| 1 | SITC of Bore well Pump at VYLOPPILLI ANGANVADI |
| 2 | OD526745/2025-2026:Supply, installation, testing and commissioning of 1 HP Bore well submersible pump set having a discharge of not less than 2000 Ltr/Hours at a head of 50 mtrs (Head range 20 to 85 mtrs) with suitable impeller , strainer on suction side etc suitable for operation on Single phase, 230 V 50 Hz AC supply in the existing Bore well including submersible cable joint, connection to the existing delivery line, including providing and fixing 50 mtr long 10 mm dia SS pump lifting rope tying with nylon tags and fixing with suitable clamps made out of 60 x 10 mm MS flat iron( 2 set) etc. complete as required. ( Make Kirloskar KU4-0314 or equivalent models of Cromptionr, Texmo , Lubi, V gaurd, KSB,CRI) |
| 3 | OD526743/2025-2026:Providing and fixing 40 mm dia (O.D) UPVC medium duty column pipe suitable to withstand hydrostatic pressure of 15 Kg/ cm2, from the Bore well pump to the existing common delivery line with all accessories like, elbows, tees, male threaded adapters, flanges, bottom and top stainless steel pump adaptors etc as required. |
| 4 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 5 | OD528596/2025-2026:Supplying and fixing 32 mm bronze/Gun mettle Globe valve in the existing UPVC column pipe line with accessories as reqd. |
| 6 | OD528597/2025-2026:NON RETURN VALVE Gun mettle double flange as per IS/5312 PN 1.6 rating complete with Gun mettle body & wedge Stainless Steel spindle, Gland packing, Rubber gasket 32 mm dia Non Return Valv |
| 7 | 90.14.28.13:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,DPMCB for single phase 2 HP submersible motor pumps (DOL) |
| 8 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 9 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 10 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 11 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 12 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 13 | 5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 14 | OD529002/2025-2026:Extra for using Exel Grounding minerals ( 25 Kg ) compound to reduce the soil resistivity for above earth electrodes etc complete as required |
| 15 | 14.8:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. |
| 16 | OD531687/2025-2026:Preparation of drawing and necessary documents Submitting to the KSEB , Getting additional connected load, Including incidental charges, excluding statutory charges.( Below 5 KW ) |
| 17 | 5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 18 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 19 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 20 | OD533479/2025-2026:Supply and fixing of 1KVAR single phase Capacitor connected in position and giving direct connection to motor |
| 21 | OD533480/2025-2026:Supply and fixing 32A,HRC fuse with 32A fuse link with connections, in the existing meter board |
| 22 | OD533481/2025-2026:Supply and installation of dust and vermin proof , single phase Syntax Meter Board(GSMB 3525) to fix KSEB meters, fuse units CTs etc as required invludig fixing on wall,making good the damages Color painting etr... as required |
| 23 | OD533482/2025-2026:Supplying and fixing 32A , 2 way neutral links mounted on DMC/SmMC base with connections, in the existing meter board |
| 24 | OD533483/2025-2026:Providing and fixing 2 x 25 x 3mm GI strip test joint for earthing system |
| 25 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 26 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm |
| 27 | 1.14.4:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire Please Enable Macros to View BoQ information |