| 1 | Providing & fitting fixing of 13/16\\" size retainer bush as per dept. sample. |
| 2 | Providing and fixing MS bolts including nuts and washers complete as per standard design:- a) upto 300mm Length |
| 3 | Making, Supplying and Fitting Fixing of MS Spindles In/C Socket for Sluice Valve as per Departmental Sample. |
| 4 | a)16\\" Dia |
| 5 | b) 8\\" Dia |
| 6 | e) 6\\" Dia |
| 7 | Periodical Servicing of Mechanical accessories by providing & fiiting fixing 10/12 mm gland packing (best quality) |
| 8 | Providing and fitting fixing PVC suction hose pipes of wall thickness 6 mm as per relevant IS specification and direction of the Engineer-in -charge. i) 150 mm |
| 9 | Repairing of Line Shaft/Top Shaft of different capacity of VT Pump by welding, Grinding, Threading centering as per direction of the Engineer-in-Charge. |
| 10 | Cleaning of the Sedimentation tank & Clarifloculator by manual means as per direction of the Engineer-in-Charge |
| 11 | Cleaning of all other chamber Except Clarifloculator(Filter Bed/ Aeriator/ Clear water Chamber/ Lime & alum Chamber) |
| 12 | Cleaning of deposited sand, clay from the intake well inside/Outside with the help of setting by operating Diesel Engine Pump, boat, manual labour necessary staging etc. Complete |
| 13 | Charges for lifting of pump, motor, column pipe etc. from intake well and stacking the same at suitable place as per specification and the direction of the Engineer-in-charge. |
| 14 | Providing and placing gunny/ polythene (of minimum wall thickness of 500 micron) bags filled with sand (of minimum qty of 0.034 cum) and properly manually stitched to avoid any leakage of sand as per specification. |
| 15 | Single bamboo palasiding/walling of whole 2nd class bamboo (Jati or Bethua) 65 to 75 mm dia and closely packed & driven @ 150 mm c/c including fitting fixing with half bamboo kamis horizontally in three rows with cane or tying with wire complete and struts 1.5 m apart longitudinally and providing bitumen drum sheet walling fixed with nails as per drawing and MoRD technical specification Clause 1302.5.A) Driven at least 900 mm below ground and 1200 mm above ground on average |
| 16 | Providing and fitting, fixing bamboo (1st class) 85 mm to 100 mm dia for horizontal, diagonal bracing, strut etc. with nails / spikes and binding wire (GI 2.00 mm) as per drawing and specification. |
| 17 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 18 | Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 19 | Providing and fitting fixing of pressure meter ( 0.0 - 14.0 Kg/ sqcm.) as per specification and as per specification and the direction of the Engineer - in-charge. |
| 20 | Periodical Servicing of Mechanical accessories by Supplying of grease (all purpose) and mtc properly as per direction of engineer in charge |
| 21 | Providing Fitting fixing of Gun Metal Make 30mm internal dia Gland Plate/Gland Fit for 50,000/62,500GPH VT Pump as per departmental Smaple |
| 22 | Providing Fitting fixing of Gun Metal Make 30 In Dia x 65mm Gland bush for 50,000/62,500GPH VT Pump as per departmental Smaple |
| 23 | Charges for lifting of pump, motor, column pipe etc. From intake well and stacking the same at suitable place as per specification and the direction of the Engineer-in-charge. |
| 24 | Labour charge for fitting fixing and lowering of submersible pump motor with delivery assembly 90 to 0 digree in/c fitting fixing with the delivery line etc. asper direction of the engineer in-charge. |
| 25 | Providing and fitting fixing of Contractor Coil, without With out Kit (230/440 V) |
| 26 | a) MNX-110 type. (L&T Make) |
| 27 | b) ML-2 type. (L&T Make) |
| 28 | c) ML-6 type. (L&T Make) |
| 29 | Providing and fitting fixing of spare contact kits without Coil (L & T make) for Auto Star Delta Starter. |
| 30 | a) MNX-110 type. |
| 31 | b) ML-2 type. |
| 32 | c) ML-6 type. |
| 33 | Supplying and fitting fixing Electronic Timer Type ST-100 (L & T make) suitable for 240/300/415V, 50 Hz having ranges for 3-30 Secs/12-120 secs. |
| 34 | Providing & supplying of Kit-Kat Rewireable Porcelain Fuse (Cut-Out) carrier & base of Havell's made (Delux Quality).a) 100 Amps/415 Volt |
| 35 | Supplying and fitting fixing of Thermal Timer Type GT-200 (L & T make) suitable for 230/250V, 360V, 400/440V, 50 Hz for 5-18 Secs. |
| 36 | Supplying and fitting fixing of Citation-M Overload Relays (direct mounting with built in single phase protection) having relay range of BCH made. |
| 37 | a) CT Operated Overload relay (90-150/60-100) (L&T Make) |
| 38 | b) ML Relay 20-32 Amps (L&T Make) |
| 39 | Providing and fitting fixing heavy duty box type (Resin filled) power factor correction capacitor L & T make etc. complete as per specification and direction of the Engineer-in-charge.i) 20-50 kVAr 440 V |
| 40 | Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge. |
| 41 | Providing and fitting fixing of moving iron type, Range 0-100/0-200 Amp, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineerin-charge. |
| 42 | Providing & fitting fixing with PVC insulated single core multistring Copper cable confirming to IS 694 for inter connection with all electrical equipment of the panel board as specification and direction of the Engineer - in - charge. |
| 43 | i) 16.sqmm. |
| 44 | ii) 25.sqmm. |
| 45 | ii) 50.sqmm. |
| 46 | Providing and fitting fixing steel sheet enclosed switch fuse unit (suitable for DIN fuses), triple pole with Neutral Link(TPN), 415/500 Volt, L & T / Havells / BCH make etc.complete as per specification and direction of the Engineer-in-charge.i) 63 amps |
| 47 | Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge.i) 50 HP/37 kw Relay range within 28-42 + 10% Please Enable Macros to View BoQ information |