| 1 | Dressing of earth work in surface excavation including cutting andfilling upto 30cm depth including disposal of excavated earth upto50m and lift upto 1.5 m. |
| 2 | Construction of embankment with approved material obtained fromborrow pit with all lifts and leads, transporting to site, spreading,grading to required slope and compacting by vibratory roller 8-10tonne to meet requirement of table 300-2 including cost ofcompensation for earth taken from private land complete as perMoRT&H specification clause 305. (Lead taken upto 5 km) |
| 3 | Providing, laying and spreading of granular sub-base by providingcoarse graded Material (Table 400-2), spreading in uniform layerswith motor grader on prepared surface, mixing BY MIX IN PLACEMETHOD with rotavator at OMC, and compacting with vibratoryroller to achieve the desired density, complete as per MoRT&Hspecification clause - 401 including all material, labour, machinery,lighting, guarding and maintenance of diversion.Grading - II Material |
| 4 | Providing and laying lean cement concrete 1:4:8 in Sub- base over aprepared sub-grade with coarse and fine aggregate conforming toIS: 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 15:1, aggregate gradationafter blending to be as per table 600-1, cement content not to beless than 150 kg/ cum, optimum moisture content to be determinedduring trial length construction, concrete strength not to be less than10 Mpa at 7 days, mixed in a batching plant, transported to site, laidwith a paver with electronic sensor, compacting with 8-10 tonnesvibratory roller, finishing and curing complete as per clause 601, 112of MoRT&H specification including all material, labour, machinery,lighting, guarding and maintenance of diversion. |
| 5 | Providing and laying un-reinforced, plain cement concrete mix withConcrete Mixer & vibrator pavement over a prepared sub base with43 grade cement , coarse and fine aggregate conforming to IS: 383,maximum size of coarse aggregate not exceeding 25 mm, mixed asper approved mix design, laid, spread, compacted and finished in acontinuous operation including provision of contraction, expansion,construction and longitudinal joints etc including all material, labour,machinery, lighting, guarding and maintenance of diversion.PCC M-20 |
| 6 | Providing and fixing of 60mm thick precast cement concreteinterlocking paver block casted with rubber moulds in approvedreflective colour and design having minimum compressive strengthof 300 kg/ sq cm. The CC paving blocks be laid on average 50mmthick bed of coarse sand and the joint is to be filled with fine sand.Laying procedure on compacted sub-base as defined. Complete jobis to be executed as per the instruction of Engineer in-charge. Therates to be inclusive of all lead & Lifts etc. complete as perspecifications. |
| 7 | Centring and shuttering with plywood or steel sheet upto two stories( each story of height upto 3.5 metre from floor level) includingstrutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete. |
| 8 | Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in positionand applying a priming coat of approved steel primer all complete: |
| 9 | Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two or more coat applied @0.90 ltr/10 sqm over an undercoat of primer applied @ 0.80 ltr/ 10 sqm of approved brand ormanufacture |
| 10 | Finishing walls with water proofing cement paint of required shade :Old work (one or more coats applied @ 2.20 kg/10 sqm) overpriming coat of primer applied @ 0.80 litrs/10 sqm completeincluding cost of Priming coat. |
| 11 | Finishing walls with Acrylic Smooth exterior paint of required shade:Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 12 | Supply at site of work well decayed farm yard manure, from anyavailable source, approved by the engineer in-charge includingscreening and stacking |
| 13 | Grassing with 'Doobs' grass including watering and maintenance ofthe lawn for 30 days or more till the grass forms a thick lawn freefrom weeds and fit for moving including supplying good earth ifneeded. (The good earth shall be paid separately)In rows 7.5 cm apart in either direction |
| 14 | Labour Charges for Grassing with 'Carpet' grass (selection no.1)/'Doobs' grass including watering and maintenance of the lawn for30 days or more till the grass forms a thick lawn free from weedsand fit for moving including supplying good earth if needed.(Thegood earth shall be paid separately)In rows 5 cm apart in either direction |
| 15 | Making lawns including ploughing and breaking of clod, removal ofrubbish, dressing and supplying doobs grass roots and planting at15 cm apart, including supplying and spreading of farm yardmanure at rate of 0.18 cum per 100 sqm. |
| 16 | Maintenance of lawns or Turfing of slopes (rough grassing) for aperiod of one year including watering etc. |
| 17 | Planting permanent hedges including digging of trenches, 60 cmwide and 45 cm deep, refilling the excavated earth mixed withfarmyard manure, supplied at the rate of 4.65 cum per 100 metresand supplying and planting hedge plants at 30 cm apart. |
| 18 | Maintenance of Hedge for one year |
| 19 | Transplantation of trees with in a distance of 2km includingexcavation around existing tree, pruning of branches, lifting, loadingand transportation of existing tree, digging pits for placingtree at new place, adding manure, sand, fertilizer, hormones andbio fertilizer to it. Levelled and neatly dressed and disposal ofsurplus materials from old existing and new sites to designatedplace. Each tree should be firmly secured to the stake so as toprevent excessive movement, flooding with water, treatment ofroots, rope and gunny bags as per direction of the officer in-charge.T&P and all required materials shall be arranged by the contractorand nothing extra shall be paid on this account.NOTE: Girth of tree shall be measured at a height of 1m aboveground level.Girth of trees beyond 50cm and upto 90cm. |
| 20 | Supplying, erecting and fixing in position specified precast RCCbench made of RCC grade M-30 consisting of 2 Nos. “L” shapedbase support of thickness 100 mm back height 1000mm, front height450 mm, base width 420mm and 5 Nos. RCC planks of size of1500x100 x 50 mm and 1 Nos RCC planks of 150x200x50mmincluding joining all parts with galvanised nuts and bolts of suitablesize. All bolts to be sealed after assembly with nice finish andappearance and level complete in all respect as per direction ofengineer in-charge. Every bench should have a manufacturer’s logoof appropriate size Engraved at suitable place. |
| 21 | Supply and fixing different type of steel pre-fabricated garden bench/jhula/ slides and other children play items made of steel duly paintedas per approved design and specifications by engineer in-chargemade of MS pipe, Flats, rectangular hollow section or other steelsections duly welded and or nut bolted where ever required, rubbingand buffing welded joints to make safe for use of children andpainted in approved pattern complete as required. |
| 22 | Supply of P.V.C. hose pipe of different sizes at store includingtransportation etc complete :25 mm dia |
| 23 | Construction of Tube-well upto 100 Meter depth and above in alltype of rocks by DTH system and over burden to accommodatecasing pipe of following sizes in all types of soils and over burdenincluding lowering of casing pipes but excluding cost of casing pipesas per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well shouldhave a throughout bore as per nominal dia of casing pipe:150 mm dia Nominal bore |
| 24 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/1992) of grade Fe410 of following nominal bore sizes at site of work.150 mm dia |
| 25 | Development of tube well as per IS specification using suitablecompressor to give sand free water for required yield of the gravelpacked tube well. |
| 26 | Labour charges for installation of submersible motor pump setincluding lowering/ delowering of pipes, cables, accessories etc. intube-well/ open well complete including T&P, transportation of tripod,chain pulley block & any other material required for this purpose complete in all respect.Delowering and Lowering |
| 27 | Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 forwater supply suitable for submersible & jet pump with requiredfittings ie socket, elbows, tee etc. complete in all respect. All as perpre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR .40 mm OD 6 kg / cm2 |
| 28 | Providing & Laying of Polypropylene rope Confirming to IS:5175 for submersible pump of following sizes. complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .12mm (suitable up to 50 mm OD pipe) |
| 29 | S & F of STAR DELTA STARTER IN THE EXISTING PANEL WITH FOLLOWING RATING7.5 KW to 9.3KW |
| 30 | Supply and fixing of tube well cover of M.S. sheet (6mm thick) with nuts and bolts complete for casing size:150 mm dia |
| 31 | Supply and fixing of M.S. clamp set of 50 ×6mm flat iron with nutsand bolts etc. for holding the riser pipe assembly of submersible pump set. |
| 32 | Providing & lowering of G.I. flange pipe B Class including rubberwasher and nuts of 8 mm dia complete in all respect.50 mm dia |
| 33 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Unarmoured Copper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Copper made of copper rodsconfirming to IS 613-1964, of purity >99.7 %, Inner / outer sheathconfirming to IS:5831 in existing RCC / Hume / Stoneware / PVCpipe/ open duct/cable trench / Cable tray (with cable tie) includingtesting etc. as required of following size. OEM must have it's own inhouse NABL accrediated Laboratory for testing procedure as perIS:10810 For additional technical parameters of product / work referAnnexure 'A' attached with this BSR.4.0 Sq mm 2 core |
| 34 | SITC of Radial / mixed flow ISI marked water and anti-corrosiveliquid filled submersible motor pump sets suitable for 100/150mmdia borewell. The size of adopter fixed on top of the motor shouldexceed the top of coupler , for safegaurd the coupler. Theconstruction material of motor and pump should match IS: 8034 :2018 and IS: 9283 guideline. The radial flow pumpset shouldoperate at 5 star energy efficiency level of BEE and mixed flowpump set should operate at 3 star energy level of BEE,accompained by valid BEE certificate. Motor should be IE2 class asper IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011with required accessories including making connection suitable forBore well. The job includes labour part of lowering of riser pipe G.I./H.D.P.E. with rope, cables & pump, installation of complete fittingand accessories, jointing of electrical cables up to Starter. All labourfor testing of submersible pumps set and supply of water to watermains, complete in all respect. OEM shall have submit NABL /CPRI/ ERDA accrediated lab type test certificate before execution. Allas per pre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR .5.0 HP, 1-Ø, (56 - 236)Mtr, (90 - 25) LPM Copper wound |
| 35 | Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in positionand applying a priming coat of approved steel primer all complete: |
| 36 | Providing and placing on terrace (at all floor levels) polyethylenewater storage tank ISI : 12701 marked with cover and suitablelocking arrangement and making necessary holes for inlet, outletand overflow pipes but without fittings and the base support for tank |
| 37 | Supply installation testing & Commissioning of high mast lightingsystem (as per PLG 07 of ILP UK techinical report no 7 of ILE UK/IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totallyhot dip galvanised by piecewise single dipped method high mast,lantern carriage suitable for up to 12 nos luminaries with welded arm(excluding luminares), mast head frame assembly with full cover,including 1 No. LED 15 Watts aviation obstruction lights, doubledrum type self sustaining winch, integral power tool accesible fromdoor with padlocking arrangement (winch motor with control circuit)hot dipped galvanised heavy duty pipe lightening finial, Stainlesssteel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. ropefor lantern carrage & 2 no. rope for winch assembly ) foundation bolt,torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mmtrailing cable, including outdoor type control panel for auto on / off,reverse / forward motor operation. The mast is constructed from mildsteel plates (as per IS 5986 Gr. 510 ) cut and folded to form apolygonal section, telescopic jointed and welding as per BS5135.etc. as required on Existing Foundation. ( See table P - 03 forspecs.) OEM Must have Type test certificate for wind tunnel test .All as per pre approved by Engineer in-charge. All as per preapproved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR12.5 Mtr HM (in 2 section) suitable for 6 No. Luminaries 2 no. ropefor lantern carrage & 2 no. rope for winch assembly |
| 38 | Providing & Fixing of IK08, IP 66 protected LED Street LightLuminaire on existing bracket/pole. Fixture made of powder coatedsingle piece pressure die cast aluminum material with heatdissipation fins on housing with UV stabilized PC (UV stablizationreport submitted for UV cover ) /Toughened Glass cover andsecondary lens on each LED & should be SMD type of 3 to 5 watteach . The System efficacy >=125 lm/ wt and potted driver & has aunique BIS R number with Input Voltage AC 120 to 270 V AC withHigh voltage Cutoff @>=300 V AC and Auto resetting Safety ,Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity10% to 90% RH Working Temp -5C to 45C . driver current <750mA.The luminaire shall be BIS certified and Trade mark certified. LifeExpectancy Equal or more than 50000 burning hrs with Minimum70% lumen maintened , CRI >70 and CCT 5700K +355K. Surgeprotection shall be min ≥ 4 KV internal and min 10 KV external insidedriver compartment. driver should be Phase to phase protection of440 V for 4 Hrs. Manufactures Word Mark/NameEngraved/Embossing on die cast housing to allowtraceability/authenticity. Fixture shall be AS PER IS 10322Complianced.OEM Must have its own in house NABL lab setup forall testing facilities for LED fixtures. (LM79/LM80) Certificate/report with liable warranty of product/accessories from OEM shall besubmitted. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR .LED Street Light fixture with Minimum lumen output 8700 lm |
| 39 | Supplying and drawing of XLPE insulated LT Aerial bunchedAluminium conductor cable confirming to IS 14255/1995 and IS 398(Pt-4)/ 1994 and as per Discom Specs. on existing cross armsthrough I hook with all necessary T&P required including binding andtwisting etc. complete in all respect as required. All as per preapproved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR .1 X 25 sq. mm. + 1X25 sq. mm. (insulated) |
| 40 | Supplying and drawing FR PVC insulated & unsheathed flexiblecopper conductor as per PWD specification for electrical Works withISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wireshould be made from 99.90 % purity copper, class 5 stranding inacc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for lesschances of oxidization, insulation PVC type A/C/D , flame retardantas per IS 10810-53, better amperage rating as per IS:3961 part 5, inexisting surface or recessed PVC/ MS conduit/casing cappingmaking connections with Copper Lugs of suitable size,Ferrules,testing etc. as required. OEM Must have its own in houseNABL lab setup for all testing facilities for wires. For additionaltechnical parameters of product / work refer Annexure 'A' attachedwith this BSR2 x 2.5 sq.mm |
| 41 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10kA breaking capacity (B/ C/D tripping characteristic as per type ofload and site requirement) 4 KV impulse withstand voltage, ISImarked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC, minimum phase termination capacity of35sq.mm. , conductor line load reversibility , IP 20 contact protectionand fitted in existing distribution board/sheets, minimum electricaloperation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80A & above rating including making connections, testing etc. asrequired. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test reports & All as per pre approved by Engineer incharge.For additional technical parameters of product / work referAnnexure 'A' attached with this BSRFour pole MCB (With B/C curve tripping Characteristics50/63 A rating |
| 42 | Providing & Fixing of AC operated heavy duty 230 /440 Volt powercontactor as per PWD specification for electrical Works, ISI markedIS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking,auxilary contacts, Din rail mounting type including makingconnections, testing etc. as required. All as per pre approved byEngineer in-charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR .4 pole Power contactors with following AC 1 Rating63 Amp |
| 43 | add contegency .45 % Please Enable Macros to View BoQ information |