| 1 | SUPPLY OF MATERIAL |
| 2 | 33 KV Top channel 125x65x6mm- 3200mm |
| 3 | 33 KV Bracing angle 65x65x6mm- 4300mm with clamp |
| 4 | 33 KV Stay rod 20x1800 |
| 5 | Dropper channel 100x65x6mm- 2200mm |
| 6 | Earthing rod 20x2500 mm |
| 7 | Stay Wire7/8 SWG |
| 8 | GI wire 5mm |
| 9 | Top channel clamp for all size pole support |
| 10 | Dropper channel clamp for all size pole support |
| 11 | Bracing angle clamp for all size pole support (Top & Bottom) |
| 12 | 33 KV 'E' bracket |
| 13 | GI pipe 6\\" dia |
| 14 | HDPE Pipe 160mm dia PN6, PE100 |
| 15 | Stay clamp |
| 16 | Earth wire clamp |
| 17 | PG clamp for DOG conductor |
| 18 | Danger Board 33 KV with clamp |
| 19 | Number plate |
| 20 | GI Barbed wire |
| 21 | Nut & bolts with washer all size |
| 22 | Cable holding clamp |
| 23 | Stone pad 300x300x75mm |
| 24 | Red oxide paint |
| 25 | Allu. lug 300mm |
| 26 | Allu. Paint |
| 27 | 33 kV underground line caution tape 14'' width |
| 28 | Stay insulator for 20x1800 mm stay rod of 33 kV |
| 29 | Cable route marker height*width =40\\"x10\\" and thikness=3\\" Engraving of \\"NOMENCLATURE -33kV NDERGROUND CABLE, DEPTH - ……METER\\" |
| 30 | ERECTION OF WORKS |
| 31 | ST Pole 11 mtr long |
| 32 | ST Pole 13 mtr long |
| 33 | ACSR DOG conductor |
| 34 | 33 KV Disc insulator B&S type polymeric 70KN |
| 35 | Disc fitting DOG 70 KN |
| 36 | 33 KV Pin insulator Polymeric type |
| 37 | 33 KV Top channel 125x65x6mm- 3200mm |
| 38 | 33 KV Bracing angle 65x65x6mm- 4300mm with clamp |
| 39 | 33 KV Stay rod 20x1800 |
| 40 | Dropper channel 100x65x6mm- 2200mm |
| 41 | Earthing rod 20x2500 mm |
| 42 | Stay Wire7/8 SWG |
| 43 | GI wire 5mm |
| 44 | Top channel clamp for all size pole support |
| 45 | Dropper channel clamp for all size pole support |
| 46 | Bracing angle clamp for all size pole support (Top & Bottom) |
| 47 | 33 KV 'E' bracket |
| 48 | GI pipe 6\\" dia |
| 49 | Stay clamp |
| 50 | Earth wire clamp |
| 51 | PG clamp for DOG conductor |
| 52 | Danger Board 33 KV with clamp |
| 53 | Number plate |
| 54 | GI Barbed wire |
| 55 | Nut & bolts with washer all size |
| 56 | Cable holding clamp |
| 57 | Stone pad 300x300x75mm |
| 58 | Red oxide paint |
| 59 | Allu. lug 300mm |
| 60 | Allu. Paint |
| 61 | 33 kV underground line caution tape 14'' width |
| 62 | Stay insulator for 20x1800 mm stay rod of 33 kV |
| 63 | Cable route marker height*width =40\\"x10\\" and thikness=3\\" Engraving of \\"NOMENCLATURE -33kV UNDERGROUND CABLE, DEPTH - ……METER\\" |
| 64 | Grouting & concreting of all pole support along with muffing as per RESPO norms |
| 65 | Concreting of stay rod as per RESPO norms |
| 66 | Digging & Making of cable trench by providing red sand, bricks, stone slab (bricks, sands & stone slab will be provided by contractor) |
| 67 | Laying and dressing of 33 kV, 3x300 sqmm XLPE cable including loop with double circuit configuration into dug cable trench and the cable & cable loop shall be properly protected by placing, red sand, brick and 75m thick stone slabs separately for each cable as per RESPO/Approved cable SOP norms. |
| 68 | Laying & Dressing of 160 mm HDPE pipe after making excavation of digging bore pit, with double circuit configuration below highway road by HDD method |
| 69 | Laying & dressing of 33 kV, 3x300 sqmm XLPE cable with double circuit configuration into laid 160 mm HDPE pipe below highway road by HDD method including cable loop and the cable loop shall be properly protected by placing red sand, brick and 75mm thick stone slabs, separately for each cable loop as per RESPO/Approved cable SOP NORMS (red sand, bricks, stone slab will be provided by Contractor) |
| 70 | Making & Jointing of 33 KV 3x300 sqmm Cable Jointing Kit outdoor |
| 71 | Making & Jointing of 33 KV 3x300 sqmm Cable Jointing kit Straight Through |
| 72 | Hosting of 33 kV cable on erected pole support & clamping it |
| 73 | Cartage of 33Kv 3x300Sqmm XLPE cable |
| 74 | Cartage charge of all material Please Enable Macros to View BoQ information |