| 1 | The rate of supply of item is inclusive of Freight and insurance at site including loading & unloading. |
| 2 | PCC Poles 9 mtr long 200 Kg |
| 3 | ACSR Rabbit Conductor |
| 4 | 11 KV Disc Insulator 45 KN T&C Type |
| 5 | 11 KV Disc Insulator H/W Set for 45 KN T&C Type |
| 6 | 11 KV Pin Insulator |
| 7 | 11 KV Galvanised MS Forged Pin |
| 8 | G.S. Stay Sets 16X1800 MM |
| 9 | G.S. Stay Wire 7/10 SWG |
| 10 | 11 KV Stay Insulator |
| 11 | Stay Set Clamps suitable for 9mtr. Long PCC Poles |
| 12 | 11 KV 'V' Cross Arm (Angle) with Top Hampers and Clamps |
| 13 | 33 KV S/C Lattice Structure (36' ungalvanised with 1 No. 33 KV cross arm (Channel)) |
| 14 | Excavation of pit in Hard rock (Where blasting/drilling is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. |
| 15 | (A) Height of poles/R.S.Joist/M.S. Rail /Size of pit |
| 16 | 9 Mtr/ 1.2mx0.6mx1.50 m deep |
| 17 | (B) Lattice Tower /Size of pit |
| 18 | 11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep |
| 19 | (C) Stay set/Depth of pit |
| 20 | 6'x 5/8\\" -0.75x0.5x1.35 m |
| 21 | Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The cost muffing and grouting will be paid extra. |
| 22 | Lattice Structure |
| 23 | Erection of PCC poles in excavated pit with fixing of brackets, cross arms & top hampers as required in alignment after checking the same with plumb line. The support is to be back filled with soil with proper ramming. |
| 24 | (B) IN RURAL AREA |
| 25 | PCC Poles 9 Mtr. Long (200 Kg) |
| 26 | Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line. Including fixing of top bracing of M.S.Channels with pilot plates and clamps. The support is to be back filled with soil with proper ramming. |
| 27 | PCC Poles 9 Mtr. Long(200 Kg.) |
| 28 | Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming. The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension. Size of stay set/stay wire |
| 29 | 6\\"x5/8\\" with 7/10 SWG stay wire |
| 30 | Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement, river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21 days in steel plates shuttering /farmer base. |
| 31 | Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 1 Nos. disc & 1 set of H/W) on terminal point including fixing of hardware and strips. |
| 32 | Fixing of 11 KV pin insulator with pins. |
| 33 | Laying, jointing, stringing, tensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire / P.G.clamps. Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. |
| 34 | (B) IN RURAL AREA |
| 35 | ACSR RABBIT |
| 36 | Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper. (including cost of red oxide) |
| 37 | On new surface |
| 38 | Painting with aluminium paint of approved brand and manufacturer to give an even surface. (including cost aluminium paint) |
| 39 | On new works with two coats. |
| 40 | Dismantling work |
| 41 | Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming. The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension. Size of stay set/stay wire |
| 42 | 6\\"x5/8\\" with 7/10 SWG stay wire |
| 43 | Fixing of cross arms with clamp on erected support as per design. |
| 44 | 11 KV cross arms |
| 45 | Fixing of top hampers with clamp on erected support as per design. |
| 46 | 11 KV Top Hampers |
| 47 | Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 1 Nos. disc & 1 set of H/W) on terminal point including fixing of hardware and strips. |
| 48 | Fixing of 11 KV pin insulator with pins. |
| 49 | Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV & LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. |
| 50 | 10 and 16 KVA |
| 51 | 25 and 40 KVA |
| 52 | Laying, jointing, stringing, tensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire / P.G.clamps. Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging. |
| 53 | (B) IN RURAL AREA |
| 54 | ACSR WEASEL Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: SUPERINTENDING ENGINEER (TW), JVVNL, JAIPUR Name of Work: Execution of deposit works, including the Supply, Erection, Installation, Testing, and Commissioning of materials/equipment for the construction of 33/11 KV sub-stations, 33 KV & 11 KV overhead Line, laying of 33 KV and 11 KV underground XLPE Cable, construction of 33 KV Bay, 11 KV Bay and shifting of 33 KV & 11 KV line, Metering under Jhalawar circle on turnkey basis against TW/TN-624. Contract No: JPD/SE(TW)/TW/TN-624 Name of the Bidder/ Bidding Firm / Company : ABSTRACT OF PRICE SCHEDULE FOR SUPPLY & ERECTION OF MATERIAL & EQUIPMENT(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) |
| 55 | Description |
| 56 | Quoted rate in BOQ1- SUPPLY OF MATERIAL AND EQUIPMENT |
| 57 | Quoted rate in BOQ2- ERECTION OF MATERIAL AND EQUIPMENT Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |