| 1 | CIVIL |
| 2 | 2.6.1Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.All kinds of soil |
| 3 | 4.1.8Providing and laying in position cement concrete of specified grade excluding thecost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 4 | 5.9.1Centering and shuttering including strutting, etc. and removal of formfor:Foundations, footings, bases of columns, etc for mass concrete |
| 5 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete upto plinth levelThermo - Mechanically Treatedbars of grade Fe-500D or more |
| 6 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources) |
| 7 | 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 8 | 2.25Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundation etc. in layers not exceeding 20 cm in depth, consolidating each depositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 9 | Electrical Work |
| 10 | 90.15.2.2Supply installation testing and commissioning of High Mast using Octogaonal Polemade single/two sections of hot dip galvanised GI sheet 70mm top diameter, 130mmbottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitablefor wind speed as per IS 875 Part III with head frame assembly two point suspensionsystem with steel wire rope 5mm dia double drum winching system w and includinground arm galvanized luminary carriage suitable to install 6/8 nos luminaries insymmetrical arrangement control gear box and lighting spikes with single phaseoperation power tool installed inside the base compartment including connectorfoundation bolt 4 nos fixed in existing RCC foundation and junction box etc,complete 10 Meters |
| 11 | 90.15.4.9Installation, testing and commissioning of 150W LED Floodlight output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chipmake Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internalsurge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartmentshould be seperatly accessible for maintenance (LM 79&80 certificates from NABLaccredited Third party lab to be produced mentioning chip manufacturer) |
| 12 | OD187621/2025-2026Supply and installation of Twin unit aviation LED obstruction light with standyellow-painted die-cast aluminium alloy housing, red coloured polycarbonate dome and BC /EC lamp holderssuitable for LED lamp |
| 13 | OD187742/2025-2026Supply and fabrication conveyance and installation of Feeder Pillar Sintex BoxDouble Door.. |
| 14 | OD187745/2025-2026Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digitaltimer, Suitable Copper socket, 2.5 sq. mm ISI marked FRLS PVC insulated singlecore copper conductor cable, 1.5 sq. mm ISI marked FRLS PVC insulated single corecopper conductor cable, OBO Bettermann makes V25-B+ C/1+ NPE(switching/lightning protection) for single-phase protection. |
| 15 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 16 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 17 | 2.10.3Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 18 | OD188287/2025-2026Supply and fixing HRC fuse base of 20/32 A using suitable nut and bolt, 32 A 2-wayneutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVCinsulated single core copper conductor cable.. |
| 19 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 20 | OD187622/2025-2026Supply and fixing of 2 nos.of 25A 3 Pole AC 1 rated power contactor, Selector switchfor motor control, supply and fixing flush head push button NO-NC and 2.5 sq. mm ISI sq. mm ISImarked FRLS PVC insulated single core copper conductor cable. |
| 21 | 90.6.5.11Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVCsheathed 650/1100 V grade copper conductor round flexible cables conforming to IS694 part I 1960 in the existing surface / recess conduit as required including givingnecessary connections of the following sizes.3 core 1.50 sq mm |
| 22 | 90.6.5.12Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conformingto IS 694 part I 1960 in the existing surface / recess conduit as required includinggiving necessary connections of the following sizes.3 core 2.50 sq mm |
| 23 | 5.1Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with cover plate having locking arrangement andwatering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 24 | 90.16.4.2Supply and clamping the following sizes of strips on surface of wall / parapet/existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted orheavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good thedamages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip |
| 25 | 90.16.1.3Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required3.15 mm copper conductor ( 10SWG) |
| 26 | 90.16.5.3Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.3.15 mm (10 SWG) |
| 27 | 90.12.5.3Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm |
| 28 | 90.12.9.2Supplying, laying and jointing of the following sizes of double wall corrugated(DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanicalprotection to underground power cables with all required accessories in ground in theexisting trench50/38 mm or nearest size |
| 29 | 9.1.2Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.2 X 10 sq. mm (19mm) |
| 30 | OD187619/2025-2026Fabrication,supply, conveyance and installation of granite board indicating the costInvolved,commencement,completion and inauguration. |
| 31 | OD187623/2025-2026Supply and fixing of Name Board with Angles ,Flats, Square Pipe, ACP Sheet(complete 4 sides) includingNut and bolt. |
| 32 | Connection charges - KSEB Please Enable Macros to View BoQ information |