Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Schedule 'A' |
| 2 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and directed by Engineer-in-charge. |
| 3 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons Laid, bedded and pointed in any mortar etc., complete all as specified and directed by Engineer-in-charge. |
| 4 | Taking down chowkhat with shutters (without taking of shutters from the frames of any description exceeding 1.5 sqm but not exceeding 4.0 sqm in each panel, complete all as specified and directed by Engineer-in-charge. |
| 5 | Demolition of Concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engineer-in-charge. |
| 6 | Dismantling/ Demolition of brick work or stone masonry or RCC Pre cast Jali & Jafari built in cement mortar including all quoins, arches, pillars, etc., complete all as specified and directed by Engineer-in-charge. |
| 7 | Taking down cement plaster on stone wall including racking out joints, hacking for key scrubbing with water etc., complete all as specified and directed by Engineer-in-charge. |
| 8 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engineer-in-charge. |
| 9 | Demolition and breaking up drain pipes (SGSW, AC or RCC) of internal dia 150mm, set in cement mortar, complete all as specified and directed by Engineer-in-charge. |
| 10 | Supply & Fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing, complete all as specified and directed by Engineer-in-charge. |
| 11 | Supply & Fixing Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and directed by Engineer-in-charge. |
| 12 | Supply & Fixing 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed by Engineer-in-charge. |
| 13 | Supply & Fixing 150mm long Extruded Aluminium alloy handles, fabricated type, and anodised, complete all as specified and directed by Engineer-in-charge. |
| 14 | Supply & Fixing 150mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engineer-in-charge. |
| 15 | Supply & Fixing 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as specified and directed by Engineer-in-charge. |
| 16 | Material & Labour for 10mm thick vitrified tile of area exceeding not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15mm thick in Cement Mortar 1:6, complete all as specified and directed by Engineer-in-charge. |
| 17 | Material & Labour for 10mm thick vitrified tile of area exceeding not exceeding 0.36 sqm in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match over cement mortar 15mm thick in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-charge. |
| 18 | Material & Labour for PCC (1:2:4) type B0 using 12.5mm graded aggregate as in floor of average 25mm thick, complete all as specified and directed by Engineer-in-charge. |
| 19 | Material & Labour for Non-skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile not exceeding 0.11 sqm in floors, over and including 15mm thick screed in Cement Mortar (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match, complete all as specified and directed by Engineer-in-charge. |
| 20 | Material & Labour for Glazed ceramic tiles in vertical surface 350x 250x 7mm / 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including 15mm cement plaster in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-charge. |
| 21 | Material & Labour for granite (of any type) 20mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including, grinding, polishing, moulding the edges and polishing and including over screed bed 20mm thick in cement mortar 1:6, complete all as specified and directed by Engineer-in-charge. |
| 22 | Material & Labour for precast RCC 1:2:4 Type-B1 (using 20mm graded crushed stone aggregate) as in manhole and drain cover slab and similar article with plain faces, set in cement Mortar 1:4, complete all as specified and directed by Engineer-in-charge. |
| 23 | Material & Labour for Porbandar stone masonry, well bonded, bedded and solidly hearted built in Cement Mortar 1:6, complete all as specified and directed by Engineer-in-charge. |
| 24 | Material & Labour for rendering 5mm thick on ceiling concrete surfaces in cement mortar 1:3 and even and smooth without using extra cement, complete all as specified and directed by Engineer-in-charge. |
| 25 | Material & Labour for 15mm thick rendering in Cement Mortar 1:6 to stone surfaces trowelled to even & smooth w/o using extra cement, complete all as specified and directed by Engineer-in-charge. |
| 26 | Material & Labour for preparing surfaces plastered or un-plastered new surface of walls applying two coats of oil bound distemper over a coat of primer over layer of 3mm smooth Putty finish as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-charge. Note: - After painting, cleaning of all floors, glass & Furniture by own arrangement. |
| 27 | Material & Labour for complete removal of existing treatment by washing down and smoothing old surface of walls including scrapping and applying two coats of oil bound distemper over a coat of primer over layer of smooth Putty finish two coats as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-charge. Note: - After painting, cleaning of all floors, glass & Furniture by own arrangement. |
| 28 | Material & Labour for preparing surfaces plastered or un-plastered new surface of ceiling applying two coats of oil bound distemper over a coat of primer on smooth putty finish two coats as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-charge. Note: - After painting, cleaning of all floors, glass & Furniture by own arrangement. |
| 29 | Material & Labour for preparing surfaces plastered or un-plastered old surface of ceiling applying two coats of oil bound distemper over a coat of primer two coats as per manufacture instruction with smooth roller finish, complete all as specified and directed by Engineer-in-charge.Note:- After painting, cleaning of all floors, glass & Furniture by own arrangement. |
| 30 | Supply & Fixing PVC Floor trap 75mm bore with grating including jointing using solvent cement to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed by Engineer-in-charge. |
| 31 | Supply & Fixing PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed by Engineer-in-charge. |
| 32 | Supply & Fixing 110mm dia PVC band any radius, complete all as specified and directed by Engineer-in-charge. |
| 33 | Supply & Fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engineer-in-charge. |
| 34 | Supply & Fixing PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to walls, complete all as specified and directed by Engineer-in-charge. |
| 35 | Supply & Fixing PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in trenches, complete all as specified and directed by Engineer-in-charge. |
| 36 | Supply & Fixing PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in trenches, complete all as specified and directed by Engineer-in-charge. |
| 37 | Supply & Fixing PVC (SWR) bends 110mm bore with/without access door any radius, complete all as specified and directed by Engineer-in-charge. |
| 38 | Supply & Fixing PVC (SWR) bends 75mm bore with/without access door any radius, complete all as specified and directed by Engineer-in-charge. |
| 39 | Supply & Fixing PVC (SWR) single junction 'T' 75mm bore with access door any radius, complete all as specified and directed by Engineer-in-charge. |
| 40 | Supply & Fixing PVC (SWR) single junction 'T' 110mm bore with access door any radius, complete all as specified and directed by Engineer-in-charge. |
| 41 | Supply & Fixing PVC (SWR) vent cowl 110mm dia., complete all as specified and directed by Engineer-in-charge. |
| 42 | Supplying and laying of 16mm dia CPVC pipes SDR 11 & fittings on walls/ceilings or laying in floors, complete all as specified and directed by Engineer-in-charge. |
| 43 | Supplying and laying of 20mm dia CPVC pipes SDR 11 & fittings on walls/ceilings or laying in floors, complete all as specified and directed by Engineer-in-charge. |
| 44 | Supply & Fixing Female Brass threaded Adaptor for special fitting of 16mm bore CPVC pipe, complete all as specified and directed by Engineer-in-charge. |
| 45 | Supply & Fixing 15mm bib tap (fancy type), cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed by Engineer-in-charge. |
| 46 | Supply & Fixing brass CP shower rose 125mm size fancy type with swivel joint any size including fixing to steel pipe/union for 15mm dia., complete all as specified and directed by Engineer-in-charge. |
| 47 | Supply & Fixing PVC connection of 15mm dia length 600mm, complete all as specified and directed by Engineer-in-charge. |
| 48 | Supply & Fixing Vitreous China single piece European water closet pan, any colour with P or S trap with and including plastic water closet seat cover, connection to trap, flushing pipe & anti -syphonage pipe etc., including necessary materials for fittings & making good to floor, complete all as specified and directed by Engineer-in-charge. |
| 49 | Supply & Fixing Vitreous China ware wash hand basin white, size 400x400x140mm size with cutting for and pinning ends of brackets or erecting stand including, chromium plated 15mm mixer, CP waste coupling, 32mm dia PVC pipe, complete all as specified and directed by Engineer-in-charge. |
| 50 | Supply & Fixing in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs bedding urinal against wall in Cement Mortar 1:2 securing urinal to plug including 60mm long brass screws, pointing around urinal back in Cement Mortar, fixing automatic flushing cistern with bracket, flush pipe, grating and union for discharge pipe, complete all as specified and directed by Engineer-in-charge. |
| 51 | Supply & Fixing wall mixer 3 in 1 with provision for overhead shower and hand shower with 115mm long band pipe on upper side, connecting legs & wall flanges, complete all as specified and directed by Engineer-in-charge. |
| 52 | Supply & Fixing in repair Bevelled edge mirror, 600mm x 450mm of selected quality glass, mounted on 6mm thick or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed, complete all as specified and directed by Engineer-in-charge. |
| 53 | Supply & Fixing in repair stainless steel 6 Pin cloth hanger wall mounted having length 30 cm, fancy type, complete all as specified and directed by Engineer-in-charge. |
| 54 | Supply & Fixing Towel rack of size 600mm long Stainless steel of grade 304 of MAKE Cera Cat part No F5015101CH or equivalent make mentioned in Appendix 'B', complete all as specified and directed by Engineer-in-charge. |
| 55 | Supply & Fixing Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and directed by Engineer-in-charge. |
| 56 | Supply & Fixing in repair 15mm bore stop valves/ Angle valve, cast copper alloy fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-charge. |
| 57 | Supply & Fixing in repair 15mm dia CP two way angle valve fixed in pipe, complete all as specified and directed by Engineer-in-charge. |
| 58 | Supply & Fixing in repair 20mm dia Stop valves / gate valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-charge. |
| 59 | Supply & Fixing in repair Stop valves/Angle valves of size 15mm dia fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-charge. |
| 60 | Excavating in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre depth for foundation, etc., or not exceeding 10 Sqm on plan and not exceeding 1.5 Metre in depth for shafts, cesspits, manholes, pier holes, etc., and getting out in loose/soft soil, complete all as specified and directed by Engineer-in-charge. |
| 61 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each, complete all as specified and directed by Engineer-in-charge. |
| 62 | Removing excavated soil not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-charge. |
| 63 | Material & Labour for Concrete bed to drain pipes 150mm bore including packing under and hunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate, complete all as specified and directed by Engineer-in-charge. |
| 64 | Material & Labour for reinforced concrete pipes, class NP-2, laid and jointed complete with collars, laid in trenches and jointed, complete all as specified and directed by Engineer-in-charge. |
| 65 | Material & Labour for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors, complete all as specified and directed by Engineer-in-charge. |
| 66 | Material & Labour for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors, complete all as specified and directed by Engineer-in-charge. |
| 67 | Material & Labour for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, bed blocks, copings, bed plates, bond stones, etc., including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work, complete all as specified and directed by Engineer-in-charge. |
| 68 | Supply & Fixing Plate girder or single stanchions of grade Fe-410- W quality A, built up of one beam or channel section with flange plates, caps, bases. Splices, angle brackets, cleats and other connections, complete all as specified and directed by Engineer-in-charge. |
| 69 | Supply & Fixing Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of grade Fe 410-W quality A, complete all as specified and directed by Engineer-in-charge. |
| 70 | Supply & Fixing Mild steel screw bolts (machine made) of dia 11 to 15mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm long but n exc 10 cm, complete all as specified and directed by Engineer-in-charge. |
| 71 | Material & Labour for preparing new surface of steel of any desc over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-charge. |
| 72 | Material & Labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in filling in chowkhats, hold fast block etc., complete all as specified and directed by Engineer-in-charge. |
| 73 | Material & Labour for Mild CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-charge. |
| 74 | -ditto- all as per item No.72 above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-charge. |
| 75 | Supply & Fixing anodised aluminium snap grid frame work size of grid 605mm x 605mm for false ceiling, complete all as specified and directed by Engineer-in-charge. |
| 76 | Supply & Fixing Hangers 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, complete all as specified and directed by Engineer-in-charge. |
| 77 | Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturer’s instructions, complete all as specified and directed by Engineer-in-charge. |
| 78 | Dismantling boarding, any description, fixed in any position with nails, complete all as specified and directed by Engineer-in-charge. |
| 79 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engineer-in-charge. |
| 80 | Dismantling of mild steel work as in angle iron frames/grills mild steel bars etc., complete all as specified and directed by Engineer-in-charge. |
| 81 | Supply & Fixing Galvanised iron Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, tubular, channel or flat sections), including distance piece, cleats etc fixing complete using Fe-410-W (Gde E-250) quality-A, complete all as specified and directed by Engineer-in-charge. |
| 82 | Supply & Fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm and not exc. 10 cm long with 5 to 10mm dia of neck, complete all as specified and directed by Engineer-in-charge. |
| 83 | Supply & Fixing Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screw, complete all as specified and directed by Engineer-in-charge. |
| 84 | Supply & Fixing Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screw, complete all as specified and directed by Engineer-in-charge. |
| 85 | Supply & Fixing 4mm thick PVC false ceiling tile of size 595 x 595mm, complete all as specified and directed by Engineer-in-charge. |
| 86 | Supply and fixing 12mm thick toughened glass as in hinged doors, partitions automatic doors, railing and similar work including cutting to shape, drilling holes required with all stainless steel fitting including L connector, silicon fixer etc., including floor door spring of appropriate weight with all fittings, complete all as specified and directed by Engineer-in-charge. |
| 87 | Material & Labour for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors, complete all as specified and directed by Engineer-in-charge. |
| 88 | Material & Labour for Preparation of old painted steel based surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint etc., complete all as specified and directed by Engineer-in-charge. |
| 89 | Material & Labour for Pre-cast cement concrete block masonry (Type C-1, 1:3:6 (20mm aggregate) in with solid blocks, exc. 10 cm in width and setting in Cement mortar 1:6, complete all as specified and directed by Engineer-in-charge. |
| 90 | Material & Labour for rendering 15mm thick on concrete surfaces in cement mortar 1:4 and even and smooth without using extra cement, complete all as specified and directed by Engineer-in-charge. |
| 91 | Material & Labour for 10mm thick rendering in Cement Mortar 1:6 to concrete surfaces trowelled to even & smooth w/o using extra cement, complete all as specified and directed by Engineer-in-charge. |
| 92 | Supply & Fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (±0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter) (45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick galvanized steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm) 2nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100m long fastener. Hardware (touch lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate excludes cost of glass and includes all other connected accessories) area n. exc. 2.00 sqm each fixed from ground floor to any height of floors, complete all as specified and directed by Engineer-in-charge. |
| 93 | Supply & Fixing 7mm thick aluminium grills of make \\"Deco grill\\" model DG 104 surrounded by aluminium 'C' channel and size of opening 75x75 mm all as specified and directed fixed from ground floor to any height of floors, complete all as specified and directed by Engineer-in-charge. |
| 94 | Supply & Fixing factory made uPVC white colour fixed window/ventilator made of extruded profile with wall thickness of 2.3 mm (±2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (one vertical length in between two shutters) (60mm x74mm). Glazed bead (35mm x 20mm) will be mitered cut and fusion welded at all corners. Including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick. galvanized steel frame (28mm x 21.5mm), T profile (27mm x 17mm) to be inserted in repair profile. Frame will be fixed to the wall with 8mm x 100mm long fasteners. 5mm thick glazing with selected quality glass (Note: The unit rate excludes cost of glass and includes all other connected accessories.) area n. exc. 1.00 sqm each fixed from ground floor to any height of floors, complete all as specified and directed by Engineer-in-charge. |
| 95 | Supply & Fixing 5mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each panel, complete all as specified and directed by Engineer-in-charge. |
| 96 | Material & Labour for 20 to 25mm thick machine cut Kota stone (single piece of required size for steps) flooring over cement screed base laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and Mirror polishing complete all as specified over and including 15mm thick screed bed in Cement Mortar 1:4, complete all as specified and directed by Engineer-in-charge. Note: - Kota stone in S /case should be provided in single piece upto 1.5 Metre length or as per site requirements complete all as specified and as directed by Engineer-in-Charge. |
| 97 | ditto - all as above item No. 95 but kota stone slab (100/150mm x 550mm) and 20-25mm thick in riser of steps, skirting, dados and pillar laid over and including 10mm thick rendering to receive the stone in cement mortar 1:3 and jointed, complete all as specified and directed by Engineer-in-charge. Note:- Kota stone in S /case should be provided in single piece upto 1.5 Metre length. |
| 98 | Material & Labour for complete removal of old plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of smooth putty all as per the manufacturer’s instructions, complete all as specified and directed by Engineer-in-charge. |
| 99 | Material & Labour for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over a coat of smooth putty all as per the manufacturer’s instructions, complete all as specified and directed by Engineer-in-charge. |
| 100 | Supply & Fixing in repair Harrison rails stainless steel (Curtain rod/drapery rod), 20mm dia, powder coated with and including fancy type bracket 2 Nos of each opening and side stopper fancy type powder coated of required shape and size 2 Nos of each opening, complete all as specified and directed by Engineer-in-charge. |
| 101 | Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc., including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 Kg/Sqm, complete all as specified and directed by Engineer-in-charge. |
| 102 | Material & Labour for 40mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in padding to roof slab and rendering 5mm thick in one layers on concrete surface cement sand mortar 1:3 using water proofing compound as per manufacturer’s instruction finished even fair and smooth without using extra cement, complete all as specified and directed by Engineer-in-charge.(WPC will be measured and paid separately). |
| 103 | Material & Labour for providing APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3 KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely.(ii) Applying APP based pre-fabricated with non-woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method.(iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm over mineral surface. |
| 104 | Supply only liquid water proofing compound, complete all as specified and directed by Engineer-in-charge. |
| 105 | Supply & Fixing in repair Steel rolling shutters, without ball bearing, as specified including top cover as per IS: 6248-1979, anchoring rod, hasp and staple; erected in position as indicated, push pull or manual type, complete all as specified and directed by Engineer-in-charge. |
| 106 | Supply & Fixing Ball bearing for rolling shutters as per IS: 6248-1979, complete all as specified and directed by Engineer-in-charge. |
| 107 | Excavation over area not exceeding 1.50 Metre deep and getting out in soft soil, complete all as specified and directed by Engineer-in-charge. |
| 108 | Removing excavated soil exc. 500 Metre and not exceeding 1.50 Km depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-charge. |
| 109 | Material & Labour for Hard-core of broken stone or boulders gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and directed by Engineer-in-charge. |
| 110 | Material & Labour for 80mm thick M-40 Grade Machine pressed precast concrete paver block of any colour any shape and size confirming to IS 15658-2006 with grey cement and pigment, complete all as specified and directed by Engineer-in-charge. |
| 111 | Material & Labour for 50mm thick Sand filling under floors or in foundation including watering and consolidation, complete all as specified and directed by Engineer-in-charge. |
| 112 | Excavating in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5 Metre in depth and getting out hard rock, complete all as specified and directed by Engineer-in-charge. |
| 113 | Excavating in post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering, and removing surplus soil to a distance n. exc 50 Metre and making good surface in hard rock, complete all as specified and directed by Engineer-in-charge. |
| 114 | Supply & Fixing Rolled sections of grade Fe 410 as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, complete all as specified and directed by Engineer-in-charge. |
| 115 | Material & Labour for two coats of anticorrosive Epoxy Paint over a coat of primer on steel & iron surfaces over 10cm width or girth including preparation of new surfaces, complete all as specified and directed by Engineer-in-charge. |
| 116 | Schedule 'A' E/M |
| 117 | Taking down carefully copper /aluminium point wiring (light, fan, socket or power point) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good distribution surfaces of walls, floors, etc., complete all as specified and directed by Engr-in-charge. |
| 118 | Taking down electric connections and taking down old unserviceable MCB SPN/SP/TPN/MS, Meter Box, DB's etc., of any capacity, complete all as specified and directed by Engr-in-charge. |
| 119 | Taking down carefully unserviceable sub main wiring, complete all as specified and directed by Engr-in-charge. |
| 120 | Material & Labour for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non-metallic rigid PVC heavy duty concealed conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:- |
| 121 | One light point controlled by one, one way switch |
| 122 | One Fan/ Exhaust Fan point controlled by one way switch |
| 123 | One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch. |
| 124 | One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch. |
| 125 | All as per srl item no. 119 here-in-before but with 2.5 sqmm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for independent 15 Amp point. |
| 126 | All as per srl item no. 119 here-in-before but with 4 sqmm FRLS copper wire with 4 Sqmm FRLS copper earth wire for independent 15 Amp point. |
| 127 | Supply & Fixing Modular switch flush type single pole one way 6 Amp ISI Marked, complete all as specified and directed by Engineer-in-Charge. |
| 128 | Supply & Fixing Modular switch flush type single pole one way 16 Amp ISI Marked, complete all as specified and directed by Engineer-in-Charge. |
| 129 | Supply & Fixing Modular socket outlet 2 in 1, 3 pin, 6 Amp, 230 Volts flush type, complete all as specified and directed by Engineer-in-Charge. |
| 130 | Supply & Fixing Modular socket outlet shutter type 2 in 1, 6 pin, 5 and 16 amp flush type, 230 Volts ISI Marked, complete all as specified and directed by Engineer-in-Charge. |
| 131 | Supply and fix modular socketed stepped type electonic fan regulator flush type ISI Marked, complete all as specified and directed by Engineer-in-Charge. |
| 132 | Supply & Fixing Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as specified and directed by Engineer-in-Charge. |
| 133 | Supply and fixing LED lights fitting (Warm White/White) 1x 20W, 220V, AC decorative box type with driver, holder including AC decorative box type with driver, holder including,copper conductor cable of suitable size from ceiling rose complete complete, 4 ft long, complete all as specified and directed by Engineer-in-Charge. |
| 134 | Supply & Fixing bldg security LED Light Luminaire of 35 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 40mm bracket of 1.5 Metre in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable, complete all as specified and directed by Engineer-in-Charge. |
| 135 | Supply and fixing LED light fitting (Warm White/White) mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer-in-Charge. |
| 136 | Supply and fixing round/Square shape (Warm White/White) 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed by Engineer-in-Charge. |
| 137 | Supply & Fixing Decorative wall light made up of high grade engineering plastic material suitable for and including 9 W LED lamp(Warm White/White), complete all as specified and directed by Engineer-in-Charge. |
| 138 | Material & Labour for taking down old serviceable fan and refixing in same position after painting including connectoin from celing rose to fan connector, complete all as specified and directed by Engineer-in-Charge. |
| 139 | Supply & Fixing Vertical Distribution Board, double Door, suitable for 'A' Frame FP MCCB 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed by Engineer-in-Charge.Note : MCCB & MCB will be measured and paid separately under respective items |
| 140 | Supply & Fixing MCCB, A Frame, thermal adjustable magnectic setting, Ics = 75% 16 kA, 415V, 100 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as specified and directed by Engineer-in-Charge. |
| 141 | Supply & Fixing MCB, B Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as specified and directed by Engineer-in-Charge. |
| 142 | Supply & Fixing MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specified and directed by Engineer-in-Charge. |
| 143 | Supply and fixing as MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall, complete all as specified and directed by Engineer-in-Charge. |
| 144 | Material & Labour for sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 15mm dia size including all conduit accessories & fittings / junction boxes / inspection covers etc, with and including cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as specified and directed by Engineer-in-Charge.Note:- Two run of 6 Sqmm and one run of 6 Sqmm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces. |
| 145 | All as per Item No 139 above but Submain FRLS Cable size 4 Sqmm, complete all as specified and directed by Engineer-in-Charge. |
| 146 | All as per Item No 139 above but Submain FRLS Cable size 2.5 Sqmm, complete all as specified and directed by Engineer-in-Charge. |
| 147 | Material & Labour for in repairs earthing complete with galvanised steel earth electrode 60cm x 60cm x 6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C-1 in chamber, precast RCC 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed by Engineer-in-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. |
| 148 | Supply, laying testing in trenches LT UG XLPE insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 50 sqmm 3.5 core, complete all as specified and directed by Engineer-in-Charge. Note : Earth work and brick work measured and paid separately |
| 149 | Supply and lay double wall corrugated (DWC) 50/38mm outer dia high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 ( Part I and II) for protection of underground calbes laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection, complete all as specified and directed by Engineer-in-Charge. |
| 150 | Supply & Fixing of Heavy duty Exhaust fan 300mm sweep, 900 RPM, including louvers with cutting chases on brick wall and grounting with nut bolts, complete all as specified and directed by Engineer-in-Charge. |
| 151 | Supply & Fixing Ventilaion fan Plastic body 230mm sweep including louvers with cutting chases on brick wall and grounting with nut bolts complete all as specified and directed by Engr-in-charge. |
| 152 | Supply & Fixing electric storage water heater of capacity 25 litres BEE 5 star rated including proper installing arrangment on wall surface with suitable Anchor bolt fatser and Geyser connections for hot and cold water supply made of stainless steel wire braided connrtector with chrome finish heavy duty nuts of 15mm size with suitable lengh etc., complete all as directed by Engineer-in-Charge. |
| 153 | Supply and fixing MCB TPN C Curve 63 Amps, complete all as specified and directed by Engineer-in-Charge. |
| 154 | Supply and fixing of sheet metal enclosure SPN with a two pin earth plug and socket with metal cladd top and one MCB, SP 20 Amps capacity, complete all as specified and directed by Engineer-in-Charge. |
| 155 | Supply & Fixing in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engr-in-charge. Make Philips - Cat Part No- BN100C LED40S-6500 PSU L120 GR or equivalent to Wipro/GE lighting or equivalent make mentioned in Appendix 'B'. |
| 156 | Supply & Fixing LED 25 Watts (5700K) Bldg Security light fitting, and including with GI Pipe 32 mm dia bracket with connected with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting in position at site, complete all as specified and directed by Engr-in-charge. Make: Wipro Cat No LR02-291-XXX-57-XX /Philips / Havells /CG or equivalent make mentioned in Appendix 'B'. |
| 157 | Supply & Fixing Sheet metal enclosure (factory made) double door for distribution board (when MCB's are to be used) Single pole neutral 240 V, 8 ways with 200 Amp rated bus bar connection with suitable size of thimbles, complete all as specified and directed by Engr-in-charge. |
| 158 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and Neutral current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed by Engr-in-charge. |
| 159 | Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed by Engr-in-charge. |
| 160 | Material & Labour for Earthing for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron strips 32x6mm as Earthing lead with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protected steel with funnel complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009, complete all as specified and directed by Engr-in-charge. |
| 161 | Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 16 Sqmm 2 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc., all connections, complete all as specified and directed by Engineer-in-Charge. |
| 162 | Material & Labour for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:3:6; including removal of surpluses soil, complete all as specified and directed by Engineer-in-Charge. |
| 163 | Supply & Fixing in replacement of Smart motion LED Luminaires recessed/surface mounted 15 watt 6500K system efficiency having smart motion sense radius 4.5 meter, not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge. |
| 164 | Supply and fixing LED luminaire 600mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed by Engineer-in-Charge. |
| 165 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer-in-Charge. |
| 166 | Taking up and down of existing ceiling fan after that dismantling of fan motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material, replacement of 2.5mfd capacitor and reassembling. including painting of fan and blades, complete all as specified and directed by Engineer-in-Charge. |
| 167 | Supply and fixing exhaust fan, steel body AC single Phase. 230 V of size 300mm sweep with, blades, and frame and louvers, complete all as specified and directed by Engineer-in-Charge.Note : Cutting of wall of appropriate size of fan and making good in cement Mortar 1:3 or cement concrete 1:2:4 type B-1 as depth of cut required and finishing properly to match the surfaces to fix the Exhaust fan is inclusive job in each of item. |
| 168 | Supply & Fixing Sheet metal enclosure (factory made) double door for distribution board (when MCB's are to be used) Single pole neutral 240 V, 16 ways with 200 Amp rated busbar connectin with suitable size of thimbles, complete all as specified and directed by Engineer-in-Charge. |
| 169 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32Amp current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge. |
| 170 | Supply & Fixing Modular Motor starter 16 Amp capacity, 02 Module with metal flush box, cover plate of required module for Acs, complete all as specified and directed by Engineer-in-Charge. |
| 171 | Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location, refixing of same AC at new location, complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers.(b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer.(c) All civil work such as making hole in the wall for passing of pipe etc., to be done, as directed by Engr-in-Charge including making good disturbed surface.(d) concealing of refrigerant pipe with PVC flexible pipe. (e) Extention of pipe due to site condition if required shall be measured and paid separately under respective items taken before. |
| 172 | Material & Labour for replacement of suction copper tubing of size 5/8'' dia meter with rubberised insulation and tape suitable for supply pipes for air-conditioners, complete all as specified and directed by Engineer-in-Charge. |
| 173 | Material & Labour for replacment of discharge copper tubing of size 3/8\\" existing size mm bore including brazing etc and with rubberised insulation and tape suitable for supply pipes for air-conditioners, complete all as specified and directed by Engineer-in-Charge. |
| 174 | Material & Labour for topping of refrigerant R-410/R-22/R-32 gas to air conditioner or as per existing /manufacturer instrcutions suitable for split air conditioner cap 1.5/2.0 ton after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge. |
| 175 | Supply and fixing in repair flexible PVC pipe for condense water outlet for Split AC as per existing, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail