| 1 | SH: ICalibration of following relays of Crompton Greaves make HT Switching panel with three VCB's(01-I/C , 02-O/G), using secondary injection kit including adjustment of plug settings, transportation of test equipment to site for performinmg the tests and submitting test reports etc as required: 1. Over Current + Earth Fault relays- (Make: Genesis EASUN REYROLLE ,Model -MIT113) per VCB2. Auxiliary realy for transformer fault alarm (one per each transformer T/F-1 & 2) - Buchholz , Traformer Winding Temperature, Transforemer Oil temperature ( Make : Easun Reyrolle, Model: B33X3)3. Auxilliary relay for tranformer fault trip (one per each transformer T/F-1 & 2) - Buchholz , Traformer Winding Temperature, Transforemer Oil temperature ( Make : Easun Reyrolle, Model: B33X3) . |
| 2 | Inspection, servicing and testing of 800A C&S make Air circuit breakers including carrying out preventive maintenance asper OEM recommendations and submission of test reports etc. as required (Excluding cost of spares) |
| 3 | Carrying out the BDV test & Acidity test of the transformer oil,through a NABL accredited lab/Govt. approved lab or through portable test facility at site and submission of the test reports to AAI. The cost shall include all expenses towrads collection of samples as per the requirements of the testing lab/ facility, transporting the samples to the test lab ( as applicable), to and fro transportation and engaging skilled person to conduct the tets at site, in case of using portable test failcity for site testing and any other incidental charges associated with the performing of these test etc. in complete etc. as required. |
| 4 | Filtration of insulation oil of 400 KVA, 11 / 0.415 KV transformers by stream line and hot oil circulation for three cycles or more till achieving required value including certification, transportation ( to & fro) of machineries etc.complete as required (400 KVA transformer Oil tank capacity - 415 ltr). |
| 5 | Calibration of the following measuring instruments possessed by AAI from any NABL accredited lab/Govt. approved lab and submission of the calibration certificates to AAI |
| 6 | Fluke 302+ 400A AC Clamp Meter |
| 7 | Fluke 1621 Earth Ground Tester kit |
| 8 | Mitutoyo 500-164-30 Digital Caliper |
| 9 | Clinometer - (AMA make) |
| 10 | Servicing and calibration of Phoenix / Essae make, Class III type 100 kg to 150 kg weighing machine/scale including liaisoning with the concerned state/central govt.department, to & fro transportation, laisoning charges etc. complete as required. |
| 11 | Locating the cable fault like earth fault, open circuit fault etc, for cables upto 11kV, by means of portable fault locator, including necessary excavation, identifying the fault etc., complete as required . ( 1 no. of fault identified by the agency shall constitute 1 job) |
| 12 | Hiring of mechanical excavator for excavation works related to day to day maintenance/cable fault tracking etc.(@ 8hrs per day) |
| 13 | Repairing of earth pits by dismolishing existing masonry enclosure and providing RCC enclosure of 1:2:4 grade (1 cement : 2 coarse sand : 4 graded stone) reinforced with steel rods 8mm dia in a pattern approved by AAI, providing hinged MS cover of minimum 8 mm thickness good engineering practice including, painting the earth pit portion above ground and cover plate, numbering the same, providing and fixing suitable funnel, removing of debris etc. complete as per the direction of EIC. |
| 14 | Lifting of defective submersible pumps from openwell / sump and dismantling the same and installing the serviceable motor pump set, arranging T&P and necessary consumables like Teflon tape,Stainer, minor hardware items like bolts & nuts etc., including lifting and lowering into sump / openwell etc complete as required (Serviceable Motor will be provided by AAI). |
| 15 | Lifting and lowering of submersible bore well pump along with the installed pipe from bore well ( up to 850 feet max) including dismantling the defective submersible motor pump set and installing the serviceable motor pump set with the existing pipe, arranging T&P and necessary consumables etc complete as required |
| 16 | Replacement of 6 mm dia. SS wire in existing High mast (up to 30 mtrs) in existing M/s Bajaj Make High masts, including proper winding of cable on double drum, greasing, fastening etc., and recommissioning of the mechanical system, for ensuring satisfactory up and down operation of the Luminaire Carriage and its balancing etc complete as required. |
| 17 | Replacement of Flexible Copper trailing Cable in existing High mast (up to 30 mtrs) in existing M/s Bajaj Make High masts, including proper fastening of cable to the SS wire as per OEM standards and recommissioning of the system including replacement of 10 point Connectors (Plug & socket) at terminal ends for ensuring satisfactory functioning and operation of the Luminaire system etc., complete as required. |
| 18 | Rewinding, servicing, repairing of ceiling fan upto 1400mm sweep including replacement of wornout / defective parts like bearings, capacitors etc., i/c transportation from site to workshop & back to site. (Dismantled Material belongs to contractor). |
| 19 | Rewinding, servicing, repairing of wall mounted fans/exhaust fans/pedestal fans upto 450mm sweep including replacement of wornout / defective parts like bearings, capacitors etc., i/c transportation from site to workshop & back to site. (Dismantled Material belongs to contractor). |
| 20 | Re-winding and repair of following rating submersible/monoblock pump motors including dismantling, cutting of burnt out wire, rewinding with the same gage insulated copper wire including replacement of all the internal worn out / defective parts, re-assembling, testing of motor, transportation of the submersible pump motor set to the site etc as and on when required. |
| 21 | Below & upto 3 HP capacity |
| 22 | Above 5 HP - upto 10 HP |
| 23 | Servicing of following capacity Monoblock/sub-mersible pumps i/c replacement of all worn out GM bushes, thrust bearings, impellers, studs sets and necessary spares and lathe work, transportation charges complete in all respect etc., as on when required. |
| 24 | Below & upto 3 HP capacity |
| 25 | Above 5 HP - upto 10 HP |
| 26 | Supply and replacement of front glasses ( 2 for each cabinate) for fire hose cabinate along with necessary gaskets etc.,as required. ( Aproximate size of the front glass is 200mm X 300mm). |
| 27 | Annual maintenance contract of Uniline make 6 KVA UPS complete with all electrical, electronic, mechanical, equipment, safety controls and instrumentations with all associated systems including carrying out Quarterly maintenance as per OEM's & AAI recommendations including attending unlimited breakdown calls etc., as required. 1 Job= 1 UPS for 1 year. Payment shall be on quarterly basis |
| 28 | Supply and Replacement of facia/front sheet for operational area(GLF) signboard with the nomenclature as provided by AAI as per the dimension of DGCA-CAR suitable for existing signbaords |
| 29 | Providing and fixing of signboard sticker on polycarbonate sheet of operational area signboards as per the existing sign/nomenclature including removal of existing sign etc., including necessary transporation as required. |
| 30 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders along with extended rotary handle, in existing cubicle panel board including removal of existing MCCB and fixing of new MCCB with necesaary bus bar modification as required, making connections, Ics=100% Icu etc. as required.400 A, 50 KA,FP MCCB |
| 31 | SH:II (DSR Items)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR-LSH PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FR-LSH PVC insulated copper conductor single core cable etc. as required.Group-C |
| 32 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 33 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 34 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 35 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 36 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 37 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 38 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 39 | 1 x 1.5 sq. mm |
| 40 | 3 x 1.5 sq. mm |
| 41 | 2 x4sqmm |
| 42 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm |
| 43 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 44 | 1 or 2 Module |
| 45 | 3 Module |
| 46 | 4 Module |
| 47 | 6 Module |
| 48 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 49 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 50 | Upto 450 mm sweep |
| 51 | Upto 600 mm sweep |
| 52 | Supplying and fixing of following ways surface/ recess mounting, Horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required.4 way (8 + 12), Double door |
| 53 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"c\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 54 | Single pole |
| 55 | Double Pole |
| 56 | Four pole |
| 57 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A |
| 58 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess,with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 59 | Supplying and fixing 20 A, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 60 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required |
| 61 | Laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ Termination with GI thimble etc. as required.( GI wire shall be provided by AAI) |
| 62 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 63 | Fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.( GI wire shall be provided by AAI) |
| 64 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 65 | Upto 35 sq. mm |
| 66 | Above 95 sq. mm and upto 185 sq. mm |
| 67 | Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing DWC / HDPE / RCC / HUME / METAL pipe as required. |
| 68 | Upto 35 sq. mm |
| 69 | Above 95 sq. mm and upto 185 sq. mm |
| 70 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required.3.5C X 185 sq. mm (57mm) |
| 71 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 72 | 4C X 16 sq. mm |
| 73 | 3.5C X 35 sq. mm |
| 74 | 3.5C X 185 sq. mm |
| 75 | 3.5C X 240 sq. mm |
| 76 | 4C X 25 sq. mm |
| 77 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia |
| 78 | Making hole for installation of exhaust fan of size upto 450mm sweep by demolishing brick work manually/ by mechanical means including disposal of malba within 50 metres lead and making good the wall by plastering etc. as required |
| 79 | Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :185 sq. mm |
| 80 | Spray painting with two or more coat of synthetic enamel paint of approved brand, manufacturer and colour to give an even shade for distribution boards,Fire hydrant Pipes, Internal & External Electrical panels/ Junction boxes/feeder pillars, etc. provided in the Terminal Buildings, Technical Block and other Ancillary Buildings including cleaning the surface, applying two or more coats of primer wherever necessary,removing, shifting of installations from existing site to a suitable site for painting where ever required.Scope also includes re-lettering / new lettering of various distribution boards/ panels wherever required |
| 81 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) including form work etc as required. |
| 82 | Engaging of unskilled labour for carrying out casual/unspecified works like clearing of site, shifting of inventory, and other miscellaneous Electrical works as per instructions from Engineering in charge ( 1 man day = 8 hours of work). |
| 83 | Supplying and making straight through joint for 1C x 6 sq.mm Airport Lighting Cable with heat shrinkable kit and other jointing materials for following size of 5 KV grade AFL cables as required. |
| 84 | Supplying and making straight through joint for 1C x 16 sq.mm Airport Lighting Cable with heat shrinkable kit and other jointing materials for following size of 5 KV grade AFL cables as required. |
| 85 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means , including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. In all types of soils |
| 86 | Supply of automatic AC changeover timer for cyclic operation of two air conditioners of any make up to 2 TR capacity each, with minimum time setting of 4 hours, operating on single phase 230V, 50 Hz supply, having two independent output channels for alternate operation, complete with mounting arrangement and all necessary accessories as required Please Enable Macros to View BoQ information |