Tender For Non Plan-Urban Ugglomeration -2021-2022- Supplying And Installation Of Electro Mechanical Flow Meter In Out Let Line Of Kudapanakunnu Pump House .-Under W W Section , Peroorkada .-General Civil Work, Thiruvananthapuram-Kerala
TDR : 55444318
Tender Notice
BOQ
6 Days Left
Thiruvananthapuram
Kerala
Tender For Non Plan-Urban Ugglomeration -2021-2022- Supplying And INSTALLATION Of Electro Mechanical Flow Meter In Out Let Line Of Kudapanakunnu Pump House .-Under W W Section , Peroorkada .-General Civil Work
Name of Work:- Non Plan-Urban Ugglomeration -2021-2022- Supplying and instalation of electro mechanical flow meter in out let line of Kudapanakunnu Pump house .-under W W section , Peroorkada .-General Civil Work
Sl. No.
Item Description
1
SUPPLY OF ELECTROMAGNETIC FLOW METERS
2
OD186520/2024-2025: Supplying and installation of electro magnetic flow meter confirming to protection level of IP 68 for flow sensor and IP 67 for transmitter and having an accuracy level of 0.5% with LED/LCD display unit. The flow meter should have the housing to be made of SS 304/ Carbon Steel with anti corrosive protection and inside liner to be made up of Hard rubber/ neoprene all confirming to drinking water standards. The flow meter is to be installed in 350 mm dia DI pipe (work includes supply, installation, anchor blocks and all connected works ). The flow meter should be coupled with HART with data acquisition and transfer, with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions. Provision shall be there for integrating the flow meter reading with the existing SCADA system at PH Circle, Thiruvananthapuram.
3
Construction of Chamber for the Flow meter
4
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
5
4.1.2:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3graded stone aggregate 20 mm nominal size derived from natural sources)
6
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
7
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
8
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
9
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
10
100.98.1008:Engaging Coolie.
11
100.98.1009:Engaging Fitter ( grade 1).
12
100.98.1010:Engaging Assistant Fitter or 2nd class fitter. Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.