| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-(As per TSR 2021, Sl- 201) |
| 2 | Short point:- |
| 3 | Medium point:- |
| 4 | Long point:- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-(As per TSR 2021, sl No:-203) |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-(As per TSR 2021, sl No:-204) |
| 7 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required:- (As per TSR 2021 Sl- 205) |
| 8 | 2 x 1.5 sq.mm |
| 9 | 2 x 2.5 sq.mm |
| 10 | 2 x 4 sq.mm |
| 11 | 4 x 6 sq.mm |
| 12 | 4 x 10 sq.mm |
| 13 | 4 x 16 sq.mm |
| 14 | Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required:- (As per TSR 2021 Sl- 205) |
| 15 | 1 x 1.5 sq.mm |
| 16 | 1 x 2.5 sq.mm |
| 17 | 1 x 6 sq.mm |
| 18 | 1 x 10 sq.mm |
| 19 | Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:-(As per TSR 2021, sl No:-717) |
| 20 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.(As per TSR 2021, sl No:-706) |
| 21 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. (As per TSR 2021, sl No:-710) |
| 22 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - (As per TSR 2021, sl No:-802) |
| 23 | Supplying and fixing of the following modular accessories including necessary connection etc. as required.(As per TSR 2021, sl No:-609) |
| 24 | a. 5 step fan regulator (2M):- |
| 25 | b. 20/25 amps single phase motor starter switch (2M):- |
| 26 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required.(As per TSR 2021, sl No:-604) |
| 27 | a. Remote controlled call bell |
| 28 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-(As per TSR 2021, sl No:-816) |
| 29 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-(As per TSR 2021, sl No:-821) |
| 30 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:-(As per TSR 2021, sl No:-831) |
| 31 | Supplying of 400 mm sweep AC wall mounting fan with metal blade etc as required:-(As per TSR 2021, sl No:-810) |
| 32 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021, sl No:-1101) |
| 33 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 34 | Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 35 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-(As per TSR 2021, sl No:-1103) |
| 36 | a. 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):- |
| 37 | b. 5 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 38 | c. 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 39 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-(As per TSR 2021, sl No:-1001) |
| 40 | a. Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 41 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021, sl No:-1102) |
| 42 | a. 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 43 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(As per TSR 2021, sl No:-1501) |
| 44 | a. 40 mm dia |
| 45 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -(As per TSR 2021, sl No:-1405) |
| 46 | a. 1.5 sqmm - 4 sqmm Cable:- |
| 47 | Supplying and installation of change over switch of following ratings with enclosure including necessary connection etc. as required:-(As per TSR 2021, sl No:-1204) |
| 48 | a. 63 amps FP on load change over switch (Front handle with enclosure):- |
| 49 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-(As per TSR 2021, sl No:-1202) |
| 50 | a. 200 amps 415 volts TPN main switch (rewireable):- |
| 51 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.(As per TSR 2021, sl No:-1208) |
| 52 | a. 4 way SPN MCB DB (single door):- |
| 53 | b. (2+6) / 8 way SPN MCB DB (single door):- |
| 54 | c. 4 way horizontal TPN MCB DB (Single door):- |
| 55 | d. 6 way horizontal TPN MCB DB (Single door):- |
| 56 | e. 4 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):- |
| 57 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-(As per TSR 2021, sl No:-1215) |
| 58 | a. 6 to 32 amps SP MCB:- |
| 59 | b. 6 to 32 amps DP MCB:- |
| 60 | 40/50/63 amps TPN MCB:- |
| 61 | d. 40/50/63 amps FP MCB:- |
| 62 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-(As per TSR 2021, sl No:-1219) |
| 63 | a. 125 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :- |
| 64 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required.(As per TSR 2021, sl No:-1301) |
| 65 | 3 core 4 Sq mm |
| 66 | Drawing of armoured/un-armoured cable with proper saddling etc as required:-(As per TSR 2021, sl No:-1511) |
| 67 | Supplying & installation of Astronomical timer Switch including necessary connection etc as required:-(As per TSR 2021, sl No:-1513) |
| 68 | Supplying & installation of following power contactors including necessary connection etc as required:-(As per TSR 2021, sl No:-1514) |
| 69 | a. 3 pole 9 amps (AC3) power contactors with 1NO+1NC Aux. Contact. |
| 70 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : -(As per TSR 2021, sl No:-1401) |
| 71 | 4/6 sq mm |
| 72 | 10 sq mm |
| 73 | 16 sq mm |
| 74 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-(As per TSR 2021, sl No:-1502) Please Enable Macros to View BoQ information |