Drinking Water Supply and Sanitation Government Departments Closing in 3 days TDR #55459766

Tender For Canal Water Based Water Supply Project For Construction Of 5.0 Mld Water Treatment Plant (Wtp) And Other Related Works Including 5 Years Operation And Maintenance (Part-2) At Mallanwala Khass, District : Ferozepur, Punjab Under Amrut 2.0 S

Issued by Government Departments · Ferozepur, Punjab
Tender Value
16.94 Crore
Estimated cost
Bid Submission
08 Jul 2026
3 days left
EMD
16.94 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ferozepur → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Canal Water Based Water Supply Project For Construction Of 5.0 Mld Water Treatment Plant (Wtp) And Other Related Works Including 5 Years Operation And Maintenance (Part-2) At Mallanwala Khass, District : Ferozepur, Punjab Under Amrut 2.0 Scheme

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Jun-2026 Corrigendum Date 30-Jun-2026
2 10-Jun-2026 Extension of Date Date 23-Jun-2026
3 10-Jun-2026 Extension of Date Date 23-Jun-2026
4 30-Jun-2026 Corrigendum 2 Date 08-Jul-2026

BOQ

Name of Work:- Canal Water Based Water Supply Project for Construction of 5.0 MLD Water Treatment Plant (WTP) and other related works including 5 years Operation and Maintenance (Part-2) at Mallanwala Khass, District : Ferozepur, Punjab under AMRUT 2.0 Scheme
Sl. No. Item Description
1NIT No.: Date: STANDARD BIDDING DOCUMENT FOR PROCUREMENT OF WORKS Canal Water Based Water Supply Project for Construction of 5.0 MLD Water Treatment Plant (WTP) and other related works including 5 years’ Operation and Maintenance (Part-2) at Mallanwala Khass, District : Ferozepur, Punjab under AMRUT 2.0 Scheme Volume - 3 Project Value: Capital cost: Rs. 1518.16 Lakh 5 Years' O&M: Rs. 176.32 Lakh Price Bid May, 2026 NIT No.: Date: Name of Work: Canal Water Based Water Supply Project for Construction of 5.0 MLD Water Treatment Plant (WTP) and other related works including 5 years’ Operation and Maintenance (Part-2) at Mallanwala Khass, District : Ferozepur, Punjab under AMRUT 2.0 Scheme Name of Bidder:
2Construction of 5.0 MLD Water Treatment Plant (WTP) and other related works Part-2
35 Years' Operation and Maintenance of WTP and other related components of Part 2. Estimate Amount (1 +2 ) (In Rs): 169448627.36 Enter Rate below without (+), (-) and (%) symbols For \\"At Par\\" Rate, Enter Zero. 1694.4862736000002 Percentage Above/Below/At Par Select % Amount as per percentage quoted, Percentage Rate (1+2) (Amount in Rs) 0.0 Amount In Words No Rupees and No Paise Provisional Sum (Not part of bidding) Rs in Lakh = 474.3531724879758 2168.8394460879763 Name of Work: Canal Water Based Water Supply Project for Construction of 5.0 MLD Water Treatment Plant (WTP) and other related works including 5 years’ Operation and Maintenance (Part-2) at Mallanwala Khass, District : Ferozepur, Punjab under AMRUT 2.0 Scheme Details Summary WTP Part-2 S.No Particulars Total Amount (Rs) Capital Works: Percentage Rate I ) Civil works :
4Canal Intake : i) RCC Valve Chamber near Canal 300726.0 ii) Rising main from Canal to Concrete Channel 229526.0 iii) Raw Water Concrete Channel 465620.0 iv) RWR Intake Well & Pumping machinery room, Panel room and Meter room 2611032.0 v) Boundary wall with Wire fencing at Intake Pumping Station 487134.0
5Raw Water Transmission main : i) Raw water transmission main : DI K-7: 1080 m 8719789.0 ii) Crossing 7294.0
6Raw water S & S Tank : i) Raw Water Storage and Sedimentation (S &S ) Tank with Ramp 25616855.0 ii) Raw Water Inlet Chamber to S & S Tank - I 236118.0 iii) Raw Water Inlet Chamber to S & S Tank - II 197275.0 iv) Raw Water Outlet Valve Chamber 350005.0 v) Construction of supporting RCC columns for Solar Panel 1661759.0
7Raw water sump and Pumping station : i) Raw water sump 1084234.0 ii) Pumping machinery,Panel room & Store room 1149735.0
8Water Treatment Plant : i) Capacity : 5 MLD (22 Hrs @227.08 KLH) 23004130.0
9Chlorine Contact tank : i) Chlorine Mixing Chamber 394130.0 ii) Valve Chamber 432033.0 iii) Chlorine Contact tank 1463042.0
10Clear Water Reservoir : ( CWR ) i) Clear Water Reservoir with Compartment 6830016.0 ii) CWR Sump and Pumping station,Panel Room : 1351121.0
11Clear Water Transmission Main : DI K-7, i) Clear water transmission main : DI K-7: 8379 m 37975860.0 ii) Minor Crossing 7294.0 iii) National / State Highway crossing (Thrusting/ Trenchless) 2705850.0
12Distribution line within WTP premises ( DI K-7 100 mm.i/d, L =80 m) and uPVC 40 mm.i/d. Length =100.0m
13WTP Boundary wall = 650m A PART A : ( Rs.Lakh) Civil works +WTP 121855461.0 II ) Mechanical Works :
14Raw water pump : Intake well to S & S Reservoir
15Raw water pump :S&S Reservoir to WTP
16Dewatering Pumps: In S&S Reservoir
17Clear water pump : Clear water Reservoir to OHSR B PART B : ( Rs.Lakh) Mechanical works 13550156.9961025 III ) Electrical,Instrumentation & SCADA works :
18Intake Pumping Station
19Raw Water Pumping Station
20Clear Water Pumping Station
21Sub-Station for Raw & Clear water Pumping Station and WTP
22SCADA for Intake, Raw Water & Clear Water Pumping Station, WTP & Sub-Station C PART C : ( Rs.Lakh) Electrical, Instrumentation & SCADA Works 16410609.0 Estimate Amount (Part A, B & C,) (In Rs): 151816226.9961025
23PART D : 5 Years' Operation and Maintenance E Provisional Sum (Not part of bidding) Rs. In Lakh a Provisional Sum (Capital Cost) Rs in Lakhs : 323.751282395112 b PWSSB Charges and Cess,Rs in Lakhs : 150.6018900928638 Total Provisional Cost Rs in Lakhs (Not part of bidding) 474.3531724879758 Part-2: Canal Water Based Water Supply Project for Construction of 5.0 MLD Water Treatment Plant (WTP) and other related works including 5 years’ Operation and Maintenance (Part-2) at Mallanwala Khass, District : Ferozepur, Punjab under AMRUT 2.0 Scheme Provisional Sum S.no. Description Unit Qty Cost (Rs in Lakh) (A) Provisional Sum (Capital Cost) :
24Price Escalation = 3.75 % of Capital Cost ( @ 7.50 % per annum and average 3.75% per year)
25Contingencies on Capital Cost
26Permission & execution / BT Bill of Railway
27Permission / BT Bill of National Highway (10m CWR) National Highway (NH) : Bank Guarantee = 2.20 LakhsLicense fee = 1.20 LakhsLS = 1.60 Lakh
28Permission / BT Bill of B & R deposit/Nallah crossing: (8379m CWR) +(1150m RWR)B&R Road Cutting & Restoration: KC: at Rs.300 / sqm : 9529x1.25 = 11911.25 sqm=Rs.35.73 Lakh
29Shifting of Utilities ( Electric Poles,W/S.and Sewerage Pipeline,Other Service Utilities) Permission / BT Bill of Forest dept. 10.0
30Permission / BT Bill of Mandi Board. BT Type Road Irrigation Deposit work Charges for providing Raw Water and Construction of Cross regulator if there is no existing cross regulator (01 no. Canal crossing) 40.0
31Electrical connections charges : a Intake Pumping station 2.98853 b Sub Station 14.93438 Sub Total (A) Provisional Sum 323.751282395112
32(B) PWSSB Charges and Cess : a Contingencies Charges on work @ 1% ( To be paid on actual limited to maximum @ 1% of Capital cost) 0.01 15.181642146458046 b PWSSB Charges @ 6 % on Capital Cost 0.06 91.08985287874827 c Third Party Inspection Charges @ 0.92% 0.0092 13.967110774741402
33Cess : a Culture Cess @ 1% ( For works more than 15 Crore on PWSSB works and Nil for Local Govt. works ) 1% 15.181642146458046 b Cancer Cess @ 1% ( For works more than 15 Crore) 1% 15.181642146458046 Sub Total (B) PWSSB Charges and Cess 150.6018900928638 Total : Provisional Sum (A+B) (Not part of bidding) 474.3531724879758 RCC Valve Chamber near Canal Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Earthwork in excavation : 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
34i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a) Extra depth excavation : > 1.50 m.
356.19 Rate for loading : 4.1 (A ) Stone (building or pitching),Sand,Earth,Fly Ash,Bajri,Shingle,Spalls,Brick bats,Brick ballast and Stone metal.
36 Carriage of Earth : 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
37 2 nd and 3 rd chain,per chain of 30 meters.
38 For subsequent chain per chain of 30 meters up to 0.50 km
39 CC 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
40ii M-30 :
4110.17 Shuttering :
429.1 C / shuttering :
439.2 C / shuttering :
449.8 Steel :
4518.18 PVC Foot Steps :
4629.35 RCC Manhole cover with frame : 29.34 Providing & fixing 560 mm.,500 mm and 450 mm.i/d.circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS : 12592 -2002,including carriage from the atores of the Engineer -in -charge to site of work,loading,unloading,including stacking and setting the same to correct lines over manholes,including cement concrete copping ( M-20) around the frameetc.Dia. of steel for lifting hook is 16 mm.( for EHD and HD) A RCC Man hole cover with frame a 560 mm.i/d.RCC Man hole cover with frame as per ISI
47ii Sluice Valve : 28.27 Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronge (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing,testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d)
48(f ) D / F Pipe : 28.23 Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged Pipes with screwed,flanged as per IS : 8329 - 2000,Class K -9 and laying the same in trenches to correct alingnment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage. Pipe lines laid complete. mm.i/d.
49g GI Pipe : ( Rising pipe for Valve Operation) 28.35 Providing,laying,jointing,fixing and testing ISI Marked G.I.Pipe ( as per IS 1239 ) B -Class,including cost of specials ( such as tees,bends,sockets,elbows,etc.) painting with anti corrosive bitumastic paint,testing,cutting,threading Inside building complete. mm.i/d.
50b Diff.in Rates of Materials :
51 From Mirthal 180 km
52 From Lohand Khad 220 km
53 Carriage of Materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
54 From Mirthal 180 km
55 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 229830.0 0.0535 12296.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 242126.0 1.Capital Works ' NON CSR based Items CI-D Joint : NSRUIDP SOR 2022-23Code No. 19.56 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. 19.56.7 300 mm dia PN-1.0 Each 2.0 11900.0 Eleven Thousand Nine Hundred Rupees and No Paise 23800.0 Puddle Collar : NSRUIDP SOR 2022-23Code No. 19.63 Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specifications and as per direction of Engineer
5619.63.7 Capital Works ' NON CSR based Items ( In Rs) 58600.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 242126.0 Non - CSR based amount ( In Rs) 58600.0 Total : CSR + Non CSR Amount : ( Rs) 300726.0 Rising Main up to Raw Water Channal Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Earthwork in excavation : Excavation : ( Manually) 28.1 Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. (a) Earthwork upto 1.50 mt.Depth.
57i Excavation : (Mech.) 28.2 Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. (a) Earthwork upto 1.50 mt.Depth.
58i DI K-7 Pipes : 28.7 B Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage,cost of rubber ring. A DI pipe as per IS 8329 DI-K7
59(f) DI Specials : 28.25 Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.
60a Capital Works ' CSR based Items ( In Rs) 217870.0 0.0535 11656.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 229526.0 Total : CSR Amount : ( Rs) 229526.0 Rising Main up to Raw Water Channal Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Excavation : 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 16 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
61i Extra depth : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a) Extra depth excavation :
626.19 Loading :
634.1 ( A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
64 2 nd and 3 rd chain,per chain of 30 meters
65 For subsequent chain per chain of 30 meters up to 0.50 km
66 CC.1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
67ii M-30 :
6810.17 M-30 : (>4.0 m) 10.49 Extra for RCC work done above 4 meters height (where any single storey exceeds 4 meters in height) for every additional height of 1 meters or thereof. > 4.0 mt.height Walls concrete : 4.0 - 5.0 m cum 1.2389999999999992 5743.0 Five Thousand Seven Hundred Forty Three Rupees and No Paise 7116.0 5.0 - 6.0 m cum 1.2389999999999992 5788.0 Five Thousand Seven Hundred Eighty Eight Rupees and No Paise 7171.0 Shuttering : ( Raft foundation)
699.1 C / shuttering : ( Walls)
709.2 Extra rate for shuttering :
719.16 C /shuttering : (Platform slab for operation of Manual screen)
729.8 Steel :
7318.18 Safety foot rest :
7429.35 MS Railing for Operation platform Bar screen :
7518.3 Sluice Valve : 28.27 Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronge (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing,testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d)
76(f ) D / F Pipe : 28.23 Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged Pipes with screwed,flanged as per IS : 8329 - 2000,Class K -9 and laying the same in trenches to correct alingnment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage. Pipe lines laid complete. mm.i/d.
77g GI Pipe : ( Rising Pipe for Valve Operation) 28.35 Providing,laying,jointing,fixing and testing ISI Marked G.I.Pipe ( as per IS 1239 ) B -Class,including cost of specials ( such as tees,bends,sockets,elbows,etc.) painting with anti corrosive bitumastic paint,testing,cutting,threading Inside building complete. mm.i/d.
78b Diff. Rates of materials :
79 From Mirthal 180 km
80 From Lohand Khad 220 km
81 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
82 From Mirthal 180 km
83 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 386350.0 0.0535 20670.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 407020.0 1.Capital Works ' NON CSR based Items CI-D Joint : NSRUIDP SOR 2022-23Code No. 19.56 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. 19.56.7 300 mm dia PN-1.0 Each 2.0 11900.0 Eleven Thousand Nine Hundred Rupees and No Paise 23800.0 Puddle Collar : NSRUIDP SOR 2022-23Code No. 19.63 Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specifications and as per direction of Engineer
8419.63.7 Capital Works ' NON CSR based Items ( In Rs) 58600.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 407020.0 Non - CSR based amount ( In Rs) 58600.0 Total : CSR + Non CSR Amount : ( Rs) 465620.0 RWR Intake well & Pumping Machinery room, Panel room & Meter room Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Earthwork excavation : 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
85i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a)
866.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
874.1 (A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
88 2 nd and 3 rd chain,per chain of 30 meters
89 For subsequent chain per chain of 30 meters up to 0.50 km
90 C.C. 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
91ii M-30 : Plinth level
9210.17 M-30 : Plinth level > 4.0 m 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof. M-30 : > 4.0 m
93 Shuttering : ( Raft foundation)
949.1 C / Shuttering : ( Walls)
959.2 C / Shuttering > 4.0 m.height : ( Walls) 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meterzs in height0 for every additional height of 1 metres or part thereof. sqm
96 C / Shuttering : (Columns)
979.4 C / Shuttering > 4.0 m.height : ( Columns) 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meterzs in height0 for every additional height of 1 metres or part thereof. sqm C / Shuttering > 4.0 m.height : ( Columns)
98 C / Shuttering : (Slab)
999.8 Steel :
10018.18 PVC Foot Steps :
10129.35 Note : PVC foot Steps are provided at ( 1+1=2) locations RCC Manhole cover with frame : 29.34 Providing & fixing 560 mm.,500 mm and 450 mm.i/d.circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS : 12592 -2002,including carriage from the atores of the Engineer -in -charge to site of work,loading,unloading,including stacking and setting the same to correct lines over manholes,including cement concrete copping ( M-20) around the frameetc.Dia. of steel for lifting hook is 16 mm.( for EHD and HD) A RCC Man hole cover with frame a 560 mm.i/d.RCC Man hole cover with frame as per ISI
102ii Diff.rates of materials :
103 From Mirthal 180 km
104 From Lohand Khad 220 km
105 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
106 From Mirthal 180 km
107 From Lohand Khad 220 km 1342114.0 Intake Pumping Station & Panel Combined 1413917.099 Brick masonary work (1:5) : ( H = 4.0 m)
10811.6 Brick masonary work (1:5) : ( above 4.0 m.height) ( 4.0 - 6.0 m ) 11.29 b Extra for work above 4 meters ( where any single storey exceeds 4 meters in height 0 for every additional height of 2 meters or part thereof for Brick Work / concrete Block / Clay Block
109 CC 1:2:4 : 10.13 Cement concrete 1:2:4 (a) with stone ballast or shingle
110ii DPC :
11110.26 M-30 :
11210.22 > 4.0 m M-30 : 10.22 Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixture as per IS : 1791 and vibrated by needle vibrator but excluding steel reinforcement,centering and shuttering in superstructure. Extra height Concrete : 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof.
113 Steel :
11418.18 C / Shuttering : (Columns)
1159.4 C / Shuttering > 4.0 m.height : ( Columns) 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height0 for every additional height of 1 metres or part thereof.
116 C/shuttering : 9.8 Centering and Shuttering for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc. : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meterzs in height0 for every additional height of 1 metres or part thereof. C / Shuttering > 4.0 m.height : 4.0 -5.0 m
117 C/shuttering : ( Lintels)
1189.6 CP 12.5 mm.thk. : (1:4)
11915.9 CP 12.5 mm.thk. : (1:2)
12015.7 Painting : White washing :
12116.3 Preparation of plastered surface :
12216.6 Distempering :
12316.7 Oil Bound Distemper :
12416.1 Earth filling under floors :
1256.8 / (a) / (ii) Ironite flooring:
12614.4 CC 1:4:8 Base for Ironite flooring: CC 1:4:8 : 10.11 Cement concrete 1:4:8 (a) with stone ballast 20 mm.gauge
127ii Steel windows and Ventilators : 18.2 Supplying openable steel windows of stanard rolled steel Z-sections, joints mitred and electrically flash welded with iron fittings including necessary iron handles,Peg-stay catchers,bolts,iron plugs and pressed steel projected hinges and glazing clips,complete ( Excluding glazing) and finished with two coats of ready mixed paint red lead non setting primer.
128(b) Fixing :
12918.23 Glass panes : 18.25 Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.
130(a) Doors Shutter : 17.17 (i) Kail wood doors shutter and window shutter panelled,galzed or glazed and panelled,including hinges,screws,chokes,cleats and cords etc. complete fixed in position.(Single Leaf)
131(a) Aluminium Fittings : 17.23 Cost of Aluminium fittings complete for doors,windows such as tower bolts,handles,Stoppers and screw etc.for these fittings.(Excluding sliding bolt)
132(ii) Steel Chowkats : 18.24 Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete.
133(c) Rolling Shutter :
13418.11 (a) Parapet Wall :
13511.36 CC 1:2:4 : ( Coping ) 10.13 Cement concrete 1:2:4 (a) with stone ballast or shingle
136ii CC gola :
13713.55 Top Khurra :
13813.45 Bottom Khurra :
13913.51 Drip Course :
14011.42 Dry Brick edge paving :
14114.18 CI Rain water pipes :
14213.41 CI head :
14313.42 CI shoes :
14413.43 Embedding of CI Rain water pipes :
14513.44 Meter Room Above GL Excavation : 6.7 Earthwork in excavation of foundations of bridges,culverts,building including handling of materials with combined lead of 15 metres dressing of bed and sides stacking the excavated soil clear from the edge of excavation and subsequent filling around
146(a) CC 1:2:4 : 10.13 Cement concrete 1:2:4 (a) With stone ballast or shingle
147ii M-30 : Plinth level
14810.17 Steel :
14918.18 Brick Masonary work in cm 1:5 : (plinth level)
15011.5 Difference rates of materials :
151 From Mirthal 180 km
152 From Lohand Khad 220 km
153 From Firozpur
154 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
155 From Mirthal 180 km
156 From Lohand Khad 220 km
157 Capital Works ' CSR based Items ( In Rs) 2478436.0 0.0535 132596.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 2611032.0 Total : CSR Amount : ( Rs) 2611032.0 Intake Boundary wall Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Excavation :
1586.19 CC 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
159ii M-30 :
16010.17 Steel :
16118.18 Shuttering :
1629.1 Back up Qty : C / shuttering : ( Columns)
1639.4 C / shuttering : ( Beams)
1649.6 115 mm.thk.BBM :
16511.36 CP 20 mm.thk. :
16615.2 White wash :
16716.3 Dry distemper :
16816.7 Sliding Shutters :
16918.9 Diff.in Rates of materials :
170 From Mirthal 180 km
171 From Lohand Khad 220 km
172 From Firozpur
173 Carriage of Materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
174 From Mirthal 180 km
175 From Lohand Khad 220 km
176 Capital Works ' CSR based Items ( In Rs) 444057.0 0.0535 23757.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 467814.0 1.Capital Works ' NON CSR based Items Barbed wire fencing : 1.2 Meter High G.I.Barbed Wire fencing
177NS (Rate analysis based on CSR item no.24.43 ) Capital Works ' NON CSR based Items ( In Rs) 19320.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 467814.0 Non - CSR based amount ( In Rs) 19320.0 Total : CSR + Non CSR Amount : ( Rs) 487134.0 Raw Water Transmission DI K7 Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Excavation : ( Manually) 28.1 Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. (a) Earthwork upto 1.50 mt.Depth.
178i Excavation : (Mech.) 28.2 Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. (a) Earthwork upto 1.50 mt.Depth.
179i DI K-7 Pipes : 28.7 B Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage,cost of rubber ring. A DI pipe as per IS 8329 DI-K7
180(f) DI Specials : 28.25 Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.
181a D / F Pipe : 28.23 Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged Pipes with screwed,flanged as per IS : 8329 - 2000,Class K -9 and laying the same in trenches to correct alingnment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage.
182g Scour Valve : 28.27 Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronge (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing,testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d)
183(b ) Valve chambers : 28.66 Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
184a Diff.rates of materials :
185 From Mirthal 180 km
186 From Lohand Khad 220 km
187 From Firozpur
188 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
189 From Mirthal 180 km
190 From Lohand Khad 220 km
191 Bailing out of water : 28.49 Bailing out water from the trenches for making new connections in existing pipe lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge.
192a Capital Works ' CSR based Items ( In Rs) 8239516.0 0.0535 440814.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 8680330.0 1.Capital Works ' NON CSR based Items Air Valve : NS Based on PHED Rajasthan 2023Code no.6.6 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide-HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material,labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 6.6.1 Class PN 1.0
1936.6.1.1 Capital Works ' NON CSR based Items ( In Rs) 39459.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 8680330.0 Non - CSR based amount ( In Rs) 39459.0 Total : CSR + Non CSR Amount : ( Rs) 8719789.0 Crossing Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items 18.1 Steel work,fixed independentally without connecting plates, including cutting,hoisting and fixing in position.
19418.15
19516.17 Capital Works ' CSR based Items ( In Rs) 6924.0 0.0535 370.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 7294.0 Total : CSR Amount : ( Rs) 7294.0 Raw Water Storage and Sedimentation (S &S ) Tank with Ramp Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Earthwork excavation : 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
196i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a)
1976.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
1984.1 (A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
199 2 nd and 3 rd chain,per chain of 30 meters
200 For subsequent chain per chain of 30 meters up to 0.50 km
201 C.C. 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
202ii M-30 :
20310.17 M-30 : > 4.0 m 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof.
204 Shuttering : ( Raft foundation - S & S tank)
2059.1 C / Shuttering : ( Walls - S & S tank)
2069.2 C / Shuttering > 4.0 m.height : ( Walls - S & S tank) ( 4.0 - 5.0 m) 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height for every additional height of 1 metres or part thereof.
207 Steel :
20818.18 PVC Foot Steps :
20929.35 RAMP CONSTRUCTION : C / Shuttering : (Columns - Ramp)
210 C / Shuttering : (Columns - Ramp)
2119.4 C / Shuttering : (Beam)
2129.6 C / Shuttering : (Slab - Ramp)
2139.8 Back up Qty. Sliding Shutters : ( At Ramp Approach)
21418.9 Difference in Rates of materials :
215 From Mirthal 180 km
216 From Lohand Khad 220 km
217 Carriage of Materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
218 From Mirthal 180 km
219 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 24315952.0 0.0535 1300903.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 25616855.0 Total : CSR Amount : ( Rs) 25616855.0 Raw Water Inlet Chamber to S & S Tank-I Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Earthwork in excavation : (Mechanically) 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 16 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
220i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a)
2216.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
2224.1 (A) C.C. 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
223ii M-30 : (plinth)
22410.17 Shuttering :
2259.1 C / Shuttering : ( walls)
2269.2 C / Shuttering : ( slab)
2279.8 Steel :
22818.18 PVC Foot Steps :
22929.35 RCC Manhole cover with frame : 29.34 Providing & fixing 560 mm.,500 mm and 450 mm.i/d.circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS : 12592 -2002,including carriage from the atores of the Engineer -in -charge to site of work,loading,unloading,including stacking and setting the same to correct lines over manholes,including cement concrete copping ( M-20) around the frameetc.Dia. of steel for lifting hook is 16 mm.( for EHD and HD) A RCC Man hole cover with frame a 560 mm.i/d.RCC Man hole cover with frame as per ISI
230ii Sluice Valve : 28.27 Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronge (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing,testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d)
231(f ) D / F Pipe : 28.23 Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged Pipes with screwed,flanged as per IS : 8329 - 2000,Class K -9 and laying the same in trenches to correct alingnment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage. Pipe lines laid complete. mm.i/d.
232g GI Pipe : ( Rising Spindle for Valve Operation) 28.35 Providing,laying,jointing,fixing and testing ISI Marked G.I.Pipe ( as per IS 1239 ) B -Class,including cost of specials ( such as tees,bends,sockets,elbows,etc.) painting with anti corrosive bitumastic paint,testing,cutting,threading Inside building complete. mm.i/d.
233b Diff.rates of materials :
234 From Mirthal 180 km
235 From Lohand Khad 220 km
236 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
237 From Mirthal 180 km
238 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 168503.0 0.0535 9015.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 177518.0 1.Capital Works ' NON CSR based Items CI-D Joint : NSRUIDP SOR 2022-23Code No. 19.56 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
23919.56.7 Puddle Collar : NSRUIDP SOR 2022-23Code No. 19.63 Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specifications and as per direction of Engineer
24019.63.7 Capital Works ' NON CSR based Items ( In Rs) 58600.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 177518.0 Non - CSR based amount ( In Rs) 58600.0 Total : CSR + Non CSR Amount : ( Rs) 236118.0 Raw Water Inlet Chamber to S & S Tank-II Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Earthwork in excavation : (Mechanically) 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 16 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
241i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a)
2426.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
2434.1 (A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
244 2 nd and 3 rd chain,per chain of 30 meters
245 For subsequent chain per chain of 30 meters up to 0.50 km
246 C.C. 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
247ii M-30 : (plinth)
24810.17 Shuttering :
2499.1 C / Shuttering : ( walls)
2509.2 C / Shuttering : ( slab)
2519.8 Steel :
25218.18 PVC Foot Steps :
25329.35 RCC Manhole cover with frame : 29.34 Providing & fixing 560 mm.,500 mm and 450 mm.i/d.circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS : 12592 -2002,including carriage from the atores of the Engineer -in -charge to site of work,loading,unloading,including stacking and setting the same to correct lines over manholes,including cement concrete copping ( M-20) around the frameetc.Dia. of steel for lifting hook is 16 mm.( for EHD and HD) A RCC Man hole cover with frame a 560 mm.i/d.RCC Man hole cover with frame as per ISI
254ii Sluice Valve : 28.27 Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronge (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing,testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d)
255(f ) D / F Pipe : 28.23 Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged Pipes with screwed,flanged as per IS : 8329 - 2000,Class K -9 and laying the same in trenches to correct alingnment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage. Pipe lines laid complete. mm.i/d.
256g GI Pipe : ( Rising Spindle for Valve Operation) 28.35 Providing,laying,jointing,fixing and testing ISI Marked G.I.Pipe ( as per IS 1239 ) B -Class,including cost of specials ( such as tees,bends,sockets,elbows,etc.) painting with anti corrosive bitumastic paint,testing,cutting,threading Inside building complete. mm.i/d.
257b Diff.rates of materials :
258 From Mirthal 180 km
259 From Lohand Khad 220 km
260 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
261 From Mirthal 180 km
262 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 131633.0 0.0535 7042.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 138675.0 1.Capital Works ' NON CSR based Items CI-D Joint : NSRUIDP SOR 2022-23Code No. 19.56 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
26319.56.7 Puddle Collar : NSRUIDP SOR 2022-23Code No. 19.63 Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specifications and as per direction of Engineer
26419.63.7 Capital Works ' NON CSR based Items ( In Rs) 58600.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 138675.0 Non - CSR based amount ( In Rs) 58600.0 Total : CSR + Non CSR Amount : ( Rs) 197275.0 Raw Water Outlet Valve Chamber Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Earthwork in excavation : (Mechanically) 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 16 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
265i The excavation depth is coming only up to 2.45 m. Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a)
2666.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
2674.1 (A) C.C. 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
268ii M-30 :
26910.17 M-30 : > 4.0 m 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof.
270 Shuttering :
2719.1 C / Shuttering : ( walls)
2729.2 C / Shuttering > 4.0 m 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 meters or part thereof.
273 C / Shuttering : ( slab)
2749.8 Steel :
27518.18 PVC Foot Steps :
27629.35 RCC Manhole cover with frame : 29.34 Providing & fixing 560 mm.,500 mm and 450 mm.i/d.circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS : 12592 -2002,including carriage from the atores of the Engineer -in -charge to site of work,loading,unloading,including stacking and setting the same to correct lines over manholes,including cement concrete copping ( M-20) around the frameetc.Dia. of steel for lifting hook is 16 mm.( for EHD and HD) A RCC Man hole cover with frame a 560 mm.i/d.RCC Man hole cover with frame as per ISI
277ii Sluice Valve : 28.27 Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronge (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing,testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d)
278(f ) D / F Pipe : 28.23 Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged Pipes with screwed,flanged as per IS : 8329 - 2000,Class K -9 and laying the same in trenches to correct alingnment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage. Pipe lines laid complete. mm.i/d.
279g GI Pipe : ( Rising Spindle for Valve Operation) 28.35 Providing,laying,jointing,fixing and testing ISI Marked G.I.Pipe ( as per IS 1239 ) B -Class,including cost of specials ( such as tees,bends,sockets,elbows,etc.) painting with anti corrosive bitumastic paint,testing,cutting,threading Inside building complete. mm.i/d.
280b Diff.rates of materials :
281 From Mirthal 180 km
282 From Lohand Khad 220 km
283 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
284 From Mirthal 180 km
285 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 270532.0 0.0535 14473.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 285005.0 1.Capital Works ' NON CSR based Items CI-D Joint : NSRUIDP SOR 2022-23Code No. 19.56 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
28619.56.7 Puddle Collar : NSRUIDP SOR 2022-23Code No. 19.63 Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specifications and as per direction of Engineer
28719.63.7 Capital Works ' NON CSR based Items ( In Rs) 65000.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 285005.0 Non - CSR based amount ( In Rs) 65000.0 Total : CSR + Non CSR Amount : ( Rs) 350005.0 Columns of 300mm dia (Column Height 6m) for Solar Panel Sl. no. Reference Particulars of Items and details of works Unit Quantity Total Rate Rate ( Rs) in Words Amount (Rs) (Rs)
2882.0 M-30 :
28910.17 M-30 : > 4.0 m 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof.
290 C / Shuttering : ( Columns)
2919.5 C / Shuttering > 4.0 m.height : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height) for every additional height of 1 metres or part thereof.
292 Steel :
29318.18 Diff.rates of materials :
294 From Mirthal 180 km
295 From Lohand Khad 220 km
296 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
297 From Mirthal 180 km
298 From Lohand Khad 220 km Total amount : (Rs) 1577370.0 CSR items amount : (Rs) 1577370.0 Non CSR items amount : (Rs) 0.0 Add 5.35 % over CSR items amount : 0.0535 84389.0 G.Total amount : (CSR items amount + 5.35 % + Non-CSR items amount : (Rs) 1661759.0 RW Sump, Pumping Machinery Room, Panel Room & Store Room Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items RW Sump Earthwork excavation : 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
299i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a)
3006.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
3014.1 (A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
302 2 nd and 3 rd chain,per chain of 30 meters
303 For subsequent chain per chain of 30 meters up to 0.50 km
30410.13 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
305ii M-30 : Plinth level
30610.17 M-30 : Plinth level > 4.0 m 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof. > 4.0 m
307 Shuttering : ( Raft foundation)
3089.1 C / Shuttering : ( Walls)
3099.2 C / Shuttering > 4.0 m.height : ( Walls) 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meterzs in height0 for every additional height of 1 metres or part thereof. C / Shuttering > 4.0 m.height : ( Walls)
310 C / Shuttering : (Columns)
3119.4 C / Shuttering > 4.0 m.height : ( Columns) 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meterzs in height0 for every additional height of 1 metres or part thereof. sqm
312 C / Shuttering : (Slab)
3139.8 Steel :
31418.18 PVC Foot Steps :
31529.35 Note : PVC foot Steps are provided at 2 locations RCC Manhole cover with frame : 29.34 Providing & fixing 560 mm.,500 mm and 450 mm.i/d.circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS : 12592 -2002,including carriage from the atores of the Engineer in charge to site of work,loading,unloading,including stacking and setting the same to correct lines over manholes,including cement concrete copping ( M-20) around the frameetc.Dia. of steel for lifting hook is 16 mm.( for EHD and HD) A RCC Man hole cover with frame a 560 mm.i/d.RCC Man hole cover with frame as per ISI
316ii Diff.rates of materials :
317 From Mirthal
318 From Lohand Khad
319 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
320 From Mirthal 180 km
321 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 1029173.0 0.0535 55061.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 1084234.0 Total : CSR Amount : ( Rs) 1084234.0 Pumping Station, Panel Room Combined (Above GL) 1.Capital Works ' CSR based Items Brick masonary work (1:5) :
32211.6 Brick masonary work (1:5) : > 4.0 m. 11.29 b Extra for work above 4 meters ( where any single storey exceeds 4 meters in height 0 for every additional height of 2 meters or part thereof for Brick Work / concrete Block / Clay Block
323 CC 1:2:4 : 10.13 Cement concrete 1:2:4 (a) with stone ballast or shingle
324ii CC 1:4:8 : ( Below Ironite flooring) 10.11 Cement concrete 1:4:8 (a) with stone ballast 20 mm.gauge
325ii DPC :
32610.26 M-30 :
32710.22 Extra height Concrete : 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof. Above 4.0 m.height :
328 Steel :
32918.18 C / Shuttering : (Columns)
3309.4 C / Shuttering > 4.0 m.height : ( Columns) 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meterzs in height0 for every additional height of 1 metres or part thereof.
331 sqm 6.3
332 C/shuttering : 9.8 Centering and Shuttering for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc. : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meterzs in height0 for every additional height of 1 metres or part thereof. > 4.0 m.height :
333 C/shuttering : ( Lintels)
3349.6 CP 12.5 mm.thk. : (1:4)
33515.9 CP 12.5 mm.thk. : (1:2)
33615.7 Painting : White washing :
33716.3 Preparation of plastered surface :
33816.6 Distempering :
33916.7 Oil Bound Distemper :
34016.1 Earth filling under floors :
3416.8 / (a) / (ii) Ironite flooring:
34214.4 Steel windows and ventilators : 18.2 Supplying openable steel windows of stanard rolled steel Z-sections, joints mitred and electrically flash welded with iron fittings including necessary iron handles,Peg-stay catchers,bolts,iron plugs and pressed steel projected hinges and glazing clips,complete ( Excluding glazing) and finished with two coats of ready mixed paint red lead non setting primer.
343(b) Fixing :
34418.23 Glass panes : 18.25 Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.
345(a) Rolling Shutter :
34618.11 (a) Parapet Wall :
34711.36 CC 1:2:4 : ( coping ) 10.13 Cement concrete 1:2:4 (a) with stone ballast or shingle
348ii Cement Concrete 1:2:4 gola :
34913.55 Top Khurra :
35013.45 Bottom Khurra :
35113.51 Drip Course :
35211.42 Dry Brick edge paving :
35314.18 CI Rain water pipes :
35413.41 CI head :
35513.42 CI shoes :
35613.43 Embedding of CI Rain water pipes :
35713.44 Store Room Excavation : 6.7 Earthwork in excavation of foundations of bridges,culverts,building including handling of materials with combined lead of 15 metres dressing of bed and sides stacking the excavated soil clear from the edge of excavation and subsequent filling around
358(a) CC 1:2:4 : 10.13 Cement concrete 1:2:4 (a) With stone ballast or shingle
359ii M-30 :
36010.17 Brick masonary work in cm 1:5 :
36111.5 Diff.rates of materials :
362 From Mirthal 180 km
363 From Lohand Khad 220 km
364 From Firozpur
365 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
366 From Mirthal 180 km
367 From Lohand Khad 220 km Fine sand : 60 km Cum 15.350000000000001 371.49 Three Hundred Seventy One Rupees and Forty Nine Paise 5702.0 Capital Works ' CSR based Items ( In Rs) 1091348.0 0.0535 58387.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 1149735.0 Total : CSR Amount : ( Rs) 1149735.0 5(i) Water Treatment Plant 5.0 MLD Capacity (22 Hrs @227.08KLH) Sl. No. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' NON CSR based Items
36813.2.1PHED, Raj. BSR (2023-24) Capital Works ' NON CSR based Items ( In Rs) 23004130.0 Total : Non CSR Amount : ( Rs) 23004130.0 Mixing Chamber to CWR Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items Excavation : (Mech.) 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 16 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
369i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a)
3706.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
3714.1 (A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
372 2 nd and 3 rd chain,per chain of 30 meters
373 For subsequent chain per chain of 30 meters up to 0.50 km
374 C.C. 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
375ii M-30 :
37610.17 M-30 : Plinth level > 4.0 m 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof.
377 Shuttering :
3789.1 C / Shuttering : ( walls)
3799.2 C / Shuttering > 4.0 m.height : ( walls) 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height0 for every additional height of 1 metres or part thereof.
380 C / Shuttering : ( slab)
3819.8 Steel :
38218.18 PVC Foot Steps :
38329.35 RCC Manhole cover with frame : 29.34 Providing & fixing 560 mm.,500 mm and 450 mm.i/d.circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS : 12592 -2002,including carriage from the atores of the Engineer -in -charge to site of work,loading,unloading,including stacking and setting the same to correct lines over manholes,including cement concrete copping ( M-20) around the frameetc.Dia. of steel for lifting hook is 16 mm.( for EHD and HD) A RCC Man hole cover with frame a 560 mm.i/d.RCC Man hole cover with frame as per ISI
384ii Food Grade Epoxy Paint Work : Prepartion of Concrete surface :
38516.65 Cement Primer :
38616.31 Difference in rates of materials :
387 From Mirthal 180 km
388 From Lohand Khad 220 km
389 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
390 From Mirthal 180 km
391 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 345576.0 0.0535 18488.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 364064.0 1.Capital Works ' NON CSR based Items Providing and Applying Food grade Epoxy based water proof coat :
392NS Capital Works ' NON CSR based Items ( In Rs) 30066.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 364064.0 Non - CSR based amount ( In Rs) 30066.0 Total : CSR + Non CSR Amount : ( Rs) 394130.0 Inlet Valve Chamber to CWR Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items Earthwork in excavation : (Mechanically) 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 16 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
393i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a)
3946.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
3954.1 (A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
396 2 nd and 3 rd chain,per chain of 30 meters
397 For subsequent chain per chain of 30 meters up to 0.50 km
398 C.C. 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
399ii M-30 :
40010.17 Shuttering :
4019.1 C / Shuttering : ( walls)
4029.2 Steel :
40318.18 PVC Foot Steps :
40429.35 Pre Cast Slab Cover :
405CSr based item Sluice Valve : 28.27 Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronge (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing,testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d)
406(g ) DI K-7 Pipes : 28.7 B Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage,cost of rubber ring. A DI pipe as per IS 8329 DI-K7 Pipe lines laid complete. mm.i/d.
407(g) DI Specials : 28.25 Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.
408b Qty.: 5% of DI Pipe Cost/ 115.81 GI Pipe : ( Rising Pipe for Valve Operation) 28.35 Providing,laying,jointing,fixing and testing ISI Marked G.I.Pipe ( as per IS 1239 ) B -Class,including cost of specials ( such as tees,bends,sockets,elbows,etc.) painting with anti corrosive bitumastic paint,testing,cutting,threading Inside building complete. mm.i/d.
409b Diff. rates of materials :
410 From Mirthal 180 km
411 From Lohand Khad 220 km
412 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
413 From Mirthal 180 km
414 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 410093.0 0.0535 21940.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 432033.0 Total : CSR Amount : ( Rs) 432033.0 Chlorine Contact tank Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items Earthwork excavation : 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
415i Extra depth excavation : 29.2 / B Where depths of excavation exceeds 2.0 metre below ground levels or total quantity of excavation is more than 100 cum,total excavation will be paid as per chapter 6.19 and quantity of backfilling quantity as per item 4.1 (a)
4166.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
4174.1 (A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
418 2 nd and 3 rd chain,per chain of 30 meters
419 For subsequent chain per chain of 30 meters up to 0.50 km
420 C.C. 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
421ii M-30 :
42210.17 M-30 : > 4.0 m 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof.
423 Shuttering :
4249.1 C / Shuttering : ( Walls)
4259.2 C / Shuttering > 4.0 m.height : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height) for every additional height of 1 metres or part thereof.
426 C / Shuttering : ( Columns)
4279.4 C / Shuttering > 4.0 m.height : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height) for every additional height of 1 metres or part thereof.
428 C / Shuttering > 4.0 m.height : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height) for every additional height of 1 metres or part thereof.
429 C / Shuttering > 4.0 m.height : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height) for every additional height of 1 metres or part thereof.
430 Steel :
43118.18 Pre Cast Slab Cover over Chamber :
432 Food Grade Epoxy Paint Work : Prepartion of Concrete surface :
43316.65 Cement Primer :
43416.31 Diff.rates of materials :
435 From Mirthal 180 km
436 From Lohand Khad 220 km
437 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
438 From Mirthal 180 km
439 From Lohand Khad 220 km Capital Works ' CSR based Items ( In Rs) 1304333.0 0.0535 69782.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 1374115.0 1.Capital Works ' NON CSR based Items Providing and Applying Food grade Epoxy based water proof coat :
440NSTelengana CSR 2023 - 24 Buildings ( Part -III ) Sl.no.886 Capital Works ' NON CSR based Items ( In Rs) 88927.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 1374115.0 Non - CSR based amount ( In Rs) 88927.0 Total : CSR + Non CSR Amount : ( Rs) 1463042.0 Clear Water Reservoir Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items Earthwork excavation : 29.2 Earthwork in excavation for storage and sedimentation tanks,high level tanks,filter beds,clear water reservoirs,pump houses,sumps,screening chambers and other similar works having straight or open cuttings in foundation trenches etc. with 3D Excavator,JCB including manuially dressing of bed,trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches,stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering,dressing and disposal of surplus soils as directed upto 15 metre complete in all respects. A Depth upto 1.50 m.B.G.L.
441i Extra depth excavation :
4426.19 Loading by Mechanical means : Rate for loading into wagon,Trucks or boats within 15 meters lead.
4434.1 (A) Carriage of Earth : ( Balance earth Qty) 5.1 ( i) Surkhi,Sand,Earth,Fly Ash,Bajri,Ballast,Stone Boulders,kankar and Building Rubbish.
444 2 nd and 3 rd chain,per chain of 30 meters
445 For subsequent chain per chain of 30 meters up to 0.50 km
446 C.C. 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
447ii M-30 :
44810.17 M-30 : > 4.0 m 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof. cum
449 Brick Masonary Work : 11.6 First class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 meters above plinth level. cum 4.5448 5151.0 Five Thousand One Hundred Fifty One Rupees and No Paise 23410.0 Steel Chowkats : 18.24 Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete.
450(c) SS Handles :
45117.7 SS Tower Bolts :
45217.77 CP 12.5 mm :
45315.7 Painting : White washing :
45416.3 Distempering :
45516.7 Shuttering :
4569.1 C / Shuttering : ( Walls)
4579.2 C / Shuttering > 4.0 m.height : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height) for every additional height of 1 metres or part thereof.
458 C / Shuttering : ( Columns)
4599.4 C / Shuttering > 4.0 m.height : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height) for every additional height of 1 metres or part thereof.
460 C / Shuttering : ( Beam ) 9.6 Centering and shuttering for sides and soffits of beam,beams,launching girders,bressumers,lintels. C / Shuttering > 4.0 m.height : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height) for every additional height of 1 metres or part thereof.
461 C / Shuttering > 4.0 m.height : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meters in height) for every additional height of 1 metres or part thereof. 5.0 - 6.0 m sqm 357.01964438495304 573.0 Five Hundred Seventy Three Rupees and No Paise 204572.0 Staircase Railing :
46218.3 Steel :
46318.18 Prepartion of Concrete surface :
46416.65 Cement Primer :
46516.31 Diff.Rates :
466 From Mirthal 180 km
467 From Lohand Khad 220 km
468 From Ferozpur
469 Carriage : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
470 From Mirthal 180 km
471 From Lohand Khad 220 km
472 Capital Works ' CSR based Items ( In Rs) 6077794.0 0.0535 325162.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 6402956.0 1.Capital Works ' NON CSR based Items Steel Doors : NSRUIDP SOR 2023 / Code no. 29.12 Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators side / top / centre hung with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted with 15 x 3 mm lugs, 10 cm long, embedded in cement concrete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design. sqm 4.797 3830.0 Three Thousand Eight Hundred Thirty Rupees and No Paise 18373.0 Steel beading :
473NS RUIDP SOR 2023 / Code no. 29.13 CI Ventilator Cowl :
474Chhattisgarh CSR June 2020Item no.26.3 Providing and Applying Food grade Epoxy based water proof coat :
475NS Capital Works ' NON CSR based Items ( In Rs) 427060.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 6402956.0 Non - CSR based amount ( In Rs) 427060.0 Total : CSR + Non CSR Amount : ( Rs) 6830016.0 RW Sump and Pumping Machinery Room, Panel Room & Store room Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount (Rs) 1.Capital Works ' CSR based Items Pumping station and Panel Combined Brick masonary work (1:5) : ( up to 4.0 m.height)
47611.6 Brick masonary work (1:5) : ( above 4.0 m.height) ( 4.0 - 6.0 m ) 11.29 b Extra for work above 4 meters ( where any single storey exceeds 4 meters in height 0 for every additional height of 2 meters or part thereof for Brick Work / concrete Block / Clay Block
477 CC 1:2:4 : 10.13 Cement concrete 1:2:4 (a) with stone ballast or shingle
478ii DPC :
47910.26 M-30 :
48010.22 Extra height Concrete : 10.49 Extra for RCC / PCC work done above 4 meters height ( where any single storey exceeds 4 meters in height ) for every additional height of 1 metres or part thereof. > 4.0 m :
481 Steel :
48218.18 C / Shuttering : (Columns)
4839.4 C / Shuttering > 4.0 m.height : ( Columns) 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meterzs in height0 for every additional height of 1 metres or part thereof.
484 C/shuttering : 9.8 Centering and Shuttering for flat surfaces such as suspended floors,roofs,landings,chajjas,shelves etc. : 9.16 Extra rate for shuttering work done above 4 meters height ( where any single storey exceeds 4 meterzs in height0 for every additional height of 1 metres or part thereof.
485 C/shuttering : ( Lintels)
4869.6 CP 12.5 mm.thk. : (1:4)
48715.9 CP 12.5 mm.thk. : (1:2)
48815.7 Painting : White washing :
48916.3 Preparation of plastered surface :
49016.6 Distempering :
49116.7 Oil Bound Distemper :
49216.1 Earth filling under floors :
4936.8 / (a) / (ii) Ironite flooring:
49414.4 Steel windows and ventilators : 18.2 Supplying openable steel windows of stanard rolled steel Z-sections, joints mitred and electrically flash welded with iron fittings including necessary iron handles,Peg-stay catchers,bolts,iron plugs and pressed steel projected hinges and glazing clips,complete ( Excluding glazing) and finished with two coats of ready mixed paint red lead non setting primer.
495(b) Fixing :
49618.23 Glass panes : 18.25 Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.
497(a) Doors Shutter : 17.17 (i) Kail wood doors shutter and window shutter panelled,galzed or glazed and panelled,including hinges,screws,chokes,cleats and cords etc. complete fixed in position.(Single Leaf)
498(a) Aluminium Fittings : 17.23 Cost of Aluminium fittings complete for doors,windows such as tower bolts,handles,Stoppers and screw etc.for these fittings.(Excluding sliding bolt)
499(ii) Steel Chowkats : 18.24 Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete.
500(c) Rolling Shutter :
50118.11 (a) Parapet Wall :
50211.36 CC 1:2:4 : ( coping ) 10.13 Cement concrete 1:2:4 (a) with stone ballast or shingle
503ii Cement Concrete 1:2:4 gola :
50413.55 Top Khurra :
50513.45 Bottom Khurra :
50613.51 Drip Course :
50711.42 Dry Brick edge paving :
50814.18 CI Rain water pipes :
50913.41 CI head :
51013.42 CI shoes :
51113.43 Embedding of CI Rain water pipes :
51213.44 Store Room Excavation : 6.7 Earthwork in excavation of foundations of bridges,culverts,building including handling of materials with combined lead of 15 metres dressing of bed and sides stacking the excavated soil clear from the edge of excavation and subsequent filling around
513(a) CC 1:2:4 : 10.13 Cement concrete 1:2:4 (a) With stone ballast or shingle
514ii M-30 : Plinth level
51510.17 Brick masonary work in cm 1:5 : (plinth level)
51611.5 Difference Rates :
517 From Mirthal 180 km
518 From Lohand Khad 220 km
519 From Ferozpur
520 Carriage of Materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
521 From Mirthal 180 km
522 From Lohand Khad 220 km
523 Capital Works ' CSR based Items ( In Rs) 1282507.0 0.0535 68614.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 1351121.0 Total : CSR Amount : ( Rs) 1351121.0 Clear Water Transmission Main DI K-7 Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items Excavation : ( Manually) 28.1 Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. (a) Earthwork upto 1.50 mt.Depth.
524i Excavation : (Mech.) 28.2 Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. (a) Earthwork upto 1.50 mt.Depth.
525i DI K-7 Pipes : 28.7 B Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage,cost of rubber ring. A DI pipe as per IS 8329 DI-K7 Pipe lines laid complete.
526(f ) DI Specials : 28.25 Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.
527a D / F Pipe : 28.23 Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Double Flanged Pipes with screwed,flanged as per IS : 8329 - 2000,Class K -9 and laying the same in trenches to correct alingnment and gradients,jointed with nut bolts and rubber insertion joints fitted complete including all cartage. Pipe lines laid complete.
528g Sluice Valve : 28.27 Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronge (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing,testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d) (e ) 250.0 Each 2.0 22337.15 Twenty Two Thousand Three Hundred Thirty Seven Rupees and Fifteen Paise 44674.0 (f ) 300.0 Each 2.0 27999.03 Twenty Seven Thousand Nine Hundred Ninety Nine Rupees and Three Paise 55998.0 Sluice Valve : ( To be used as Scour Valve) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d)
529(b ) Valve chambers : 28.66 Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
530b Diff.rates of materials :
531 From Mirthal 180 km
532 From Lohand Khad 220 km
533 From Ferozpur
534 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
535 From Mirthal 180 km
536 From Lohand Khad 220 km
537 Bailing out of water : 28.49 Bailing out water from the trenches for making new connections in existing pipe lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge.
538a Capital Works ' CSR based Items ( In Rs) 35897507.0 0.0535 1920517.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 37818024.0 Total : CSR Amount : ( Rs) 37818024.0 1.Capital Works ' NON CSR based Items Air Valve : NS Based on PHED Rajasthan 2023Code no.6.6 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide-HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material,labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work.
5396.6.1 6.6.1.1 40 mm Capital Works ' NON CSR based Items ( In Rs) 157836.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 37818024.0 Non - CSR based amount ( In Rs) 157836.0 Total : CSR + Non CSR Amount : ( Rs) 37975860.0 Minor Canal Crossing Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items 18.1 Steel work,fixed independentally without connecting plates, including cutting,hoisting and fixing in position.
54018.15
54116.17 Capital Works ' CSR based Items ( In Rs) 6924.0 0.0535 370.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 7294.0 Total : CSR Amount : ( Rs) 7294.0 Thrusting/trenchless Crossing Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' NON CSR based Items
542N.S Capital Works ' NON CSR based Items ( In Rs) 2705850.0 Total : Non CSR Amount : ( Rs) 2705850.0 Distribution Pipeline within WTP Premises Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items Excavation : ( Manually) 28.1 Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. (a) Earthwork upto 1.50 mt.Depth.
543i Excavation : (Mech.) 28.2 Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. (a) Earthwork upto 1.50 mt.Depth.
544i DI K-7 Pipe : 28.7 B Providing, Stringing out, cutting, Jointing and testing of ISI Marked D.I. Pipe (S&S) as per IS 8329 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted complete including all cartage,cost of rubber ring. A DI pipe as per IS 8329 DI-K7 Pipe lines laid complete.
545(b) uPVC Pipe : 28.12 Providing and laying,jointing,fixing and testing ISI Marked uPVC Pipe lines as per ISI -4985 -2000, including specials such as tees,bends,sockets,elbow etc.cutting,testing ( including cost of specials ),in the ground complete in all respects. B uPVC Pipe 6 kgf /cm2
546a DI Specials : 28.25 Supplying & laying D.I. specials / fittings as per IS :9523-2000 (ISI marked with prior approval of Engineer-in-Charge ) class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining,scaffolding,tools and plants,ropes,guys,etc.Complete in all respects.
547a Sluice Valve : 28.27 Providing & fixing C.I./D.I.Flanged end,stem of SS (AIS 1410) and Bronge (gunmetal) working parts Sluice Valves ISI marked 14846-2000 including jointing,testing & cost of Nut,Bolt & Insertion sheet all carriage complete.(with the approval of Enginner-in-charge.) B Class PN-1.6 as per ISI Sluice Valves flanged.(mm.i/d)
548(b ) Jointing of DI pipes : ( for specials) 28.1 Jointing of D.I.Pipe and Specials with rubber tyton joints fitted complete excluding the cost of rubber gasket including testing etc.complete in all respect.(Note : This Item will be paid as per site requirement.) mm.i/d.pipe lines.
549(b) CI Surface Boxes :
55028.32 C.I.Indicating Plates :
55128.33 Valve chambers : 28.66 Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department.
552a SV : 100 & 150 mm.dia. FH : Size : 80 mm. Diff.rates of materials :
553 From Mirthal 180 km
554 From Lohand Khad 220 km
555 From Ferozpur
556 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
557 From Mirthal 180 km
558 From Lohand Khad 220 km
559 Bailing out of water : 28.49 Bailing out water from the trenches for making new connections in existing pipe lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge.
560a Capital Works ' CSR based Items ( In Rs) 207148.0 0.0535 11082.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 218230.0 Total : CSR Amount : ( Rs) 218230.0 Boundary Wall Sl.no. Reference Particulars of Items and details of works Unit Quantity Rate (Rs) Rate in words (Rs) Amount 1.Capital Works ' CSR based Items Excavation :
5616.19 CC 1:2:4 : 10.13 Cement concrete 1:2:4 a With stone ballast or shingle
562ii M-30 :
56310.17 Steel :
56418.18 Shuttering :
5659.1 C / shuttering : ( Columns)
5669.4 C / shuttering : ( Beams)
5679.6 115 mm.thk.BBM :
56811.36 CP 20 mm.thk. :
56915.2 White wash :
57016.3 Dry distemper :
57116.7 Sliding Shutters :
57218.9 Diff.in rates of materials :
573 From Mirthal 180 km
574 From Lohand Khad 220 km
575 From Ferozpur
576 Carriage of materials : 5.2 (i) Earth,Surkhi,Sand,earth,Fly Ash,Bajri,Ballast,Stone Boulders,Kankar and Building Rubbish,Earth
577 From Mirthal 180 km
578 From Lohand Khad 220 km
579 Capital Works ' CSR based Items ( In Rs) 3965119.0 0.0535 212134.0 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 4177253.0 1.Capital Works ' NON CSR based Items Barbed wire fencing : 1.2 Meter High G.I.Barbed Wire fencing
580NS (Rate analysis based on CSR item no.24.43 ) Capital Works ' NON CSR based Items ( In Rs) 179400.0 Capital Works CSR based amount after adding 5.35% ( In Rs) 4177253.0 Non - CSR based amount ( In Rs) 179400.0 Total : CSR + Non CSR Amount : ( Rs) 4356653.0 Summary of Mechanical Work for WTP at Mallanwala Khas ,District Ferozepur S. No. Description Amount (in Rs.)
581Intake Pumping Station
582Raw Water Pumping Station including Floating Arms
583S&S Tank - Dewatering Pumps
584Clear Water Pumping Station Total 13550156.9961025 Intake Pumping Station ( For 24 Hours) Sr.no CSR Item No Specification Unit Qty Total Rate(Rs) Total Rate in Word Amount (Rs) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: Mechanical Works: D.I.Specials : 28.25 Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects.
585a Non Return Valve 28.31 Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra B Class pn - 1.6 as per ISI with gun metal flap
586e Sluice Valve : 28.27 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge)
587B(d) G.I.Pipe : 40 mm.i/d. 28.36, Providing and laying,jointing,fixing,testing ISI Marked G.I.Pipe ( as per IS : 1239) B-Class premium make such as (approved make) including cost of specials such as tees,bends,sockets,elbow etc.cutting,threading and testing in trenches in the ground complete.
588e Capital Works ' CSR based Items ( In Rs) 150563.654 0.0535 8055.155489000001 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 158618.809489 Vertical Turbine (VT) Pump NS Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Vertical Turbine (VT) Pump with squiral cage induction motor of CI IS: 210 GR FG 260 with 2% Nickel Casing & suction bowl, Impeller CF 8M ,Shaft SS 410 ,Sole/ Base plate & Column pipe MS to IS 2062 Gr. B,Motor stool and Foundation bolts etc. complete with all respect as per specification.
589 DI flanged Pipe (RUIDP 2023,19.13) Providing, lowering, laying in trenches, aligning, fixing in position and double flanged (welded) centrifugally (spun) Ductile iron ISI marked K-9 grade pipes as per IS:8329-2000 (amended upto date), (including jointing and jointing material) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.
590 Dismantling joint (RUIDP 2023,19.56) Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
591 EOT (RUIDP SOR 2023,18.9) Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer.
592 SS Manual Coarse Bar Screen ( 0.9 X 4.5 ) M NS Supply,fabrication,fixing and Testing of stainless steel (SS-304) Manual Coarse Bar Screen with flat bar 50 mm x 8 mm, spacing of bars 20 mm suitable for mounting in channel of specified size with inclination not more than 75 degree and a movable complete in all respect as per Technical specification,reputed make and the direction of the Engineer
593 Motorized Sluice Valve : (RUIDP 2023,19.29) Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. Electrically Operated & SCADA Compatible class PN 1.6
594 Motorized Butterfly Valve : ( RUIDP 2023,19.34) Providing, lowering, laying, aligning, fixing in position in pipe line,Resilient Seated D/F DI Butterfly valves of approved make & design standard of following dia. complete (including jointing & jointing material) including all material, labour, testing and commissioningalong with pipeline as per Technical Specification & as per direction of Engineer. Electrically Operated & SCADA Compatible class PN 1.6
595 Rubber expansion bellows NS Providing, installation, testing and commissioning of following Rubber Expansion bellows of 16 bar rating, MS split flange,Class 150#, with tie rods & 6 plates, single convolution bellows. as per technical specifications and layout drawings including jointing material like nuts, bolts, plates etc. complete in all respect as per technical specification and as per direction of Engineer.
596 Puddle collar (RUIDP SOR 2023,19.63) Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specifications and as per direction of Engineer.
597 Capital Works ' NON CSR based Items ( In Rs) 3150345.7060000002 Capital Works CSR based amount after adding 5.35% ( In Rs) 158618.809489 Non - CSR based amount ( In Rs) 3150346.0 Total : CSR + Non CSR Amount : ( Rs) 3308965.0 Total in Lakh 33.08965 Raw Water Pumping Station (Pump for 22 Hours) Sr.no CSR Item No Specification Unit Qty Total Rate(Rs) Total Rate in Word Amount (Rs) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: Mechanical Works: D.I.Specials : 28.25 Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects.
598a Non Return Valve 28.31 Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra B Class pn - 1.6 as per ISI with gun metal flap
599e Sluice Valve : 28.27 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge)
600B(e) G.I.Pipe : 40 mm.i/d. 28.36, Providing and laying,jointing,fixing,testing ISI Marked G.I.Pipe ( as per IS : 1239) B-Class premium make such as (approved make) including cost of specials such as tees,bends,sockets,elbow etc.cutting,threading and testing in trenches in the ground complete.
601e Capital Works ' CSR based Items ( In Rs) 234561.44400000002 0.0535 12549.037254 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 247110.481254 Vertical Turbine (VT) Pump NS Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Vertical Turbine (VT) Pump with squiral cage induction motor of CI IS: 210 GR FG 260 with 2% Nickel Casing & suction bowl, Impeller CF 8M ,Shaft SS 410 ,Sole/ Base plate & Column pipe MS to IS 2062 Gr. B,Motor stool and Foundation bolts etc. complete with all respect as per specification.
602 DI flanged Pipe (RUIDP 2023,19.13) Providing, lowering, laying in trenches, aligning, fixing in position and double flanged (welded) centrifugally (spun) Ductile iron ISI marked K-9 grade pipes as per IS:8329-2000 (amended upto date), (including jointing and jointing material) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.
603 Dismantling joint (RUIDP 2023,19.56) Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
604 EOT (RUIDP 2023,18.9.) Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches , LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer and two coat of synthetic paint and as per the direction of the Engineer.
605 Puddle collar (RUIDP 2023,19.63) Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specifications and as per direction of Engineer.
606 Motorized Sluice Valve : ( RUIDP 2023,19.29) Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. Electrically Operated & SCADA Compatible class PN 1.6
607 Motorized Butterfly Valve : ( RUIDP 2023,19.34) Providing, lowering, laying, aligning, fixing in position in pipe line,Resilient Seated D/F DI Butterfly valves of approved make & design standard of following dia. complete (including jointing & jointing material) including all material, labour, testing and commissioningalong with pipeline as per Technical Specification & as per direction of Engineer. Electrically Operated & SCADA Compatible class PN 1.6
608 Floating Arm NS Providing, installation, testing and commissioning of SS 304 floating suction assly.(Floating arms). of flange ,elbow,pipe ,swivel joint, float assly and bell mouth assly as per technical specifications and layout drawings including jointing material like nuts, stud, gasket etc. complete in all respect as per technical specification and as per direction of Engineer.
609 Rubber expansion bellows NS Providing, installation, testing and commissioning of following Rubber Expansion bellows of 16 bar rating, MS split flange,Class 150#, with tie rods & 6 plates, single convolution bellows. as per technical specifications and layout drawings including jointing material like nuts, bolts, plates etc. complete in all respect as per technical specification and as per direction of Engineer.
610 Capital Works ' NON CSR based Items ( In Rs) 5527273.32 CSR based amount after adding 5.35% ( In Rs) 247110.481254 Non - CSR based amount ( In Rs) 5527274.0 Total : CSR + Non CSR Amount : ( Rs) 5774384.0 Total in Lakh 57.74384 Dewatering Pump Sr.no CSR Item No Specification Unit Qty Total Rate(Rs) Total Rate in Word Amount (Rs) Supply, Installation, testing, and commissioning of the following items complete in all respects and as per scope of work, specification, and as required at site: Mechanical Works: DI flanged Pipe 28.23, Providing, Stringing out, cutting, Jointing, and testing of ISI Marked D.I. Double Flanged pipes with screwed flanged as per IS:83292000, Class-K9 and laying the same in trenches to correct alignment and gradients, jointed with nut bolts and rubber insertion joints fitted complete including all cartage.
611c D.I.Specials : 28.25 Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects.
612a Non Return Valve 28.31 Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt, rubber insertion, etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 then 5% will be paid extra B Class pn - 1.6 as per ISI with gun metal flap
613d Sluice Valve : 28.27 Providing & fixing C.I/D. I Flanged end, stem of SS (AIS 1410), and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer)
614B(c) Lifting arrangement for pumps 18.1, Steel work fixed independently without connecting plates including cutting hoisting and fixing in position
615a Capital Works ' CSR based Items ( In Rs) 256825.815 0.0535 13740.1811025 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 270565.9961025 Non -Clog Submersible pump (RUIDP 2023,18.1.8) Supply delivery at the site with necessary packing, receiving, unloading, shifting, storing, installation, testing, and commissioning of Non-clog submersible pumping set of 2% Ni CI Cascading, Impeller CF 8M, Shaft SS 410, mechanical seal with 10M Power & Control cable, 5M SS Chain,,10M, 50mm SS Guide pipe, Duck Foot Bend, with Guide wire SS 304, etc. complete with all respect as per specification
616 Dismantling joint (RUIDP 2023,19.56) Providing, lowering, laying, aligning, fixing in position, and jointing CI dismantling joint (suitable for sluice valves, etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing, and commissioning as per Technical Specifications and as per direction of Engineer.
617 Lifting arrangement for pumps
618NS (RUIDP 2023,18.10) Supply, installation, and commissioning of Mono Rail Single Girder Crane suitable for lift up to 9m with chain 9m pulley block and traveling trolley excluding cost of girder complete in all respects as per the direction of the Engineer.
619 Capital Works ' NON CSR based Items ( In Rs) 434410.0 CSR based amount after adding 5.35% ( In Rs) 270565.9961025 Non - CSR based amount ( In Rs) 434410.0 Total : CSR + Non CSR Amount : ( Rs) 704975.9961025 Total in Lakh 7.049759961025 Clear Water Pumping Station (Pump for 22 Hours) Sr.no CSR Item No Specification Unit Qty Total Rate(Rs) Total Rate in Word Amount (Rs) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: Mechanical Works: D.I.Specials : 28.25 Supplying and laying D.I. specials/fittings as per IS:9523-2000 (ISI marked with the prior approval of Engineer-in-Charge), class K-12 suitable for tyton joint with external bitumen coating and inside cement mortar lining, scaffolding, tools and plants, ropes, guys, etc. Complete in all respects.
620b Non Return Valve 28.31 Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra B Class pn - 1.6 as per ISI with gun metal flap
621e Sluice Valve : 28.27 Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge)
622B(d) G.I.Pipe : 40 mm.i/d. 28.36 Providing and laying,jointing,fixing,testing ISI Marked G.I.Pipe ( as per IS : 1239) B-Class premium make such as (approved make) including cost of specials such as tees,bends,sockets,elbow etc.cutting,threading and testing in trenches in the ground complete.
623e Capital Works ' CSR based Items ( In Rs) 219755.51400000002 0.0535 11756.919999000002 Capital Works ' CSR based Items after adding 5.35% ( In Rs) 231512.43399900003 Vertical Turbine (VT) Pump NS Supply delivery at site with necessary packing, receiving, unloading, shifting, storing, installation, testing and commissioning of Vertical Turbine (VT) Pump with squiralcage induction motor of CI IS: 210 GR FG 260 with 2% Nickel Casing & suction bowl, Impeller CF 8M ,Shaft SS 410 ,Sole/ Base plate & Column pipe MS to IS 2062 Gr. B, Motor stool and Foundation bolts etc. complete with all respect as per specification.
624 DI flanged Pipe (RUIDP 2023,19.13) Providing, lowering, laying in trenches, aligning, fixing in position and double flanged (welded) centrifugally (spun) Ductile iron ISI marked K-9 grade pipes as per IS:8329-2000 (amended upto date), (including jointing and jointing material) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.
625 Dismantling joint (RUIDP 2023,19.56) Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.
626 EOT (RUIDP 2023,18.9) Supplying, erecting, testing & commissioning of Electrically Operated Travelling Crane (EOT) .Main girder & End Carriage fabricated from Rolled Steel Section, Gear Box for all motion, Electro Magnetic Friction Disc Type Brakes, all safety limit switches, LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor of adequate rating (KW), duly painted mechanical cleaning and one coat of primer, and two coats of synthetic paint and as per the direction of the Engineer.
627 Motorized Sluice Valve : ( RUIDP 2023,19.29) Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer. Electrically Operated & SCADA Compatible class PN 16
628 Motorized Butterfly Valve : (RUIDP 2023,19.34) Providing, lowering, laying, aligning, fixing in position in pipe line,Resilient Seated D/F DI Butterfly valves of approved make & design standard of following dia. complete (including jointing & jointing material) including all material, labour, testing and commissioningalong with pipeline as per Technical Specification & as per direction of Engineer. Electrically Operated & SCADA Compatible class PN 1.6
629 Rubber expansion bellows NS Providing, installation, testing and commissioning of following Rubber Expansion bellows of 16 bar rating, MS split flange,Class 150#, with tie rods & 6 plates, single convolution bellows. as per technical specifications and layout drawings including jointing material like nuts, bolts, plates etc. complete in all respect as per technical specification and as per direction of Engineer.
630 Puddle collar (RUIDP 2023,19.63) Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specifications and as per direction of Engineer.
631 Capital Works ' NON CSR based Items ( In Rs) 3530319.48 CSR based amount after adding 5.35% ( In Rs) 231512.43399900003 Non - CSR based amount ( In Rs) 3530320.0 Total : CSR + Non CSR Amount : ( Rs) 3761832.0 Total in Lakh 37.61832 Summary of Electrical, Instrumentation & SCADA Work, Mallanwala Khaas S. No. Description Amount (Rs.)
632Intake Pumping Station
633Raw Water Pumping Station
634Clear Water Pumping Station
635Sub-Station for Raw & Clear water Pumping Station and WTP
636SCADA for Intake, Raw Water & Clear Water Pumping Station, WTP & Sub-Station Total (in Rs.) 16410609.0 Total (in Lakhs) 164.10609 Electrical, Instrumentation & RTU Works for Intake Pump House, Water Suppy- Malanwala Khaas Sr.No. Item No. Description Unit Qty Rate (Rs) Rate (Rs. In Words) Amount (Rs.) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: 1. Capital Works ' CSR based Items A. HT Cables & Accessories: 34.36 XLPE INSULATED HT CABLES: 34.36 A XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND): Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:-
637(v) 34.36 C S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:-
638(iii)
639(vii) B. LT Cables & Accessories: 34.10 A XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1) 1988 to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & first class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-
640(xxv) 34.10 B XLPE INSULATED ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
641(xxv)
642(xxxv) 34.25 CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
643(ii) 34.37 DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: 34.37 B Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2 mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
644(iii)
645(iv) 34.38 C Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.
646(iii)
647(viii) 34.38 A Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
648(v) C. Earthing: 34.13 (xiv) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. To make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling).
649(b) 34.13 (xv) Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-
650(c) D. Wiring, Lighting & Accessories (for Panel room, Pump House): 34.04 RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES : Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked reccessed in wall etc., complete with powder coated/anodised concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts ( socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20 Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3 mm.thick etc. PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1.5\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
651(i) b
652(vi) 34.09 (xiii) Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
653(c.) 34.17 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's: Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with rovision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General Specifications including connections with suitable size of thimbles and bonding to existing earth etc.
654(ii) 34.16 A MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10KA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
655(vi) 34.29 B Single Arm Brackets for GI Pipe Pole: (i) Supply and erection of GI pipe 40mm dia (A-class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105 deg., the bracket should be fixed on top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect approved by Engineer- in -charge at site:-
656(a) E. Outdoor Lighting: 34.31 3-STEPPED STEEL TUBULAR POLE: Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SPMpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to fill up to 15 cm below G/L with 1:2:4 cement concrete mixture including painting of pole with two coats of approved aluminium paint as required:-
657(i) 34.33 CEMENT CONCRETE MUFFS: (v) Making of cement concrete muff of overall size 450mmdia., suitable length (15cm below ground level) with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole/ GI pipe pole. The outer surface of the muff shall be finished with 1:2 cement plaster with two coats of white snowcem complete in all respect as approved and desired by the Engineer in- Charge at site:-
658(a) 34.29 C SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE: (i) Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos.½\\" x 1½\\" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thick triangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:-
659(a) 34.12 PVC, HDPE PIPES & PVC FLEXIBLE PIPES: (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposesincluding bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
660(x) 34.33 (vii) Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-
661(a) 34.09 (xii) Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexiblewire with copper conductor cable (ISI marked) confirm to IS:694/1990 left barein pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-
662(d) Capital Works 'CSR based Electrical, Instrumentation & PLC Items ( In Rs) 428174.9 0.0535 22907.35715 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works 'CSR based Electrical, Instrumentation & PLC Items after adding 5.35% ( In Rs) 451082.25715 2.Capital Works ' Non-CSR based Items A. HT System:
663RUIDP ISOR 2023, 72.4
664RUIDP ISOR 2023, 72.4 RUIDP ISOR 2023, 72.2 SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
665B. B. LT Panel with Starter:
666NS C. LT Cables & Accessories: RUIDP ISOR 2023, 60.4 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2.5 Sq. mm (Ref: 60.4.2)
667D. D. Earthing: RUIDP ISOR 2023, 63.5 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
66834.13 (xx) E. Wiring, Lighting & Accessories (for Panel room, Pump House): RUIDP ISOR 2023, 66.4 Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in- charge. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Surface Mounting (Ref: 66.4.2)
669RUIDP ISOR 2023, 64.12 RUIDP ISOR 2023, 64.12 Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
670RUIDP ISOR 2023, 64.11 RUIDP ISOR 2023, 64.11 Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
671RUIDP ISOR 2023, 67.12 RUIDP ISOR 2023, 67.12 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
672F. F. Outdoor Lighting: RUIDP ISOR 2023, 67.12 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
673G. G. Flow Meter, RTU, Pressure Gauge & Cables: RUIDP ISOR 2023, 43.28 Supply, Installation, testing and commissioning of Battery powered Electromagnetic flow meters with GSM/GPRS based with an accuracy of ± 1% of measured value, ingress protection Electronics IP 66 and flow tube IP 68, MOC: lining Neoprene rubber/Hard rubber/PTFE, Flange - SS316/SS304/MS/CS, Electrode - SS 316/Hastalloy, Coil Housing - SS, battery life of min. 5 years, LCD display 5 digit for instantaneous flow and 9 digit for Totalized flow as per technical specifications of following sizes:
674RUIDP ISOR 2023, 47.12
675RUIDP ISOR 2023, 73.41 RUIDP ISOR 2022, E111500 Providing and laying Stranded/ Flexible Annealede Bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. 1.5 sq.mm (Ref; E111540)
676RUIDP ISOR 2022, E111400 RUIDP ISOR 2022, E111400 Providing and laying Stranded/ Flexible Annealede Bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. 1.5 sq.mm (Ref; E111440)
677 Capital Works 'Non CSR based Electrical, Instrumentation & PLC Items ( In Rs) 1284559.0 Total : Part - C ( Electrical, Instrumentation & PLC ) CSR + Non CSR Amount : ( Rs) 1735641.0 Electrical, Instrumentation & PLC Works for Raw Water Pump House, Water Suppy- Malanwala Khaas Sr.No. Item No. Description Unit Qty Rate (Rs) Rate (Rs. In Words) Amount (Rs.) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: 1. Capital Works ' CSR based Items A. LT Cables & Accessories: 34.10 A XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1) 1988 to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & first class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-
678(xxvii) 34.10 B XLPE INSULATED ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
679(xxxv)
680(xxvii) 34.25 CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
681(ii) 34.37 DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: 34.37 B Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2 mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
682(iii)
683(iv) 34.38 C Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.
684(iii)
685(ix) 34.38 A Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
686(vii) B. Earthing: 34.13 (xiv) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. To make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling).
68734.13 (xx) C. Wiring, Lighting & Accessories (for Panel room, Pump House): 34.04 RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES : Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked reccessed in wall etc., complete with powder coated/anodised concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts ( socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20 Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3 mm.thick etc. PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1.5\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
688(i) b
689(vi) 34.09 (xiii) Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
690(c.) 34.17 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's: Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with rovision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General Specifications including connections with suitable size of thimbles and bonding to existing earth etc.
691(iii) 34.16 A MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10KA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
692(vi) 34.29 B Single Arm Brackets for GI Pipe Pole: (i) Supply and erection of GI pipe 40mm dia (A-class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105 deg., the bracket should be fixed on top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect approved by Engineer- in -charge at site:-
693(a) Capital Works 'CSR based Electrical, Instrumentation & PLC Items ( In Rs) 409926.45 0.0535 21931.065075 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works 'CSR based Electrical, Instrumentation & PLC Items after adding 5.35% ( In Rs) 431857.515075 2.Capital Works ' Non-CSR based Items A. LT Panel with Starter:
694NS B. LT Cables & Accessories: RUIDP ISOR 2023, 60.4 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2.5 Sq. mm (Ref: 60.4.2)
695C. C. Earthing: RUIDP ISOR 2023, 63.5 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
696D. D. Wiring, Lighting & Accessories (for Panel room, Pump House):
697NS RUIDP ISOR 2023, 66.4 Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in- charge. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Surface Mounting (Ref: 66.4.2)
698RUIDP ISOR 2023, 64.12 RUIDP ISOR 2023, 64.12 Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
699RUIDP ISOR 2023, 64.11 RUIDP ISOR 2023, 64.11 Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
700RUIDP ISOR 2023, 67.12 RUIDP ISOR 2023, 67.12 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.
701E. E. Level Transmitter, PLC, Pressure Gauge, Cables: RUIDP ISOR 2023, 43.27 Supply, Installation, testing and commissioning of Battery Operated Ultrasonic Level Transmitters with an accuracy of ± 0.25% of full sacle, ingress protection IP 65, MOC electronic enclosure Aluminium die cast/SS316, battery life of min. 5 years, LCD display 8 X 1 character as per technical specifications
702RUIDP ISOR 2023, 47.1 RUIDP ISOR 2023, 47.1 Design, Manufacture, Supply, Installation, Testing andCommissioning of Indoor type PLC Panel of size approx. 800 mm X500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI No. 30DO No. 26AI No. 6AO No. 2MCB 16A DP No. 2MCB 6A DP No. 6SMPS 100-240VAC/ 4.5A / 24 VDC No. 1Selector Switch (Auto/Manual) & Local / Remote No. 2Control Relays Lot 1Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with No. 1Electronic Hooter No. 1Control Transformer 200VA No. 1Emergency STOP Push Button No. 1Panel Cooling Fan & Filter No. 2Panel Light with Door Switch, 7W No. 1
703RUIDP ISOR 2023, 73.41 RUIDP ISOR 2022, E111500 Providing and laying Stranded/ Flexible Annealede Bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. 1.5 sq.mm (Ref; E111540)
704RUIDP ISOR 2022, E111400 RUIDP ISOR 2022, E111400 Providing and laying Stranded/ Flexible Annealede Bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. 1.5 sq.mm (Ref; E111440)
705 Capital Works 'Non CSR based Electrical, Instrumentation & PLC Items ( In Rs) 1496200.0 Total : Part - C ( Electrical, Instrumentation & PLC ) CSR + Non CSR Amount : ( Rs) 1928058.0 Electrical, Instrumentation & PLC Works for Clear Water Pump House, Water Suppy- Malanwala Khaas Sr.No. Item No. Description Unit Qty Rate (Rs) Rate (Rs. In Words) Amount (Rs.) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: 1. Capital Works ' CSR based Items B. LT Cables & Accessories: 34.10 A XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1) 1988 to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & first class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-
706(xxxi) 34.10 B XLPE INSULATED ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
707(xiii)
708(xxxi)
709(xxxv) 34.25 CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
710(ii) 34.37 DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: 34.37 B Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2 mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
711(iii)
712(iv) 34.38 C Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.
713(iii)
714(vii)
715(xiii) 34.38 A Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
716(xi) C. Earthing: 34.13 (xiv) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. To make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling).
71734.13 (xx) D. Wiring, Lighting & Accessories (for Panel room, Pump House): 34.04 RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES : Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge welded conduit pipe 20 mm./25 mm. dia.(1.6 mm. thick) ISI Marked reccessed in wall etc., complete with powder coated/anodised concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts ( socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20 Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3 mm.thick etc. PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1.5\\" deep for walls and 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100 volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
718(i) b
719(vi) 34.09 (xiii) Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
720(c.) 34.17 SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's: Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with rovision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General Specifications including connections with suitable size of thimbles and bonding to existing earth etc.
721(iii) 34.16 A MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10KA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
722(vi) 34.29 B Single Arm Brackets for GI Pipe Pole: (i) Supply and erection of GI pipe 40mm dia (A-class) Single arm bracket of suitable length give a total overhang at a tentative angle of 100/105 deg., the bracket should be fixed on top of the GI pipe pole having top outer dia. 80mm/100mm with GI reducer of suitable size with two coats of an approved aluminium paint complete in all respect approved by Engineer- in -charge at site:-
723(a) Capital Works 'CSR based Electrical, Instrumentation & PLC Items ( In Rs) 390147.44999999995 0.0535 20872.888574999997 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works 'CSR based Electrical, Instrumentation & PLC Items after adding 5.35% ( In Rs) 411020.33857499994 2.Capital Works ' Non-CSR based Items A. LT Panel with Starter:
724NS RUIDP ISOR 2023, 44.6 SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus.
725B. B. LT Cables & Accessories: RUIDP ISOR 2023, 60.4 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Armoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rods confirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2.5 Sq. mm (Ref: 60.4.2)
726C. C. Earthing: RUIDP ISOR 2023, 63.5 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
727D. D. Wiring, Lighting & Accessories (for Panel room, Pump House):
728NS RUIDP ISOR 2023, 66.4 Providing & Fixing of IP20, 2'x2' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in- charge. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Surface Mounting (Ref: 66.4.2)
729RUIDP ISOR 2023, 64.12 RUIDP ISOR 2023, 64.12 Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.
730RUIDP ISOR 2023, 64.11 RUIDP ISOR 2023, 64.11 Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
731RUIDP ISOR 2023, 67.12 RUIDP ISOR 2023, 67.12 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
732E. E. Level Transmitter, Magnetic Flow Meter, PLC, Pressure Gauge, Cables: RUIDP ISOR 2023, 43.27 Supply, Installation, testing and commissioning of Battery Operated Ultrasonic Level Transmitters with an accuracy of ± 0.25% of full sacle, ingress protection IP 65, MOC electronic enclosure Aluminium die cast/SS316, battery life of min. 5 years, LCD display 8 X 1 character as per technical specifications
733RUIDP ISOR 2023, 43.28 RUIDP ISOR 2023, 43.28 Supply, Installation, testing and commissioning of Battery powered Electromagnetic flow meters with GSM/GPRS based with an accuracy of ± 1% of measured value, ingress protection Electronics IP 66 and flow tube IP 68, MOC: lining Neoprene rubber/Hard rubber/PTFE, Flange - SS316/SS304/MS/CS, Electrode - SS 316/Hastalloy, Coil Housing - SS, battery life of min. 5 years, LCD display 5 digit for instantaneous flow and 9 digit for Totalized flow as per technical specifications of following sizes:
734RUIDP ISOR 2023, 47.1 RUIDP ISOR 2023, 47.1 Design, Manufacture, Supply, Installation, Testing andCommissioning of Indoor type PLC Panel of size approx. 800 mm X500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI No. 30DO No. 26AI No. 6AO No. 2MCB 16A DP No. 2MCB 6A DP No. 6SMPS 100-240VAC/ 4.5A / 24 VDC No. 1Selector Switch (Auto/Manual) & Local / Remote No. 2Control Relays Lot 1Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with No. 1Electronic Hooter No. 1Control Transformer 200VA No. 1Emergency STOP Push Button No. 1Panel Cooling Fan & Filter No. 2Panel Light with Door Switch, 7W No. 1
735RUIDP ISOR 2023, 73.41 RUIDP ISOR 2022, E111500 Providing and laying Stranded/ Flexible Annealede Bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. 1.5 sq.mm (Ref; E111540)
736RUIDP ISOR 2022, E111400 RUIDP ISOR 2022, E111400 Providing and laying Stranded/ Flexible Annealede Bare copper conductor XLPE/PVC insulated suitably laid up together overall polyster taped Al (inner sheated GI Steel wire Mylar/Drain wire) along with ATC drain wire , round/steel armoured overall PVC sheathed (ST-1) overall screened Core armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. 1.5 sq.mm (Ref; E111440)
737 Capital Works 'Non CSR based Electrical, Instrumentation & PLC Items ( In Rs) 2198671.0 Total : Part - C ( Electrical, Instrumentation & PLC ) CSR + Non CSR Amount : ( Rs) 2609691.0 Electrical Works for Sub-Station, Water Suppy- Malanwala Khaas Sr.No. Item No. Description Unit Qty Rate (Rs) Rate (Rs. In Words) Amount (Rs.) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: 1. Capital Works ' CSR based Items A. HT Cables & Accessories: 34.36 XLPE INSULATED HT CABLES: 34.36 A XLPE INSULATED HT ARMOURED CABLES (UNDERGROUND): Conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting combination in combination with copper tape (0.3KA for 1sec.) cores laid up, FR PVC inner sheathed, galvanized steel strip armoured and overall FR PVC sheathed cable confirming to IS:7098 (Part-2), 2011working voltage 11KV(E) grade to be laid 1.50 meter below ground level including excavation, sand cushioning, covering with sand & First class bricks and back filling the trench etc., of the required size:-
738(viii) 34.36 C S/E of Heat shrinkable cable end termination/ Straight through joint kit for 11 KVA /6.6 KV (E) XLPE Cables as approved & desired by Enginer in charge:-
739(viii) B. LT Cables & Accessories: 34.10 A XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1) 1988 to be laid 1 m below ground level including excavation, sand cushioning, covering with sand & first class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-
740(xxxvii)
741(xxxi) 34.10 B XLPE INSULATED ARMOURED CABLES (LOOSE): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
742(xxxvii)
743(xxxi) 34.25 CABLE TRAY: Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
744(ii) 34.37 DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: 34.37 B Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2 mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
745(iv) 34.38 C Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections.
746(iii)
747(xiii) 34.38 A Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
748(xi) C. Earthing: 34.13 (xiv) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. To make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling).
74934.13 (xx) Capital Works 'CSR based Electrical, Instrumentation & PLC Items ( In Rs) 699358.7000000001 0.0535 37415.69045 Add 5.35% on CSR-Punjab-2022 items on account of change in GST rates for work contracts approved under Agenda item no.1 in the meeting of direction committee of Chief Engineers on dates 28-02-2023 and is issued vide memo No.2433-2452 /CSR dated 02-03-2023 Capital Works 'CSR based Electrical, Instrumentation & PLC Items after adding 5.35% ( In Rs) 736774.3904500001 2.Capital Works ' Non-CSR based Items A. HT System:
750RUIDP ISOR 2023, 72.4
751RUIDP ISOR 2023, 72.4
752RUIDP ISOR 2023, 72.7.2
753RUIDP ISOR 2023, 72.7.3 RUIDP ISOR 2023, 72.2 SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.
754B. B. LT Panels:
755NS C. DG Set & AMF Panel: RUIDP ISOR 2023, 72.17 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,H & IA) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP (up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or above required ) capable of taking 10% over loading for one hour after 12 hours of continuous operation., Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber), up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required .B) AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade.D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA.F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.G) Servicing Contract of DG Set from OEM's Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department.H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration.I) DG set will be offered for Inspection and Testing at Manufacturer's Works in presence of Departmental Engineers. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
756RUIDP ISOR 2023, 72.29 RUIDP ISOR 2023, 72.29 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
757NS D. Earthing: RUIDP ISOR 2023, 63.5 Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
758E. E. Outdoor Lighting: RUIDP ISOR 2023, 67.7 Supply installation testing & Commissioning of high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly ) foundation bolt, torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required on Existing Foundation. ( See table P - 03 for specs.) OEM Must have Type test certificate for wind tunnel test . All as per pre approved by Engineer in-charge. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.
759RUIDP ISOR 2023, 67.11 RUIDP ISOR 2023, 67.11 Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR.
760 Capital Works 'Non CSR based Electrical, Instrumentation & PLC Items ( In Rs) 5060779.0 Total : Part - C ( Electrical, Instrumentation & PLC ) CSR + Non CSR Amount : ( Rs) 5797553.0 SCADA for Intake, Raw & Clear water Pumping Station, WTP & Sub-Station- Malanwala Khaas Sr.No. Item No. Description Unit Qty Rate (Rs) Rate (Rs. In Words) Amount (Rs.) Supply, Installation, testing and commissioning of the following items complete in all respect and as per scope of work, specification and as required at site: Capital Works ' Non-CSR based Items
761RUIDP ISOR 2023, 47.14 Capital Works 'Non CSR based SCADA Items ( In Rs) 4339666.0 Total : Part - C ( SCADA ) Non CSR Amount : ( Rs) 4339666.0 5 years’ Operation and Maintenance (Part-2) of 5.0 MLD Water Treatment Plant (WTP) and other related works at Town : Mallanwala Khass Town, District Ferozepur, Punjab under AMRUT 2.0 Scheme 5 Years' Operation & Maintenance Cost (PART 2) S. No. Period Unit Total Qty Rate Amount in Rs Amount In words (In Rupees) (In Rs)
762Construction period (30 Months)
7631st Year.
7642nd Year.
7653rd Year.
7664th Year.
7675th Year. Total 5 Years' O&M in Rs 17632400.36 One Crores Seventy Six Lacs Thirty Two Thousand Four Hundred Rupees and Thirty Six Paise

AI Tender Summary

OUR REF NO 55459766
AUTHORITY Government Departments
TENDER VALUE 16.94 Crore
LAST DATE 08-07-2026
Authority
Authority Name Punjab Water Supply And Sewerage Board
Work Description Tender for Canal Water Based Water Supply Project For Construction Of 5.0 Mld Water Treatment Plant (Wtp) And Other Related Works Including 5 Years Operation And Maintenance (Part-2) At Mallanwala Khass, District : Ferozepur, Punjab Under Amrut 2.0 Scheme
Basic Detail
Tender No E Tender Notice No 90 (WTP Mallanwala)
Bidding Type Tender
Location
City Ferozepur
State Punjab
Key Dates
Publish Date 30 Jun 2026
Submission Date 08 Jul 2026
Open Date 08 Jul 2026
Finance
Tender Value 16.94 Crore
Tender Fee 1000
EMD 16.94 Lakhs
Exemption Not Available
Document List
BOQ.xls
e9a2de59-693e-4c97-ad89-54997b6c7f0f.html
ETENDERNOTICENO90.pdf
MAP1.pdf
MAP2.pdf
MAP3.pdf
MAP4.pdf
MAP5.pdf
MAP6.pdf
MAP7.pdf
MAP8.pdf
MAP9.pdf
Tendernotice_1 (9).pdf
VOLUME1MALLANWALA.pdf
VOLUME2MALLANWALA.pdf
VOLUME3MALLANWALA.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 23, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 23, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 08, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Jul 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ.xls

html

e9a2de59-693e-4c97-ad89-54997b6c7f0f.html

pdf

ETENDERNOTICENO90.pdf

pdf

MAP1.pdf

pdf

MAP2.pdf

pdf

MAP3.pdf

pdf

MAP4.pdf

pdf

MAP5.pdf

pdf

MAP6.pdf

pdf

MAP7.pdf

pdf

MAP8.pdf

pdf

MAP9.pdf

pdf

Tendernotice_1 (9).pdf

pdf

VOLUME1MALLANWALA.pdf

pdf

VOLUME2MALLANWALA.pdf

pdf

VOLUME3MALLANWALA.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders