| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:GE (AF) HASIMARA Name of Work : PROVN OF ANTI MONKEY MENCE MEASURES IN RS, OMQ AND KV AREA AT AFS HASIMARA Contract No: GE/HAS/ /2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Disconnecting existing PVC tanks (exc. 500 ltr but n.exc 1000 ltr) setting aside (or lowering if required) for necessary repair work (roof treatment etc.), cleaning, and hoisting (if required), reconnecting existing GI pipe with the tank and re-fixing in position, complete all as specified and directed. |
| 3 | Disconnecting existing PVC tanks (exc. 250 ltr but n.exc 500 ltr) setting aside (or lowering if required) for necessary repair work (roof treatment etc.), cleaning, and hoisting (if required), reconnecting existing GI pipe with the tank and re-fixing in position, complete all as specified and directed. |
| 4 | M & L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in benching coping/kerbs and roof padding as base for tank etc., including necessary form work, complete all as specified and directed. |
| 5 | Demolition of reinforced cement concrete (RCC water tank) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.(Note : reinforcement cut as required to facilitate demolition) |
| 6 | M&L for mild steel framed work such as grill, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barrel iron doors, ladders framed balusters, walks railings, frame work of water tanks and similar work conforming to E-165 (Fe-290) including two coats of synthetic enamel paint over one coat of red oxide, complete all as specified and directed. |
| 7 | M&L for hard drawn steel wire fabric n. exc 4.0 Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in diasupplied and fixed in reinforcemnt, complete all as specified and directed. |
| 8 | Taking out old damaged tarfelt or membran of any description including screed bed or bedding layer and removing of debris to a distance exc. 50m and n. exc. 100m and cleaning roof surfaces to remove all loose dust etc., roughening surfaces of old concrete roof by picking, sweeping clean and washing down with water using wire brush, brooming down and applying the following treatment all as directed in order of precedence as stated:(a) Brushing neat cement slury with 3.0 kg of cement per Sqm.(b) 15mm thick screed bed or bedding layer in CM (1:4) mixed with water proofing compound as per manufacturer instruction on existing roof surface true to level.(c) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm. (d) Supply and laying 3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.50 Kgs per Sqm reinforced with non-woven polyester fabric weighing not less than 160gms per Sqm having softening point not less than 15°C, having tensile strength of 650 N/Sqcm and 350 N/Sqcm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180 N by torch application. Polymeric membrane shall be taken to a height of 30cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (e) Applying one coat of aluminium paint @ 0.15 Kg/Sgm over APP membrane surface. Note:- (i) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions.(ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction.(iii) APP based polymeric membrane shall be of any one of the approved makes as specified here-in-after and shall conform to specifications given in IS 16540-2017/1S 16532 2017.(iv) Contractor shall produce necessary test certificate of the manufacturer to the Engr-in-Charge before incorporation in the work. (v) Necessary independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work.(vi) WPC shall be measured and paid separately as 'supply only'.(vii) The work shall be executed through authorised applicators of original manufacturer only. |
| 9 | Taking down 20mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 10 | S&F steel water tubing and connection, medium grade, 20mm bore with all fittings fixed to wall or in ceilings, complete all as specified and directed. |
| 11 | Re-fixing old steel tubing and connection 20mm bore in new or old position with new fittings, fixed to wall or in ceilings, complete all as specified and directed.(Note : Serviceable steel tube obtained from taking down shall be re-used) |
| 12 | S&F rotational moulded polyethylene (HDPE) water storage tanks, (made of 100% virgin and food grade plastic), triple layered, (cylindrical vertical with closed top) ISI marked, confirming to IS 12701-1996, hoisted and fixed in position all as specified in SSR Part I (1000 ltr capacity) including 20mm Nipple suitable for HDPE water tank and 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed to 20mm bore pipe, inculding taking down old unserviceable water tank of any capacity, complete all as specified and directed. |
| 13 | S&F rotational moulded polyethylene (HDPE) water storage tanks, (made of 100% virgin and food grade plastic), triple layered, (cylindrical vertical with closed top) ISI marked, confirming to IS 12701-1996, hoisted and fixed in position all as specified in SSR Part I (500 ltr capacity) including 20mm Nipple suitable for HDPE water tank and 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed to 20mm bore pipe, inculding taking down old unserviceable water tank of any capacity, complete all as specified and directed. |
| 14 | Dismantling of floor, hearth or wall tiles including cement mortar bedding (but not backing) and remvoing serviceable tiles to store and rubbish off the premishes, complete all asspecified and directed. |
| 15 | M&L chequered cement concrete tiles 25cm x 25cm x 22mm thick, with grey pigment cement and pigment, set, jointed and pointed in neat cement slurry in floors ver & including 15mm thick screed bed in CM (1:4), mixed with WPC as per manufacturer's instructions joint of tiles shall be filled with slurry mixed with WPC, complete all as specified and directed.(Note : WPC shall be measured and paid separately as 'supply only'). |
| 16 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed. |
| 17 | S&F 100mm size mild steel butt hinges, medium weight, cold rolled, complete all as specified and directed. |
| 18 | Note: An amount of Rs.32,725.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |