Drinking Water Supply and Sanitation Government Departments Closing in 7 days TDR #55450020

Tender For Augmentation Of Water Supply Scheme For Village Razapur In Block Kapurthala Of District Kapurthala (Under Head Nabard Xxxi/State Share/4215)

Issued by Government Departments · Kapurthala, Punjab
Tender Value
88.79 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
7 days left
EMD
1.77 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kapurthala → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Augmentation Of Water Supply Scheme For Village Razapur In Block Kapurthala Of District Kapurthala (Under Head Nabard Xxxi/State Share/4215)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 29-May-2026 Date extended upto 08.06.2026 Date 08-Jun-2026
2 20-May-2026 Date extended upto 29.05.2026 Date 29-May-2026
3 20-May-2026 Date extended upto 29.05.2026 Date 29-May-2026
4 08-Jun-2026 Date extended upto 16.06.2026 Date 16-Jun-2026
5 29-May-2026 Date extended upto 08.06.2026 Date 08-Jun-2026
6 24-Jun-2026 Date extended upto 02.07.2026 Date 02-Jul-2026
7 16-Jun-2026 Date extended upto 24.06.2026 Date 24-Jun-2026
8 02-Jul-2026 Date extended upto 10.07.2026 Date 10-Jul-2026
9 16-Jun-2026 Date extended upto 24.06.2026 Date 24-Jun-2026
10 08-Jun-2026 Date extended upto 16.06.2026 Date 16-Jun-2026
11 10-Jul-2026 Date extended upto 21.07.2026 Date 21-Jul-2026
12 15-Jul-2026 Pre Bid Other 29-Jul-2026
13 21-Jul-2026 Date extended upto 29.07.2026 Date 29-Jul-2026
14 29-Jul-2026 Date extended upto 06.08.2026 Date 06-Aug-2026
15 15-Jul-2026 Pre Bid Other 06-Aug-2026

BOQ

Name of Work:- Augmentation of Water Supply Scheme for village Razapur in Block Kapurthala of District Kapurthala (Under head NABARD XXXI/State Share/4215)
Sl. No. Item Description
1Tubewell
2Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.(Note 1 : If tubewell bore is abounded due to non availability of required quality of potable water/strata then scheme will be dropped and no payment except cost of bore will be paid to bidder against allotment. Decision of Engineer incharge for dropping of scheme/cancellation of balance work will be acceptable to contractor without any additional compensation of any nature)
3Boring with 250mm id Housing Pipe
4Upto 150 m depth BGL
5Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
6200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness
7Supplying, Fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore
8200mm Steel Strainer (slot size 0.15mm) 6.30 mm thickness
9Supplying, Fixing & lowering of Stainless Steel Socket as per IS:8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode.to lower the strainer into tubewell bore complete in all respect.
10200mm internal diameter
11Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded withsuitable grade welding electrode complete in all respect.
12200mm internal diameter
13Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect
14Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore
15Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
16200mm internal diameter
17Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge
18Capacity of Air compressor 300 cfm at 250 PSI
19Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction ofEngineer-in-charge.
20Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
21Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, Uranium, lead, mercury, pesticide etc.)
22Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.
23200mm internal diameter 6.40 mm thickness
24Construction One No. 75KL (75,000 Itrs) capacity having height 22.00 mtr of up to FSL & 19.00 mtr sill level from Ground level complete with external RCC stair case with landing slabs at each staging RCC roof,ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing D.I. K-9 D/F expansion joints latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 9523 and C.I/D.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI double flanged pressure pipes DI K-9 horizontally as per IS 8329-2000 and latest Amendments duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel Providing & applying integral crystalline slurry hydrophilic in nature for water freezing management for vertical & horizontal service and swell able type water stop tape & painting of all complete shall be included in cost & P/F aluminum ladder inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil not less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. then the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Premium including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 including overflow scour haudi complete in all respects. Note 1) Providing and applying integral crystalline slurry of hydrophilic in nature for water proofing management etc. (For vertical and horizontal surface) 2) Providing and applying of swellable type water stop tape etc
25Rising Main
26Providing, Laying, fixing & jointing of P.V.C. Pipes as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete as per specifications.For more than 3 mtr street with mechanically Excavation including specials
27110mm o/d pipe of 10 kgf. / sqcm
28Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
29Class PN-1 as per ISI
30100mm i/d Sluice Valves flanged
31Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department
32Size 0.6 m. x 0.6 m.
33Distribution network
34Providing, Laying, fixing & jointing of P.V.C. Pipes Type-A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete as per specifications.For more than 3 mtr street width with Mechanically Excavation including specials
3563mm o/d pipe of 6 kgf. / sqcm
3675mm o/d pipe of 6 kgf. / sqcm
3790mm o/d pipe of 6 kgf. / sqcm
38110mm o/d pipe of 6 kgf. / sqcm
39160mm o/d pipe of 6 kgf. / sqcm
40Providing, Laying, fixing & jointing of P.V.C. Pipes Type-A as per ISI-4985-2021 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenhes to correct alignment and gradients, cutting, jointing and testing complete as per specifications.For Less than 3 mtr street width Manual Excavation including specials
4163mm o/d pipe of 6 kgf. / sqcm
4275mm o/d pipe of 6 kgf. / sqcm
4390mm o/d pipe of 6 kgf. / sqcm
44110mm o/d pipe of 6 kgf. / sqcm
45160mm o/d pipe of 6 kgf. / sqcm
46Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in theground complete.
4725mm i/d
4832mm i/d
4940mm i/d
50Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
51Class PN-1 as per ISI
5280mm i/d Sluice Valves flanged
53100mm i/d Sluice Valves flanged
54150mm i/d Sluice Valves flanged
55Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department
56Size 0.6 m. x 0.6 m.
57Size 0.9 m. x 0.9 m.
58Hand boring Horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method.Including excavation , stringing and jointing of pipe upto 160mm complete
59Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.
60For crossing pipe line Nakodar-Kala Sanghian-Kapurthala Major District Road
61160mm o/d pipe of 10 Kgf. / sqcm
62Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting and including restoration of roads to orginal Position
6363mm o/d pipe of 6 kgf. / sqcm
6475mm o/d pipe of 6 kgf. / sqcm
6590mm o/d pipe of 6 kgf. / sqcm
66Dismantling of interlock tile 80mm thick cement concrete interlocking paver block including Refixing of interlock tile 80mm thick cement concrete interlocking paver block of M-40 grade machine made rubber moulded smooth finish by strong vibratory process or with vibro hydraulic compaction machine and of approved size and design/ shape laid in ordinary grey color and pattern over including 40mm thick
6763mm o/d pipe of 6 kgf. / sqcm
68110mm o/d pipe of 6 kgf. / sqcm
69Connection with New PVC pipe to GI Pipe complete in all respect.
70Dismantling of cement concrete road and restoration in original condition
71Household water connection on PVC Pipe line
72Providing proposed water connection to household up to wall with providing, laying, jointing, testing GI pipe lines 15mm i/d B-Class, (Above GL), Prov. & fixing MDPE pipe 15mm i/d with speicals (Below GL), including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading and testing in trenches in ground and ISI marked 15mm i/d GM furrule as per IS:2692 and 3\\" i/d clamp with C.I. bibcock 15mm i/d as per IS:210 with stainless steel spindle of approved make complete in all respects
73Household water connection on GI Pipe line
74Providing proposed water connection to household up to wall with providing, laying, jointing, testing GI pipe lines 15mm i/d B-Class, (Above GL) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading and testing in trenches in ground and ISI marked 15mm i/d GM furrule as per IS:2692 and 3\\" i/d clamp with C.I. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make complete in all respects.
75Disinfection Unit
76Disinfection Unit Providing Installing, testing & commissioning one no. Electronically actuated, Diaphragm operated, Metering System, Chemical Dosing, Chlorinator, Suitable for delivering 0.5 to 6 Litres fo Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg. cm2 and suction lift not less than 1.5 m, as per DWSS standard specifications
77Solar Panel Energy System
78Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects.
79Pump Chamber
80Construction of Pump Chamber size 2.5 m x 2.5 m including cost of & electric wiring complete in all respect. Extra Provision for Sanitary Latrine in Pump Chamber for foundation and plinth of WC rooms including flooring, PVC pipes, Junction Box, 1 Nos. Leach pits, Super structure WC Room etc
81Pumping machinery including DI fitting
82Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 404 LPM against a head of 74 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc., including GI column Pipe of IS: 1239-2004 medium class suitable size 80 mm & length 47 mtr (in 3mtr lengths each with flanges, screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable 110 mtr length and 4.00mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects
83(Motor with Pump) 404LPM, 74mtr Head
84Panel Board
85Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:
86Overall size 4.0sq.mm (56/0.3mm), 3Core
87Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.
8880mm i/d
89D.I Fitting Inside Pump Chamber
90Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of D.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as D.I Bends, Tail Piece Tees etc. inside the pump chamber as per standard design complete in all respects
91Development of water works
92Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects
93Providing and fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI makred) wire 4mm dia fencing pole size at bottom 4\\" x 4\\", size top 3\\" x 4\\", length 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respect
94Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing
95Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects
96Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing complete in all respects.
97Construction of Cement Concrete Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing
98Providing & fixing MS Sign board as per standard size of DWSS
99Carriage of material
100Carriage of material (Sand, Bajri, Bricks)
101Enviornmental management charges
102Surface dressing of ground including removing rank vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m in all kinds of soil
103Supplying and planting permanent trees in prepared pits and watering
104Planting seasonal flower in beds
105Planting seedlings including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of seedlings at 20cm distance from plant to plant and row to row.
106Planting ground covers (ordinary) including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, planting of sapling at 25cm distance from plant to plant and row to row.
107Provision for one way stand post with khura complete in all respects. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55450020
AUTHORITY Government Departments
TENDER VALUE 88.79 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Water Supply And Sanitation Department
Work Description Tender for Augmentation Of Water Supply Scheme For Village Razapur In Block Kapurthala Of District Kapurthala (Under Head Nabard Xxxi/State Share/4215)
Basic Detail
Tender No 2026-27/NABARD31/RAZAPURrecall
Bidding Type Tender
Location
City Kapurthala
State Punjab
Key Dates
Publish Date 29 Jul 2026
Submission Date 06 Aug 2026
Open Date 06 Aug 2026
Finance
Tender Value 88.79 Lakhs
Tender Fee 1000
EMD 1.77 Lakhs
Exemption Not Available
Document List
AllDrawings.pdf
BOQ_341623.xls
DNITrazapur.pdf
e20f1638-9dd8-4022-bcff-49b77670d638.html
MAPofvillage.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 08, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 29, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 29, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 16, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 08, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 02, 2026
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 24, 2026
18:00 IST

Corrigendum-7 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 10, 2026
18:00 IST

Corrigendum-8 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 24, 2026
18:00 IST

Corrigendum-9 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 16, 2026
18:00 IST

Corrigendum-10 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 21, 2026
18:00 IST

Corrigendum-11 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 29, 2026
18:00 IST

Corrigendum-12 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 29, 2026
18:00 IST

Corrigendum-13 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 06, 2026
18:00 IST

Corrigendum-14 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Aug 06, 2026
18:00 IST

Corrigendum-15 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

AllDrawings.pdf

xls

BOQ_341623.xls

pdf

DNITrazapur.pdf

html

e20f1638-9dd8-4022-bcff-49b77670d638.html

pdf

MAPofvillage.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders