| 1 | Supply and Erection of 2.5” dia. GI Pipe pole 4.5 Mtrs longSupply, Fabrication & erection of 2.5” dia G.I. pipe pole having length 4.5 long, B class (medium) ISI marked. The pole shall be erected 3’ below ground level in 8” dia. RCC muff readymade. The gap between the pole and muff shall be filled with cement concrete in ratio of 1:2:4 and making required no. of holes in the pole including carriage of pole to the site of work including all labour and material required to complete the job including suitable size of nipple welded with the pipe. Make TATA / Jindal . The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 2 | Supply & Laying of flexible PVC insulated FR PVC sheathed 3 Core 1.5 mm2 Copper Cable conforming to IS -694:2010 of make KEI,Havells ,Cirtina / finolex , Polycab within the9 mtr Steel tubular / Octagonal pole and within bracket fitted on pole.The job include the cost of other petty material required to complete the job to the entire satisfaction of engineer –in – change precautions of the work. |
| 3 | S/E of Collars of CC Collars including following:- a) The box shall be enclosed in a cement collar made form cement concrete 1:2:4 with outside dia. 16”.b) The collar shall be embedded in the ground up to 6” shall stand 9” above ground shall have housed 10” high SMC Box and 6” top over the box.c) The collar shall be provided with 2 PVC Pipes of 40mm dia. and 45cm long to facilitate entry of cables in the Jn.Box.d)n The collar shall be plastered properly finished, curing and painted with 2 coats of snowcem of superior quality. (e) Providing and Fing Junction box of size 250x200x100mm inside dimensions of thermosetting sheet moulding compound material of robust construction with double hinge, side clamp locking arrangement, provision for MCB/Kit installatin provision alongwith connector strip of 30 amps rating suitable for minimum 4x16 sq.mm aluminium cable termination. The junction box should have two numbers PVC Glands with sufficient space for cable entry and loose wires complete in all respect to the best satisfaction of Engg.in.charge. |
| 4 | Supply & Laying of DWC pipe 50/63mm with out hand bockey:-Supply and laying of 50/63 mm (I/D& O/D) Double Wall Corrugated (DWC) High Density Polyethylene pipe (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm conforming to IS 14930 (P-II) and PSEN-50086 (P-I & II) of Make Duraline/Rex/Zen duct /Gemini.. The pipe should be laid below ground/road level by digging the ground upto75 cm less excavation or cutting the road/paver blocks upto required level & laying of DWC pipe for laying L.T. (up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respects to the entire satisfaction of Engineer-in-Charge of work. |
| 5 | PAINTING & NUMBERING OF POLES 4.5 Mtr. LONG - 6 M Long: -Painting of poles above ground level with two coats of Al paint of Nerolec/Asian/ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/rust & other depositions Numbering on the pole be done on two sides on each pole with yellow and the number should be written in black letters of 3” in length.The Cement collar around the pole should be painted with two coats of good quality white colored snowcem. The job includes the cost of paint of existing Junction box cover with Red paint and any other petty material require to complete the job to the entire satisfaction of Engineer-in-charge |
| 6 | PAINTING & NUMBERING OF POLES 10/11 Mtr. LONG: -Painting of poles above ground level with two coats of Al paint of Nerolec/Asian/ICI duly approved by the Engineer-in-charge. The pole surface should be cleaned well by removing dust/rust & other depositions & smoothened with the sand paper/Iron brush & proper filling be made before painting. For numbering of poles the base should be painted with yellow and the number should be written in black letters of 3” in length. |
| 7 | Supply & laying of ISI marked 4 core 16 mm sq PVC INSULATED Aluminium armoured cable loose in trench/ pipe:-Supply & laying of ISI marked 4 core 16 mm sq Aluminum conductor armoured cable of make Havell's/ Finolex/ Ecko/ Lapp/ Cirtina/ Polycab/ KEI conforming IS:1554 (Pt.1) amended. The cable shall be laid as per DSR Code 7.5.1 . The job included all Connections, Commissioning and testing of phase. Supply complete in all respective to the entire satisfaction of the Engineer in charge. |
| 8 | G.I. Earth pipe electrode with salt/ Charcoal:-Supply and laying of earth electrode made out of ISI marked 'B' class G.I. pipe 4.5 Mtr. long 40 mm dia including accessories. GI pipe electrode shall be cut tapered at the bottom, and provided with holes of 12mm dia, drilled not less than 7.5 cm from each other upto 2 Mtr. of length from bottom. The earth electode shall be laid in ground after boring as per CPWD specifications complete in all respect and to the entire satisfaction of the engineer-in-charge. |
| 9 | P/F 6 SWG GI earth wire in pipe: Providing & laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode, as required. |
| 10 | Supply and Fixing Triple Pole 63 Amps, 415 Volts MCCB Complete with connections testing and commissioning Etc as required |
| 11 | Painting of pedestal size 1200x900x350mm with P.O. red paint complete in all respect and bonding to the existing earth etc. and platform of cement concrete 1:2:4 around the pillar box of size 3’x2’x0’-4”. The work shall be executed to the entire satisfaction of Engineer-in-Charge. |
| 12 | Erection of LED Street Light/ Flood Light/ Globe Light on wall complete in all respect to the entire satisfaction of Engineer-in-charge. Please Enable Macros to View BoQ information |