Housing Urban and Rular Development Government Departments Closing in 0 days TDR #55452066

Tender For Renovation Of electrical installation Work For The Cmo Office, Kailashahar, Unakoti Tripura.

Issued by Government Departments · Kailashahar, Tripura
Tender Value
10.62 Lakhs
Estimated cost
Bid Submission
18 May 2026
0 days left
EMD
21249
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kailashahar → Tripura
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Renovation Of electrical installation Work For The Cmo Office, Kailashahar, Unakoti Tripura.

BOQ

Name of Work:- Renovation of E.I work for the CMO office, Kailashahar, Unakoti Tripura.
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:-(As per TSR 2021, Sl- 201)
2Short point:-
3Medium point:-
4Long point:-
5Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-(As per TSR 2021, sl No:-203)
6Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-(As per TSR 2021, sl No:-204)
7Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required:- (As per TSR 2021 Sl- 205)
82 x 1.5 sq.mm
92 x 2.5 sq.mm
102 x 4 sq.mm
114 x 6 sq.mm
124 x 10 sq.mm
134 x 16 sq.mm
14Wiring for Circuit/Sub-main wiring with the following sizes PVC insulated copper conductor cable (FR) in PVC casing capping etc. as required:- (As per TSR 2021 Sl- 205)
151 x 1.5 sq.mm
161 x 2.5 sq.mm
171 x 6 sq.mm
181 x 10 sq.mm
19Providing earthing system with maintenance free earthing electrode of 50 mm dia & 3 mtr long of dual electrode technology filled with highly conductive compound and back fill compound of 2 nos. 25 kg bag, terminal size 32mmx 6mm including accessories with masonry enclosure of CI cover plate size 12\\"x 12\\" having locking arrangement including CC works etc as required:-(As per TSR 2021, sl No:-717)
20Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.(As per TSR 2021, sl No:-706)
21Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. (As per TSR 2021, sl No:-710)
22Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - (As per TSR 2021, sl No:-802)
23Supplying and fixing of the following modular accessories including necessary connection etc. as required.(As per TSR 2021, sl No:-609)
24a. 5 step fan regulator (2M):-
25b. 20/25 amps single phase motor starter switch (2M):-
26Supplying and fixing of the following electrical accessories including necessary connection etc. as required.(As per TSR 2021, sl No:-604)
27a. Remote controlled call bell
28Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-(As per TSR 2021, sl No:-816)
29Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-(As per TSR 2021, sl No:-821)
30Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required:-(As per TSR 2021, sl No:-831)
31Supplying of 400 mm sweep AC wall mounting fan with metal blade etc as required:-(As per TSR 2021, sl No:-810)
32Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021, sl No:-1101)
33Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
34Surface mounted round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
35Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-(As per TSR 2021, sl No:-1103)
36a. 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
37b. 5 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
38c. 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :-
39Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-(As per TSR 2021, sl No:-1001)
40a. Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : -
41Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021, sl No:-1102)
42a. 60 watt LED street light fixture with integral driver and secondary lens (IP 66):-
43Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(As per TSR 2021, sl No:-1501)
44a. 40 mm dia
45Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -(As per TSR 2021, sl No:-1405)
46a. 1.5 sqmm - 4 sqmm Cable:-
47Supplying and installation of change over switch of following ratings with enclosure including necessary connection etc. as required:-(As per TSR 2021, sl No:-1204)
48a. 63 amps FP on load change over switch (Front handle with enclosure):-
49Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-(As per TSR 2021, sl No:-1202)
50a. 200 amps 415 volts TPN main switch (rewireable):-
51Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.(As per TSR 2021, sl No:-1208)
52a. 4 way SPN MCB DB (single door):-
53b. (2+6) / 8 way SPN MCB DB (single door):-
54c. 4 way horizontal TPN MCB DB (Single door):-
55d. 6 way horizontal TPN MCB DB (Single door):-
56e. 4 way vertical TPN MCB DB suitable for FP MCB incomer (Double door):-
57Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-(As per TSR 2021, sl No:-1215)
58a. 6 to 32 amps SP MCB:-
59b. 6 to 32 amps DP MCB:-
6040/50/63 amps TPN MCB:-
61d. 40/50/63 amps FP MCB:-
62Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-(As per TSR 2021, sl No:-1219)
63a. 125 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :-
64Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required.(As per TSR 2021, sl No:-1301)
653 core 4 Sq mm
66Drawing of armoured/un-armoured cable with proper saddling etc as required:-(As per TSR 2021, sl No:-1511)
67Supplying & installation of Astronomical timer Switch including necessary connection etc as required:-(As per TSR 2021, sl No:-1513)
68Supplying & installation of following power contactors including necessary connection etc as required:-(As per TSR 2021, sl No:-1514)
69a. 3 pole 9 amps (AC3) power contactors with 1NO+1NC Aux. Contact.
70Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : -(As per TSR 2021, sl No:-1401)
714/6 sq mm
7210 sq mm
7316 sq mm
74Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:-(As per TSR 2021, sl No:-1502) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55452066
AUTHORITY Government Departments
TENDER VALUE 10.62 Lakhs
LAST DATE 18-05-2026
Authority
Authority Name Public Works Department
Work Description Tender for Renovation Of electrical installation Work For The Cmo Office, Kailashahar, Unakoti Tripura.
Basic Detail
Tender No 06/EE-IED/AMB/2026-27
Bidding Type Tender
Location
City Kailashahar
State Tripura
Key Dates
Publish Date 12 May 2026
Submission Date 18 May 2026
Open Date 19 May 2026
Finance
Tender Value 10.62 Lakhs
Tender Fee 1000
EMD 21249
Exemption Available
Document List
24fe6845-988b-47cc-b550-11929f716865.html
BOQ_74053.xls
DNIT06.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
May 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

24fe6845-988b-47cc-b550-11929f716865.html

xls

BOQ_74053.xls

pdf

DNIT06.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail