0.50mm total coated thickness, factory cut at all heights for roof, side & gable cladding complete in all respects with AZ 150 GSM SMP color Coated (20mic exterior coat of Silicon Modified Polyester paint system over 5 mic primer and 5 mic polyester back coat over 5 mic primer) incl. fixing to purlins with no 12x14x55mm mechanically galvanised hex head self drilling screws of the best quality as per AS-3566 class 3-4 approved, which should be compatible to be used with sheets. with integral washers and EPDM seals etc. Silicon sealant non-hardening neutral cure type shall be applied at all end laps, complete as directed. |
| 107 | Providing & Fixing in position Double Skin roof with Zincalume/ Galvalume colour coated & bare profile sheet with subtle square fluting factory cut at all heights for roof, side & Gable cladding complete in all respect. TOP SHEET-The end rib shall be designed for anti-capillary action. The feed material should be manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 43.5% Zinc &1.5% Si) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides) with quality paint coat as per AS/NZS 2728 type 3-4. The paint shall have a total coating thickness of nominal 35 μm, comprising of nominal 20 μm exterior SMP coat on top surface and nominal 5 μm reverse backer coat on back surface over nominal 5 μm primer coat on both surfaces of approved colour shade. Total Coated Thickness (TCT) should be 0.50mm. Total Painted Thickness (TPT) should be in addition to 0.50mm. The steel sheet shall be fastened with nominal 40 μm zinc coated or nominal 25 μm zinc-tin alloy coated, Hex head, self-drilling screw as per AS 3566-2002 Class 3 fasteners of approved make with EPDM washer as per the requirement considering the profile shape and design load. The fastener size shall be calculated as per the design or manufacturers recommendations. The profile sheet, fastener size etc. shall be approved by the Engineer. The sheeting should be with minimum 200mm lap & waterproof with Silicon sealant non-hardening neutral cure type shall be applied at all end laps, complete as directed Z-Sub Girt - roll formed section 50x50x50x1.50 TCT, 120GSM Galvanised, High Strength (345 MPa), approximate Wt. 1.85 kg/r.m. fixed with self tapping screws Glass Wool Insulation with FSK facing 50mm with 24 kg/m3 density in between 2 sheets. LINER SHEET-bare galvalume/zincalume roofing sheet of same profile as top sheet. The feed material is of manufactured out of nominal 0.45 mm Base Metal Thickness (BMT) (0.47 mm TCT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 45% Zinc) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides), passivated & resin coated. The feed material should have coil manufacturer’s product details marked at regular interval for confirming genuinity of the material. complete as per the directions of the engineer. The steel manufacturer's test certificate for the chemical & mechanical properties of steel must be submitted for approval prior to installation. |
| 108 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24/15x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25/15 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24/15 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer. - GI Metal Ceiling Lay in plain Tegular/ Bevelled edge Global white color tiles of size 595x595 mm, and 0.4-0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 109 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24/15x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25/15 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24/15 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer. - GI Metal Ceiling Lay in perforated Tegular/ Bevelled edge global white color tiles of size 595x595 mm and 0.4-0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 110 | Providing and Fixing M/F suspended ceiling (Single Layer) which includes providing & fixing GI perimeter channels of size 0.55mm thk having one flange of 20mm and another flange of 30mm and a web of 27mm along with perimeter of ceiling, screw fixed to brickwall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending GI intermediate channels of size 45mm, 0.9mm thk with two flanges of 15mm each from the soffit at 1220mm centres with ceiling angle of width 25mmx10mmx0.55mm fixed to soffit with GI cleat and steel expansion fastners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to the intermediate channel at 457 mm centres. 8mm tapered edge Calcium Silicate Board is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, Joint paper tape and 2 coats of Drywall topcoat Suitable for Calcium Silicate board, complete in all respects. |
| 111 | Providing and laying integral cement based treatment (Box type) for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer and consisting of : i) Ist layer of 20 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer using rough Shahbad/Kotah stone. |
| 112 | Providing and laying integral cement based treatment (Box type) for water proofing on the vertical surface by fixing specified stone slab 20 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer using rough Shahbad/Kotah stone. |
| 113 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 114 | 12mm cement plaster 1:4 (1cement: 4 fine sand) |
| 115 | 6mm cement plaster to ceiling 1:3 (1 cement : 3 fine sand) |
| 116 | neat cement punning |
| 117 | Extra for providing and mixing water proofing material proportion recommended by the manufacturers. a) 12mm cement plaster 1:4 (1 cement : 4 sand) |
| 118 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge including providing and mixing water proofing material proportion recommended by the manufacturers. |
| 119 | 12mm thick molded cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand) cm per meter |
| 120 | White washing with lime on new work (three or more coats) to give an even shade including minimum one priming coat |
| 121 | Applying priming coat with ready mixed primer of approved brand and manufacture on wood work complete. |
| 122 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 123 | Painting two or more coats (excluding priming coat ) with superior quality ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give a even shade |
| 124 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for wood work of approved brand & manufacture in all shades on new work to give an even shade. |
| 125 | Painting(two or more coats) with synthetic enamel paint of approved brand and manufacture in all shades on new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture to give an even shade |
| 126 | Painting (one or more coats) with black japan paint of approved brand and manufacture to give an even shade. |
| 127 | Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade (including min two priming coats and two layers of putty alternatively) |
| 128 | Varnishing (two or more coats) with copal varnish of approved brand and manufacture on new work including an under coat Bees waxing on wood work with local made wax polish in proportion of 2:1 5:1 0.5 (2 wax: 1.5 linseed oil - With transparent wood filler. |
| 129 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as Dulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete, At all heights from ground level |
| 130 | Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the exposed laterite masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer. (The rate is inclusive of all materials & labours). |
| 131 | Melamine polishing on wood work (one or more coat) - Matt |
| 132 | Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints, etc. complete.- a) 100 mm dia RCC pipe |
| 133 | Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints, etc. complete.- a) 250 mm dia RCC pipe |
| 134 | Supplying of granitic or basaltic stone soling of size 15-20 cm and Murrum having P.I. Value not more than 6 and laying including packing with smaller stones and consolidation with power roller including spreading waters and consolidation of binding material etc. complete.(Measurements shall be considered on finished item.and and layer of WBM of 50/75mm thick shall be taken seperately over this sub-base to obtain smooth surface, as per the directives of Engineerin-charge). |
| 135 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3-wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregates, watering & compacting to the required density, making necessary earthern bund to protect edges, lighting, guarding, barricading, and maintainance of diversion etc complete as per MoRT & H specification no 404. - By mechanical means - Grade II |
| 136 | Providing and applying tack coat with bitumen grade of 80/100 or bitumen emulsion using pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom as per MoRT&H specifications clause 503., - Bitumen 80/100 @0.375 Kg/m2. |
| 137 | Providing and laying 50mm (consolidated thickness) full grout using granitic or basaltic stone of specified grading at 6.00 cu.m. per 100 sq.m. grouting with hot bitumen straight run bitumen(or with such bituminous material of grade and type as specified by the Engineer-in-Charge)at 5.0kg. per sq. m. binding with key aggregate of granitic or basaltic stone of specified grading at 1.5 cu.m. per 100 sq.m. including Providing and laying seal coat sealing the voids in a bituminious surface laid with F.E loader with 1 Cu.m. bucket capacity to the specified levels, grade and cross fall using Type A seal coat with 0.98 kg/sqm of bitumen of grade as per MoRT&H specifications clause 513. |
| 138 | Providing and fixing weepholes with rigid PVC make laid in position with a required slope and level while laying pipes of approved the concrete of retaining wall,wing wall and earth retainig structure complete as directed by the Engineer in charge - 110mm dia |
| 139 | Providing and laying filter media with Granular materials crushed stone Aggregates satisfying the rerquirement As Per Clause 2504.2.2 of MOSRT & H Specification to a thickness of 500 mm laid horizontally in layers of 250mm thick and compacted to firm condition etc. complete as direction by Engineer-in-charge. |
| 140 | Planting of trees by the roadside (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground mixing the soil with decayed farmyard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year as per MORTH Specification 307 |
| 141 | Supplying and stacking of good earth at site including royalty and carriage upto 1km (earth measured in stacks will be reduced by 20% for payment) including Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farmyard manure or/and good earth to be paid for separately) |
| 142 | Turfing lawns with fine grassing including ploughning, dressing including breaking of clods, removal of rubbish, dressing and supplying doob grass roots at 10 cm apart including supplying and spreading of farmyard manure at rate of 0.6 cum per 100 sqm as per MORT&H Specification 307 including Maintenance of lawns with fine grassing for three years including watering, etc.as per MORTH Specification 307 |
| 143 | Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metre and supplying and planting hedge plants at 30 cm apart as per MORT & H Specification 307 including maintenance of hedge for three years including watering etc. |
| 144 | Supply at site of work well decayed farmyard manure, from any available source approved by the engineer including screening and stacking as per MORT & H Specification 308.2 including Spreading of sludge farm yard manure in required thickness as per MORT & H Specification 307 |
| 145 | Providing and fixing Rigid PVC (SELFIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc, conforming to ASTM 2467 with ISO 14001, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer.conforming to IS 4985-2000 and bearing ISI mark, CLASS 6 KG/ SQ. CM a) Outer dia 63 mm |
| 146 | Providing and fixing Rigid PVC (SELFIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc, conforming to ASTM 2467 with ISO 14001, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer.conforming to IS 4985-2000 and bearing ISI mark, CLASS 6 KG/ SQ. CM b) 75 mm |
| 147 | Providing and fixing Rigid PVC (SELFIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc, conforming to ASTM 2467 with ISO 14001, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer.conforming to IS 4985-2000 and bearing ISI mark, CLASS 6 KG/ SQ. CM c) 110 mm |
| 148 | Providing and fixing Rigid PVC (SELFIT) pipes for public water supply including Railway freight, carting, loading and unloading, stacking, transit insurance etc, conforming to ASTM 2467 with ISO 14001, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer.conforming to IS 4985-2000 and bearing ISI mark, CLASS 6 KG/ SQ. CM d) 140 mm |
| 149 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. SCH-40 (blue)/(white) - 25mm outer dia. |
| 150 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. SCH-40 (blue)/(white) 32mm outer dia |
| 151 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. SCH-40 (blue)/(white) 40mm outer dia |
| 152 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. SCH-40 (blue)/(white) 50mm outer dia. |
| 153 | Proving and fixing white vitreous china water closet squatting pan (Indian type w.c. pan) size 580 mm with 100 mm sand cast iron P. or S trap 10 litres high level P.V.C. flushing cister (of approved make) with fittings, rack bolts 32 mm diameter P.V.C telescopic flush pipe with fit tings and clamps 25mm P.V.C. over flow pipe with specials & mosquito proof coupling of approved municipal design and nylon pull complete cutting and making good the walls and floors where required.a) Orissa pattern W.C. pan |
| 154 | Proving and fixing white vitreous china extended Wall Hung type (European Type) water closet of approved shape with seat and lid with C.I. brass hinges and rubber fittings with white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/ 8 litre), etc. including chair bracket/rag bolts, cutting & making good the walls and floors where required and concealed seat support - W.C. Pan with white plastic seat and lid |
| 155 | Providing and fixing vitreous china under counter wash basin with RS or C.I. brackets painted white, NICKEL chrome plated copper alloy Fancy Pillar Cock rocket type Jaquar make or equivalent. Confirming to IS 8931;1993, 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. Or C.P. brass trap and union complete, including cutting and making good the walls where required. - wash basin 550x400/Oval 560x410mm/ round 550x450mm including cutting in base etc complete with sealing |
| 156 | Proving and fixing kitchen sink with R.S. or C.I. brackets C.P. brass chain with rubber plug 40 mm C.P. brass waste and 40mm M.I. or C.P. brass trap necessary unions complete, including painting the fittings, cutting and making good the walls where required. White vitreous china sink size 600 x 450 x 200 mm |
| 157 | Providing & fixing bevelled edge mirror of superior glass (5mm thk) of approved Quality, shape & size complete with CP brass screws and washers, Cleats, CP studs etc Complete |
| 158 | Providing & fixing C.P. Brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. Brass Screws - 600x20mm size |
| 159 | Providing and fixing toilet paper holder - C.P. brass |
| 160 | Providing & fixing soap dish chromium plated with brackets fixed to wooden cleats with CP brass screw |
| 161 | Fixing water meter and stop cock in G.I. Pipe line including cutting and threading the pipe and making long screw etc. complete ( cost of water meter and stop cock to be paid separately. |
| 162 | Providing and fixing brass stop cock (heavy) of approved quality - 20mm nominal bore |
| 163 | Providing and fixing brass stop cock (heavy) of approved qualit 25mm nominal bore |
| 164 | Providing and fixing brass stop cock (heavy) of approved qualit 32mm nominal bore |
| 165 | Providing and fixing brass stop cock (heavy) of approved qualit 40mm nominal bore |
| 166 | Providing and fixing brass stop cock (heavy) of approved qualit 50mm nominal bore |
| 167 | Providing and fixing brass full way valve (heavy duty) with wheel of approved quality - 20mm nominal bore |
| 168 | Providing and fixing brass full way valve (heavy duty) with wheel of approved quality 25mm nominal bore |
| 169 | Providing and fixing brass full way valve (heavy duty) with wheel of approved quality 40mm nominal bore |
| 170 | Providing and fixing brass full way valve (heavy duty) with wheel of approved quality 50mm nominal bore |
| 171 | Providing and fixing ball valve (brass) of approved quality High pressure with P.V.C. floats - 20mm nominal bore |
| 172 | Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with C.I grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design - 150 x 100 mm size – P or S type |
| 173 | Constructing brick masonry manholes or inspection chamber with second class bricks in cement mortar 1:5 (1 Cement : 5 Fine Sand), RCC top slab 1:1.5:3 mix (1 Cement :1.5 Coarse Sand : 3 graded stone aggregate 20mm nominal size) Foundation concrete 1:1.5:3 (1 Cement :1.5 Coarse Sand : 3 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 Cement : 3 Coarse Sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4mix (1 Cement :2 Coarse Sand : 4 graded stone aggregate 20mm nominal size) neatly finished complete as per standard design. a) Inside size 90x80 cm and 60 cm deep including Supplying and fixing at the site of work of Steel Fibre Reinforced Concrete (SFRC) manhole covers with frames made as per IS :12592 (part I and II) - 1991 in concrete M45grade. The covers and lapped in 2mm thick. steel plate and this plate & lifting hooks are duly painted in corrosion resistant epoxy paint etc. complete. Light Duty (2.50 Metric Tonne Capacity) a) 450x900 |
| 174 | Constructing brick masonry manholes or inspection chamber with second class bricks in cement mortar 1:5 (1 Cement : 5 Fine Sand), RCC top slab 1:1.5:3 mix (1 Cement :1.5 Coarse Sand : 3 graded stone aggregate 20mm nominal size) Foundation concrete 1:1.5:3 (1 Cement :1.5 Coarse Sand : 3 graded stone aggregate 20mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 Cement : 3 Coarse Sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4mix (1 Cement :2 Coarse Sand : 4 graded stone aggregate 20mm nominal size) neatly finished complete as per standard design. b) Inside size 60x60 cm and 60 cm deep including Supplying and fixing at the site of work of Steel Fibre Reinforced Concrete (SFRC) manhole covers with frames made as per IS :12592 (part I and II) - 1991 in concrete M45grade. The covers and lapped in 2mm thick. steel plate and this plate & lifting hooks are duly painted in corrosion resistant epoxy paint etc. complete. Light Duty (2.50 Metric Tonne Capacity) b) 450x600 |
| 175 | Supplying and fixing at the site of work of Steel Fibre Reinforced Concrete (SFRC) manhole covers with frames made as per IS :12592 (part I and II) - 1991 in concrete M45grade. The covers and lapped in 2mm thick. steel plate and this plate & lifting hooks are duly painted in corrosion resistant epoxy paint etc. complete. Light Duty (2.50 Metric Tonne Capacity) a) 450x600 mm |
| 176 | Extra for depth for manholes : a) size 90 x 80 cm |
| 177 | Constructing soak pit 1.20m x 1.20m x1.20m filled with laterite stone aggregate 125 to 180 mm including S.W. drain pipe 100 mm diameter and 1.2m. long complete as per standard design. : |
| 178 | Making soak pit. 2.5 m dia 3 m deep with 45x45 cm dry brick honey comb shaft and S.W. drain pipe 100 mm diameter, 1.8 m long complete filled with laterite stone aggregate 125 to 180 mm surrounded by laterite stone aggregate of 40 mm and down gauge as per standard design. |
| 179 | Providing & fixing rigid PVC SWR (soil, waste and rain water drainage pipes of approved make including lubricant etc. complete ( single/double socketed) - 110 mm dia |
| 180 | Providing & fixing rigid PVC SWR (soil, waste and rain water drainage pipes of approved make including lubricant etc. complete ( single/double socketed 75 mm dia |
| 181 | Providing & fixing rigid PVC bend (approved make) for SWR pipes including lubricating etc. complete bend with door - 110 mm dia |
| 182 | Providing & fixing rigid PVC bend (approved make) for SWR pipes including lubricating etc. complete bend with door 75 mm dia |
| 183 | Providing & fixing single Tee of rigid PVC (approved make) for SWR pipes including lubricating etc. complete bend with door - 110 mm dia |
| 184 | Providing & fixing single Tee of rigid PVC (approved make) for SWR pipes including lubricating etc. complete bend with door 75 mm dia |
| 185 | Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door - 110 mm dia |
| 186 | Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with doo 75 mm dia |
| 187 | Providing and fixing double “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door - 110 mm dia |
| 188 | Providing and fixing double “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door 75 mm dia |
| 189 | Providing & fixing Nahani trap of rigid PVC of (approved make) for SWR pipes including lubricating etc complete with SS door - 75mm dia |
| 190 | Providing & fixing U.P.V.C. pipe clips (approved make) for S.W.R pipe - 110mm |
| 191 | Providing & fixing U.P.V.C. pipe clips (approved make) for S.W.R pipe 75mm dia |
| 192 | Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993 - 15mm nominal bore |
| 193 | Providing and fixing NICKEL chrome plated copper alloy Fancy long body bib cock with wall flance Jaquar make or equivalent. Confirming to IS 8931;1993 - 15mm nominal bore |
| 194 | Providing and fixing NICKEL chrome plated copper alloy Fancy ANGULAR STOP COCK WITH SLINDING FLANCE 15MM Jaquar make or equivalent. Confirming to IS 8931;1993 - 15mm nominal bore |
| 195 | Providing and fixing NICKEL chrome plated copper alloy Fancy CONCEALED STOP COCK WITH sheet flance 20mm Jaquar make or equivalent. Confirming to IS 8931;1993 - 20mm nominal bore |
| 196 | Providing and fixing P.V.C. connection pipe with brass unions 15 mm nominal bore - a) 30 cm (12\\") length |
| 197 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. - 15 mm dia nominal outer dia pipes. |
| 198 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc 20 mm dia nominal outer dia pipes. |
| 199 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc 25 mm dia nominal outer dia pipes. |
| 200 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc 32 mm dia nominal outer dia pipes. |
| 201 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) - 20mm outer dia. |
| 202 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) 25 mm dia nominal outer dia pipes. |
| 203 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) 32 mm dia nominal outer dia pipes. |
| 204 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) 40 mm dia nominal outer dia pipes. |
| 205 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work. SCH-40 (blue)/(White) 50 mm dia nominal outer dia pipes. |
| 206 | Supplying & Fixing C.I. Foot valve with metal valve and seat full bore type, having total area through strainer perforations three times that of pipe size suitable for working pressure of 2 kg/sq.cm. As per IS: 4038 (lift type) - 50 mm dia |
| 207 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 including cutting of stone and making good the walls wherever required. Kitchen sink without drain board. with coupling & all accessories complete with choke stop strainer, Plain type having flat borders for correct sandwithing between the plaform top and bottom slabs complete - Overall size 535mmx460mm (21\\"x18\\") bowl size 460mmx380mmx200mm (18\\"x 15\\"x 8\\") depth 200 mm. Glossy. 1.0mm thk, |
| 208 | Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards. |
| 209 | Providing and fixing NICKEL chrome plated copper alloy Fancy Two Way Bib Cock with single knob and wall flange conforming to IS 8931:1993 15mm nominal bore. |
| 210 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/Cuddapah stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 211 | Construction of meter box of size1.00x0.45x0.90 m in laterite stone masonry in cement mortar1:5 (1cement :5coarse sand). Foundation concrete of 8cm thick 1:4:8 (1 cement : 4 coarse sand : 8 graded granitic or basaltic stone aggregate 40mm nominal size) RCC top slab 8cm thick 1:2:4 (1Cement:2 coarse sand:4 graded granitic or basaltic stone aggregate 20mm nominal size) including high yield steel bars 8mm dia. 4 nos. each in both directions finished with 12mm thick cement plaster 1:6 (1 cement:6 coarse sand) including white washing with lime, two or more coats to give an even shade. Providing & fixing door cover of mild steel angle frame of size 20mmx20mmx3mm including necessary hinges and holdfast of size 100mmx20mmx3mm (2 Nos.), paintings etc. complete as directed by the Departmental Officer (rate inclusive of earthwork in excavation, rubble packing 10cm thick, refilling of excavated earth etc. complete as per the standard drawing). In the various Scattered locations as per the direction of the Engineer -in-charge |
| 212 | Providing and fixing white vitreous china flat back Large lipped front urinal basin of 590x375x390mm size with Urinal Valve Auto closing system with built in control cock & wall flange with fittings, spreader, R.S. or C.I. brackets, standard size C.P. Brassl flush pipe and spreaders with C. P. brass unions & C. P. Brass clamps with waste fitting as per IS 2556, PVC trap with outlet grating and other couplings in CP Brass complete, including painting, fittings, cutting and making good the walls and floors where required. - Range of one urinal basin |
| 213 | Providing anti termite treatment to the building conforming to IS:6313 (part II) 1971 adopted, including adopting the precautions for health hazards and safety measures as required therein with the cost of all materials, chemicals plants, equipments etc required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicating any infestation of termite free of cost during the guarantee period complete. The payment will be made on the Plinth of the building) - Preconstruction |
| 214 | Providing & fixing in position traction matting antiskid clear tape 2 inch wide (50mm) for staircase having Granite Treads. The antiskid clear tape should be mineral coated slip resistant material with pressure sensitive adhesive including cleaning, degreasing, priming to mask the surface (if required), presssing using rubber roller etc. complete |
| 215 | Providing & Fixing Signage made of 6mm thick transperent/ coloured acrylic sheet base material. The graphic should be computer cut self adhesive vinyl covered with clear vinyl to protect from peeling. The signage should be fixed with 12mm dia S.S. studs or S. S. Mirror screws. |
| 216 | Providing and fixing signages made from aluminium composite panel 4mm thk. base material with computer cut self adhesive vinyl graphic covered with clear vinyl to protect from peeling. The signage shall be fixed with 12mm dia S.S. studs or S.S. mirror screws. |
| 217 | Providing & Fixing in position Autoglow photoluminescent Signage made of 1.5mm thick Rigid sheet as base material. The colour, text, size graphic symbol should be as specified by the Fire and Safety Department and IS code 12349(1988) (Reaffirmed 2002) . The signages should be approved by the engineer in charge. The signage should be fixed with 12mm dia S.S. studs or S. S. Mirror screws.. |
| 218 | Providing & Fixing Backlit LED (6500k, 2W), double sided Emergency Escape Signages showing directional arrow, text and size as directed by engineer in charge. It should contain powder coated steel/ Aluminium fabricated frame. It should have provision to Hang to ceiling with the help of SS chain at both ends. Operating voltage 230VAC/24VDC/ 12VDC with battery operated.IT should have rechargeable battery with back up time more than 90 minutes. IP20 rating. approx size 300-320x 170-180x35mm. |
| 219 | Proving and laying 120 microns waterproof plastic film/sheet as per IS 14611-1998 as a separation/slip membrane laid flat without creases and with minimum overlap of 200mm at joints, nailed to underneath Plain Cement concrete, if required as directed. |
| 220 | Providing & fixing in position fixed glass for shower partition with 10mm toughened clear glass on patch fittings in SS 316 grade, Reinforcement bar, silicone sealant Complete. |
| 221 | Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead. |
| 222 | Demolishing brick work in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 223 | LIFT WORKS |
| 224 | Supplying, Installing, Testing & Commissioning (SITC) of Electric Traction Passenger Lift with• Rated capacity :- 8 Passenger/544Kg• Floors :- G+3 floor (4 Stops/4 Landings)• Travel :- 12.30 mtr approx• Location of Lift Machine:- Machine Room Less (MRL) • Rated speed :- 1.0mps Variable speed (VS) • Car/Landing door clear opening of 800 mm wide x 2000 mm high• Clear Car size of 1100 mm wide x 1300 mm deep x 2250mm high• Lift shaft available having clear size of 2300 mm wide x1800 mm deep, 1600 mm Pit depth, 4100mm Overhead.• Doors type :- Centre Opening Power Operated (COPO)/ Telescopic Opening Power Operated (TOPO) Doors with frame made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). • Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights having light intensity of at least 100 lux in car, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• Car Operating Panel (COP) with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with Floor Position Indicator (FPI), scrolling UP/DN LED indicator & with/without attendant key switch, Overload warning Device (OWD) with audio-visual alarm, Voice annunciation system (VAS) in Konkani/Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor • Landing Operating Panel (LOP) with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with Car Position Indicator (CPI), Lift car arrival & next travel direction audio-visual indication at all landings. • Lift controller based on microprocessor/ Programmable Logic Control (PLC) with Variable Voltage Variable Frequency (VVVF) Drive having closed loop control system, with Intelligent Building Management System (IBMS) compatible having necessary port. The controller shall have necessary protections such as over current, over voltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. • Automatic Rescue Device (ARD) complete with necessary Sealed maintenance free (SMF) Valve-Regulated Lead-Acid (VRLA) batteries shall be such that minimum three consecutive rescue operations can be performed without recharging for the maximum travel distance between two consecutive served stops. ARD have a suitable audio alarm with visual indication or voice annunciation in the lift car or lift controller to indicate “Low battery”.• Fireman controller having fireman switch at fire Landing,• Closed Circuit Television (CCTV) surveillance system comprises of 2 nos minimum 2.0MP FHD IP (Internet Protocol) based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with Network Video Recorder (NVR) kept in LMR/Fire Command Centre (FCC) with High Definition Recording (HDR) data backup for 90 days with 18 20\\" Full High Definition (FHD) TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless Permanent Magnet Synchronous AC Machine (PMSM) of suitable kW with duty cycle of minimum 120 starts per hour (with submission of necessary test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, Over speed safety governor (OSG), electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on Lift machine room (LMR) floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. • Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. • Minor civil work such as alteration work if any necessary for erection of landing door frames and its accessories eg. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing & fixing steel girders/RCC work having adequete strength for mounting & Hosting lift machine etc. complete as per specification no. LFT.Including For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door at all floors [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories, door operator mechanism with drive, required aluminium sill, infrared curtain & necessary wiring with interlocking arrangement etc. necessary for the normal safe functioning of lift installation complete. • Full Collective Control System •SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex Lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVCconduits/trunking etc. complete 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.tor, to be kept in FCC/LMR as directed by Engineer In Charge. |
| 225 | Supplying, Installing, Testing & Commissioning (SITC) of Electric Traction Passenger cum Stretcher/ Hospital cum Goods Lift with• Rated capacity :- 15 Passenger 1020Kg• Floors :- G+4 floor (5 Stops/5 Landings)• Travel :- 16.05 mtr approx• Location of Lift Machine:- Machine Room Less (MRL) • Rated speed :- 1.0mps Variable speed (VS) • Car/Landing door clear opening of 1000 mm wide x 2300 mm high• Clear Car size of 1000 mm wide x 2400 mm deep x 2550mm high• Lift shaft available having clear size of 2010 mm wide x2750 mm deep, 1600 mm Pit depth, 4100mm Overhead.• Doors type :- Centre Opening Power Operated (COPO)/ Telescopic Opening Power Operated (TOPO) Doors with frame made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). • Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights having light intensity of at least 100 lux in car, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• Car Operating Panel (COP) with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with Floor Position Indicator (FPI), scrolling UP/DN LED indicator & with/without attendant key switch, Overload warning Device (OWD) with audio-visual alarm, Voice annunciation system (VAS) in Konkani/Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor • Landing Operating Panel (LOP) with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with Car Position Indicator (CPI), Lift car arrival & next travel direction audio-visual indication at all landings. • Lift controller based on microprocessor/ Programmable Logic Control (PLC) with Variable Voltage Variable Frequency (VVVF) Drive having closed loop control system, with Intelligent Building Management System (IBMS) compatible having necessary port. The controller shall have necessary protections such as over current, over voltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. • Automatic Rescue Device (ARD) complete with necessary Sealed maintenance free (SMF) Valve-Regulated Lead-Acid (VRLA) batteries shall be such that minimum three consecutive rescue operations can be performed without recharging for the maximum travel distance between two consecutive served stops. ARD have a suitable audio alarm with visual indication or voice annunciation in the lift car or lift controller to indicate “Low battery”.• Fireman controller having fireman switch at fire Landing,• Closed Circuit Television (CCTV) surveillance system comprises of 2 nos minimum 2.0MP FHD IP (Internet Protocol) based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with Network Video Recorder (NVR) kept in LMR/Fire Command Centre (FCC) with High Definition Recording (HDR) data backup for 90 days with 18 20\\" Full High Definition (FHD) TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless Permanent Magnet Synchronous AC Machine (PMSM) of suitable kW with duty cycle of minimum 120 starts per hour (with submission of necessary test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, Over speed safety governor (OSG), electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on Lift machine room (LMR) floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. • Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. • Minor civil work such as alteration work if any necessary for erection of landing door frames and its accessories eg. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing & fixing steel girders/RCC work having adequete strength for mounting & Hosting lift machine etc. complete as per specification no. LFT.Including For Lift having 1000mm wide x 2300mm high clear entrance in 1.5mm thick SS 304 grade landing door at all floors [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories, door operator mechanism with drive, required aluminium sill, infrared curtain & necessary wiring with interlocking arrangement etc. necessary for the normal safe functioning of lift installation complete. • Full Collective Control System •SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex Lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVCconduits/trunking etc. complete 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.tor, to be kept in FCC/LMR as directed by Engineer In Charge. |
| 226 | Supplying, Installing, Testing & Commissioning (SITC) of Electric Traction Passenger cum Stretcher/ Hospital cum Goods Lift with• Rated capacity :- 20 Passenger 1360Kg• Floors :- G+4 floor (5 Stops/5 Landings)• Travel :- 16.05 mtr approx• Location of Lift Machine:- Machine Room Less (MRL) • Rated speed :- 1.0mps Variable speed (VS) • Car/Landing door clear opening of 1200 mm wide x 2300 mm high• Clear Car size of 1700 mm wide x 2000 mm deep x 2550mm high• Lift shaft available having clear size of 2600 mm wide x3100 mm deep, 1600 mm Pit depth, 4100mm Overhead.• Doors type :- Centre Opening Power Operated (COPO)/ Telescopic Opening Power Operated (TOPO) Doors with frame made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). • Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights having light intensity of at least 100 lux in car, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• Car Operating Panel (COP) with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with Floor Position Indicator (FPI), scrolling UP/DN LED indicator & with/without attendant key switch, Overload warning Device (OWD) with audio-visual alarm, Voice annunciation system (VAS) in Konkani/Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor • Landing Operating Panel (LOP) with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with Car Position Indicator (CPI), Lift car arrival & next travel direction audio-visual indication at all landings. • Lift controller based on microprocessor/ Programmable Logic Control (PLC) with Variable Voltage Variable Frequency (VVVF) Drive having closed loop control system, with Intelligent Building Management System (IBMS) compatible having necessary port. The controller shall have necessary protections such as over current, over voltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. • Automatic Rescue Device (ARD) complete with necessary Sealed maintenance free (SMF) Valve-Regulated Lead-Acid (VRLA) batteries shall be such that minimum three consecutive rescue operations can be performed without recharging for the maximum travel distance between two consecutive served stops. ARD have a suitable audio alarm with visual indication or voice annunciation in the lift car or lift controller to indicate “Low battery”.• Fireman controller having fireman switch at fire Landing,• Closed Circuit Television (CCTV) surveillance system comprises of 2 nos minimum 2.0MP FHD IP (Internet Protocol) based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with Network Video Recorder (NVR) kept in LMR/Fire Command Centre (FCC) with High Definition Recording (HDR) data backup for 90 days with 18 20\\" Full High Definition (FHD) TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.• Lift Machine of Gearless Permanent Magnet Synchronous AC Machine (PMSM) of suitable kW with duty cycle of minimum 120 starts per hour (with submission of necessary test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, Over speed safety governor (OSG), electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on Lift machine room (LMR) floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. • Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. • Minor civil work such as alteration work if any necessary for erection of landing door frames and its accessories eg. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing & fixing steel girders/RCC work having adequete strength for mounting & Hosting lift machine etc. complete as per specification no. LFT.Including For Lift having 1200mm wide x 2300mm high clear entrance in 1.5mm thick SS 304 grade landing door at all floors [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories, door operator mechanism with drive, required aluminium sill, infrared curtain & necessary wiring with interlocking arrangement etc. necessary for the normal safe functioning of lift installation complete. • Full Collective Control System •SITC of Duplex Lift control system for two nos. microprocessor/PLC based simplex Lift controllers along with necessary software with programming and hardware e.g. logic board, necessary communication/control/data cabling laying in rigid PVCconduits/trunking etc. complete 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.tor, to be kept in FCC/LMR as directed by Engineer In Charge. |
| 227 | ELECTRICAL WORKS |
| 228 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit (heavy) with modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) Group C -- with Cat B Modular Accessories |
| 229 | Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit (heavy) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 230 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with 2 way modular switch, modular plates, suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (a) with Cat B Modular accessories |
| 231 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (a) Cat B |
| 232 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/ 6 A modular switch connection painting etc. as required. - Cat B |
| 233 | Supplying and fixing suitable size modular GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and 15/16 A modular switch connection painting etc. as required. - Cat B |
| 234 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate etc. as required - Cat B |
| 235 | Supply and erecting fan hook box (100 mm diameter or equivalent square size, 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box, including painting with 2 coats of red oxide, complete as required. |
| 236 | Supply and erecting of 9 inch (225 mm sweep) exhaust fan with double ball bearings, 1400 rpm, complete with all accessories. a) Cat A |
| 237 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 238 | Supplying and erecting anodized aluminium light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block/wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 239 | Supplying and erecting CRCA powder coated light LED fitting (4 feet) Max. 50W with high transitivity diffuser with system lumens output of Min. 6000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs at L70B50, rated including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 240 | Supplying and fixing brass batten/ angle holder including connections etc as required. |
| 241 | Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22/E-27 base as per specification no. FG-LP. |
| 242 | Supplying and erecting LED Panel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 243 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit (heavy) of appropriate size as required. (a) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 244 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit (heavy) of appropriate size as required. (b) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit) |
| 245 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/ recessed steel PVC conduit or casing caping, including dismantling, removing old wires as required. - 2 x 6 sq.mm |
| 246 | Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) :- (a) 6 way (4+18), double door, Horizontal type Cat B |
| 247 | Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) :- (a) 8 way (8+24), double door, Horizontal type Cat B |
| 248 | Supplying installation testing and commissioning of surface/ recess mounting vertical type 415 V TPN, double door MCB DB of sheet steel dust protected duly phosphatised and powder painted inclusive of 200 A tinned copper busbar common neutral link earth bar din bar for mounting MCBs detachable gland knock out plate and with 100 A 10 KA MCCB as incomer interconnection between incomer MCCB and busbars of following ways (but without MCCB/MCBs as required) a) 8 way with 100A MCCB as Incomer, double door, Cat B |
| 249 | Supplying installation testing and commissioning of surface/ recess mounting vertical type 415 V TPN, double door MCB DB of sheet steel dust protected duly phosphatised and powder painted inclusive of 200 A tinned copper busbar common neutral link earth bar din bar for mounting MCBs detachable gland knock out plate and with 100 A 10 KA MCCB as incomer interconnection between incomer MCCB and busbars of following ways (but without MCCB/MCBs as required) b) 12 way with 100A MCCB as Incomer, double door, Cat B |
| 250 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (a) SP, Cat B |
| 251 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (j) TP, Cat B |
| 252 | Supplying and fixing 40 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.. - TPN, Cat B |
| 253 | Providing and fixing following rating and breaking capacity fixed type/adjustible 3 pole MCCB inside the existing cubicle panel board including drilling holes in cubicle panel making connections etc as required - a) 100 A 25 KA, CAT B |
| 254 | Supplying and fixing SP blanking plate in the existing MCB DB complete as required |
| 255 | Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil. c)Watering GI pipe, 20mm, Class B, with funnel as per specs. d) Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately). (a) In rocky strata |
| 256 | Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt) |
| 257 | Supplying and laying 25 mm x 5 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required |
| 258 | Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required |
| 259 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop arthing . as required |
| 260 | Supplying and Installing following size welded ladder type , 75mm depth, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required -300 mm width X 75 mm depth with runner size 20x75x20mmmm, rung size 20x40x20mm with rungs at 250mm c/c.(14SWG) |
| 261 | Supplying and Installing following size welded ladder type , 50mm depth, M.S.cable tray bend of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required-300 mm width X 50 mm depth with runner size 15x50x15mm, rung size 20x40x20mm with rungs at 250mm c/c.(14SWG) |
| 262 | Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. a) 3 1/2 Core 300 sq.mm |
| 263 | Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. b) 1/2 Core 240 sq.mm |
| 264 | Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. c) 3 1/2 Core 95 sq.mm |
| 265 | Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. d) 3 1/2 Core 35 sq.mm |
| 266 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. (a) 4 Core 16 sq.mm |
| 267 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) , IS:7098(Part I) with latest amendments of following size. (a) 4 Core 6 sq.mm |
| 268 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) , IS:7098(Part I) with latest amendments of following size. (b) 4 Core 4 sq.mm |
| 269 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) , IS:7098(Part I) with latest amendments of following size. (c) 4 Core 2.5 sq.mm |
| 270 | Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. (a) 3 Core 2.5 sq.mm |
| 271 | Supply of 3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) , IS:7098(Part I) with latest amendments of following size (a) 3 Core 1.5 sq.mm |
| 272 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. a) 3 1/2 Core 300 sq.mm |
| 273 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. b) 3 1/2 Core 240 sq.mm |
| 274 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. c) 3 1/2 Core 95 sq.mm |
| 275 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. d) 3 1/2 Core 35 sq.mm |
| 276 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. (a) 4 x 16 Sq. mm. |
| 277 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. - 4 x 1.5/2.5 Sq. mm. (a) 4 Core 6 sq.mm |
| 278 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. - 4 x 1.5/2.5 Sq. mm. (b) 4 Core 4 sq.mm |
| 279 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. - 4 x 1.5/2.5 Sq. mm. (c) 4 Core 2.5 sq.mm |
| 280 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.- 3 x 1.5/2.5 Sq. mm. |
| 281 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable)and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. - In Rocky Strata |
| 282 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. - In Rocky Strata |
| 283 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing masonry open duct, etc. complete as required |
| 284 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing masonry open duct, etc. complete as required |
| 285 | Supply and fixing of cable route marker 15 cms diameter of GI plate 6mm thick with inscription theron bolted or welded to 25mm x 25mmx 5mm angle iron 60 cms long and fixing the same in ground with PCC etc complete as required. |
| 286 | Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm |
| 287 | Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-11 connector(modular telephone socket) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required. a) CAT B |
| 288 | Supplying and drawing/fixing indoor type 0.5 sq.mm FR PVC insulated copper conductor unarmoured telephone cable ITD/DOT approved, with GI saddles on wall or in the existing surface/recesed steel/PVC conduit having folowing pair(s), complete as required. a) 2 Pair |
| 289 | Supplying and drawing/fixing jelly filled outdoor type armoured telephone cable with 0.5 sq.mm dia. tinned copper conductor, ITD/DOT approved, with GI saddles on wall or in the existing surface/recesed steel/PVC conduit having folowing pair(s), complete as required. a) 10 Pair |
| 290 | Supplying, installing, testing and commissioning of Junction Box, ITD/DOT approved, indoor type with wall mounting/concealed facility having front door with lock along with aluminium frame for mounting disconnection type Krone modules, complete cabinet fabricated from 18 SWG CRCA sheet with powder coating in appropriate manner and suitable for following capacity of pairs, including Krone makemodules, crimping and terminations, etc. complete as required. a) 10 Pair |
| 291 | Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-45 connector (modular LAN socket TX1000/ CAT6) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required. a) Cat B |
| 292 | Supplying and fixing 1 m 24 AWG multi stranded UTP patch cord with RJ-45 factory crimped connector of Cat 6 type, compliant ANSI/TIA-568.2-D standards in position as per specification no. WG-ELVC/PC |
| 293 | Supplying and drawing of Cat - 6 UTP, 4 pair annealed tinned copper conductor PVC insulated, PVC sheathed, unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection, etc. complete as required (a) Cat 6 |
| 294 | Supplying, fixing, and configuring 24 ports, PoE switch compliant with IEEE 802.3 standards with min. 193W PoE capacity with 4GE SFP uplink in provided rack as per specification no. WG-NWC/ENS |
| 295 | Supplying, installing, testing & commissioning of 16/20 Ch Network Video Recorder (NVR), suitable for 2 MP cameras only with HDMI/VGA outputs provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 160Mbps with minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10 /100/1000 Mbps selfadaptive Ethernet interface, support multi brand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified. duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications no. CCTV-NVR |
| 296 | Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor : minimum 1/2.8\\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM |
| 297 | Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following features Image Sensor : minimum 1/2.8\\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129° 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102° 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM. |
| 298 | Supplying & erecting 32\\" professional LED Monitor with 1920*1080 (Full HD) Display, suitable for 16 channel NVR and following features Brightness: minimum 250 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC, USB, Audio In, Built-in speakers maximum 2 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 299 | Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 300 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x550x347 mm) as per specification No. WG-NAS/RAK |
| 301 | Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 16 universal extensions compliant to IEC 61000, EN 60950, CISPR 22, IS:9000 part 2/section 4 having LAN/WAN Port, USB port, RS232 port as per specification complete as per specification no. WG-TA |
| 302 | Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). |
| 303 | Providing & erecting 5 m high (clear height) alvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL. |
| 304 | Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP |
| 305 | Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6 m in length along with pole cap of 300mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC |
| 306 | Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/SL. |
| 307 | Supplying, erecting, testing & commissioning of 3 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. APUPS (Without batteries) |
| 308 | Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete |
| 309 | Supply, Fabrication, Erection, Testing & Commissioning of Main Panel floor mounted with frame of suitable M.S. channel dully painted, fabricated of 14/16 swg CRCA sheets completely derusted, chemically treated and powder coated with shade suggested by client and having following items as per single line diagram:- 1250A, 4P, ACB - 1 no. wired to 25A, TP, MCB - 1 no which is further wired for ammeter having Three & half digit LED display, external C.T. operated, calibrated for suitable to operate on 500V, 0 to1000A AC supply, L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio with 15VA, 3 pilot lamps all Bakelite with colour glasses with miniature lamps 230 V/250V from GED connected to 800A, 4P alluminium busbar. one side of busbar connected to 2nos of 125A, TP, MCCB. 1 no of 125A, TP, MCCB with 100 KVAR Capacitor bank and second side of busbar connected to 800A, 4P, change over switch. Other side of COS is connected to 1250A, 4P, ACB - 1 no. wired for ammeter having Three & half digit LED display, external C.T. operated, calibrated for suitable to operate on 500V, 0 to1000A AC supply, L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio with 15VA, 3 pilot lamps all Bakelite with colour glasses with miniature lamps 230 V/250V from DG with outgoing of 6 nos 125A, TP, MCCB, 1 no 400A, 35/40KA, TP, MCCB and 21 nos 63A, TP, MCB as per single line drawing of MLTP |
| 310 | Supplying, installing, testing & commissioning compact substation with 3 phase, 11/0.433 kV, 50 Hz., 1000 kVA, Mineral oil immersed Copper wound, without gas cushioning, hermetically Sealed transformer having indoor type transformer bushings, with HT side (incoming side) Circuit Breaker of appropriate rating & capacity and LT side (outgoing side) MCCBs (4 pole) of appropriate capacity, with inbuilt metering cubical having 3 epoxy coated CT's with CT Ratio ......./5 A, 10 or 15VA Burden, 0.5S Accuracy Class, & 3 epoxy coated PT's with PT Ratio 11/0.110KV, 10 or 15 VA Burden, 0.5S Accuracy Class properly arranged in standard MSEDCL approved enclosure, using type A winding insulation (kraft paper),standard accessories complete with test certificate with losses below 2790 Watts at 50% load, 7700 Watts at 100% load for transformer, as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspectors, as per specification no SS-TR-CS |
| 311 | Supplying, erecting, testing and commissioning 11KV HT metering cubicle (compact/vertical type) approved by licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos CT having required ratio between 50/5A to 200/5A, VA10 or 15, Class 0.2S, epoxy casted 3 nos PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation as per specification no. CP-HT. |
| 312 | Supply of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screned with extruded semiconducting compound in combination with copper tape(0.3 KA for 1Sec.) cores laid off,inner sheath of PVC tape,galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments. 3 Core 70 sq.mm |
| 313 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV grade of size not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. |
| 314 | Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required.(b) 11 KV, 3 Core x 50 - 95 sq.mm |
| 315 | Supplying and making Outdoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed/XLPE aluminium conductor cable upto 11 KV grade, complete as required. (b) 11 KV, 3 Core x 50 - 95 sq.mm |
| 316 | Providing & Fixing of printed instruction chart for (with minimum 700 x 1000 mm in size) treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete |
| 317 | Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete |
| 318 | Supplying and fixing standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, antiseptic solution, etc. (All above contents shall be of standard makes) |
| 319 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness upto 3.3 kV |
| 320 | Supplying and erecting fencing of section having size at least 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete with provided earthing as per specification no. SS-AS/FSG |
| 321 | Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2.45m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete. |
| 322 | Supplying and erecting double leaf hinged door each 1500 mm in width x 2450 mm in height using B class GI pipe, hinges and angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation and painted complete as per specification no SS-AS/DLD |
| 323 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 750 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2/G3 and maximum fuel consumption 126.4 ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 990 ltr etc., on provided M20 grade CC foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG |
| 324 | Supplying & erecting testing and commissioning of Minimum three & above star rated Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 1.5 kW/2 HP with discharge 600/140 Litres per Minute (LPM) for head of 8/22 m & 50 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP |
| 325 | Supplying & erecting testing and commissioning of automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. |
| 326 | FIREFIGHTING WORKS |
| 327 | Supplying, installation, testing and commissioning of main fire pump (MFP /EP) suitable for water discharge of 1800 to 2280 LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 37kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP |
| 328 | Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP |
| 329 | Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of firered colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP |
| 330 | Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP |
| 331 | Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (2 working+2 standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications, the capacity of electric motor driven pump are as followsa. Main fire pump (MFP) having capacity of 37kW 2 nos (1 working + 1 standby, alternate run per per start in auto mode)b. Jockey pump (JP) capacity of suitable capacity 2 nos (1 working +1 standby, alternate run per per start in auto mode) c. Booster Pump (BP) capacity of 5.50 kW 1 no comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc.3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating.4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps.7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications.9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge.10. Danger board as per IS.11. Spare HRC fuses minimum 2 nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1 working + 1 standby, alternate run per start in auto mode), JP = (1 working +1 standby, alternate run per start in auto mode), Booster pump complete panel, as per specification no. FF-MFP/ECP 12. The control for diesel engine comprises of automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low Lub. oil pressure, high water temp and engine on indication battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC voltmeter, and 0-20 A DC ammeter with all standard relays and accessories required for automatic operation of diesel engine with interlocking for operation of main fire pumps |
| 332 | Supplying and erecting G.I. pipe 'C' class ERW (Electrical Resistance Welding) 20 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 333 | Supplying and erecting G.I. pipe 'C' class ERW (Electrical Resistance Welding) 25 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 334 | Supplying and erecting G.I. pipe 'C' class ERW (Electrical Resistance Welding) 32 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 335 | Supplying and erecting G.I. pipe 'C' class ERW (Electrical Resistance Welding) 40 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 336 | Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification No. FF-PP |
| 337 | Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification No. FF-PP |
| 338 | Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification No. FF-PP |
| 339 | Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification No. FF-PP |
| 340 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification No. FF-PP |
| 341 | Providing coating of Bitumen Paint & pipeline corrosion resistant Pypkote tape conforming to IS 10221 Appendix B specification having 4mm thick Wrapping for underground 100 mm Ring Main of Fire Fighting System.(Pypkote tape comprises of a Tar based Polymeric mix supported on a fabric of high tensile strength Fibreglass). |
| 342 | Providing coating of Bitumen Paint & pipeline corrosion resistant Pypkote tape conforming to IS 10221 Appendix B specification having 4mm thick Wrapping for underground 150 mm Ring Main of Fire Fighting System.(Pypkote tape comprises of a Tar based Polymeric mix supported on a fabric of high tensile strength Fibreglass). |
| 343 | Supplying and erecting 80 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 344 | Supplying and erecting 100 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 345 | Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV |
| 346 | Supplying and erecting 75/80 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS |
| 347 | Supplying and erecting 100 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, for positive suction complete as per specification no. FF-VL/ELS |
| 348 | Supplying and erecting 150 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, for positive suction complete as per specification no. FF-VL/ELS |
| 349 | Supplying and erecting 75/80 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 350 | Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 351 | Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV |
| 352 | Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 353 | Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 354 | Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV |
| 355 | Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 356 | Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 357 | Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV |
| 358 | Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 359 | Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV |
| 360 | Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV |
| 361 | Supplying and erecting 25 mm Ball Valve complete with PN16 pressure rating, as per specification no. FF-VL/BV |
| 362 | Supplying and erecting 50 mm Ball Valve complete with PN16 pressure rating, as per specification no. FF-VL/BV |
| 363 | Supplying and installing one piece moulded HDP/ fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT |
| 364 | Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30 meter long high pressure polypropylene (Polyhose) along with necessary accessories complete. As per specification no. FF-FFA/HV |
| 365 | Supplying and erecting 63mm dia, Reinforced Rubber lined (R.R.L.) Hose pipe, 15 m in length, fitted with necessary accessories complete as pre specification no. FF-FFA/RRL |
| 366 | Supplying & erecting Stainless steel branch pipe of 63 mm dia. Fitted with 20mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ |
| 367 | Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC |
| 368 | Supplying and erecting fire brigade header (siamese connection) of 150 mm dia for supplying water in fire tank complete as per specification no. FF-FFA/SMC |
| 369 | Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT |
| 370 | Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV |
| 371 | Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG |
| 372 | Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS |
| 373 | Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade/ SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8\\"x6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003). |
| 374 | Supplying and erecting M.S./CRCA cabinet for housing double hose pipe with nozzle (size 750 x 600x 250 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\\"x6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) |
| 375 | Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 4 loop capacity and capable of supporting not less than 250 devices and detectors per loop, with on-board LCD alphanumeric backlit display suitable for minimum 80 characters, operating at 230 V 50 Hz - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 minutes in alarm condition, The panel shall have suitable provision for network connectivity & compatible for third party integration(Open Protocol to communicate) via a MODBUS/BACNET interface etc. conforming to IS 15908:2021, IS 2189: 2008, NFPA-72, EN 54 / VdS/FM & UL 864(10th edition) with 3 years replacement warranty and inclusive of lifetime software license validity , as per specification noFF-AFAS/CP. |
| 376 | Supplying, installing, testing and commissioning of Addressable Optical Photo Smoke Detector. The detector shall have multi co-operative sensing technology for faster response & avoid false alarms. The detector shall have single/twin bicolour LED for 360 deg viewing. The detector is conforming to IS 2189: 2008, 11360_1985_Reff2020_EN 54 /VdS / UL & FM approved with 3 years equipment replacement warranty, Designed to meet UL268, 7th Edition. FFAFAS/SD. |
| 377 | Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with 0°C to 58°C temperature range, with base as required, single/twin LED’s with 360 degree view, in-built locking mechanism to check the removal and pilferage of the detector, Detector Shall conforming to IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 / EN 54 / VdS / UL & FM approved with 3 years equipment replacement warranty, Designed to meet UL268, 7th Edition. FF-AFAS/HD - ROR. |
| 378 | Supplying, installing, testing and commissioning of addressable fire isolator module for isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health statusof the device. module complete as required. Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982, , EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, FF-AFAS/ISM |
| 379 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 /VdS or UL & FM approved with 3 years equipment replacement warranty as per specification no FF-AFAS/MCP. |
| 380 | Supplying, installing, testing and commissioning of addressable Sounder cum strobe rated at minimum 75 dB @ 3m for Audible annunciation and minimum 75cd flashing at 1 Hz for visual indication.Module shall conforming to IS 2189: 2008, IS 15908:2021 / EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty as per specification no FF-AFAS/S-ST. |
| 381 | Supplying, erecting, testing and commissioning of Upright/ Pendent quartzoid bulb sprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR./UP |
| 382 | Supplying, erecting, testing and commissioning of horizontal sidewall quartzoid bulb sprinkler, 15 mm (½\\") dia quartzoid bulb. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR/SS |
| 383 | Supplying, erecting, testing and commissioning vane type water flow detector 75/80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3)Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. as per specification no. FFSPR/WFD |
| 384 | Supplying and fixing of self expanding, ready to use polyurethane(PU) foam sealant of minimum 750ml bottle, suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles (except hollow core conductors). Sealant shall have minimum 2 hour fire rating, conforming to EN 1366-4:2021 as per specification no FF-FRS. |
| 385 | Supplying and fixing standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes) |
| 386 | Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 –2006 having 2 mm thickness upto 3.3 kV |
| 387 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. Capacity Cartridge type conform To IS 2878/ 15683 Complete erected with necessary clamp made front 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete. |
| 388 | Supplying erecting, testing and commissioning of Direct Low Pressure (DLP), automatic electrical cabinet fire suppression system kit comprises of the mild steel cylinder, hydraulic tested to 30kg /cm2 to check for leakages & burst pressure above 110kg/cm2. duly hot phosphate & epoxy powder coated internally and externally more than 65 microns or painted with 1 coat of primer and 2 coats of red enamel paint all complete. The Cylinder assembly is filled with 1kg to 1.13kgs of clean agent gas (FK-5-1-12 UL listed) and pre-pressurized to 15/16 Bar having storage & operating temperature range of (-) 17.8 deg.C to 54.4deg.C with all important accessories e.g. brass assembly valve with pressure gauge, end of line plug with pressure gauge suitable to connect with provided Linear heat detection tube complete with mounting bracket assembly, required size rubber grommets, plastic loop clamps, pressure switch and caution & cylinder Labels etc. |
| 389 | Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 390 | Supplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/ recess(heavy) including cutting the wall and making good the same in case of recessed conduit as required. - 25 mm Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
| 9 | Click here to download tender document | Tender Documents |
| 10 | Click here to download tender document | Tender Documents |
| 11 | Click here to download tender document | Tender Documents |
| 12 | Click here to download tender document | Tender Documents |
| 13 | Click here to download tender document | Tender Documents |
| 14 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail