| 1 | Metering Equipment and Fencing |
| 2 | OD60760/2025-2026:Isolating the 11 kV supply to the 4 pole structure, earthing using earthing chain, taking all safety measures, attending Minor repairs to the electrical connections of the 11 KV four pole structure such as correcting loose connections in the jumpers, lead wires re arrangement of the existing accessories including using necessary copper wires of adequate size, overall inspection of HT and LT connections ,attending petty repairs at jumper connections ,insulators, lightning arrestors D.O fuses replacing nuts and bolts if any where ever necessory on the 4 ploe structure and correcting the system in good condition |
| 3 | OD60756/2025-2026:Supply, conveyance, erection testing and commissioning of approved make 11 KV, out door metering CT PT unit wit 3 CT ratio 10/5A to 50/5A 10/15 VA, class 0.2 S class and PT ratio 11 KV/110 V , 25 VA, class 0.2 class , suitable for 3 phase 4 wire system of metering (the unit shall be tested in KSEB TMR division and test certificate should be submitted before installation) erecting the same in cross arm channel support with all standard accessories, giving connections as required. including conveyance charges to & fro for testing , after dismantling the damaged one |
| 4 | OD60758/2025-2026:Supply, conveyance, erection testing and commissioning of approved make 3 phase, 4 wire, 110 V ( L-L), -/1 A CT or -/5A CT with DLMS compliant, having RS 485 port of class 0.2 S class TOD meter in the existing meter box after submitting the test certificate from KSEB TMR Division, giving all connections etc. as required. (excluding testing fees) |
| 5 | OD60755/2025-2026:Supply,Erection, testing and commissioning of 3 phase 4 wire 12 way panel mounting front screw type brass test terminal block for interconnection. |
| 6 | OD60759/2025-2026:Supply, conveyance, fitting and commissioning of approved make 11 KV,400 Amps, out door type gang operated, Polymer type Air Break triple pole switch (3 piece full set) with all necessary accessoriesincluding adequate length of GI pipe as operating lever, operating handle with insulation and locking arrangements on suitable height, with necessary clamps, nut, bolt, washer etc. asrequired. |
| 7 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 8 | 13.13:Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire. 11 KV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanized clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 9 | OD60757/2025-2026:cutting and removing the grass / bushes/ creeping plants in the transformer yard, and dumping them in convenient place and cleaning the yard from all other vegetation growth as per the direction of departmental staff at site |
| 10 | OD169547/2025-2026:charges for testing TODmeter,CT/PT units and getting certificate from KSEB TMR division ( actual amount will be paid on submitting original bill) |
| 11 | HT Maintenance work |
| 12 | OD60762/2025-2026: Isolating the Transformer from HT Line after taking permission from KSEB authorities, Earthing the HT Terminals of the transformer, using earthing chain, and taking all safety measures, Scrapping, cleaning the surface of the transformer, painting the surface with enamel paint, over a coat of zinc rich primer, painting the four pole structure and yard fencing with two coats fo anti corrosive aluminium paint over a coat of synchromite primer after cleaning the surfaces etc. as per the direction of the departmental officers at site. |
| 13 | 13.10:Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required |
| 14 | 13.11:Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 15 | OD60764/2025-2026:Charges for filtering the transformer oil reconditioning the same for getting the appropriate dielectric strength checking oil filter, correcting bush terminals making leak proof condition refilling the reconditioned oil to the required level etc. complete through competent agency into satisfactory working condition as per the direction from the departmental staff at site. |
| 16 | OD60766/2025-2026:Supply, conveyance, fitting and commissioning of approved make 11 KV, Drop Out Fuse Unit with all standard accessories in the existing GI / MS channel, properly fixing on cross arm including giving connections etc. as required. |
| 17 | OD60765/2025-2026:Filling of Transformer Oil in the existing Transformer as required |
| 18 | OD127089/2025-2026:Supply and renewing Oil gasket on 250KVA transformer after opening the top cover and minor repairs. |
| 19 | OD127090/2025-2026:Supply and renewing the damaged Breather of 250 KVA transformer as per the direction from the department staff as required |
| 20 | OD127091/2025-2026:Supply and renewing damaged HT Bush, nut bolt and washers of 250 KVA transformer as per the direction from the department staff. |
| 21 | OD127092/2025-2026:Charges for dismantling 250 KVA transformer for minor repairs drain out the transformer oil and conduct the Cleaning of winding and bushes from dust and dirt deposition on both HT and LT sides, attending minor repairs/replacing the damaged Oil gasket, HT/LT bushes, Breather using fresh materials (excluding supply) and refill the transformer oil to the tank etc complete including conducting test run as required as per the direction from the department staff. |
| 22 | OD127087/2025-2026:Hire and running charges of 33KVA DG set including Up and Down conveyance with operator Please Enable Macros to View BoQ information |